Search NASA⌕ Search

SEARCH · Search NASA

Results for “ventilation controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Use of Thermoregulatory Models to Enhance Space Shuttle and Space Station operations and Review of Human Thermoregulatory Control

Thermoregulation in the space environment is critical for survival, especially in off- nominal operations. In such cases, mathematical models of thermoregulation are frequently employed to evaluate safety-of-flight issues in various human mission scenarious. In this study, the 225-node Wissler model and the 41-Node Metabolic Man model are employed to evaluate the effects of such a scenario. Metabolic loads on astronauts wearing the advanced crew escape suit (ACES) and liquid cooled ventilation garment (LCVG) are imposed on astronauts exposed to elevated cabin temperatures resulting from a systems failure. The study indicates that the performance of the ACES/LCVG cooling system is marginal. Increases in workload and or cabin temperature above nominal will increase rectal temperature, stored heat load, heart rate, and sweating, which could lead to deficits in the performance of cognitive and motor tasks. This is of concern as the ACES/LCVG is employed during Shuttle decent when the likelihood of a safe landing may be compromised. The study indicates that the most effective mitigation strategy would be to decrease the LCVG inlet temperature.

Pisacane, V. L.↗

Coupling fast fluid dynamics and multizone airflow models in Modelica Buildings library to simulate the dynamics of HVAC systems

Multizone models are widely used in building airflow and energy performance simulations due to their fast computing speed. However, multizone models assume that the air in a room is well mixed, consequently limiting their application. In specific rooms where this assumption fails, the use of computational fluid dynamics (CFD) models may be an alternative option. Previous research has mainly focused on coupling CFD models and multizone models to study airflow in large spaces. While significant, most of these analyses did not consider the coupled simulation of the building airflow with the building’s Heating, Ventilation, and Air-Conditioning (HVAC) systems. This paper tries to fill the gap by integrating the models for HVAC systems with coupled multizone and CFD simulations for airflows, using the Modelica simulation platform. To improve the computational efficiency, we incorporated a simplified CFD model named fast fluid dynamics (FFD). We first introduce the data synchronization strategy and implementation in Modelica. Then, we verify the implementation using two case studies involving an isothermal and a non-isothermal flow by comparing model simulations to experiment data. Afterward, we study another three cases that are deemed more realistic. Furthermore, this is done by attaching a variable air volume (VAV) terminal box and a VAV system to previous flows to assess the capability of the models in studying the dynamic control of HVAC systems. Finally, we discuss further research needs on the coupled simulation using the models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

Simulated Lunar Testing of Metabolic Heat Regenerated Temperature Swing Adsorption

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. An Engineering Development Unit (EDU) of the MTSA Subassembly (MTSAS) was designed and assembled for optimized Martian operations, but also meets system requirements for lunar operations. For lunar operations the MTSA sorption cycle is driven via a vacuum swing between suit ventilation loop pressure and lunar vacuum. The focus of this effort was testing in a simulated lunar environment. This environment was simulated in Paragon's EHF vacuum chamber. The objective of the testing was to evaluate the full cycle performance of the MTSA Subassembly EDU, and to assess CO2 loading and pressure drop of the wash coated aluminum reticulated foam sorbent bed. Lunar environment testing proved out the feasibility of pure vacuum swing operation, making MTSA a technology that can be tested and used on the Moon prior to going to Mars. Testing demonstrated better than expected CO2 Nomenclature loading on the sorbent and nearly replicates the equilibrium data from the sorbent manufacturer. This exceeded any of the previous sorbent loading tests performed by Paragon. Subsequently, the increased performance of the sorbent bed design indicates future designs will require less mass and volume than the current EDU rendering MTSA as very competitive for Martian PLSS applications.

Padilla, Sebastian A.↗

Space Suit Portable Life Support System Test Bed (PLSS 1.0) Development and Testing

A multi-year effort has been carried out at NASA-JSC to develop an advanced extra-vehicular activity Portable Life Support System (PLSS) design intended to further the current state of the art by increasing operational flexibility, reducing consumables, and increasing robustness. Previous efforts have focused on modeling and analyzing the advanced PLSS architecture, as well as developing key enabling technologies. Like the current International Space Station Extra-vehicular Mobility Unit PLSS, the advanced PLSS comprises three subsystems required to sustain the crew during extra-vehicular activity including the Thermal, Ventilation, and Oxygen Subsystems. This multi-year effort has culminated in the construction and operation of PLSS 1.0, a test bed that simulates full functionality of the advanced PLSS design. PLSS 1.0 integrates commercial off the shelf hardware with prototype technology development components, including the primary and secondary oxygen regulators, Ventilation Subsystem fan, Rapid Cycle Amine swingbed carbon dioxide and water vapor removal device, and Spacesuit Water Membrane Evaporator heat rejection device. The overall PLSS 1.0 test objective was to demonstrate the capability of the Advanced PLSS to provide key life support functions including suit pressure regulation, carbon dioxide and water vapor removal, thermal control and contingency purge operations. Supplying oxygen was not one of the specific life support functions because the PLSS 1.0 test was not oxygen rated. Nitrogen was used for the working gas. Additional test objectives were to confirm PLSS technology development components performance within an integrated test bed, identify unexpected system level interactions, and map the PLSS 1.0 performance with respect to key variables such as crewmember metabolic rate and suit pressure. Successful PLSS 1.0 testing completed 168 test points over 44 days of testing and produced a large database of test results that characterize system level and component performance. With the exception of several minor anomalies, the PLSS 1.0 test rig performed as expected; furthermore, many system responses trended in accordance with pre-test predictions.

Watts, Carly↗

Pilot Implementation of a Field Study Design to Evaluate the Impact of Source Control Measures on Indoor Air Quality in High Performance Homes

To improve the indoor air quality in new, high performance homes, a variety of standards and rating programs have been introduced to identify building materials that are designed to have lower emission rates of key contaminants of concern and a number of building materials are being introduced that are certified to these standards. For example, the U.S. Department of Energy (DOE) Zero Energy Ready Home program requires certification under the U.S. Environmental Protection Agency (EPA) Indoor airPLUS (IaP) label, which requires the use of PS1 or PS2 certified plywood and OSB; low-formaldehyde emitting wood products; low- or no-VOC paints and coatings as certified by Green Seal Standard GS-11, GreenGuard, SCS Indoor Advantage Gold Standard, MPI Green Performance Standard, or another third party rating program; and Green Label-certified carpet and carpet cushions. However, little is known regarding the efficacy of the IAP requirements in measurably reducing contaminant exposures in homes. The goal of this project is to develop a robust experimental approach and collect preliminary data to support the evaluation of indoor air quality (IAQ) measures linked to IAP-approved low-emitting materials and finishes in new residential homes. To this end, the research team of Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) developed a detailed experimental plan to measure IAQ constituents and other parameters, over time, in new homes constructed with materials compliant with IAP’s low-emitting material and ventilation requirements (i.e., section 6.1, 6.2, 6.3, and 7.2) and similar homes constructed to the state building code with conventional materials. The IAQ in IAP and conventional homes of similar age, location, and construction style is quantified as the differences in the speciated VOC and aldehyde concentrations, normalized to dilution rates. The experimental plan consists of methods to evaluate the difference between low-emitting and “conventional” materials as installed in newly constructed residential homes using both (1) highly controlled, short-term active samples to precisely characterize the building-related chemical emissions and building contents and (2) a week-long passive sample designed to capture the impact of occupant behavior and related activities on measured IAQ contaminant levels indoors. The combination of detailed short-term measurements with the home under controlled/consistent conditions during pre- and post-occupancy and the week-long passive sampling data provide the opportunity to begin to separate the different emission sources and help isolate and quantify variability in the monitored homes. Between April and August 2014, the research team performed pre-occupancy and post-occupancy sampling in one conventional home and two homes built with low-emitting materials that were generally consistent with EPA’s Indoor airPLUS guidelines. However, for a number of reasons, the full experimental plan was not implemented. The project was intended to continue for up to three years to asses long-term changes in IAQ but the project was limited to one calendar year. As a result, several of the primary research questions related to seasonal impacts and the long-term trends in IAQ could not be addressed. In addition, there were several unexpected issues related to recruiting, availability of home types, and difficulty coordinating with builders/realtors/homeowners. Several field monitoring issues also came up that provide “lessons learned” that led to improvements to the original monitoring plan. The project produced a good experimental plan that is expected to be be useful for future efforts collecting data to support answering these same or similar research questions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transactive HVAC Agent - Design and Performance Evaluation

Transactive energy systems are playing an increasingly important role in the efficient and reliable marketbased operation of the power grid. Since a significant portion of the residential building energy consumption is from heating ventilation and air conditioning (HVAC) systems, HVAC is one of the most promising resources to provide load flexibility. However, utilizing HVAC flexibility to provide various grid services while simultaneously maintaining consumer comfort and cost-reductions is challenging. This paper presents a design of a transactive HVAC agent (T-HVAC) to be used as a supervisory control for the HVAC system that can simultaneously ensure comfort and cost-reduction. In particular, the T-HVAC a) estimates HVAC thermal dynamics, b) ensures optimal operations of the HVAC system, and c) participates into markets, and d) implements a market-based control via controlling the thermostat temperature set-point. The T-HVAC performance is demonstrated through multiple scenarios and illustrations.

Demand flexibility, distribution system, HVAC, Tra↗

Pilot Testing of Commercial Refrigeration-Based Demand Response

Supermarkets potentially offer a substantial demand response (DR) resource because of their high energy intensity and use patterns. This report describes a pilot project conducted to better estimate supermarket DR potential. Previous work has analyzed supermarket DR using heating, ventilating, and air conditioning (HVAC), lighting, and anti-condensate heaters. This project was concerned with evaluating DR using the refrigeration system and quantifying the DR potential inherent in supermarket refrigeration systems. Ancillary aims of the project were to identify practical barriers to the implementation of DR programs in supermarkets and to determine which high-level control strategies were most appropriate for achieving certain DR objectives. The scope of this project does not include detailed control strategy development for DR or development of a strategy for regional implementation of DR in supermarkets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Equivalent Thermal Resistance of Tile Roofs with and without Batten Systems

Clay and concrete tile roofs were installed on a fully instrumented attic test facility operating in East Tennessee s climate. Roof, attic and deck temperatures and heat flows were recorded for each of the tile roofs and also on an adjacent attic cavity covered with a conventionally pigmented and direct-nailed asphalt shingle roof. The data were used to benchmark a computer tool for simulation of roofs and attics and the tool used to develop an approach for computing an equivalent seasonal R-value for sub-tile venting. The approach computed equal heat fluxes through the ceilings of roofs having different combinations of surface radiation properties and or building constructions. A direct nailed shingle roof served as a control for estimating the equivalent thermal resistance of the air space. Simulations were benchmarked to data in the ASHRAE Fundamentals for the thermal resistance of inclined and closed air spaces.

attic↗

Autonomous Anomaly Detection for MPC Forecasts of HVAC Systems in Residential Communities

The use of residential heating, ventilation, and air conditioning (HVAC) to shift peak demand or provide ancillary services is a potential solution in the presence of older grids and distributed renewables. However, to ensure the efficient use of devices, utilities need to accurately forecast the load and adopt error correction schemes when necessary. While significant theoretical research exists in the area of predictive control of HVAC, little experimental evidence exists. The lack of experimental data in turn causes researchers to be unprepared for unsystematic errors which emerge due to the higher complexity of the data generating process. This study offers an anomaly detection methodology that uses unsupervised machine learning algorithms to detect and isolate these errors with different forecast error ranges. The results of anomaly detection procedure can then be used for error correction and would eventually help develop better predictive controllers. The methodology is tested using real world data from a smart neighborhood that currently operates in Atlanta. GA.

Lebakula, Viswadeep↗

Expert System For Heat Exchanger

Diagnosis simplified for non-engineers. Developmental expert-system computer program assists operator in controlling, monitoring operation, diagnosing malfunctions, and ordering repairs of heat-exchanger system dissipating heat generated by 20-kW radio transmitter. System includes not only heat exchanger but also pumps, fans, sensors, valves, reservoir, and associated plumbing. Program conceived to assist operator while avoiding cost of keeping engineer in full-time attendance. Similar programs developed for heating, ventilating, and air-conditioning systems.

Bagby, D. Gordon↗

Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC). Vista Photonics developed the core technology and built the sensor. Nanoracks designed, constructed the enclosure, interfaces, and battery power management circuitry, integrated all subsystems into the enclosure, and then managed the certification tests, documentation and manifesting. The unit was calibrated in the JSC Toxicology Laboratory. The Multi-Gas Monitor is manifested to fly as a technology demonstration to the ISS in November 2013 and will operate for at least 6 months with data sent to the ground for evaluation. The primary goal is to demonstrate long term interference free operation in the real spacecraft environment.

Pilgrim, Jeffrey S.↗

Method and apparatus for reduction of water re-evaporation in a dedicated dehumidifier/water heater

An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.

42 ENGINEERING↗

Method and apparatus for reduction of water re-evaporation in a dedicated dehumidifier/water heater

An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.

Uselton, Robert B.↗

AN APPROACH TO BRINGING AUTOMATED FAULT DETECTION AND DIAGNOSIS (AFDD) TOOLS FOR HVAC&R INTO THE MAINSTREAM

Heating, ventilation and air-conditioning (HVAC) systems can consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. in commercial buildings. Additionally, commercial refrigeration (R) systems add about 2 quads to commercial buildings energy consumption. Most HVAC systems have one or more faults (low/high refrigerant charge, valve leakage, condenser/evaporator fouling, filter/dryer restriction, economizer faults, controls faults) that result in increased energy consumption. Automated fault detection and diagnosis (AFDD) tools have been developed to address this national issue and many tools are commercially available. AFDD tools have the potential to save considerable energy for existing commercial RTUs, chillers and refrigeration systems. These devices can be used for both retro commissioning, and, when faults are addressed, continuous commissioning as well. However, there appears to be multiple market barriers for this technology. A key market barrier for this technology is the lack of awareness of AFDD products among potential customers. Most HVAC contractors are not familiar with the latest AFDD technologies and HVAC technicians lack skills regarding these technologies. Quantifying potential benefits to building owners is difficult since there are several FDD tools with varying capabilities. For instance, there are several FDD products ranging from handling just economizer faults to those that also handle full-blown refrigerant-side and air-side faults. Methods/algorithms used in FDD vary significantly. Even though there are efforts to develop standards, currently there are no standards/methods to define functions, capabilities, accuracy, and reliability of FDD tools. Moreover, most of the commercial AFDD tools have not been verified in the field independently. This paper presents a comprehensive approach to bringing HVAC AFDD tools into the mainstream. The approach involves demonstrating ten commercially available tools at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying market barriers, and assisting utility companies in developing incentive programs. This paper presents selection of AFDD tools, ite identification, and field testing and evaluation method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Equivalent Battery Model Representations for Thermostatically Controlled Loads in Commercial Buildings

Models for thermostatically controlled loads in commercial buildings often include many parameters and variables compared to residential buildings. As such, it is beneficial to use reduced-order models to represent these resources. A classic example of such a model is the Virtual Battery or Equivalent Battery Model (EBM). In this paper, the typical EBM is extended to higher-order commercial Heating, Ventilation, and Air-conditioning (HVAC) models and adapted for electric water heaters. Finally, we compare the performance of EBMs with detailed thermal models using three classic optimization problems - energy maximization, energy minimization, and power reference tracking. Our results show that the EBM-constrained and detailed thermal model-constrained problems produce similar outcomes in terms of temperature, power, and total energy consumption.

commercial buildings↗

A Robust Hierarchical Dispatch Scheme for Active Distribution Networks Considering Home Thermal Flexibility

Distribution networks are changing from passive absorbers of electric energy to active distribution networks (ADNs) capable of operating and participating in electricity markets. In the context of residential microgrids, which is a type of ADNs, aggregated home heating, ventilation and air-conditioning (HVAC) loads present a key opportunity to drive operational and economic objectives, facilitate high renewable energy penetration, and enhance both system resiliency and flexibility. A robust, hierarchical dispatch scheme is developed and presented in this paper, which connects an upper level multi-phase distribution optimal power flow (DOPF) to a lower level model predictive control (MPC)-based HVAC fleet controller. The approach is tested and verified on a modified IEEE 13 bus system in an intraday market application. The results demonstrate that the proposed hierarchical dispatch scheme is able to drive both economic and operational objectives for the ADN operator.

Rooks, Cody D.↗

Development and Calibration of an Online Energy Model for AHU Fan

The model development is necessary for the study of the energy consumption of Heating, Ventilation, and Air Conditioning (HVAC) systems. To predict the HVAC energy consumption accurately, one needs to model the individual HVAC components either from the measured data or based on the knowledge of the underlying physical phenomenon. Online model characterization is critical for improving the performance of real-time model-based fault detection and diagnosis (FDD) strategies. For HVAC control, models can be used to optimize the supervisory and local feedback control strategies to improve the energy consumption efficiency, or for providing ancillary services to the grid. It has been reported that, fans in HVAC systems of commercial buildings alone can provide substantial frequency regulation service, with little change in the indoor environment. In this paper, a real-time data-driven Air Handling Unit (AHU) fan model was developed based on recursive multi regression model. A generic nonlinear polynomial model has been studied to cover scenarios with different combinations of measurement variables, variable orders as well as different training and prediction horizons. Typical measurements including static pressure, mass flow rate, and damper positions are utilized as inputs to model the power consumption of the fan. The developed models have been validated both with simulation data from EnergyPlus-Dymola co-simulation model and with field measurement data for small to medium commercial buildings. The validation results show that the online model proposed can provide an effective prediction of the AHU fan power consumption.

Dong, Jin↗