Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Vibrational response and temperature of shock-compressed Pt: In situ extended x-ray absorption fine structure measurements to 325 GPa

Single pulse (~100 ps duration) extended x-ray absorption fine structure (EXAFS) measurements were obtained in laser shocked Pt to examine atomic vibrational properties and to determine temperatures for shock pressures from 72-325 GPa. Pt x-ray absorption spectra were recorded while a planar shock wave was propagating through the Pt sample. The absorption spectrum corresponding to the shocked Pt was obtained by subtracting the ambient Pt contribution from the measured absorption spectrum. Fits to the shocked state EXAFS data provided Pt lattice parameters consistent with the known Pt Hugoniot and the mean squared relative displacements (MSRDs) for nearest neighbor Pt atoms. Pt temperatures in the shocked state, estimated from the MSRDs using the correlated Debye model and correlated Einstein models, were consistent with both the Hugoniot temperatures calculated by integration along the Hugoniot and with the Hugoniot temperatures from published first-principles calculations. However, the agreement between the Hugoniot temperatures from EXAFS measurements and the calculated Hugoniot temperatures is not as good above 200 GPa, likely due to anharmonic effects. Furthermore, the present results demonstrate that single-pulse synchrotron EXAFS measurements in laser-shocked solids are useful for quantitative temperature determination and for examination of vibrational properties, including anharmonicity, at extreme pressure-temperature conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Distance redshift from an optical metric that includes absorption

We show that it is possible to equate the intensity reduction of a light wave caused by weak absorption with a geometrical reduction in intensity caused by a 'transverse' conformal transformation of the spacetime metric in which the wave travels. We are consequently able to modify Gordon's optical metric to account for electromagnetic properties of ponderable material whose properties include both refraction and absorption. Unlike refraction alone, however, including absorption requires a modification of the optical metric that depends on the eikonal of the wave itself. We derive the distance-redshift relation from the modified optical metric for Friedman-Lemaitre-Robertson-Walker spacetimes whose cosmic fluid has associated refraction and absorption coefficients. We then fit the current supernovae data and provide an alternate explanation (other than dark energy) of the apparent acceleration of the Universe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Redshifted intergalactic {sup 3}He{sup +} 8.7 GHz hyperfine absorption

Motivated by recent interest in redshifted 21 cm emission of intergalactic hydrogen, we investigate the 8.7 GHz {sup 2}S{sub 1/2} F=0-1 hyperfine transition of {sup 3}He{sup +}. While the primordial abundance of {sup 3}He relative to hydrogen is 10{sup -5}, the hyperfine spontaneous decay rate is 680 times larger. Furthermore, the antenna temperature is much lower at the frequencies relevant for the {sup 3}He{sup +} transition compared to that of z>6 21 cm emission. We find that the spin temperature of this 8.7 GHz line in the intergalactic medium is approximately the cosmic microwave background temperature, such that this transition is best observed in absorption against high-redshift, radio-bright quasars. We show that intergalactic 8.7 GHz absorption is a promising, unsaturated observable of the ionization history of intergalactic helium (for which He II{yields}He III reionization is believed to complete at z{approx}3) and of the primordial {sup 3}He abundance. Instruments must reach {approx}1 {mu}Jy RMS noise in bands of 1 MHz on a 1 Jy source to directly resolve this absorption. However, in combination with H i Ly{alpha} forest measurements, an instrument can statistically detect this absorption from z>3 with 30 {mu}Jy RMS noise in 0.1 MHz spectral bands over 100 MHz, which may be within the reach of present instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Inverse Bremsstrahlung Absorption

Inverse bremsstrahlung absorption was measured based on transmission through a finite-length plasma that was thoroughly characterized using spatially resolved Thomson scattering. Expected absorption was then calculated using the diagnosed plasma conditions while varying the absorption model components. To match data, it is necessary to account for: (1) the Langdon effect; (2) laser-frequency (rather than plasma-frequency) dependence in the Coulomb logarithm, as is typical of bremsstrahlung theories but not transport theories; and (3) a correction due to ion screening. Radiation-hydrodynamic simulations of inertial confinement fusion implosions have to date used a Coulomb logarithm from the transport literature and no screening correction. Here, we anticipate that updating the model for collisional absorption will substantially revise our understanding of laser-target coupling for such implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

TU-A-9A-07: X-Ray Acoustic Computed Tomography (XACT): 100% Sensitivity to X-Ray Absorption

Purpose: To assess whether X-ray acoustic computed tomography (XACT) is more sensitive to X-ray absorption than that of the conventional X-ray imaging. Methods: First, a theoretical model was built to analyze the X-ray absorption sensitivity of XACT imaging and conventional X-ray imaging. Second, an XACT imaging system was developed to evaluate the X-ray induced acoustic signal generation as well as the sensitivity improvement over transmission x-ray imaging. Ultra-short x-ray pulses (60-nanosecond) were generated from an X-ray source operated at the energy of 150 kVp with a 10-Hz repetition rate. The X-ray pulse was synchronized with the acoustic detection via a x-ray scintillation triggering to acquire the X-ray induced acoustic signal. Results: Theoretical analysis shows that X-ray induced acoustic signal is sensitive only to the X-ray absorption, while completely insensitive to out the X-ray scattering and fluorescence. XACT has reduced background and increased contrast-to-noise ratio, and therefore has increased sensitivity compared to transmission x-ray imaging. For a 50-μm size, gadolinium insertion in tissue exposed to 40 keV X-rays; the sensitivity of XACT imaging is about 28.9 times higher than that of conventional X-ray imaging. Conclusion: X-ray acoustic computer tomography (XACT) as a new imaging modality combines X-ray absorption contrast and high ultrasonic resolution in a single modality. It is feasible to improve the imaging sensitivity with XACT imaging compared with conventional X-ray imaging. Taking advantage of the high ultrasonic resolution, it is possible to perform 3-D imaging with a single x-ray pulse with arrays of transducers without any mechanical motion of the imaging system. This single-shot capability offers the potential of reducing radiation dose by a factor of 1000, and imaging 100 times faster when compared to the conventional X-ray CT, and thus revolutionizing x-ray imaging applications in medicine and biology. The authors gratefully acknowledge the Department of Defense Prostate Cancer Research Programs W81XWH-13-1-0481 (LX), the National Institutes of Health 1R01 CA133474 and 1R21 A153587, and SRFDP (20124407120012) for funding.

60 APPLIED LIFE SCIENCES↗

CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D{sub L}(0) and its rise-to-the-equilibrium curve H(L) = D{sub L}(0)/D{sub eq} from computed tomography (CT) scanning, where D{sub eq} is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm{sup 3} thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E{sub in}/E or E{sub out}/E) on the phantom central and peripheral axes, where E = LD{sub eq} was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose ratios changed with beam aperture and phantom axis but were insensitive to tube voltage. H(L) was insensitive to tube voltage and CT scanner model. As phantom diameter increased from 6 to 55 cm, E{sub in}/E generally decreased but asymptotically approached constant levels on the peripheral axes of large phantoms. The curve of E{sub in}/E versus scan length was almost identical to that of H(L). Similarly, E{sub out}/E increased with scan length and asymptotically approached the equilibrium for large scan lengths. E{sub out}/D{sub eq} was much less than the equilibrium length L{sub eq} where H(L) = 0.98, even with scan lengths much larger than L{sub eq}. Conclusions: The polyethylene phantom designed by ICRU Report No. 87 Committee and AAPM Task Group 200 is adequately long for assessing the midpoint dose and its equilibration in CT scanning. The short-to-long phantom dose ratios and the H(L) data provided in this paper allow easy evaluations of the midpoint dose, longitudinal dose distribution, and energy absorption in polyethylene phantoms. The results of dose equilibration and energy absorption presented herein may be insightful for the clinical CT scans with various subject sizes and scan lengths.

07 ISOTOPE AND RADIATION SOURCES↗

Dependence of the Two-Photon Absorption Coefficient of Steel on the Pulse Duration During Its Ablation by Femto- and Picosecond Laser Pulses

The dependences of the depth of single-pulse ablation of the steel surface on the energy density of ultrashort laser pulses (0.3–12 ps) with a wavelength of 515 nm have the form different from the usual logarithmic one for linear absorption of radiation. Since the density of states of free conduction electrons in the s band is low, and the d band of strongly bound electrons with a high density of states is located around the Fermi level, these dependences have been approximated within the two-photon absorption model. The two-photon absorption coefficient increases almost linearly with the duration of laser pulses, which indicates the saturation of absorption and allows estimating the corresponding parameters of the electronic subsystem. © 2019, Pleiades Publishing, Inc.

60 APPLIED LIFE SCIENCES↗

The Effect of an Antirelaxation Coating on Absorption in the D{sub 2} Lines of Alkali Metals

The specific features of absorption in a cell with an antirelaxation coating related to optical pumping and a finite rate of laser-frequency scanning are studied. The internal state of an atom in such cells is likely to remain unaltered after a collision with a wall. This results in optical pumping of an atomic ensemble over all velocities and the entire cell volume. Both the frequency corresponding to the maximum absorption in the D{sub 2} line of {sup 133}Cs and the absorption maximum itself depend on the sign of laser-frequency scanning. A theoretical model attributing the power dependence of asymmetry of the absorption contour of the {sup 133}Cs D{sub 2} line to the presence of cyclic transition levels in the system is presented.

74 ATOMIC AND MOLECULAR PHYSICS↗

Band intensities in the circular dichroism and absorption spectra and the states of d ions in absorbing media: I. Octahedrally coordinated positions of d ions

The factors affecting the band intensity in circular dichroism (CD) and absorption spectra (selection rules, point group of structural position, and the electron density of the ground state of octahedrally coordinated d ion in absorbing medium) are considered. The intensities of CD and absorption bands are calculated and compared with the experimental data. It is shown that the differences in the spatial inversion of the electric- and magnetic-dipole moment transformations lead to a more rigorous validity of the symmetry selection rules and increase the resolution of peaks and transparency window of medium absorption in CD spectra (in contrast to absorption ones). Some criteria for estimating the valence and structural states of d ions are formulated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-photon absorption of high-power picosecond pulses in PbWO{sub 4}, ZnWO{sub 4}, PbMoO{sub 4}, and CaMoO{sub 4} crystals

The nonlinear process of two-photon interband absorption is studied in tungstate and molybdate oxide crystals excited by a sequence of high-power picosecond pulses with a wavelength of 523.5 nm. The transmission of the crystals is measured for the excitation pulse intensity up to 100 GW/cm{sup 2}. The pulse intensity in the crystals initially transparent at a wavelength of 523.5 nm is strongly limited due to two-photon absorption (TPA), and the reciprocal transmission in PbWO{sub 4} and ZnWO{sub 4} crystals reaches 50-60. In all crystals, TPA induces long-lived one-photon absorption, which affects the nonlinear process dynamics and leads to a hysteresis in the dependence of the transmission on the laser excitation intensity. Absorption dichroism manifests itself in a significant difference in the transmission intensities when the principal orthogonal optical axes of the crystals are excited. The TPA coefficients are determined during the excitation of two optical axes of the crystals. TPA coefficients {beta} for the crystals vary over a wide range, namely, from {beta} = 2.4 cm/GW for PbMoO{sub 4} to {beta} = 0.14 cm/GW for CaMoO{sub 4}, and the values of {beta} can differ almost threefold when different optical axes of a crystal are excited. Good agreement is achieved between the measured intensities limited by TPA and the estimates calculated from the measured nonlinear coefficients. Stimulated Raman scattering (SRS) upon excitation at a wavelength of 523.5 nm is only detected in two of the four crystals under study. The experimental results make it possible to explain the suppression of SRS by its competition with TPA, and the measured nonlinear coefficients are used to estimate this suppression.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-frequency absorption of the dynamic mixed state in the surface superconductivity region

We analyze the absorption of a high-frequency electromagnetic field in the type II superconductor Pb{sub 0.8}In{sub 0.2} in magnetic fields H{sub c2} < H < H{sub c3}. The absorption component proportional to the rate of variation of the external magnetic field is detected. We assume that this absorption component is associated with the dynamic mixed state of the superconducting shell containing 2D magnetic flux vortices (Kulik vortices). The motion of these vortices under the action of the critical current ensures the required difference between the external and internal magnetic inductions of the superconducting shell upon a change in the external magnetic field. This model correctly describes the observed behavior of absorption of rf electromagnetic radiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absorption of Ultrashort Laser Pulses by Diatomic Molecules

The absorption of ultrashort laser pulses by diatomic CO and HF molecules is studied theoretically. The probability of absorption in the total pulse action time and its dependence on the pulse duration and carrier frequency are calculated. In contrast to atomic systems, where the finite pulse duration effects are noticeable on time scales of the order of femtoseconds, these effects in molecular structures manifest themselves on time scales of the order of picoseconds. In this case, the vibrational–rotational structure of molecular transitions plays a significant role. The results of our calculations of the vibrational–rotational spectra for the absorption of ultrashort laser pulses by diatomic CO and HF molecules are presented. The transition from the nonlinear dependence of the absorption probability for short pulse durations to the standard dependence at long pulse durations corresponding to the transition probabilities per unit time is investigated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Three-dimensional simulations of anomalous absorption of laser radiation by plasma with supercritical density

A three-dimensional (3D) model of the interaction of laser radiation with plasma in the framework of Maxwell-Vlasov equations has been used to calculate the anomalous optical absorption in plasma of supercritical density. The results of calculations confirmed the development of anomalous absorption that was previously revealed by 2D models, which were insufficient for comparison to the experiment. Calculations were performed for a system containing about 10{sup 6} macroparticles that allowed the absorption coefficient and other characteristics of anomalous absorption in plasma with an inhomogeneous surface to be determined as functions of various parameters of the incident radiation and plasma target. Results are analyzed and estimations are obtained for the contributions of ionization processes and pair collisions of electrons, which show that these factors were quite reasonably ignored in the model. All quantitative results are obtained for the third harmonic of neodymium laser ({lambda} = 0.351 {mu}m) at a tenfold excess of the substance density over a critical value for this radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonance Absorption of Electromagnetic Radiation in a Phosphorene Single Layer

The absorption coefficient of the electromagnetic radiation in a phosphorene single layer placed in a magnetic field is found. A degenerate and nondegenerate electron gas is considered. The resonant dependences of the absorptance on the radiation frequency and applied magnetic field are found. Taking into account electron scattering at an ionized impurity leads to oscillation dependences of the absorption coefficient on the radiation frequency and external magnetic field. The resonance character of the absorption curve is shown. The conditions of resonances and position of resonance peaks are found.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate temperature model for absorptance determination of optical components with laser calorimetry

In the international standard (International Organization for Standardization 11551) for measuring the absorptance of optical components (i.e., laser calorimetry), the absorptance is obtained by fitting the temporal behavior of laser irradiation-induced temperature rise to a homogeneous temperature model in which the infinite thermal conductivity of the sample is assumed. In this paper, an accurate temperature model, in which both the finite thermal conductivity and size of the sample are taken into account, is developed to fit the experimental temperature data for a more precise determination of the absorptance. The difference and repeatability of the results fitted with the two theoretical models for the same experimental data are compared. The optimum detection position when the homogeneous model is employed in the data-fitting procedure is also analyzed with the accurate temperature model. The results show that the optimum detection location optimized for a wide thermal conductivity range of 0.2-50W/m{center_dot}K moves toward the center of the sample as the sample thickness increases and deviates from the center as the radius and irradiation time increase. However, if the detection position is optimized for an individual sample with known sample size and thermal conductivity by applying the accurate temperature model, the influence of the finite thermal conductivity and sample size on the absorptance determination can be fully compensated for by fitting the temperature data recorded at the optimum detection position to the homogeneous temperature model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement and modeling of infrared nonlinear absorption coefficients and laser-induced damage thresholds in Ge and GaSb

Using a simultaneous fitting technique to extract nonlinear absorption coefficients from data at two pulse widths, we measure two-photon and free-carrier absorption coefficients for Ge and GaSb at 2.05 and 2.5 {mu}m for the first time, to our knowledge. Results agreed well with published theory. Single-shot damage thresholds were also measured at 2.5 {mu}m and agreed well with modeled thresholds using experimentally determined parameters including nonlinear absorption coefficients and temperature dependent linear absorption. The damage threshold for a single-layer Al{sub 2}O{sub 3} anti-reflective coating on Ge was 55% or 35% lower than the uncoated threshold for picosecond or nanosecond pulses, respectively.

36 MATERIALS SCIENCE↗

Modeling, Design, and Testing of a Novel Biphasic Solvent-Enabled Absorption System for Post-Combustion Carbon Capture

A novel absorption process enabled by a new class of biphasic solvents for post-combustion carbon capture (BiCAP) is presently being developed at the University of Illinois at Urbana-Champaign. The new biphasic solvents are water-lean solvent blends that develop dual liquid phases with the absorbed CO2 highly enriched in one of the phases. These solvents are superior in CO2 capacity and have high thermal and oxidative stability compared to MEA. The BiCAP technology features a unique process configuration of multi-stage CO2 absorption and liquid–liquid phase separation during CO2 absorption, allowing continual separation and removal of the CO2-enriched liquid phase for maintaining low solvent viscosity and a fast absorption rate. A 40 kWe-scale skid has recently been constructed at the Abbott Power Plant in Champaign, IL, to test the BiCAP solvent in continuous operation with a slipstream of real post-combustion flue gas. Along with improvements in the stripping configuration including cold feed bypass, the process is expected to achieve a minimum reboiler duty of 2,210 kJ/kg CO2 captured at a stripper operating pressure of 6 bar.

20 FOSSIL-FUELED POWER PLANTS↗