Search NASA⌕ Search

SEARCH · Search NASA

Results for “tasks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Current Status and Recommendations for the Future of Research, Teaching, and Testing in the Biological Sciences of Radiation Oncology: Report of the American Society for Radiation Oncology Cancer Biology/Radiation Biology Task Force, Executive Summary

In early 2011, a dialogue was initiated within the Board of Directors (BOD) of the American Society for Radiation Oncology (ASTRO) regarding the future of the basic sciences of the specialty, primarily focused on the current state and potential future direction of basic research within radiation oncology. After consideration of the complexity of the issues involved and the precise nature of the undertaking, in August 2011, the BOD empanelled a Cancer Biology/Radiation Biology Task Force (TF). The TF was charged with developing an accurate snapshot of the current state of basic (preclinical) research in radiation oncology from the perspective of relevance to the modern clinical practice of radiation oncology as well as the education of our trainees and attending physicians in the biological sciences. The TF was further charged with making suggestions as to critical areas of biological basic research investigation that might be most likely to maintain and build further the scientific foundation and vitality of radiation oncology as an independent and vibrant medical specialty. It was not within the scope of service of the TF to consider the quality of ongoing research efforts within the broader radiation oncology space, to presume to consider their future potential, or to discourage in any way the investigators committed to areas of interest other than those targeted. The TF charge specifically precluded consideration of research issues related to technology, physics, or clinical investigations. This document represents an Executive Summary of the Task Force report.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the interplay of resilience and energy consumption for a task-based partial differential equations preconditioner

Here, we discuss algorithm-based resilience to silent data corruptions (SDCs) in a task-based domain-decomposition preconditioner for partial differential equations (PDEs). The algorithm exploits a reformulation of the PDE as a sampling problem, followed by a solution update through data manipulation that is resilient to SDCs. The implementation is based on a server-client model where all state information is held by the servers, while clients are designed solely as computational units. Scalability tests run up to ~51K cores show a parallel efficiency greater than 90%. We use a 2D elliptic PDE and a fault model based on random single and double bit-flip to demonstrate the resilience of the application to synthetically injected SDC. We discuss two fault scenarios: one based on the corruption of all data of a target task, and the other involving the corruption of a single data point. We show that for our application, given the test problem considered, a four-fold increase in the number of faults only yields a 2% change in the overhead to overcome their presence, from 7% to 9%. We then discuss potential savings in energy consumption via dynamic voltage/frequency scaling, and its interplay with fault-rates, and application overhead.

97 MATHEMATICS AND COMPUTING↗

Online task-space motion control for positioner-coordinated multi-robot manufacturing systems

Incorporating multiple robotic manipulators into large-scale manufacturing systems enhances production efficiency and expands manufacturing capabilities beyond those of single-robot systems. Workpiece positioners in robotic manufacturing have demonstrated significant benefits for process optimization, but coordination strategies for multi-robot systems with shared positioners have received limited attention. This work presents a task-space coordinated trajectory-tracking control framework for multi-robot manufacturing systems, in which robots coordinate their motions within a shared, dynamic workpiece positioning frame. A workpiece positioner actively adjusts the pose of the manufactured component to enable greater operational concurrency and improve overall production efficiency. The proposed motion-coordination scheme employs a distributed and scalable architecture, supporting coordination across heterogeneous multi-robot systems. Two optimization methodologies are introduced to manage kinematic redundancies and maintain continuous, near-optimal operation throughout the manufacturing process. The first strategy exploits a task-space dimensionality reduction to achieve locally optimal configurations by leveraging symmetry-axis rotations of the tool. The second strategy utilizes the workpiece positioner to drive the coordinated robots toward stable and kinematically favorable configurations. For both optimization strategies, multiple objectives are defined to improve key performance metrics, including manipulability, configuration consistency, proximity to mechanical limits, and motion efficiency. Addressing a key limitation of existing coordination approaches, the framework is designed around online setpoint modification, allowing coordinated robots to respond effectively to in-situ process feedback. The proposed control framework is validated using the Robot Operating System (ROS) middleware on a combination of physical and simulated multi-robot system hardware.

Arbogast, Alex [ORNL] (ORCID:0000000154740723)↗

Task-oriented machine learning surrogates for tipping points of agent-based models

We present a machine learning framework bridging manifold learning, neural networks, Gaussian processes, and Equation-Free multiscale approach, for the construction of different types of effective reduced order models from detailed agent-based simulators and the systematic multiscale numerical analysis of their emergent dynamics. The specific tasks of interest here include the detection of tipping points, and the uncertainty quantification of rare events near them. Our illustrative examples are an event-driven, stochastic financial market model describing the mimetic behavior of traders, and a compartmental stochastic epidemic model on an Erdös-Rényi network. We contrast the pros and cons of the different types of surrogate models and the effort involved in learning them. Importantly, the proposed framework reveals that, around the tipping points, the emergent dynamics of both benchmark examples can be effectively described by a one-dimensional stochastic differential equation, thus revealing the intrinsic dimensionality of the normal form of the specific type of the tipping point. This allows a significant reduction in the computational cost of the tasks of interest.

97 MATHEMATICS AND COMPUTING↗

Job Management and Task Bundling

High Performance Computing is often performed on scarce and shared computing resources. To ensure computers are used to their full capacity, administrators often incentivize large workloads that are not possible on smaller systems. Measurements in Lattice QCD frequently do not scale to machine-size workloads. By bundling tasks together we can create large jobs suitable for gigantic partitions. We discuss METAQ and mpi_jm, software developed to dynamically group computational tasks together, that can intelligently backfill to consume idle time without substantial changes to users’ current workflows or executables.

Berkowitz, Evan↗

Lightweight jet reconstruction and identification as an object detection task

We apply object detection techniques based on deep convolutional blocks to end-to-end jet identification and reconstruction tasks encountered at the CERN large hadron collider (LHC). Collision events produced at the LHC and represented as an image composed of calorimeter and tracker cells are given as an input to a Single Shot Detection network. The algorithm, named PFJet-SSD performs simultaneous localization, classification and regression tasks to cluster jets and reconstruct their features. This all-in-one single feed-forward pass gives advantages in terms of execution time and an improved accuracy w.r.t. traditional rule-based methods. A further gain is obtained from network slimming, homogeneous quantization, and optimized runtime for meeting memory and latency constraints of a typical real-time processing environment. We experiment with 8-bit and ternary quantization, benchmarking their accuracy and inference latency against a single-precision floating-point. We show that the ternary network closely matches the performance of its full-precision equivalent and outperforms the state-of-the-art rule-based algorithm. Finally, we report the inference latency on different hardware platforms and discuss future applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transcranial stimulation over the left inferior frontal gyrus increases false alarms in an associative memory task in older adults

Here, transcranial direct current stimulation (tDCS) is a potent ial tool for alleviating various forms of cognitive decline, including memory loss, in older adults. However, past effects of tDCS on cognitive ability have been mixed. One important potential moderator of tDCS effects is the baseline level of cognitive performance. We tested the effects of tDCS on face-name associative memory in older adults, who suffer from performance deficits in this task relative to younger adults. Stimulation was applied to the left inferior prefrontal cortex during encoding of face-name pairs, and memory was assessed with both a recognition and recall task. As a result, face–name memory performance was decreased with the use of tDCS. This result was driven by increased false alarms when recognizing rearranged face–name pairs.

60 APPLIED LIFE SCIENCES↗

Foundation model framework for all tasks involving jet physics

Foundation models use large datasets to build an effective representation of data that can be deployed on diverse downstream tasks. Previous research developed the omnilearn foundation model for jet physics, using unique properties of particle physics, and showed that it could significantly advance discovery potential across collider experiments. This paper introduces a major upgrade, resulting in the omnilearned framework. This framework has three new elements: (1) updates to the model architecture and training, (2) using over 1 × 10 9 jets used for training, and (3) providing well-documented software for accessing all datasets and models. We demonstrate omnilearned with three representative tasks: top-quark jet tagging with the community delphes-based benchmark dataset, b tagging with ATLAS full simulation, and anomaly detection with CMS experimental data. In each case, omnilearned is the state of the art, further expanding the discovery potential of past, current, and future collider experiments.

Bhimji, Wahid [Lawrence Berkeley National Laborato↗

Quantum speed limits for quantum-information-processing tasks

We derive algebraic bounds on achievable rates for quantum state transfer and entanglement generation in general quantum systems. We apply these bounds to graph-based models of local quantum spin systems to obtain speed limits on these tasks. A comparison to numerical optimal control results for spin chains suggests that unexplored regions of the dynamical landscape may support enhanced performance of key quantum-information-processing tasks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient graph representation framework for chemical molecule similarity tasks

Graph data has emerged in numerous scientific domains and machine learning techniques have been widely used for analysis and learning of diverse data for prediction and decision. Machine learning techniques can readily address complex problems by leveraging their structural information. But graphs cannot be directly used for existing machine learning algorithms unless encoded as vectors. The problem of efficient representation of graphs is a substantial challenge in graph machine learning. In this paper, we propose a novel two-stage framework for the representation of chemical molecule graphs based on the strengths of Graph Isomorphism Networks (GINs) and Siamese autoencoders. In the first stage, the GIN model is constructed and trained using the structural information of chemical molecule graphs. Node attributes, edge attributes, and edge indices are used as input data, while graph attributes are used as labels. The GIN model effectively captures the structural characteristics of graphs and can accurately predict graph attributes, i.e., molecular properties. It also generates Graph Embeddings, represented as vectors that encode the structural information of graphs. In the second stage, Graph Embedding vectors are further optimized for downstream similarity tasks while preserving the graph structural information. The Siamese autoencoder is constructed and trained, which reduces the dimensionality of the Graph Embedding vectors, while maximizing the preservation of structural information in the original high-dimensional vectors. The resulting low-dimensional Graph Embeddings can be effectively utilized for tasks such as approximate nearest neighbor search. The experimental results demonstrate the effectiveness of our proposed framework in accurately predicting graph similarity.

Ma, Jiaji↗

AutomaDeD: Automata-Based Debugging for Dissimilar Parallel Tasks

Today's largest systems have over 100,000 cores, with million-core systems expected over the next few years. This growing scale makes debugging the applications that run on them a daunting challenge. Few debugging tools perform well at this scale and most provide an overload of information about the entire job. Developers need tools that quickly direct them to the root cause of the problem. This paper presents AutomaDeD, a tool that identifies which tasks of a large-scale application first manifest a bug at a specific code region at a specific point during program execution. AutomaDeD creates a statistical model of the application's control-flow and timing behavior that organizes tasks into groups and identifies deviations from normal execution, thus significantly reducing debugging effort. In addition to a case study in which AutomaDeD locates a bug that occurred during development of MVAPICH, we evaluate AutomaDeD on a range of bugs injected into the NAS parallel benchmarks. Our results demonstrate that detects the time period when a bug first manifested itself with 90% accuracy for stalls and hangs and 70% accuracy for interference faults. It identifies the subset of processes first affected by the fault with 80% accuracy and 70% accuracy, respectively and the code region where where the fault first manifested with 90% and 50% accuracy, respectively.

97 MATHEMATICS AND COMPUTING↗

Task-Based Neuromodulation Architecture for Lifelong Learning

The conventional supervised deep learning frameworks for image classification focus on finding the minimizer of an objective function. However, for a lifelong learning system, a network has to be able to dynamically learn new tasks from very few examples. In biological neural networks, it is observed that neuromodulation acts as a key factor in continual learning. In this work, we propose a dynamic learning system, ModNet, wherein a modulatory unit regulates the learning depending on the context and the internal state of the system. The modulatory unit, which consists of a group of neurons, exercises the use of neuromodulation and Hebbian plasticity mechanisms over a population of neurons instead of relying on backpropagation of error gradients. An efficient digital architecture with on-chip training and resource sharing is proposed to facilitate the efficacy of task-based processing.

brain-inspired↗

Effects of Field of View and Visual Complexity on Virtual Reality Training Effectiveness for a Visual Scanning Task

Virtual reality training systems are commonly used in a variety of domains, and it is important to understand how the realism of a training simulation influences training effectiveness. The paper presents a framework for evaluating the effects of virtual reality fidelity based on an analysis of a simulation’s display, interaction, and scenario components. Following this framework, we conducted a controlled experiment to test the effects of fidelity on training effectiveness for a visual scanning task. The experiment varied the levels of field of view and visual realism during a training phase and then evaluated scanning performance with the simulator’s highest level of fidelity. To assess scanning performance, we measured target detection and adherence to a prescribed strategy. The results show that both field of view and visual realism significantly affected target detection during training; higher field of view led to better performance and higher visual realism worsened performance. Additionally, the level of visual realism during training significantly affected learning of the prescribed visual scanning strategy, providing evidence that high visual realism was important for learning the technique. The results also demonstrate that task performance during training was not always a sufficient measure of mastery of an instructed technique. That is, if learning a prescribed strategy or skill is the goal of a training exercise, performance in a simulation may not be an appropriate indicator of effectiveness outside of training—evaluation in a more realistic setting may be necessary.

97 MATHEMATICS AND COMPUTING↗

Dose calculation formalisms and consensus dosimetry parameters for intravascular brachytherapy dosimetry: Recommendations of the AAPM Therapy Physics Committee Task Group No. 149

Since the publication of AAPM Task Group 60 report in 1999, a considerable amount of dosimetry data for the three coronary brachytherapy systems in use in the United States has been reported. A subgroup, Task Group 149, of the AAPM working group on Special Brachytherapy Modalities (Bruce Thomadsen, Chair) was charged to develop recommendations for dose calculation formalisms and the related consensus dosimetry parameters. The recommendations of this group are presented here. For the Cordis {sup 192}Ir and Novoste {sup 90}Sr/{sup 90}Y systems, the original TG-43 formalism in spherical coordinates should be used along with the consensus values of the dose rate constant, geometry function, radial dose function, and anisotropy function for the single seeds. Contributions from the single seeds should be added linearly for the calculation of dose distributions from a source train. For the Guidant {sup 32}P wire system, the modified TG-43 formalism in cylindrical coordinates along with the recommended data for the 20 and 27 mm wires should be used. Data tables for the 6, 10, 14, 18, and 22 seed trains of the Cordis system, 30, 40, and 60 mm seed trains of the Novoste system, and the 20 and 27 mm wires of the Guidant system are presented along with our rationale and methodology for selecting the consensus data. Briefly, all available datasets were compared with each other and the consensus dataset was either an average of available data or the one obtained from the most densely populated study; in most cases this was a Monte Carlo calculation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Stereotactic body radiation therapy: The report of AAPM Task Group 101

Task Group 101 of the AAPM has prepared this report for medical physicists, clinicians, and therapists in order to outline the best practice guidelines for the external-beam radiation therapy technique referred to as stereotactic body radiation therapy (SBRT). The task group report includes a review of the literature to identify reported clinical findings and expected outcomes for this treatment modality. Information is provided for establishing a SBRT program, including protocols, equipment, resources, and QA procedures. Additionally, suggestions for developing consistent documentation for prescribing, reporting, and recording SBRT treatment delivery is provided.

60 APPLIED LIFE SCIENCES↗

Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71

A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D{sub 0}{sup ′}, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D{sub 0}{sup ′} = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent D{sub 0}{sup ′} ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of d{sub m}, with D{sub 0}{sup ′} = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-dose preview for patient-specific, task-specific technique selection in cone-beam CT

Purpose : A method is presented for generating simulated low-dose cone-beam CT (CBCT) preview images from which patient- and task-specific minimum-dose protocols can be confidently selected prospectively in clinical scenarios involving repeat scans. Methods : In clinical scenarios involving a series of CBCT images, the low-dose preview (LDP) method operates upon the first scan to create a projection dataset that accurately simulates the effects of dose reduction in subsequent scans by injecting noise of proper magnitude and correlation, including both quantum and electronic readout noise as important components of image noise in flat-panel detector CBCT. Experiments were conducted to validate the LDP method in both a head phantom and a cadaveric torso by performing CBCT acquisitions spanning a wide dose range (head: 0.8–13.2 mGy, body: 0.8–12.4 mGy) with a prototype mobile C-arm system. After injecting correlated noise to simulate dose reduction, the projections were reconstructed using both conventional filtered backprojection (FBP) and an iterative, model-based image reconstruction method (MBIR). The LDP images were then compared to real CBCT images in terms of noise magnitude, noise-power spectrum (NPS), spatial resolution, contrast, and artifacts. Results : For both FBP and MBIR, the LDP images exhibited accurate levels of spatial resolution and contrast that were unaffected by the correlated noise injection, as expected. Furthermore, the LDP image noise magnitude and NPS were in strong agreement with real CBCT images acquired at the corresponding, reduced dose level across the entire dose range considered. The noise magnitude agreed within 7% for both the head phantom and cadaveric torso, and the NPS showed a similar level of agreement up to the Nyquist frequency. Therefore, the LDP images were highly representative of real image quality across a broad range of dose and reconstruction methods. On the other hand, naïve injection ofuncorrelated noise resulted in strong underestimation of the true noise, which would lead to overly optimistic predictions of dose reduction. Conclusions : Correlated noise injection is essential to accurate simulation of CBCT image quality at reduced dose. With the proposed LDP method, the user can prospectively select patient-specific, minimum-dose protocols (viz., acquisition technique and reconstruction method) suitable to a particular imaging task and to the user's own observer preferences for CBCT scans following the first acquisition. The method could provide dose reduction in common clinical scenarios involving multiple CBCT scans, such as image-guided surgery and radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-273: Do Task Group External Beam QA Recommendations Guarantee Accurate Treatment Plan Dose Delivery?

Purpose: AAPM task groups 40/142 have provided an invaluable set of goals for physicists designing QA programs, attempting to standardize what would otherwise likely be a highly variable phenomenon across institutions. However, with the complexity of modalities such as VMAT, we hypothesize that following these guidelines to the letter might still allow unacceptable dose discrepancies. To explore this hypothesis we simulated machines bordering on QA acceptability, and calculated the effect on patient plans. Methods: Two errant machines were simulated in Aria/Eclipse, each just within task group criteria for output, percent depth dose, beam profile, gantry and collimator rotations, and jaw and MLC positions. One machine minimized dose to the PTV (machine A) and the other maximized dose to the OARs (machine B). Clinical treatment plans (3-phase prostate, n=3; hypofractionated lung, n=1) were calculated on these machines and the dose distributions compared. A prostate case was examined for contribution of error sources and evaluated using delivery QA data. Results: The prostate plans showed mean decreases in target D95 of 9.9% of prescription dose on machine A. On machine B, The rectal and bladder V70Gy each increased by 7.1 percentage points, while their V45Gy increased by 16.2% and 15.0% respectively. In the lung plan, the target D95 decreased by 12.8% and the bronchial tree Dmax increased by 21% of prescription dose, on machines A and B. One prostate plan showed target dose errors of 3.8% from MLC changes, 2% from output, ∼3% from energy and ∼0.5% from other factors. This plan achieved an 88.4% gamma passing rate using 3%/3mm using ArcCHECK. Conclusion: In the unlikely event that a machine exhibits all maximum errors allowed by TG 40/142, unacceptably large changes in dose delivered are possible especially in highly modulated VMAT plans, despite the machine passing routine QA.

60 APPLIED LIFE SCIENCES↗