Search NASA⌕ Search

SEARCH · Search NASA

Results for “time segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Stochastic Kinetics of Nanocatalytic Systems

Catalytic reaction events occurring on the surface of a nanoparticle constitute a complex stochastic process. Although advances in modern single-molecule experiments enable direct measurements of individual catalytic turnover events occurring on a segment of a single nanoparticle, we do not yet know how to measure the number of catalytic sites in each segment or how the catalytic turnover counting statistics and the catalytic turnover time distribution are related to the microscopic dynamics of catalytic reactions. Here, we address these issues by presenting a stochastic kinetics for nanoparticle catalytic systems. We propose a new experimental measure of the number of catalytic sites in terms of the mean and variance of the catalytic event count. By considering three types of nanocatalytic systems, we investigate how the mean, the variance, and the distribution of the catalytic turnover time depend on the catalytic reaction dynamics, the heterogeneity of catalytic activity, and communication among catalytic sites. This work enables accurate quantitative analyses of single-molecule experiments for nanocatalytic systems and enzymes with multiple catalytic sites.

Statistical Physics↗

Smart Meter Driven Segmentation: What Your Consumption Says About You

With the rollout of smart metering infrastructure at scale, demand-response (DR) programs may now be tailored based on users' consumption patterns as mined from sensed data. For issuing DR events it is key to understand the inter-temporal consumption dynamics as to appropriately segment the user population. We propose to infer occupancy states from consumption time series data using a hidden Markov model framework. Occupancy is characterized in this model by 1) magnitude, 2) duration, and 3) variability. We show that users may be grouped according to their consumption patterns into groups that exhibit qualitatively different dynamics that may be exploited for program enrollment purposes. We investigate empirically the information that residential energy consumers' temporal energy demand patterns characterized by these three dimensions may convey about their demographic, household, and appliance stock characteristics. Our analysis shows that temporal patterns in the user's consumption data can predict with good accuracy certain user characteristics. We use this framework to argue that there is a large degree of individual predictability in user consumption at a population level.

Albert, A↗

SU-E-T-45: Antibody Mean Residence Time in Blood and Its Correlation with Protein Molecular Weight

Purpose: Animal biodistribution data are required prior to introducing a new radiopharmaceutical into clinical trials. Protein engineering, using recombinant DNA techniques can produce a large number of related (cognate) antibodies to a given molecular target. Thus, it is important that these constructs be numerically related to one another via a single criterion. In the following, we use the mean residence time (MRT) in murine blood as this criterion. Methods: Five cognate anti-CEA (Carcinoembryonic Antigen) antibodies were compared with regard to their MRT in whole blood of CEA-positive tumor-bearing (LS174T) mice. MRT was defined by blood AUC (area under the curve) divided by the initial blood uptake value; all in units of percent injected dose per gram (%ID/g). Cognates included single chain scFv (25 kDa), diabody (50 kDa), minibody (80 kDa), F(ab')2 (120 kDa), and intact (155 kDa) forms of the murine cT84.66 antibody against CEA. All were labeled with radioactive iodine. Results: The agents, in the sequence listed, exhibited MRT values of 1.16 +/- 0.01 h, 0.99 h, 5.06 +/- 0.70 h, 6.61 +/- 0.36 h, and 59.3 +/- 2.4 h respectively. Because of the monotonic nature of the sequence, a linear correlation analysis was performed between molecular weight (MW) and MRT or ln(MRT) of the 5 proteins. Probability of random correlation was 0.10 for MRT and 0.01 for ln(MRT). Conclusion: MRT values of cognate anti-CEA antibodies were found to be a monotonically increasing sequence with respect to MW. Cognate MW values correlated best to ln(MRT) of the protein species. Thus MRT was proportional to an exponential function of molecular weight. The extended intact antibody circulation time presumably reflected its relatively maximal MW. Presence of an intact FC segment on this native antibody may also have influenced these results.

60 APPLIED LIFE SCIENCES↗

WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

The quantification accuracy of dual-energy imaging is influenced by the fundamentals of x-ray physics, system geometry, data acquisition hardware/protocol, system calibration, and image processing technique. This symposium will provide updates on the following advanced application areas: Mammography. Volumetric breast density techniques based on standard mammograms require estimation of breast thickness, which is difficult to accurately measure. By comparison, calculation of breast density using dual energy mammography does not require measurement of breast thickness. Dual energy mammography has been implemented using both energy integrating flat panel detectors in conjunction with beam energy switching and energy resolved photon counting detectors. These techniques have been optimized using simulation studies and validated using physical phantoms and postmortem breasts. Chemical decomposition was used as the gold standard for volumetric breast density measurement in postmortem breasts. Breast density measurements have also been compared with results from four-category BI-RADS density rankings, standard image thresholding and Fuzzy k-mean clustering techniques. These studies indicate that dual energy mammography can be used to accurately measure volumetric breast density. Cardiovascular CT. The predicative accuracy of risk models for recurrent stroke and cardiac arrest depends heavily on accurate differentiation of thrombus or calcium from iodine in left atrial appendage or coronary arteries. The amount of energy separation is constrained by image noise; therefore, optimal kVp, beam filtration, and balanced flux are essential for the quantification accuracy of iodine and calcium. The basis materials are combined linearly to generate monochromatic energy images, where CT# accuracy and CNR are energy dependent. With optimal monochromatic energy, the mean iodine concentration for the thrombus, circulatory stasis, and control groups are significantly different. Risk classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application; Understand the different approaches to optimize dual-energy imaging techniques for different applications.

60 APPLIED LIFE SCIENCES↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reducing the Parameter Dependency of Phase-Picking Neural Networks with Dice Loss

Training a neural network for picking seismic phase arrivals has been commonly posed as a segmentation problem. It is a highly imbalanced segmentation problem in the sense that the background vastly dominates the foreground because we are trying to pick the optimal single sample point that represents the arrival of a seismic phase in a many seconds long time window. Here, we test the Dice loss, which is a preferred loss function for highly imbalanced image segmentation problems. We show that phase-picking neural networks trained on the Dice loss behave in a binary fashion for which the prediction output is almost always either nearly 1 or nearly 0. This feature removes the strong dependence of data processing workflows on the prediction score threshold, which is an otherwise critical parameter to determine when using neural networks trained on the cross-entropy loss. When strategically used, models trained on the Dice loss can reduce the parameter dependency of machine learning-based seismic monitoring.

58 GEOSCIENCES↗

Appliance Efficiency Standards and Price Discrimination

I explore the effects of two simultaneous changes in minimum energy efficiency and ENERGY STAR standards for clothes washers. Adapting the Mussa and Rosen (1978) and Ronnen (1991) second-degree price discrimination model, I demonstrate that clothes washer prices and menus adjusted to the new standards in patterns consistent with a market in which firms had been price discriminating. In particular, I show evidence of discontinuous price drops at the time the standards were imposed, driven largely by mid-low efficiency segments of the market. The price discrimination model predicts this result. On the other hand, in a perfectly competition market, prices should increase for these market segments. Additionally, new models proliferated in the highest efficiency market segment following the standard changes. Finally, I show that firms appeared to use different adaptation strategies at the two instances of the standards changing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Quality: 1979 Southeastern Virginia Urban Plume Study (SEV-UPS): Surface and Airborne studies

The SEV-UPS field study conducted during August 1979 involved the coordinated air quality data collection efforts of three different organizations operating a total of four aircraft and 12 ground stations. Incorporated into plans for that program were numerous quality assurance activities designed to identify potential hazards for data quality in time for their correction and to take data to allow assessment of the consistency of the data from different stations. The purpose of this study was to document QA procedures that were performed by participating agencies and revise data from all platforms for mutual compatibility. For the latter effort, cases were identified on 21 occasions on seven different days where two or more monitoring systems were operating in the same location at nearly the same time. Data from the systems involved were tabulated in 200 m altitude segments, averaged and compared to detect any bias between measurements made from different systems. The results of these comparisons along with the results of independent performance audits are presented.

White, J. H.↗

A LEO concept for millimeter wave satellite communication

A conceptual 60 satellite LEO constellation for millimeter wave communication is discussed. It could be launched in segments, with the first 30 satellites providing high elevation angles for all time in the Northern latitudes between Miami and Thule. The second set of 30 satellites would complete the worldwide coverage with emphasis on high ground elevation angles in the densely populated temperate zones. Full earth searches for all time are used to generate probability density functions for elevation angle. The density functions are used to derive optimum frequencies for random elevation systems. The 55 degree average elevation angle and 14 degree standard deviation are seen to be acceptable for 0.997 rain availability in Washington, DC for the 40 to 47 GHz region. The 40 to 47 GHz region is nearly optimum, if 0.99 rain availability is acceptable.

Jackson, A. H.↗

VentureStar(trademark) Reaping the Benefits of the X-33 Program

Major X-33 flight hardware has been delivered, and assembly of the vehicle is well underway in anticipation of its flight test program commencing in the summer of 1999. Attention has now turned to the operational VentureStar(trademark), the first single-stage-to-orbit (SSTO) reusable launch vehicle. Activities are grouped under two broad categories: (1) vehicle development and (2) market/business planning, each of which is discussed. The mission concept is presented for direct payload delivery to the International Space Station and to low Earth orbit, as well as payload delivery with an upper stage to Geosynchronous Transfer Orbit (GTO) and other high energy orbits. System requirements include flight segment and ground segment. Vehicle system sizing and design status is provided including the application of X-33 traceability and lessons learned. Technology applications to the VentureStar(trademark) are described including the structure, propellant tanks, thermal protection system, aerodynamics, subsystems, payload bay and propulsion. Developing a market driven low cost launch services system for the 21 st Century requires traditional and non-traditional ways of being able to forecast the evolution of the potential market. The challenge is balancing both the technical and financial assumptions of the market. This involves the need to provide a capability to meet market segments that in some cases are very speculative, while at the same time providing the financial community with a credible revenue stream.

Sumrall, J.↗

Mars Global Surveyor Ka-Band Frequency Data Analysis

The Mars Global Surveyor (MGS) spacecraft, launched on November 7, 1996, carries an experimental space-to-ground telecommunications link at Ka-band (32 GHz) along with the primary X-band (8.4 GHz) downlink. The signals are simultaneously transmitted from a 1.5-in diameter parabolic high gain antenna (HGA) on MGS and received by a beam-waveguide (BWG) R&D 34-meter antenna located in NASA's Goldstone Deep Space Network (DSN) complex near Barstow, California. The projected 5-dB link advantage of Ka-band relative to X-band was confirmed in previous reports using measurements of MGS signal strength data acquired during the first two years of the link experiment from December 1996 to December 1998. Analysis of X-band and Ka-band frequency data and difference frequency (f(sub x)-f(sub ka)/3.8) data will be presented here. On board the spacecraft, a low-power sample of the X-band downlink from the transponder is upconverted to 32 GHz, the Ka-band frequency, amplified to I-W using a Solid State Power Amplifier, and radiated from the dual X/Ka HGA. The X-band signal is amplified by one of two 25 W TWTAs. An upconverter first downconverts the 8.42 GHz X-band signal to 8 GHz and then multiplies using a X4 multiplier producing the 32 GHz Ka-band frequency. The frequency source selection is performed by an RF switch which can be commanded to select a VCO (Voltage Controlled Oscillator) or USO (Ultra-Stable Oscillator) reference. The Ka-band frequency can be either coherent with the X-band downlink reference or a hybrid combination of the USO and VCO derived frequencies. The data in this study were chosen such that the Ka-band signal is purely coherent with the X-band signal, that is the downconverter is driven by the same frequency source as the X-band downlink). The ground station used to acquire the data is DSS-13, a 34-meter BWG antenna which incorporates a series of mirrors inside beam waveguide tubes which guide the energy to a subterranean pedestal room, providing a stable environment for the feed and electronics equipment. A dichroic plate is used to reflect the X-band energy and pass the Ka-band energy to another mirror. The RF energy for each band is then focused onto a feed horn and low-noise amplifier package. After amplification and RF/IF downconversion, the IF signals are sent to the Experimental Tone Tracker (ETT), a digital phase-lock-loop receiver, which simultaneously tracks both X-band and Ka-band carrier signals. Once a signal is detected, the ETT outputs estimates of the SNR in a I -Hz bandwidth (Pc/No), baseband phase and frequency of the signals every I -sec. Between December 1996 and December 1998, the Ka-band and X-band signals from MGS were tracked on a regular basis using the ETT. The Ka-band downlink frequencies described here were referenced to the spacecraft's on-board USO which was also the X-band frequency reference (f(sub ka)= 3.8 f(sub x)). The ETT estimates of baseband phase at I -second sampled time tags were converted to sky frequency estimates. Frequency residuals were then generated for each band by removing a model frequency from each observable frequency at each time tag. The model included Doppler and other effects derived from spacecraft trajectory files obtained from the MGS Navigation Team. A simple troposphere correction was applied to the data. In addition to residuals, the USO frequencies emitted by the spacecraft were estimated. For several passes, the USO frequencies were determined from X-band data and from Ka-band data (referred to X-band by dividing by 3.8) and were found to be in good agreement. In addition, X-band USO frequency estimates from MGS Radio Science data acquired from operational DSN stations were available for comparison and were found to agree within the I Hz level. The remaining sub-Hertz differences were attributed to the different models and software algorithms used by MGS Radio Science and KaBLE-11. A summary of the results of a linear fit of the USO frequency versus time (day of year) is presented in Table I for an initial segment of passes.

Morabito, D.↗

Comparisons of a Three-Dimensional, Full Navier Stokes Computer Model with High Mach Number Combuster Test Data

Comparisons between scramjet combustor data and a three-dimensional full Navier-Stokes calculation have been made to verify and substantiate computational fluid dynamics (CFD) codes and application procedures. High Mach number scramjet combustor development will rely heavily on CFD applications to provide wind tunnel-equivalent data of quality sufficient to design, build and fly hypersonic aircraft. Therefore. detailed comparisons between CFD results and test data are imperative. An experimental case is presented, for which combustor wall static pressures were measured and flow-fieid interferograms were obtained. A computer model was done of the experiment, and counterpart parameters are compared with experiment. The experiment involved a subscale combustor designed and fabricated for the National Aero-Space Plane Program, and tested in the Calspan Corporation 96" hypersonic shock tunnel. The combustor inlet ramp was inclined at a 20 angle to the shock tunnel nozzle axis, and resulting combustor entrance flow conditions simulated freestream M=10. The combustor body and cowl walls were instrumented with static pressure transducers, and the combustor lateral walls contained windows through which flowfield holographic interferograms were obtained. The CFD calculation involved a three-dimensional time-averaged full Navier-Stokes code applied to the axial flow segment containing fuel injection and combustion. The full Navier-Stokes approach allowed for mixed supersonic and subsonic flow, downstream-upstream communication in subsonic flow regions, and effects of adverse pressure gradients. The code included hydrogen-air chemistry in the combustor segment which begins near fuel injection and continues through combustor exhaust. Combustor ramp and inlet segments on the combustor lateral centerline were modelled as two dimensional. Comparisons to be shown include calculated versus measured wall static pressures as functions of axial flow coordinate, and calculated path-averaged density contours versus an holographic Interferogram.

Watkins, William B.↗

Shuttle Lesson Learned - Toxicology

This is a script for a video about toxicology and the space shuttle. The first segment is deals with dust in the space vehicle. The next segment will be about archival samples. Then we'll look at real time on-board analyzers that give us a lot of capability in terms of monitoring for combustion products and the ability to monitor volatile organics on the station. Finally we will look at other issues that are about setting limits and dealing with ground based lessons that pertain to toxicology.

James, John T.↗

Effective Defect Detection Using Instance Segmentation for NDI

Ultrasonic testing is a common Non-Destructive Inspection (NDI) method used in aerospace manufacturing. However, the complexity and size of the ultrasonic scans make it challenging to identify defects through visual inspection or machine learning models. Using computer vision techniques to identify defects from ultrasonic scans is an evolving research area. In this study, we used instance segmentation to identify the presence of defects in the ultrasonic scan images of composite panels that are representative of real components manufactured in aerospace. We used two models based on Mask- RCNN (Detectron 2) and YOLO 11 respectively. Additionally, we implemented a simple statistical pre-processing technique that reduces the burden of requiring custom-tailored pre-processing techniques. Our study demonstrates the feasibility and effectiveness of using instance segmentation in the NDI pipeline by significantly reducing data pre-processing time, inspection time, and overall costs.

computer vision techniques↗

Deep Bed Iodine Sorbent Testing FY 2011 Report

Nuclear fission results in the production of fission products (FPs) and activation products that increasingly interfere with the fission process as their concentrations increase. Some of these fission and activation products tend to evolve in gaseous species during used nuclear fuel reprocessing. Analyses have shown that I129, due to its radioactivity, high potential mobility in the environment, and high longevity (half life of 15.7 million years), can require control efficiencies of up to 1,000x or higher to meet regulatory emission limits. Deep-bed iodine sorption testing has been done to evaluate the performance of solid sorbents for capturing iodine in off-gas streams from nuclear fuel reprocessing plants. The objectives of the FY 2011 deep bed iodine sorbent testing are: (1) Evaluate sorbents for iodine capture under various conditions of gas compositions and operating temperature (determine sorption efficiencies, capacities, and mass transfer zone depths); and (2) Generate data for dynamic iodine sorption modeling. Three tests performed this fiscal year on silver zeolite light phase (AgZ-LP) sorbent are reported here. Additional tests are still in progress and can be reported in a revision of this report or a future report. Testing was somewhat delayed and limited this year due to initial activities to address some questions of prior testing, and due to a period of maintenance for the on-line GC. Each test consisted of (a) flowing a synthetic blend of gases designed to be similar to an aqueous dissolver off-gas stream over the sorbent contained in three separate bed segments in series, (b) measuring each bed inlet and outlet gas concentrations of iodine and methyl iodide (the two surrogates of iodine gas species considered most representative of iodine species expected in dissolver off-gas), (c) operating for a long enough time to achieve breakthrough of the iodine species from at least one (preferably the first two) bed segments, and (d) post-test purging with pure N 2 to drive loosely or physisorbed iodine species off of the sorbent. Post-test calculations determine the control efficiencies for each bed, iodine loadings on the sorbent, and mass transfer zone depths. Portions of the iodine-laden sorbent from the first bed of two of the tests have been shipped to SNL for waste form studies. Over the past three years, we have explored a full range of inlet iodine and methyl iodide concentrations ranging from ~100 ppb to ~100 ppm levels, and shown adequate control efficiencies within a bed depth as shallow as 2 inches for lower concentrations and 4 inches for higher concentrations, for the AgZ-type sorbents. We are now performing a limited number of tests in the NC-77 sorbent from SNL. Then we plan to continue to (a) fill in data gaps needed for isotherms and dynamic sorbent modeling, and (b) test the performance of additional sorbents under development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Separation of overlapping sources in bioacoustic mixtures

Source separation is an important step to study signals that are not easy or possible to record individually. Common methods such as deep clustering, however, cannot be applied to signals of an unknown number of sources and/or signals that overlap in time and/or frequency—a common problem in bioacoustic recordings. This work presents an approach, using a supervised learning framework, to parse individual sources from a spectrogram of a mixture that contains a variable number of overlapping sources. This method isolates individual sources in the time-frequency domain using only one function but in two separate steps, one for the detection of the number of sources and corresponding bounding boxes, and a second step for the segmentation in which masks of individual sounds are extracted. This approach handles the full separation of overlapping sources in both time and frequency using deep neural networks in an applicable manner to other tasks such as bird audio detection. This paper presents method and reports on its performance to parse individual bat signals from recordings containing hundreds of overlapping bat echolocation signals. This method can be extended to other bioacoustic recordings with a variable number of sources and signals that overlap in time and/or frequency.

Izadi, Mohammad Rasool↗

The investigation of vertebral injury sustained during aircrew ejection

A series of tests were performed on excised human vertebral segments to determine the static and dynamic response of the thoraco-lumbar spine when loaded in flexion. A total of fifteen tests were performed on eleven specimens. Specimens were obtained from male donors ranging in age from 34 to 60 years. Demographic data pertinent to each specimen and the elapsed time between death of the donor and testing of each corresponding specimen are presented. Only spinal segments comprised of lower thoracic and upper lumbar vertebrae were tested because in aircraft ejection injuries clinical complications in this anatomical region predominate. A complex continuum mathematical model describing the dynamic response of the human spine was formulated, solved, and verified experimentally. Detailed results are presented in figures, tables, and equations.

Benedict, J. V.↗

Generation of Subauroral Longitudinally Extended Emissions Following Intensifications of the Poleward Boundary of the Substorm Bulge and Streamer Production

Observations showing the development of Subauroral Longitudinally Extended Emigerssions on a global scale are presented. It is demonstrated that they occur as a separation of an east-west arc-like band of luminosity that detaches away from the equatorward edge of the auroral distribution following episodes of auroral streamer production. They persist for time intervals on the order of ~30 min and devolve into patchy disjointed segments before they fade. Emissions are seen in both 557.7 nm OI and 391.4 nm N + 2 1NG lines, and 630.0 nm emissions are often observed equatorward. The 391.4 nm emissions are typically weaker and fade away more quickly than the 557.7 nm emissions, suggesting that an auroral precipitation source is initially present but is rapidly depleted as the forms age. All cases are associated with enhanced Subauroral Polarization Stream (SAPS) flows, and one event shows clear association with large-scale Giant Undulations (GUs) and the formation of spur-like forms that fold equatorward under the main oval. A model is proposed for the production of subauroral longitudinally extended forms in which nonlinear growth of SAPS-induced surface waves on the plasmapause results in a disruption of the boundary. It is suggested that hot plasma of plasma sheet origin becomes entrained in the plasmasphere to produce transient precipitation-associated auroral emissions that may decay into STEVE emissions and that cold dense plasma from the plasmasphere becomes entrained onto open drift paths to feed long-lived drainage plumes. This process may occur quasi periodically during intense substorms and storm-time conditions.

79 ASTRONOMY AND ASTROPHYSICS↗