Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

SAFIRE : Scalable and Accurate Fault Injection for Parallel Multi-threaded Applications

The software SAFIRE implements a fault injection tool to evaluate the impact of soft errors on parallel, multi-threaded applications. It implements instruction-level fault models that emulate soft errors by flipping bits in the register operands of executed machine instructions. SAFIRE is based on the LLVM compiler and utilizes novel techniques to optimize instruction instrumentation and fault injection. By detailed measurements, SAFIRE is multiple times faster than other state-of-the-art fault injection techniques, while having the same accuracy.

Georgakoudis, Giorgis↗

Power series evaluation of transition and covariance matrices.

Reexamination power series solutions to the matrix covariance differential equation and the transition differential equation. Truncation error bounds are derived which are computationally attractive and which extend previous results. Polynomial approximations are obtained by exploiting the functional equations satisfied by the transition and covariance matrices. The series-functional equation propagation technique represents a fast and accurate alternative to the numerical integration of the time-invariant transition and covariance equations.

Bierman, G. J.↗

Techniques for the analysis of geodynamic effects using laser data

New orbit computation techniques have been developed to realize the full precision of laser ranging measurements from a single tracking station used to accurately determine the orbital inclination of a satellite. In order to evaluate earth and ocean tidal effects on the satellite and polar motion effects on the station latitude, improved computational techniques are described for perturbations significantly influencing the satellite's inclination, such as solar radiation pressure and geopotential resonance. By using the time independent value of maximum latitude reached by the satellite as the experimental variable, orbit tracking errors caused by imprecise modelling of the gravity field and atmospheric drag have been largely overcome and made possible long term analysis of osculating elements. With these techniques, quarter day spans of laser data have been employed to monitor the inclination of the satellite to the order 0.01 arcseconds precision over a period of seventeen months.

Dunn, P. J.↗

Evaluation of force-torque displays for use with space station telerobotic activities

Recent experiments which addressed Space Station remote manipulation tasks found that tactile force feedback (reflecting forces and torques encountered at the end-effector through the manipulator hand controller) does not improve performance significantly. Subjective response from astronaut and non-astronaut test subjects indicated that force information, provided visually, could be useful. No research exists which specifically investigates methods of presenting force-torque information visually. This experiment was designed to evaluate seven different visual force-torque displays which were found in an informal telephone survey. The displays were prototyped in the HyperCard programming environment. In a within-subjects experiment, 14 subjects nullified forces and torques presented statically, using response buttons located at the bottom of the screen. Dependent measures included questionnaire data, errors, and response time. Subjective data generally demonstrate that subjects rated variations of pseudo-perspective displays consistently better than bar graph and digital displays. Subjects commented that the bar graph and digital displays could be used, but were not compatible with using hand controllers. Quantitative data show similar trends to the subjective data, except that the bar graph and digital displays both provided good performance, perhaps do to the mapping of response buttons to display elements. Results indicate that for this set of displays, the pseudo-perspective displays generally represent a more intuitive format for presenting force-torque information.

Hendrich, Robert C.↗

Psychophysiology of Spaceflight and Aviation

In space, the absence of gravity alone causes unique physiological stress. Significant biomedical changes, across multiple organ systems, such as body fluid redistribution, diminished musculoskeletal strength, changes in cardiac function and sensorimotor control have been reported. The time course of development of these disorders and severity of symptoms experienced by individuals varies widely. Space motion sickness (SMS) is an example of maladaptation to microgravity, which occurs early in the mission and can have profound effects on physical health and crew performance. Disturbances in sleep quality, perception, emotional equilibrium and mood have also been reported, with impact to health and performance varying widely across individuals. And lastly, post-flight orthostatic intolerance, low blood pressure experienced after returning to Earth, is also of serious concern. Both the Russian and American space programs have a varied list of human errors and mistakes, which adversely impacted mission goals. Continued probability of human exposure to microgravity for extended time periods provides a rationale for the study of the effects of stress. The primary focus of this research group is directed toward examining individual differences in: (a) prediction of susceptibility to these disorders, (b) assessment of symptom severity, (c) evaluation of the effectiveness of countermeasures, and (d) developing and testing a physiological training method, Autogenic-Feedback Training Exercise (AFTE) as a countermeasure with multiple applications. The present paper reports on the results of a series of human flight experiments with AFTE aboard the Space Shuttle and Mir Space Station, and during emergency flight scenarios on Earth.

Cowings, Patricia↗

Filter Tuning Using the Chi-Squared Statistic

The Goddard Space Flight Center (GSFC) Flight Dynamics Facility (FDF) performs orbit determination (OD) for the Aqua and Aura satellites. Both satellites are located in low Earth orbit (LEO), and are part of what is considered the A-Train satellite constellation. Both spacecraft are currently in the science phase of their respective missions. The FDF has recently been tasked with delivering definitive covariance for each satellite.The main source of orbit determination used for these missions is the Orbit Determination Toolkit developed by Analytical Graphics Inc. (AGI). This software uses an Extended Kalman Filter (EKF) to estimate the states of both spacecraft. The filter incorporates force modelling, ground station and space network measurements to determine spacecraft states. It also generates a covariance at each measurement. This covariance can be useful for evaluating the overall performance of the tracking data measurements and the filter itself. An accurate covariance is also useful for covariance propagation which is utilized in collision avoidance operations. It is also valuable when attempting to determine if the current orbital solution will meet mission requirements in the future.This paper examines the use of the Chi-square statistic as a means of evaluating filter performance. The Chi-square statistic is calculated to determine the realism of a covariance based on the prediction accuracy and the covariance values at a given point in time. Once calculated, it is the distribution of this statistic that provides insight on the accuracy of the covariance.For the EKF to correctly calculate the covariance, error models associated with tracking data measurements must be accurately tuned. Over estimating or under estimating these error values can have detrimental effects on the overall filter performance. The filter incorporates ground station measurements, which can be tuned based on the accuracy of the individual ground stations. It also includes measurements from the NASA space network (SN), which can be affected by the assumed accuracy of the TDRS satellite state at the time of the measurement.The force modelling in the EKF is also an important factor that affects the propagation accuracy and covariance sizing. The dominant force in the LEO orbit regime is the drag force caused by atmospheric drag. Accurate accounting of the drag force is especially important for the accuracy of the propagated state. The implementation of a box and wing model to improve drag estimation accuracy, and its overall effect on the covariance state is explored.The process of tuning the EKF for Aqua and Aura support is described, including examination of the measurement errors of available observation types (Doppler and range), and methods of dealing with potentially volatile atmospheric drag modeling. Predictive accuracy and the distribution of the Chi-square statistic, calculated based of the ODTK EKF solutions, are assessed versus accepted norms for the orbit regime.

Covariance Analysis↗

Synoptic Mapping of Chemical Composition, Thermal Structure, and Air Motion from UARS Observations

An operational mapping algorithm was developed to process measurements of individual species observed by different satellite instruments on board UARS. Based on Fast Fourier Synoptic Mapping (FFSM), the algorithm accounts for the precessing orbit of UARS, the error of individual instruments, and gaps associated with instrument duty cycle and the satellite yaw maneuver. It provides synoptic structure and evolution on periods as short as 1 day, derived collectively from all observations of an individual species. The algorithm was applied to synoptically map temperature, thickness, and several chemical constituents observed by the instruments: MLS, CLAES, ISAMS, and HALOE. Each field variable observed by these instruments was mapped twice-daily in continuous global time series several months long. Mapped behavior produced via FFSM was compared against standard archived products generated via Kalman filtering. The standard map products reveal similar behavior, but are limited to features of larger scale. Tracer structure that develops through flow deformation and attending transport is therefore represented in those products more coarsely, eventually being sheared down to scales that are no longer represented properly. The synoptic time series also reveal a diurnal cycle for several of the constituents, one that emerges clearly in their space-time spectra. The zonal and meridional structure of diurnal variability was mapped by filtering the space-time spectrum, an intermediate product of FFSM, to those scales resolved by the UARS sampling. Geographical variations of the diurnal cycle have also been evaluated in its seasonal-mean structure by compositing distributions at individual local times. Both were compared to diurnal variations in chemical models and in dynamical models that account for transport by the diurnal tide. Diurnal variations were found to introduce spurious behavior into the archived products generated via Kalman filtering, behavior that is misrepresented in those synoptic time series. Aliasing by under-sampled diurnal variations introduces a bias into the time-mean structure of archived products. That systematic error is manifested as anomalous wave structure in the time-mean fields. By contrast, synoptic time series generated via FFSM faithfully represent such behavior as varying diurnally, so it does not corrupt time-mean structure. Tracer structure mapped via the above algorithm was being applied to determine the Brewer-Dobson circulation of the stratosphere through Lagrangian considerations. Preliminary results are encouraging: They reveal diabatic ascent in the tropics, balanced by diabatic descent over the winter hemisphere. This Lagrangian description of transport derived from UARS tracer measurements would be potentially valuable for diagnosing interannual changes of transport, specifically, in relation to interannual changes of total ozone. Regrettably, support was reduced to 50% of the approved funding level, leaving this component incomplete.

Salby, Murry L.↗

WE-A-17A-10: Fast, Automatic and Accurate Catheter Reconstruction in HDR Brachytherapy Using An Electromagnetic 3D Tracking System

Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.

07 ISOTOPE AND RADIATION SOURCES↗

MPST Software: grl_pef_check

This innovation is a tool used to verify and validate spacecraft sequences at the predicted events file (PEF) level for the GRAIL (Gravity Recovery and Interior Laboratory, see http://www.nasa. gov/mission_pages/grail/main/index. html) mission as part of the Multi-Mission Planning and Sequencing Team (MPST) operations process to reduce the possibility for errors. This tool is used to catch any sequence related errors or issues immediately after the seqgen modeling to streamline downstream processes. This script verifies and validates the seqgen modeling for the GRAIL MPST process. A PEF is provided as input, and dozens of checks are performed on it to verify and validate the command products including command content, command ordering, flight-rule violations, modeling boundary consistency, resource limits, and ground commanding consistency. By performing as many checks as early in the process as possible, grl_pef_check streamlines the MPST task of generating GRAIL command and modeled products on an aggressive schedule. By enumerating each check being performed, and clearly stating the criteria and assumptions made at each step, grl_pef_check can be used as a manual checklist as well as an automated tool. This helper script was written with a focus on enabling the user with the information they need in order to evaluate a sequence quickly and efficiently, while still keeping them informed and active in the overall sequencing process. grl_pef_check verifies and validates the modeling and sequence content prior to investing any more effort into the build. There are dozens of various items in the modeling run that need to be checked, which is a time-consuming and errorprone task. Currently, no software exists that provides this functionality. Compared to a manual process, this script reduces human error and saves considerable man-hours by automating and streamlining the mission planning and sequencing task for the GRAIL mission.

Call, Jared A.↗

Flight Crew Workload, Acceptability, and Performance When Using Data Comm in a High-Density Terminal Area Simulation

This document describes a collaborative FAA/NASA experiment using 22 commercial airline pilots to determine the effect of using Data Comm to issue messages during busy, terminal area operations. Four conditions were defined that span current day to future flight deck equipage: Voice communication only, Data Comm only, Data Comm with Moving Map Display, and Data Comm with Moving Map displaying taxi route. Each condition was used in an arrival and a departure scenario at Boston Logan Airport. Of particular interest was the flight crew response to D-TAXI, the use of Data Comm by Air Traffic Control (ATC) to send taxi instructions. Quantitative data was collected on subject reaction time, flight technical error, operational errors, and eye tracking information. Questionnaires collected subjective feedback on workload, situation awareness, and acceptability to the flight crew for using Data Comm in a busy terminal area. Results showed that 95% of the Data Comm messages were responded to by the flight crew within one minute and 97% of the messages within two minutes. However, post experiment debrief comments revealed almost unanimous consensus that two minutes was a reasonable expectation for crew response. Flight crews reported that Expected D-TAXI messages were useful, and employment of these messages acceptable at all altitude bands evaluated during arrival scenarios. Results also indicate that the use of Data Comm for all evaluated message types in the terminal area was acceptable during surface operations, and during arrivals at any altitude above the Final Approach Fix, in terms of response time, workload, situation awareness, and flight technical performance. The flight crew reported the use of Data Comm as implemented in this experiment as unacceptable in two instances: in clearances to cross an active runway, and D-TAXI messages between the Final Approach Fix and 80 knots during landing roll. Critical cockpit tasks and the urgency of out-the window scan made the additional head down time to respond to Data Comm messages undesirable during these events. However, most crews also stated that Data Comm messages without an accompanying audio chime and no expectation of an immediate response could be acceptable even during these events.

Norman, R. Michael↗

Fast Fault Injection and Sensitivity Analysis for Collective Communications, In: 2015 IEEE International Conference on Cluster Computing

The collective communication operations, which are widely used in parallel applications for global communication and synchronization are critical for application's performance and scalability. However, how faulty collective communications impact the application and how errors propagate between the application processes is largely unexplored. One of the critical reasons for this situation is the lack of fast evaluation method to investigate the impacts of faulty collective operations. The traditional random fault injection methods relying on a large amount of fault injection tests to ensure statistical significance require a significant amount of resources and time. These methods result in prohibitive evaluation cost when applied to the collectives. In this paper, we introduce a novel tool named Fast Fault Injection and Sensitivity Analysis Tool (FastFIT) to conduct fast fault injection and characterize the application sensitivity to faulty collectives. The tool achieves fast exploration by reducing the exploration space and predicting the application sensitivity using Machine Learning (ML) techniques. A basis for these techniques are implicit correlations between MPI semantics, application context, critical application features, and application responses to faulty collective communications. The experimental results show that our approach reduces the fault injection points and tests by 97% for representative benchmarks (NAS Parallel Benchmarks (NPB)) and a realistic application (Large-scale Atomic/Molecular Massively Parallel Simulator (LAMMPS)) on a production supercomputer. Further, we statistically generalize the application sensitivity to faulty collective communications for these workloads, and present correlation between application features and the sensitivity.

Computer Science↗

Forecasting longitudinal changes in oropharyngeal tumor morphology throughout the course of head and neck radiation therapy

Purpose: To create models that forecast longitudinal trends in changing tumor morphology and to evaluate and compare their predictive potential throughout the course of radiation therapy. Methods: Two morphology feature vectors were used to describe 35 gross tumor volumes (GTVs) throughout the course of intensity-modulated radiation therapy for oropharyngeal tumors. The feature vectors comprised the coordinates of the GTV centroids and a description of GTV shape using either interlandmark distances or a spherical harmonic decomposition of these distances. The change in the morphology feature vector observed at 33 time points throughout the course of treatment was described using static, linear, and mean models. Models were adjusted at 0, 1, 2, 3, or 5 different time points (adjustment points) to improve prediction accuracy. The potential of these models to forecast GTV morphology was evaluated using leave-one-out cross-validation, and the accuracy of the models was compared using Wilcoxon signed-rank tests. Results: Adding a single adjustment point to the static model without any adjustment points decreased the median error in forecasting the position of GTV surface landmarks by the largest amount (1.2 mm). Additional adjustment points further decreased the forecast error by about 0.4 mm each. Selection of the linear model decreased the forecast error for both the distance-based and spherical harmonic morphology descriptors (0.2 mm), while the mean model decreased the forecast error for the distance-based descriptor only (0.2 mm). The magnitude and statistical significance of these improvements decreased with each additional adjustment point, and the effect from model selection was not as large as that from adding the initial points. Conclusions: The authors present models that anticipate longitudinal changes in tumor morphology using various models and model adjustment schemes. The accuracy of these models depended on their form, and the utility of these models includes the characterization of patient-specific response with implications for treatment management and research study design.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-09: Respiratory Motion Correction in 4D-PET by Simultaneous Motion Estimation and Image Reconstruction (SMEIR)

Purpose: In conventional 4D-PET, images from different frames are reconstructed individually and aligned by registration methods. Two issues with these approaches are: 1) Reconstruction algorithms do not make full use of all projections statistics; and 2) Image registration between noisy images can Result in poor alignment. In this study we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) method for cone beam CT for motion estimation/correction in 4D-PET. Methods: Modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM- TV) is used to obtain a primary motion-compensated PET (pmc-PET) from all projection data using Demons derived deformation vector fields (DVFs) as initial. Motion model update is done to obtain an optimal set of DVFs between the pmc-PET and other phases by matching the forward projection of the deformed pmc-PET and measured projections of other phases. Using updated DVFs, OSEM- TV image reconstruction is repeated and new DVFs are estimated based on updated images. 4D XCAT phantom with typical FDG biodistribution and a 10mm diameter tumor was used to evaluate the performance of the SMEIR algorithm. Results: Image quality of 4D-PET is greatly improved by the SMEIR algorithm. When all projections are used to reconstruct a 3D-PET, motion blurring artifacts are present, leading to a more than 5 times overestimation of the tumor size and 54% tumor to lung contrast ratio underestimation. This error reduced to 37% and 20% for post reconstruction registration methods and SMEIR respectively. Conclusion: SMEIR method can be used for motion estimation/correction in 4D-PET. The statistics is greatly improved since all projection data are combined together to update the image. The performance of the SMEIR algorithm for 4D-PET is sensitive to smoothness control parameters in the DVF estimation step.

60 APPLIED LIFE SCIENCES↗

Self-Supervised T-GCN for Detection of Disturbance and Propagation in Power Grid

Urban power systems increasingly rely on dense sensing to monitor grid reliability, yet disturbance labels are scarce and events are rare. We present a self-supervised spatio-temporal method that detects, localizes, and characterizes grid frequency disturbances across urban areas using only unlabeled data. Our approach trains a tiny Temporal Graph Convolutional Network (T-GCN) to forecast per-site frequency residuals (deviation from 60 Hz). The sensor graph is constructed directly from signals using pre-event Pearson correlation with a cross-correlation lag penalty without geocoding. At inference, node-level anomalies are the model's forecast errors; region-level alarms arise from connected components of high-score nodes. We estimate disturbance propagation by computing per-node arrival times (first persistent exceedance), then fit a planar or time-of-arrival model to obtain direction, speed, and an epicenter proxy. With only three real events collected at decisecond resolution across U.S. cities, we evaluate the T-GCN and report time-to-detect, footprint size, and propagation consistency. We further show that short-window embeddings from the T-GCN's hidden states enable few-shot event-vs-background recognition via a simple prototypical classifier. Despite minimal data and no labels, our system yields fast, spatially coherent detection and interpretable propagation maps, offering a practical, lightweight pathway to city-scale grid resilience analytics.

Niu, Haoran [ORNL] (ORCID:0000000155228297)↗

LANDSAT-4 MSS Geometric Correction: Methods and Results

An automated image registration system such as that developed for LANDSAT-4 can produce all of the information needed to verify and calibrate the software and to evaluate system performance. The on-line MSS archive generation process which upgrades systematic correction data to geodetic correction data is described as well as the control point library build subsystem which generates control point chips and support data for on-line upgrade of correction data. The system performance was evaluated for both temporal and geodetic registration. For temporal registration, 90% errors were computed to be .36 IFOV (instantaneous field of view) = 82.7 meters) cross track, and .29 IFOV along track. Also, for actual production runs monitored, the 90% errors were .29 IFOV cross track and .25 IFOV along track. The system specification is .3 IFOV, 90% of the time, both cross and along track. For geodetic registration performance, the model bias was measured by designating control points in the geodetically corrected imagery.

Brooks, J.↗

Processing Spacecraft Data Without Confusion

Producing multiple versions of the same data product for the same time frame with the same remotely sensed inputs can be a recipe for disaster. Yet, amidst the commotion of satellite launch and early operations (LEO), such data processing is needed. After LEO, the situation gets worse. Processing newly arriving data ("forward processing") is augmented with reprocessing and algorithm development, comparison, evaluation, and testing -- often happening all at the same time. The problem can be analyzed in three main parts -- maintaining multiple versions of algorithms and data so that end-product users are not overwhelmed,allocating computer resources efficiently, and simplifying production operations so that va st amounts of data can be processed with minimal staff and fewer errors. OMIDAPS provides a framework for execution of algorithms that transform lower level data acquired by OMI on NASA's Aura satellite into higher level science data products. In contrast to traditional science data processing systems, we address all parts of the problem with an innovative approach allowing multiple data processing to run within a single physical system. The data products, imports, exports, and execution planning are all segregated into distinct "ArchiveSets." This paper describes reasons for multiple concurrent productions on a typical satellite data processing project using OMI as an example. It describes the virtual data processing system concept and its advantages over separate physical processing strings. It explores the specific implementation of the virtual systems within OMIDAPS and discusses some of the implications of our approach and describes how virtual processing is used to accomplish the overall mission of OMI data processing.

Tilmes, Curt↗

Implementation of Active Thermal Control (ATC) for the Soil Moisture Active and Passive (SMAP) Radiometer

NASA's Earth Observing Soil Moisture Active and Passive (SMAP) Mission is scheduled to launch in November 2014 into a 685 kilometer near-polar, sun-synchronous orbit. SMAP will provide comprehensive global mapping measurements of soil moisture and freeze/thaw state in order to enhance understanding of the processes that link the water, energy, and carbon cycles. The primary objectives of SMAP are to improve worldwide weather and flood forecasting, enhance climate prediction, and refine drought and agriculture monitoring during its three year mission. The SMAP instrument architecture incorporates an L-band radar and an L-band radiometer which share a common feed horn and parabolic mesh reflector. The instrument rotates about the nadir axis at approximately 15 revolutions per minute, thereby providing a conically scanning wide swath antenna beam that is capable of achieving global coverage within three days. In order to make the necessary precise surface emission measurements from space, the electronics and hardware associated with the radiometer must meet tight short-term (instantaneous and orbital) and long-term (monthly and mission) thermal stabilities. Maintaining these tight thermal stabilities is quite challenging because the sensitive electronics are located on a fast spinning platform that can either be in full sunlight or total eclipse, thus exposing them to a highly transient environment. A passive design approach was first adopted early in the design cycle as a low-cost solution. With careful thermal design efforts to cocoon and protect all sensitive components, all stability requirements were met passively. Active thermal control (ATC) was later added after the instrument Preliminary Design Review (PDR) to mitigate the threat of undetected gain glitches, not for thermal-stability reasons. Gain glitches are common problems with radiometers during missions, and one simple way to avoid gain glitches is to use the in-flight set point programmability that ATC affords to operate the radiometer component away from the problematic temperature zone. A simple ThermXL model (10 nodes) was developed to exercise quick trade studies among various proposed control algorithms: Modified P control vs. PI control. The ThermXL results were then compared with the detailed Thermal Desktop (TD) model for corroboration. Once done, the simple ThermXL model was used to evaluate parameter effects such as temperature digitization, heater size and gain margin, time step, and voltage variation of power supply on the ATC performance. A Modified P control algorithm was implemented into the instrument flight electronics based on the ThermXL results. The thermal short-term stability margin decreased by 10 percent with ATC and a wide temperature error band (plus or minus 0.1 degrees Centigrade) compared to the original passive thermal design. However, a tighter temperature error band (plus or minus 0.1 degrees Centigrade) increased the thermal short-term stability margin by a factor of three over the passive thermal design. The current ATC design provides robust thermal control, tighter stability, and greater in-flight flexibility even though its implementation was prompted by non-thermal performance concerns.

Mikhaylov, Rebecca↗

Towards the 1 mm/y Stability of the Radial Orbit Error at Regional Scales

An estimated orbit error budget for the Jason-1 and Jason-2 GDR-D solutions is constructed, using several measures of orbit error. The focus is on the long-term stability of the orbit time series for mean sea level applications on a regional scale. We discuss various issues related to the assessment of radial orbit error trends; in particular this study reviews orbit errors dependent on the tracking technique, with an aim to monitoring the long-term stability of all available tracking systems operating on Jason-1 and Jason-2 (GPS, DORIS, SLR). The reference frame accuracy and its effect on Jason orbit is assessed. We also examine the impact of analysis method on the inference of Geographically Correlated Errors as well as the significance of estimated radial orbit error trends versus the time span of the analysis. Thus a long-term error budget of the 10-year Jason-1 and Envisat GDR-D orbit time series is provided for two time scales: interannual and decadal. As the temporal variations of the geopotential remain one of the primary limitations in the Precision Orbit Determination modeling, the overall accuracy of the Jason-1 and Jason-2 GDR-D solutions is evaluated through comparison with external orbits based on different time-variable gravity models. This contribution is limited to an East-West "order-1" pattern at the 2 mm/y level (secular) and 4 mm level (seasonal), over the Jason-2 lifetime. The possibility of achieving sub-mm/y radial orbit stability over interannual and decadal periods at regional scales and the challenge of evaluating such an improvement using in situ independent data is discussed.

Precision Orbit Determination (POD)↗