Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Intrinsic Li Distribution in Layered Transition-Metal Oxides Using Low-Dose Scanning Transmission Electron Microscopy and Spectroscopy

Understanding Li distribution in layered lithium transition-metal oxide (LiTMO) cathodes in Li-ion batteries has been a major challenge at the atomic scale and nanoscale. Li is extremely difficult to study by transmission electron microscopy (TEM) because the high-energy electrons impart significant energy and cause massive migration. Here, we directly map the intrinsic spatial distribution and bonding of Li in LiNiO 2 -layered cathode materials using low-dose and low-loss electron energy loss spectroscopy (EELS). EELS spectra of the Li–K edge are measured simultaneously with O–K and Ni–L, M 3,2 edges from layered, cation-mixed, and rock-salt phases and directly matched with atomic-resolution scanning TEM images to correlate the changes in peak intensities and positions to the stoichiometry changes with continual loss of Li and O. Changes in the Li content in the LiNiO 2 particles as a function of electron beam dose are studied by sequential Li spectroscopic mapping. We show that the “intrinsic” Li distribution can be observed using a total dose of less than ~1.5 × 10 8 e – nm –2 at an accelerating voltage of 80 kV. The method of nanoscale mapping of Li distribution introduced in this study is applicable to high-Ni LiTMO cathode materials (>89% of Ni) as well as LiNiO 2 . Further study on the extra peaks of the Li–K edge reveals that the peak at ~59 eV is from the Li ions intercalated in between NiO 2 layers barely interacting with each other with less Li K shell electrons pulled to the L shell electrons in NiO 2 . Furthermore, the results shown here provide improved low-loss TEM characterization approaches that can be used to understand the intrinsic fundamental behaviors in Li-ion batteries.

25 ENERGY STORAGE↗

High accuracy barrier heights, enthalpies, and rate coefficients for chemical reactions

Abstract Quantitative chemical reaction data, including activation energies and reaction rates, are crucial for developing detailed kinetic mechanisms and accurately predicting reaction outcomes. However, such data are often difficult to find, and high-quality datasets are especially rare. Here, we use CCSD(T)-F12a/cc-pVDZ-F12// ω B97X-D3/def2-TZVP to obtain high-quality single point calculations for nearly 22,000 unique stable species and transition states. We report the results from these quantum chemistry calculations and extract the barrier heights and reaction enthalpies to create a kinetics dataset of nearly 12,000 gas-phase reactions. These reactions involve H, C, N, and O, contain up to seven heavy atoms, and have cleaned atom-mapped SMILES. Our higher-accuracy coupled-cluster barrier heights differ significantly (RMSE of ∼5 kcal mol −1 ) relative to those calculated at ω B97X-D3/def2-TZVP. We also report accurate transition state theory rate coefficients $${k}_{\infty }(T)$$ k ∞ ( T ) between 300 K and 2000 K and the corresponding Arrhenius parameters for a subset of rigid reactions. We believe this data will accelerate development of automated and reliable methods for quantitative reaction prediction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved scaling of temperature-accelerated dynamics using localization

While temperature-accelerated dynamics (TAD) is a powerful method for carrying out non-equilibrium simulations of systems over extended time scales, the computational cost of serial TAD increases approximately as N{sup 3} where N is the number of atoms. In addition, although a parallel TAD method based on domain decomposition [Y. Shim et al., Phys. Rev. B 76, 205439 (2007)] has been shown to provide significantly improved scaling, the dynamics in such an approach is only approximate while the size of activated events is limited by the spatial decomposition size. Accordingly, it is of interest to develop methods to improve the scaling of serial TAD. As a first step in understanding the factors which determine the scaling behavior, we first present results for the overall scaling of serial TAD and its components, which were obtained from simulations of Ag/Ag(100) growth and Ag/Ag(100) annealing, and compare with theoretical predictions. We then discuss two methods based on localization which may be used to address two of the primary “bottlenecks” to the scaling of serial TAD with system size. By implementing both of these methods, we find that for intermediate system-sizes, the scaling is improved by almost a factor of N{sup 1/2}. Some additional possible methods to improve the scaling of TAD are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct electron acceleration in multi-kilojoule, multi-picosecond laser pulses

The physics mechanism behind the acceleration of electrons to energies much higher than the laser ponderomotive potential is reported. While electrons with these energies have been observed for the last twenty years at the one percent level, it is only with the recent advent of high power lasers with extended pulse durations, large focal spots, and high intensities that significant numbers (>10%) of the so-called “superponderomotive” electrons have been observed. Evidence is provided that the dominant acceleration mechanism of superponderomotive electrons is direct acceleration by the electromagnetic (EM) wave of the laser as they co-propagate in an under-dense plasma; one-dimensional particle-in-cell simulations yield electron spectra with typically ten times the ponderomotive temperature. Direct acceleration requires tens of plasma wavelengths of under-dense plasma, as well as pulse durations of tens of plasma periods, conditions that can be found in large focal spot multi-picosecond laser pulses. It is shown that the plasma simply provides the source of accelerated electrons and a variety of methods to inject a significant population of electrons into the EM waves at relativistic energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Filamentation and focusing of electron beams due to interactions with plasma waves

Results of numerical modeling of the interaction of an electron beam propagating across relativistic plasma waves indicate that electron beam filamentation and focusing may occur under certain conditions. The model is based on solving the relativistic equation of motion in three dimensions for the individual electrons in a tenuous Gaussian beam, as they pass through a relativistic plasma wave. Several electron beam and plasma wave parameters were varied, and the results are summarized. One of the results is that the spacing of the electron beam filaments correlates with the wavelength of the plasma wave. The electron beam filaments appear as vertical slabs after the beam exits the plasma waves. The electron beam also compresses to a focus after it exits the plasma, and the focal distance depends on several parameters including the electron beam energy and phase velocity of the relativistic plasma wave. It is suggested that these focusing and filamentation phenomena may be the basis for diagnostics schemes for laser plasma interactions. The parameters used in the model were electron beam energies in the 5–50 keV range and plasma wave properties typical for the beat-wave produced by CO2 lasers, which correspond to the facilities available in our laboratory. The limitations of these results to lower energy density beam and plasma regimes and to higher energy density regimes will be discussed.

47 OTHER INSTRUMENTATION↗

Advanced data analysis in inertial confinement fusion and high energy density physics

Bayesian analysis enables flexible and rigorous definition of statistical model assumptions with well-characterized propagation of uncertainties and resulting inferences for single-shot, repeated, or even cross-platform data. This approach has a strong history of application to a variety of problems in physical sciences ranging from inference of particle mass from multi-source high-energy particle data to analysis of black-hole characteristics from gravitational wave observations. The recent adoption of Bayesian statistics for analysis and design of high-energy density physics (HEDP) and inertial confinement fusion (ICF) experiments has provided invaluable gains in expert understanding and experiment performance. In this Review, we discuss the basic theory and practical application of the Bayesian statistics framework. We highlight a variety of studies from the HEDP and ICF literature, demonstrating the power of this technique. Due to the computational complexity of multi-physics models needed to analyze HEDP and ICF experiments, Bayesian inference is often not computationally tractable. Two sections are devoted to a review of statistical approximations, efficient inference algorithms, and data-driven methods, such as deep-learning and dimensionality reduction, which play a significant role in enabling use of the Bayesian framework. We provide additional discussion of various applications of Bayesian and machine learning methods that appear to be sparse in the HEDP and ICF literature constituting possible next steps for the community. We conclude by highlighting community needs, the resolution of which will improve trust in data-driven methods that have proven critical for accelerating the design and discovery cycle in many application areas.

47 OTHER INSTRUMENTATION↗

Clustering in massive neutrino cosmologies via Eulerian Perturbation Theory

We introduce an Eulerian Perturbation Theory to study the clustering of tracers for cosmologies in the presence of massive neutrinos. Our approach is based on mapping recently-obtained Lagrangian Perturbation Theory results to the Eulerian framework. We add Effective Field Theory counterterms, IR-resummations and a biasing scheme to compute the one-loop redshift-space power spectrum. To assess our predictions, we compare the power spectrum multipoles against synthetic halo catalogues from the QUIJOTE simulations, finding excellent agreement on scales k ≲ 0.25 h Mpc-1. One can obtain the same fitting accuracy using higher wave-numbers, but then the theory fails to give a correct estimation of the linear bias parameter. We further discuss the implications for the tree-level bispectrum. Finally, calculating loop corrections is computationally costly, hence we derive an accurate approximation wherein we retain only the main features of the kernels, as produced by changes to the growth rate. As a result, we show how FFTLog methods can be used to further accelerate the loop computations with these reduced kernels.

79 ASTRONOMY AND ASTROPHYSICS↗

Suppressing the sample variance of DESI-like galaxy clustering with fast simulations

Ongoing and upcoming galaxy redshift surveys, such as the Dark Energy Spectroscopic Instrument (DESI) survey, will observe vast regions of sky and a wide range of redshifts. In order to model the observations and address various systematic uncertainties, N-body simulations are routinely adopted, however, the number of large simulations with sufficiently high mass resolution is usually limited by available computing time. Therefore, achieving a simulation volume with the effective statistical errors significantly smaller than those of the observations becomes prohibitively expensive. In this study, we apply the Convergence Acceleration by Regression and Pooling (CARPool) method to mitigate the sample variance of the DESI-like galaxy clustering in the AbacusSummit simulations, with the assistance of the quasi-N-body simulations FastPM. Based on the halo occupation distribution (HOD) models, we construct different FastPM galaxy catalogs, including the luminous red galaxies (LRGs), emission line galaxies (ELGs), and quasars, with their number densities and two-point clustering statistics well matched to those of AbacusSummit. We also employ the same initial conditions between AbacusSummit and FastPM to achieve high cross-correlation, as it is useful in effectively suppressing the variance. Our method of reducing noise in clustering is equivalent to performing a simulation with volume larger by a factor of 5 and 4 for LRGs and ELGs, respectively. We also mitigate the standard deviation of the LRG bispectrum with the triangular configurations k 2 = 2k 1 = 0.2 h Mpc -1 by a factor of 1.6. With smaller sample variance on galaxy clustering, we are able to constrain the baryon acoustic oscillations (BAO) scale parameters to higher precision. The CARPool method will be beneficial to better constrain the theoretical systematics of BAO, redshift space distortions (RSD) and primordial non-Gaussianity (NG).

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical simulation of frost formation and heat transfer on fin-and-tube heat exchangers in turbulent cross-flow

Frost formation in fin-and-tube heat exchangers in turbulent cross-flow presents significant challenges in industrial refrigeration applications, affecting heat transfer efficiency and operational reliability. The purpose of this work is to investigate frost deposition and growth on a staggered bank of a fin-and-tube freezer coil under turbulent forced convection conditions. The focus here is on investigating conditions that closely replicate real-world scenarios in large walk-in industrial freezers. Using a direct numerical simulation approach, we examine the flow dynamics and thermal behaviour in the presence of frost, considering turbulent regimes characterized by a Reynolds number in the range 1050 ≤ R e D , avg ≤ 4800 , with the characteristic length being the outer diameter of the tube and the velocity being the bulk fluid velocity between the plates (fins). Computational fluid dynamics simulations are employed to resolve the interactions between turbulent airflow and the frost layer. Our approach incorporates a modified immersed boundary method and a slow-time acceleration technique to address the complex dynamic interface between the continuously evolving frost layer and the flowing air stream. Our findings indicate that frost forms more on the sides of the finned surfaces (plates) and less on the tubes themselves. This article is part of the theme issue ‘Heat and mass transfer in frost and ice’.

Science & Technology - Other Topics↗

Testing hadronic interactions at ultrahigh energies with air showers measured by the Pierre Auger Observatory

Ultrahigh energy cosmic ray air showers probe particle physics at energies beyond the reach of accelerators. Here we introduce a new method to test hadronic interaction models without relying on the absolute energy calibration, and apply it to events with primary energy 6–16 EeV (E CM = 110–170 TeV), whose longitudinal development and lateral distribution were simultaneously measured by the Pierre Auger Observatory. As a result, the average hadronic shower is 1.33±0.16 (1.61±0.21) times larger than predicted using the leading LHC-tuned models EPOS-LHC (QGSJetII-04), with a corresponding excess of muons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Faster-Than-Real-Time Framework for Reliability-Oriented Simulation of PV Inverters

Physics-of-Failure (PoF) based reliability assessment for photovoltaic (PV) inverters requires long-duration electrical and electrothermal stress histories, yet generating such stress histories with high-fidelity switching models over year long mission profiles is computationally prohibitive. Conventional methods either sacrifice modeling fidelity for speed or require runtimes that are impractical for design iteration and uncertainty studies. To address this bottleneck, this paper presents a High-Performance Computing (HPC) based simulation frame work for faster-than-real-time reliability-oriented simulation. The proposed framework integrates the Average-to-Switching (A2S) method with parallel computing techniques to accelerate switching-level waveform reconstruction. We further introduce optimization strategies, including cluster merging and sensitivity based mission profile screening, to reduce the computational burden. Evaluated using real-world mission profile inputs and a MATLAB/Simulink switching-model reference, the framework reduces the simulation time for a one-year mission from an intractable multi-year duration to approximately 7.3 minutes while maintaining low waveform error. This acceleration provides a practical reliability-oriented simulation engine that can be coupled with component-specific aging models for subsequent PV inverter PoF assessment.

High-performance Computing↗

SU-F-J-36: Comparison of Ball Bearing and Iso-Cube Phantoms for KV-MV Iso-Center Coincidence Check

Purpose: To compare two different quality assurance tools for kV-MV isocenter coincidence check. Methods: Ball-Bearing device (BBD) (Elekta) provided along with a CBCT equipped LINAC and isocenter cube phantom (CP) (a commercial product of Modus Medical Devices) are utilized to check the coincidence between the MV and kV beam isocenters. The microstepping meter of the BBD allows precision adjustment to better than 0.01mm in three directions. The BBD is aligned to the MV-isocenter with the lasers and followed by taking MV-images of at two collimator angles at each cardinal gantry, then its position adjusted. This process takes in iterative steps until 0.25mm tolerance is achieved. Four planar kV-images are taken at cardinal angles and deviations of BBD position from kVisocenter are evaluated. CP is positioned on the couch with the lasers at known offset from the isocenter. CBCT is utilized to set the cube to its kV isocenter with the precision of linac’s couch (1mm). MV-images are taken at various gantry, collimator, and couch angles and evaluated with the CP manufacturer provided QA software to determine coincidence of the 6mm steel ball at cube center with MV-isocenter. Three sets of measurements, one after another, were performed on the same day for each phantom on the same linac. Results: Assuming little variation between kV and MV isocenters in a short time, BBD measurements are more reproducible than CP. With comparable conditions both methods agree within 0.5 mm in each direction, while for BBD average standard deviation was 0.07mm and for iso-cube 0.3mm. Conclusion: Since BBD is more reliable and its results are more reproducible, it should be used during the monthly QA. Since CP is a more efficient device, it should be used for daily QA. A comparison study between the two devices should be periodically performed.

60 APPLIED LIFE SCIENCES↗

SU-F-T-72: Experimental Determination of the Positionuncertainties for ROOS Ionization Chambers in Clinical Electron Beams

Purpose: National and international dosimetry protocols assume a position accuracy for ionization chambers of less than 0.2mm. To follow this precept the manufacturer PTW-Freiburg introduced a positioning assistance system (TRUFIX) for their particular ion chambers. Aim of this study is an experimental investigation of the positioning uncertainties for ROOS-type ionization chambers. Methods: For all measurements a linear accelerator Elekta Synergie was used. The experiments were performed in a water-phantom. To collimate the electron beam a 10×10cm{sup 2} applicator was installed. All measured depth dose curves were normalized to their maximum. In all cases the TRUFIX system was applied for chamber positioning. For the first measurement series, to determine the positioning reproducibility of a ROOS chamber, one person placed the chamber three times in a 6 MeV electron beam. The mean value of this three measurements was the reference for further six random persons who repeated this procedure. The results were compared for different depths (R{sub 50}, z{sub ref} and R{sub p}). To investigate the impact of different individual chambers of the same type 10 different ROOS chambers were placed by the same person in a 6, 12 and 18MeV electron beam and the measured reference depths z{sub ref} were compared. Results: The absolute positioning reproducibility is less than 0.1mm for the same person. The positioning uncertainties are increasing up to +/−0.3mm if different persons perform the chamber’s positioning within the water phantom. The comparison of the 10 different ROOS chambers resulted in reference depths z{sub ref} with deviations in the range of +/−0.45mm for all energies. Conclusion: The position accuracy of 0.2mm can be fulfilled with the TRUFIX system. The comparison of the 10 different ROOS ionization chambers showed noticeable deviations in the determined reference depth. The impact of a positioning uncertainty of about 0.3–0.4mm on the total perturbation correction will be considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-415: Differences in Lung Sparing in Deep Inspiration Breath-Hold and Free Breathing Breast Plans Calculated in Pinnacle and Monaco

Purpose: Deep inspiration breath-hold (DIBH) is used for left-sided breast radiotherapy to spare the heart and lung. The magnitude of sparing has been shown to be significant. Monte Carlo, furthermore, has the potential to calculate most accurately the dose in the heterogeneous lung medium at the interface with the lung wall. The lung dose was investigated in Monaco to determine the level of sparing relative to that calculated in Pinnacle{sup 3}. Methods: Five patients undergoing DIBH radiotherapy on an Elekta Versa HD linear accelerator in conjunction with the Catalyst C-RAD surface imaging system were planned using Phillips Pinnacle{sup 3}. Free breathing plans were also created to clinically assure a benefit. Both plans were re-calculated in Monaco to determine if there were any significant differences. The mean heart dose, mean left lung, and mean total lung dose were compared in addition to the V20 for left and both lungs. Dose was calculated as dose to medium as well as dose to water with a statistical precision of 0.7%. Results: Mean lung dose was significantly different (p < 0.003) between the two calculations for both DIBH (11.6% higher in Monaco) and free breathing (14.2% higher in Monaco). V20 was also higher in Monaco (p < 0.05) for DIBH (5.7% higher) and free breathing (4.9% higher). The mean heart dose was not significantly different between the dose calculations for either DIBH or free breathing. Results were no more than 0.1% different when calculated as dose to water. Conclusion: The use of Monte Carlo can provide insight on the lung dose for both free breathing and DIBH techniques for whole breast irradiation. While the sparing (dose reductions with DIBH as compared to free breathing) is equivalent for either planning system, the lung doses themselves are higher when calculated with Monaco.

60 APPLIED LIFE SCIENCES↗

SU-F-T-463: Light-Field Based Dynalog Verification

Purpose: To independently verify leaf positions in so-called dynalog files for a Varian iX linac with a Millennium 120 MLC. This verification provides a measure of confidence that the files can be used directly as part of a more extensive intensity modulated radiation therapy / volumetric modulated arc therapy QA program. Methods: Initial testing used white paper placed at the collimator plane and a standard hand-held digital camera to image the light and shadow of a static MLC field through the paper. Known markings on the paper allow for image calibration. Noise reduction was attempted with removal of ‘inherent noise’ from an open-field light image through the paper, but the method was found to be inconsequential. This is likely because the environment could not be controlled to the precision required for the sort of reproducible characterization of the quantum noise needed in order to meaningfully characterize and account for it. A multi-scale iterative edge detection algorithm was used for localizing the leaf ends. These were compared with the planned locations from the treatment console. Results: With a very basic setup, the image of the central bank A leaves 15–45, which are arguably the most important for beam modulation, differed from the planned location by [0.38±0.28] mm. Similarly, for bank B leaves 15–45 had a difference of [0.42±0.28] mm Conclusion: It should be possible to determine leaf position accurately with not much more than a modern hand-held camera and some software. This means we can have a periodic and independent verification of the dynalog file information. This is indicated by the precision already achieved using a basic setup and analysis methodology. Currently, work is being done to reduce imaging and setup errors, which will bring the leaf position error down further, and allow meaningful analysis over the full range of leaves.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-00: AAPM-AMPR (Russia)-SEFM (Spain) Joint Course On Challenges and Advantages of Small Field Radiation Treatment Techniques

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-01: Introduction

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-02: Small Field Radiation Therapy: Physics and Recent Recommendations From IAEA and ICRU

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗