Preliminary Assessment of Elemental Analysis of X-Ray Fluorescence with Genetic Algorithm

X-ray fluorescence (XRF) spectroscopy is a promising approach to elemental analysis of forensic samples. Elements in the mixture can be identified from the XRF data because chemical elements are associated with unique spectra. This report consists of preliminary assessment of automated identification of unknown mixtures of elements from XRF spectra using a genetic algorithm (GA). The XRF spectra are measured at the Advanced Photon Source (APS) at the liquid-liquid interface during solvent extraction process. Possible advantages of using GA for identifying elements at the interface from XRF data are discussed, and a path for implementation of GA is outlined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Project 18-15263 X-ray Studies of Interfacial Molecular Complexes in ALSEP Back-Extraction (Research Performance Final Report)

The objective of the project was to use synchrotron X-rays to measure the molecular-scale organization of extractants, complexants, buffers, and metal ions at the organic-aqueous (liquid-liquid) interface during solvent back-extraction under conditions relevant to ALSEP (Actinide-Lanthanide Separation Process). The capability of X-ray fluorescence near total reflection (XFNTR) was extended to explore the distribution of Eu(III) between the liquid-liquid interface and bulk organic and aqueous phases which contained extractants HDEHP (bis(2-ethylhexyl) phosphoric acid) and HEHEHP (2-ethylhexyl phosphonic acid mono-2-ethylhexyl ester), the complexant DTPA (diethylene triamine pentaacetic acid), and citric and nitric acids. Although an Am-compatible sample cell was developed, extending x-ray measurements of flat liquid-liquid interfaces to the actinide Am(III) did not prove to be possible within constraints imposed by the Advanced Photon Source. However, preliminary measurements with a drop cell may eventually provide a path forward to investigate Am(III) at a liquid interface. It was also demonstrated that competitive binding that occurs during back-extraction of lanthanide ions to either a phosphoric acid extractant (DHDP, di-hexadecyl phosphate) at the liquid interface or to complexant DTPA in the bulk aqueous phase could be reversibly tuned by X-ray exposure. Separately, X-ray measurements from the liquid-vapor interface explored the role of the aqueous solubility of HDEHP and HEHEHP and their interactions with a range of lanthanides and transition metal ions. Finally, the capability of X-ray absorption spectroscopy (EXAFS) was extended to probe metal ion coordination in lanthanide ion-extractant complexes at the liquid-vapor interface. Complementary to the specific interfacial systems studied during this project, the development of x-ray techniques expands our ability to understand ion ordering at liquid interfaces.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Probing Fundamental Mechanisms of Plastic Deformation with High Energy X-rays (Final Progress Report)

Overall, substantial progress was made on developing BCDI techniques in the direction of imaging defects in multi-crystal samples. Section 2.1 describes a new method to reconstruct the 3D atomic displacement field within a grain from multiple coherently resolved diffraction peaks. The key development is the ability to recover a best fit to the grain shape at the same time as the internal displacement (strain) variation with no prior knowledge of the microstructure. This is complemented by the development of a method, Sec. 2.2, to separate out sets of Laue reflections that belong to a single grain (and thus be able to index its orientation) in the commonly encountered situation in which the beam illuminates several grains in a given location. This is essential for enabling collection of coherent diffraction data (at APS 34-ID-C) from neighboring grains. All experiments depend on the quality of samples used. Although good progress has been made with thin film samples, we are working with a broader range of geometries. A new sample design uses a high-Z metal (e.g., Pt) deposited in a sub-micron trench in a low-Z metal (e.g., Al) so that the grain size is prevented from exceeding the current limit for BCDI. We also report in section 3.1 on successfully applying NF-HEDM to a fine-grain Mg sample that would normally be considered out of scope for the method. This represents progress towards being able to map out polycrystalline samples in 3D before performing BCDI on individual grains. We further report in section 3.2 on preliminary NF-HEDM characterization of a sample of UO2 that has sub-micron grains; the data imply the capability of mapping fine-grain polycrystals at 1-ID-E, again for the purposes of BCDI in the bulk. Lastly, our plan is to load grains in polycrystalline samples by inducing thermal stress. We also report the experimental measurements of the Ti- 6Al-4V alloy obtained at the European Synchrotron Radiation Facility (ESRF), which had been indexed and mapped via HEDM at APS in section 9. As discussed below, however, technique development pre-occupied the team throughout the project which meant that we did not make any significant progress towards answering the original hypotheses as stated in the proposal. In summary, we assert that we have made good progress in methods and samples and future work taking advantage of this progress is likely to obtain and analyze BCDI data from multiple adjacent grains in 3D polycrystals. Obtaining such data depends on re-gaining access to the Advanced Photon Source, which is anticipated in late summer or the Fall. In all cases, work has involved close collaboration with faculty, staff, postdocs and students from Brigham Young University (BYU), the Los Alamos National Laboratory and APS beamlines 1-ID and 34-ID.

36 MATERIALS SCIENCE↗

Progress in Genetic Algorithm Fitting of X-Ray Fluorescence Data for Absorption Spectroscopy of Liquid Surfaces

X-ray fluorescence (XRF) spectroscopy of liquid surfaces is a promising approach to elemental analysis of forensic samples. Elements in the mixture can be identified from the XRF data because chemical elements are associated with unique spectra. This report describes progress in the development of automated identification of unknown mixtures of elements from XRF spectra using a genetic algorithm (GA). The XRF spectra are measured at the Advanced Photon Source (APS) at the liquid-liquid interface during solvent extraction process. The usage of the GA is demonstrated and future implementation for related problems are then discussed.

47 OTHER INSTRUMENTATION↗

Identifying Critical Mineral Binding Mechanisms and Distribution in Acid Mine Drainage Treatment Solids to Inform Targeted Recovery Methods

In this study, micro-X-ray Fluorescence and micro/bulk X-ray Adsorption Near Edge Spectroscopy were collected at Stanford Synchrotron Radiation Lightsource and the Advanced Photon Source to: (1) gain a detailed characterization of critical minerals in Fe/Mn (hydr)oxide host phases; and (2) investigate the Co/Ni coordination and redox speciation associated with Fe/Mn (hydr)oxides phases in AMD solids with diverse composition (e.g., Al-rich, Mn-rich, Al/Mn/Fe-rich). Preliminary results show co-location of Co/Ni within Mn-rich hotspots, while Fe-rich hotspots were associated with heavy REEs. In Al-rich solids, Mn speciation was mostly comprised of Mn+3/+4 oxides, while the Mn-rich solids contain predominately Mn+4. These results suggest the AMD matrix plays an important role in how Co/Ni are coordinated, which aids in evaluating the efficacy to utilize AMD solids as a resource, and informs other novel sorbent and recovery technologies.

Hoffman, Colleen↗

FY24 accomplishments in preparation for startup of Activated Materials Laboratory (AML)

The Activated Materials Laboratory (AML) will be a new radiological facility at the Advanced Photon Source (APS) in Argonne National Laboratory (ANL), adjacent to the high-energy x-ray microscopy (HEXM) beamline in the long beamline building (LBB) constructed under the APS-upgrade (APS-U) project. The AML is a centralized facility to facilitate the safe conduct of experiments on activated materials at the APS. This report provides an overview of the status of the AML as a Nuclear Science User Facilities (NSUF) partner user facility in preparation for the general user access in 2025 upon the commissioning of the APS-U beamlines. The AML's scope, functionality and components are detailed. The NSUF partner beamlines’ commissioning status in the post-APS-U era is provided, along with the AML’s operational updates and operational plan.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultra-High-Speed X-ray Tomography: Bridging the Gaps to See the Unknown

Rapid, time-varying, three-dimensional physics underpin numerous engineering challenges. Often, these physics occur within opaque environments, internal to a component, severely limiting applicable diagnostics. Development of novel diagnostics is necessary to understand and predict transient three-dimensional (3D) phenomena within opaque environments. This report highlights progress in four key areas leading to advancements in high-speed X-ray radiography and tomography. The first area is enabling MHz-rate imaging of energetics at the Advanced Photon Source at Argonne National Laboratory. The second is modeling a high-flux, rotating-anode X-ray source to understand the heat loads on the anode. The third effort was to develop a novel reconstruction algorithm that is validated by ground experimental tomography data and synthetic tomography data. The fourth is the development of a novel approach to two-color X-ray imaging.

42 ENGINEERING↗

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION↗

Development of materials resistant to metal dusting degradation.

The deposition of carbon from carbonaceous gaseous environments is prevalent in many chemical and petrochemical processes such as, hydrogen-, ammonia-, and methanol-reforming systems, syngas production systems, and iron-ore reduction plants. One of the major consequences of carbon deposition is the degradation of structural materials by a phenomenon known as ''metal dusting''. There are two major issues of importance in metal dusting. First is formation of coke and subsequent deposition of coke on metallic structural components. Second is the initiation and subsequent propagation of metal dusting degradation of the structural alloy. In the past, we reported on the mechanism for metal dusting of Fe- and Ni-base alloys. In this report, we present metal dusting data on both Fe- and Ni-base alloys after exposure in high and atmospheric pressure environments that simulate the gas chemistry in operating hydrogen reformers. We have also measured the progression of pits by measuring the depth as a function of exposure time for a variety of Fe- and Ni-base structural alloys. We have clearly established the role of transport of iron in forming a non-protective spinel phase in the initiation process and presence of carbon transfer channels in the oxide scale for the continued propagation of pits, by nano-beam X-ray analysis using the advance photon source (APS), Raman scattering, and SEM/EDX analysis. In this report, we have developed correlations between weight loss and pit progression rates and evaluated the effects of carbon activity, system pressure, and alloy chemistry, on weight loss and pit propagation. To develop pit propagation data for the alloys without incurring substantial time for the initiation of pits, especially for the Ni-base alloys that exhibit incubation times of thousands of hours, a pre-pitting method has been developed. The pre-pitted alloys exhibited pit propagation rates similar to those of materials tested without pre-pitting. We have also developed a substantial body of metal-dusting data on the performance of Fe- and Ni-base weldments. During the course of this project, we have developed new Ni-base and Cu-base alloys and tested them in simulated metal dusting environments at 1 atm and at high pressures. Results clearly showed superior performance of both classes of alloys in resisting metal dusting. We also developed an approach to mitigate metal dusting by performing an intermediate oxidation step for extending the life of alloys in which metal dusting has initiated and pits are in progression. Finally, we have analyzed several components that have failed in plants such as hydrogen plant, pilot plant reformer, and a gas boiler.

01 COAL, LIGNITE, AND PEAT↗

Countering sensor drift in x-ray micrscopy with fast and robust optimal control

In X-ray microscopy it is imperative that the relative position between the optics stage, that carries the X-ray focusing optics, and the sample stage follow a certain trajectory while either the optics or sample stage is being scanned. Main challenges in achieving this requirement include - open loop drift, environmental disturbance, measurement noise, sensor drift, and control hardware limit. The state-of-the-art in X-ray microscopy at Advanced Photon Source (APS) at Argonne National Laboratory (ANL) features an H ∞ control architecture applied to only the optics stage or both the optics and sample stage, achieving the objectives of large tracking bandwidth over 200 Hz, good positioning resolution on the order of nanometers, rejection of environmental disturbance, attenuation of measurement noise, good Xray diffraction image resolution and increased imaging bandwidth. However, an unaddressed issue in our existing robust control design is that the sensors and the fixtures that hold the sensors drift with time due to changing air temperature in the APS beamline. Since the drift of sensor itself is not measured, it affects the relative position between the focusing optics and sample resulting into imaging artifacts and reduced image resolution. In this article, we demonstrate the rejection of the sensor drift by directly measuring the displacement of the sensor with respect to the global reference frame. Both the measured sensor displacement (i.e. sensor drift) and optics stage displacement are incorporated in the H ∞ control architecture to achieve the above mentioned objectives in addition to minimal relative displacement between the optics stage and the sample stage. This will improve the Xray image resolution and reduce image artifacts.

Robust Control↗

Density of jadeite melts under high pressure and high temperature conditions

The density of the jadeite (NaAlSi2O6) melt has been measured up to 6.5 GPa and 2273 K using the X–ray absorption technique at beamline 13–BM–D of the Advanced Photon Source. A fit of the pressure–density–temperature data to the high temperature Birch–Murnaghan equation of state yielded the following thermoelastic parameters: density, ρ0 = 2.36 g/cm3, isothermal bulk modulus, KT0 = 21.5 ± 0.8 GPa, its pressure derivative, K0' = 8.9 ± 1.2, and the temperature derivative (∂KT/∂T)P = -0.0021 ± 0.0011 GPa/K at a reference temperature T0 = 1473 K. The densification of jadeite melt at low pressures is primarily dominated by topological changes in the structure, including a decrease in T–O–T angle and breaking and reforming of the T–O bond (T = Si4+, Al3+). Compressibilities of jadeite, albite, diopside, phonolite and peridotite melts display a systematic trend: the K0–K0' plot of these silicate melts exhibits an inverse linear relation.

58 GEOSCIENCES↗

Use of X-Ray Fluorescence Microscopy for Studies on Research Models of Hepatocellular Carcinoma

Introduction: TheraSphere ® microspheres containing yttrium 90 Y are among many radioembolization agents used clinically to reduce liver tumor burden, and their effects on cancer volume reduction are well-established. At the same time, concerns about off target tissue injury often limit their use. Deeper investigation into tissue distribution and long-term impact of these microspheres could inform us about additional ways to use them in practice. Methods: Healthy rat liver and rabbit liver tumor samples from animals treated with TheraSpheres were sectioned and their elemental maps were generated by X-ray fluorescence microscopy (XFM) at the Advanced Photon Source (APS) synchrotron at Argonne National Laboratory (ANL). Results: Elemental imaging allowed us to identify the presence and distribution of TheraSpheres in animal tissues without the need for additional sample manipulation or staining. Ionizing radiation produced by 90 Y radioactive contaminants present in these microspheres makes processing TheraSphere treated samples complex. Accumulation of microspheres in macrophages was observed. Conclusions: This is the first study that used XFM to evaluate the location of microspheres and radionuclides in animal liver and tumor samples introduced through radioembolization. XFM has shown promise in expanding our understanding of radioembolization and could be used for investigation of human patient samples in the future.

60 APPLIED LIFE SCIENCES↗

Mechanisms of Pressure-Induced Phase Transitions by Real-Time Laue Diffraction

Synchrotron X-ray radiation Laue diffraction is a widely used diagnostic technique for characterizing the microstructure of materials. An exciting feature of this technique is that comparable numbers of reflections can be measured several orders of magnitude faster than using monochromatic methods. This makes polychromatic beam diffraction a powerful tool for time-resolved microstructural studies, critical for understanding pressure-induced phase transition mechanisms, by in situ and in operando measurements. The current status of this technique, including experimental routines and data analysis, is presented along with some case studies. The new experimental setup at the High-Pressure Collaborative Access Team (HPCAT) facility at the Advanced Photon Source, specifically dedicated for in situ and in operando microstructural studies by Laue diffraction under high pressure, is presented.

36 MATERIALS SCIENCE↗

Investigation of High-Energy Ion-Irradiated MA957 Using Synchrotron Radiation under In-Situ Tension

In this study, an MA957 oxide dispersion-strengthened (ODS) alloy was irradiated with high-energy ions in the Argonne Tandem Linac Accelerator System. Fe ions at an energy of 84 MeV bombarded MA957 tensile specimens, creating a damage region ~7.5 μm in depth; the peak damage (~40 dpa) was estimated to be at ~7 μm from the surface. Following the irradiation, in-situ high-energy X-ray diffraction measurements were performed at the Advanced Photon Source in order to study the dynamic deformation behavior of the specimens after ion irradiation damage. In-situ X-ray measurements taken during tensile testing of the ion-irradiated MA957 revealed a difference in loading behavior between the irradiated and un-irradiated regions of the specimen. At equivalent applied stresses, lower lattice strains were found in the radiation-damaged region than those in the un-irradiated region. This might be associated with a higher level of Type II stresses as a result of radiation hardening. The study has demonstrated the feasibility of combining high-energy ion radiation and high-energy synchrotron X-ray diffraction to study materials’ radiation damage in a dynamic manner.

36 MATERIALS SCIENCE↗

In Situ X-ray Radiography and Computational Modeling to Predict Grain Morphology in $\beta$-Titanium during Simulated Additive Manufacturing

The continued development of metal additive manufacturing (AM) has expanded the engineering metallic alloys for which these processes may be applied, including beta-titanium alloys with desirable strength-to-density ratios. To understand the response of beta-titanium alloys to AM processing, solidification and microstructure evolution needs to be investigated. In particular, thermal gradients (Gs) and solidification velocities (Vs) experienced during AM are needed to link processing to microstructure development, including the columnar-to-equiaxed transition (CET). In this work, in situ synchrotron X-ray radiography of the beta-titanium alloy Ti-10V-2Fe-3Al (wt.%) (Ti-1023) during simulated laser-powder bed fusion (L-PBF) was performed at the Advanced Photon Source at Argonne National Laboratory, allowing for direct determination of Vs. Two different computational modeling tools, SYSWELD and FLOW-3D, were utilized to investigate the solidification conditions of spot and raster melt scenarios. The predicted Vs obtained from both pieces of computational software exhibited good agreement with those obtained from in situ synchrotron X-ray radiography measurements. The model that accounted for fluid flow also showed the ability to predict trends unobservable in the in situ synchrotron X-ray radiography, but are known to occur during rapid solidification. A CET model for Ti-1023 was also developed using the Kurz–Giovanola–Trivedi model, which allowed modeled Gs and Vs to be compared in the context of predicted grain morphologies. Both pieces of software were in agreement for morphology predictions of spot-melts, but drastically differed for raster predictions. The discrepancy is attributable to the difference in accounting for fluid flow, resulting in magnitude-different values of Gs for similar Vs.

36 MATERIALS SCIENCE↗

High-Pressure Sound Velocity Measurements of Liquids Using In Situ Ultrasonic Techniques in a Multianvil Apparatus

Sound velocity and equation of state of liquids provide important constraints on the generation, presence, and transport of silicate and metallic melts in the Earth’s interior. Unlike their solid counterparts, these properties of liquids pose great technical challenges to high-pressure measurements and are poorly constrained. Here we present the technical developments that have been made at the GSECARS beamline 13-ID-D of the Advanced Photon Source for the past several years for determination of sound velocity of liquids using the ultrasonic techniques in a 1000-ton Kawai-type multianvil apparatus. Temperature of the sound velocity measurements has been extended to ~2400 K at 4 GPa and ~2000 K at 8 GPa to enable studies of liquids with very high melting temperatures, such as the silicate liquids.

58 GEOSCIENCES↗

The Terahertz Dynamics of an Aqueous Nanoparticle Suspension: An Inelastic X-ray Scattering Study

We used the high-resolution Inelastic X-ray Scattering beamline of the Advanced Photon Source at Argonne National Laboratory to measure the terahertz spectrum of pure water and a dilute aqueous suspension of 15 nm diameter spherical Au nanoparticles (Au-NPs). We observe that, despite their sparse volume concentration of about 0.5%, the immersed NPs strongly influence the collective molecular dynamics of the hosting liquid. We investigate this effect through a Bayesian inference analysis of the spectral lineshape, which elucidates how terahertz transport properties of water change upon Au-NP immersion. In particular, we observe a nearly complete disappearance of the longitudinal acoustic mode and a mildly decreased ability to support shear wave propagation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗