Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Facility for fast neutron irradiation tests of electronics at the ISIS spallation neutron source

The VESUVIO beam line at the ISIS spallation neutron source was set up for neutron irradiation tests in the neutron energy range above 10 MeV. The neutron flux and energy spectrum were shown, in benchmark activation measurements, to provide a neutron spectrum similar to the ambient one at sea level, but with an enhancement in intensity of a factor of 10{sup 7}. Such conditions are suitable for accelerated testing of electronic components, as was demonstrated here by measurements of soft error rates in recent technology field programable gate arrays.

43 PARTICLE ACCELERATORS↗

Neutrino Spectra and Uncertainties for MINOS

The MINOS experiment at Fermilab has released an updated result on muon disappearance. The experiment utilizes the intense source of muon neutrinos provided by the NuMI beam line. This note summarizes the systematic uncertainties in the experiment's knowledge of the flux and energy spectrum of the neutrinos from NuMI.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparative studies to the design of the interferometer at W7-X with respect to technical boundary conditions

For the optimisation of the beam line configuration of the multi-channel interferometer at the Wendelstein 7-X stellarator the probabilistic approach of Bayesian experimental design (BED) is applied. Parameters of physical interest are directly implemented as design criteria. The quality of the design is analysed according to its expected information gain (expected utility) about the parameters of interest, which enables one to compare different diagnostic configurations quantitatively. The focus of this work lies on the comparison of different technical approaches for the interferometer diagnostic. Different physical problems (high confinement regimes, neoclassical predictions) and their effect on the density distribution are applied as optimisation goals. The influence of the port system and the in-vessel components (retro-reflectors) is discussed. For this, the design was done with and without technical restrictions, the resulting expected utilities are compared and analysed. Furthermore, the impact of an additional beamline at a different toroidal position (congruent to the Thomson scattering diagnostic) is examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Study of the Observation Optics for the Thomson Scattering Planned at Wendelstein 7-X

The main aim of the Thomson scattering system is the measurement of electron temperature and density profiles with high time and spatial resolution. To cover the whole laser beam line (1.6 m) through the plasma cross section, two ports are provided for the observation optics, which image the scattering volumes (each with 28 mm length and 9 mm diameter) onto fiber bundles. The observation optics are important components of the diagnostic set-up, because their imaging properties determine the spectral and spatial resolution of the whole system. Therefore the design of the optics must be optimized according to the geometrical constrains of the observation ports in terms of position and dimensions. To optimize this optical engineering, the commercial ZEMAX program is used. The composition of the optical system is elaborated to minimize losses of collected light with wavelength from 700 nm up to 1064 nm. Environmental criteria (e.g. neutrons, ECR plasma heating and temperature) will be considered choosing optical materials. First results of calculations will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface Analytics in Support of the Development of Static AutoClean - an In-Situ Cleaning Process for Ion Implanters

Static AutoClean is a new in-situ cleaning strategy in development at ATMI registered that enables increased process efficiency and safety in the ion implantation process. Like the Dynamic in-situ AutoClean technology previously introduced and released by ATMI, Static AutoClean utilizes XeF{sub 2} chemistry for in-situ cleaning of hazardous contaminants and deposits. Static AutoClean, however, is targeted towards cleaning areas of the beam-line (like electrode insulators or source bushings) where cleaning efforts using Dynamic AutoClean may not be sufficient. An explanation of this cleaning strategy and results showing its effectiveness will be presented in a separate paper at this conference (S. Yedave et al.). This paper presents the surface analytical data and methods used to understand and evaluate the effectiveness of Static AutoClean in removing contaminants from surfaces within the source vacuum chamber. Energy Dispersive Spectroscopy (EDS) was used to track the magnitude and spatial distribution of contaminants present on the surfaces within various regions in the source chamber space of an implanter following ion source operation with a commonly used dopant gas. After in-situ cleaning, these same components and surfaces were re-evaluated by EDS to quantitatively determine the reduction in surface contaminants present within the chamber. Learnings regarding the distribution of implant process contamination within the source chamber as well as Static AutoClean's effectiveness in removing it will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detecting Diffraction at the LHC

Forward spectrometers and leading proton detectors--when combined with the powerful mainstream experiments at the LHC--will open up unparalleled physics opportunities in detecting complete high energy collision events in extreme conditions. The range of physics that will be accessed is huge: the small angle extensions of the ATLAS and CMS will effectively transform the LHC into a laboratory of gluon jets, deeply inelastic scattering and novel phenomena not accessed so far in any other experiment. A rapidity gap physics program of a superb potential can be realized at the LHC by adding a few simple forward shower counters (FSCs) along the beam line on both sides of the CMS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The FNAL e938 Experiment: The Mexican Contribution to the MINER{nu}A Collaboration

The MINER{nu}A (Main INjector ExpeRiment for {nu}A) collaboration (http://minerva.fnal.gov//) is a neutrino scattering experiment which uses the NuMI beam-line at Fermilab. It seeks to measure low energy neutrino interactions both to support neutrino oscillation experiments and to study the strong dynamics of the nucleon and nucleus that affect these interactions. It is currently in its final prototyping stage and is preparing for full-scale construction. The first detector module was completed in early 2006 and it is planned to begin taking data in 2009. We present an overview of this experiment, emphasizing the Mexican contribution, and giving the potential physics results that this collaboration can contribute to the physics of neutrino.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Intensity High-order Harmonics Generated from Low-Density Plasma

We study the generation of high-order harmonics from lowly ionized plasma, using the 10 TW, 10 Hz laser of the Advanced Laser Light Source (ALLS). We perform detailed studies on the enhancement of a single order of the high-order harmonic spectrum generated in plasma using the fundamental and second harmonic of the ALLS beam line. We observe quasi-monochromatic harmonics for various targets, including Mn, Cr, Sn, and In. We identify most of the ionic/neutral transitions responsible for the enhancement, which all have strong oscillator strengths. We demonstrate intensity enhancements of the 13th, 17th, 29th, and 33rd harmonics from these targets using the 800 nm pump laser and varying its chirp. We also characterized the attosecond nature of such plasma harmonics, measuring attosecond pulse trains with 360 as duration for chromium plasma, using the technique of 'Reconstruction of Attosecond Beating by Interference of Two-photon Transitions'(RABBIT). These results show that plasma harmonics are intense source of ultrashort coherent soft x-rays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visualization of water on through-plane direction of GDL using X-ray radiography

In this investigation, we visualized water distribution and behavior of water on through plane direction of GDL (Gas Diffusion Layer), which is one of components of PEMFC, using X-ray radiography. In order to investigate water distribution and behavior at GDL of PEMFC, the facilities was set up at the 7B2 beam line in Pohang Accelerator Laboratory. The phenomena of cathode side GDL is more important because the cathode side GDL has more water than the anode side. For this reason, the cathode side GDL was targeted and test section (Figure 1) was made to make similar boundary condition with a cathode side GDL of operating PEMFC. GDL faced two single channels. One is air channel as cathode gas channel of PEMFC and the other is liquid channel as cathode catalyst layer. Water is produced in cathode catalyst layer and almost of this water transport through cathode GDL. Because of this, liquid channel was adopted as catalyst layer. Images of water distribution were recorded per 4 second under various liquid pressure conditions. Water content was calculated from these images using mathematic process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cadmium Chemical Form in Mine Waste Materials by X-ray Absorption Spectroscopy

This study examines the molecular form of cadmium (Cd) present in mine wastes by X-ray Absorption Spectroscopy (XAS; Cd>20 mg/kg) using the K-edge of Cd at the Photon Factory Advanced Ring (PF-AR), NW10A beam line at KEK-Tsukuba-Japan. Mine waste materials and zinc concentrate were analyzed for Cd by ICPMS prior to undertaking XAS (range 21-452 mg/kg). Model compounds (CdO, Cd(OH){sub 2}, CdCO{sub 3}, Cdacetate, CdS, Cdstearate, CdDEDTC) and samples were examined in solid form at 20 K. The XANES spectra showed similar E max values for both model compounds and samples. The EXAFS showed that Cd-S in CdS, gives a flatter spectrum in the extended region compared to Cd-O found with CdCO{sub 3}, CdO and Cd Stearate. Linear combination fitting with model Cd compounds did not give clear assignments of composition, indicating that more detailed EXAFS spectra is required as mineral forms containing Cd were present rather than simple Cd compounds such as CdCO{sub 3}. The Cd bond for a single shell model in mine waste sample matrices appears to be either Cd-O or Cd-S, or a combination of both. Comparison of molecular data from the XAS studies with bioaccessibility data giving a prediction of bioavailability for mine waste materials provides useful information about the significance of the cadmium form as a contaminant for health risk assessment purposes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First Observation Of New Neutron-Rich Magnesium, Aluminum, and Silicon Isotopes

The investigation of the limits of nuclear existence is fundamental to the understanding of nuclear forces and structure. The limits of binding for very neutron-rich nuclei and the location of the neutron dripline are established experimentally only for the lightest elements. We report on the discovery of the new neutron-rich isotopes {sup 40}Mg, {sup 42,43}Al, and {sup 44}Si. These rare isotopes were produced at the National Superconducting Cyclotron Laboratory by fragmentation of a 141 MeV/u {sup 48}Ca beam on a tungsten target. The combination of the A1900 fragment separator together with the analysis beam line of the S800 spectrograph provided a two-stage fragment separation with exceptional selectivity. The observation of the odd-odd nucleus {sup 42}Al, which was predicted to be unbound by FRDM [1] and HFB-8 [2] models, is the first indication that the neutron drip line may be located significantly further towards heavier isotopes in this mass region than it is currently believed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvement of Vertical Diode Properties by N-type Plasma Doping for Low-Power Phase Change Non-Volatile Memory (NVM)

Using PH{sub 3} N-type plasma doing (PLAD), the device characteristics of high performance vertical switch diode for 50 nm phase-change NVM have been studied. Compared to the conventional beam line ion implantation, there are improvements of diode breakdown voltage (B.V.) and isolation B.V., respectively 20% and 41% by N-type PLAD doping due to the higher doping level and shallower profile in N+ region. It also shows excellent off-leakage properties less than 10 pA/cell without decreasing the Ion. From the results of this study, N-type PLAD has been demonstrated to be effective for vertical diode electrical properties as well as for high productivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultra-broadband infrared pump-probe spectroscopy using synchrotron radiation and a tuneable pump

Synchrotron infrared sources have become popular mainly because of their excellent broadband brilliance, which enables spectroscopically resolved spatial-mapping of stationary objects at the diffraction limit. In this article we focus on an often-neglected further advantage of such sources - their unique time-structure - to bring such broadband spectroscopy to the time domain, for studying dynamic phenomenon down to the 100 ps limit. We describe the ultra-broadband (12.5 to 1.1 {mu}m) Fourier transform pump-probe setup, for condensed matter transmission- and reflection-spectroscopy, installed at the X01DC infrared beam-line of the Swiss Light Source (SLS). The optical pump consists of a widely tuneable 100 ps 1 kHz laser system, covering 94% of the 16 to 1.1 {mu}m range. A thorough description of the system is given, including (i) the vector-modulator providing purely electronic tuning of the pump-probe overlap up to 1 ms with sub-ps time resolution, (ii) the 500 MHz data acquisition system interfaced with the experimental physics and industrial control system (EPICS) based SLS control system for consecutive pulse sampling, and (iii) the step-scan time-slice Fourier transform scheme for simultaneous recording of the dual-channel pumped, un-pumped, and difference spectra. The typical signal/noise ratio of a single interferogram in a 100 ps time slice is 300 (measured during one single 140 s TopUp period). This signal/noise ratio is comparable to that of existing gated Globar pump-probe Fourier transform spectroscopy, but brings up to four orders of magnitude better time resolution. To showcase the utility of broadband pump-probe spectroscopy, we investigate a Ge-on-Si material system similar to that in which optically pumped direct-gap lasing was recently reported. We show that the mid-infrared reflection-spectra can be used to determine the optically injected carrier density, while the mid- and near-infrared transmission-spectra can be used to separate the strong pump-induced absorption and inversion processes present at the direct-gap energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 2 MV Van de Graaff accelerator as a tool for planetary and impact physics research

Investigating the dynamical and physical properties of cosmic dust can reveal a great deal of information about both the dust and its many sources. Over recent years, several spacecraft (e.g., Cassini, Stardust, Galileo, and Ulysses) have successfully characterised interstellar, interplanetary, and circumplanetary dust using a variety of techniques, including in situ analyses and sample return. Charge, mass, and velocity measurements of the dust are performed either directly (induced charge signals) or indirectly (mass and velocity from impact ionisation signals or crater morphology) and constrain the dynamical parameters of the dust grains. Dust compositional information may be obtained via either time-of-flight mass spectrometry of the impact plasma or direct sample return. The accurate and reliable interpretation of collected spacecraft data requires a comprehensive programme of terrestrial instrument calibration. This process involves accelerating suitable solar system analogue dust particles to hypervelocity speeds in the laboratory, an activity performed at the Max Planck Institut fuer Kernphysik in Heidelberg, Germany. Here, a 2 MV Van de Graaff accelerator electrostatically accelerates charged micron and submicron-sized dust particles to speeds up to 80 km s{sup -1}. Recent advances in dust production and processing have allowed solar system analogue dust particles (silicates and other minerals) to be coated with a thin conductive shell, enabling them to be charged and accelerated. Refinements and upgrades to the beam line instrumentation and electronics now allow for the reliable selection of particles at velocities of 1-80 km s{sup -1} and with diameters of between 0.05 {mu}m and 5 {mu}m. This ability to select particles for subsequent impact studies based on their charges, masses, or velocities is provided by a particle selection unit (PSU). The PSU contains a field programmable gate array, capable of monitoring in real time the particles' speeds and charges, and is controlled remotely by a custom, platform independent, software package. The new control instrumentation and electronics, together with the wide range of accelerable particle types, allow the controlled investigation of hypervelocity impact phenomena across a hitherto unobtainable range of impact parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of vapor pressure enhancement of rare-earth metal-halide salts in the temperature range relevant to metal-halide lamps

Total vapor-phase densities of Dy in equilibrium with a DyI{sub 3}/InI condensate and Tm in equilibrium with a TmI{sub 3}/TlI condensate have been measured for temperatures between 900 K and 1400 K. The measurements show strong enhancements in rare-earth vapor densities compared to vapors in equilibrium with the pure rare-earth metal-halides. The measurements were made with x-ray induced fluorescence on the sector 1-ID beam line at the Advanced Photon Source. The temperature range and salt mixtures are relevant to the operation of metal-halide high-intensity discharge lamps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial distribution of elements in the spheroids by prostate tumor cells using synchrotron radiation x-ray fluorescence

The formation of three-dimensional cell microspheres such as spheroids has attracted attention as a useful culture technique. In this study, we investigated the trace elemental distribution (mapping) in spheroids derived from tissue prostate cancer (PCa). The measurements were performed in standard geometry of 45 deg. incidence, exciting with a white beam and using an optical capillary with 20 {mu}m diameter collimation in the XRF beam line at the Synchrotron Light National Laboratory (Campinas, Brazil). The results showed that most elements analyzed presented non-uniform distribution. P, S and Cl showed similar elemental distribution in all the samples analyzed. K, Ca, Fe, and Cu showed different elemental distribution for the spheroids analyzed. Zinc presented more intense distributions in the spheroid central region for all spheroids analyzed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma chemistry study of PLAD processes

Plasma doping (PLAD) shows very different impurity profiles compared to the conventional beam-line-based ion implantations due to its non-mass separation property and plasma environment. There is no simulation for PLAD process so far due to a lack of a dopant profile model. Several factors determine impurity profiles of PLAD process. The most significant factors are: plasma chemistry and deposition/etching characteristics of multi-ion species plasmas. In this paper, we present plasma chemistry and deposition/etching characteristics of PLAD processes versus co-gas dilutions. Four dopant plasmas including B{sub 2}H{sub 6}, BF{sub 3}, AsH{sub 3}, and PH{sub 3}, and two non-dopant plasmas including CH{sub 4} and GeH{sub 4} are studied and demonstrated.

36 MATERIALS SCIENCE↗

Reactive sputter magnetron reactor for preparation of thin films and simultaneous in situ structural study by X-ray diffraction

The purpose of the designed reactor is (i) to obtain polycrystalline and/or amorphous thin films by controlled deposition induced by a reactive sputtering magnetron and (ii) to perform a parallel in situ structural study of the deposited thin films by X-ray diffraction, in real time, during the whole growth process. The designed reactor allows for the control and precise variation of the relevant processing parameters, namely, magnetron target-to-sample distance, dc magnetron voltage, and nature of the gas mixture, gas pressure and temperature of the substrate. On the other hand, the chamber can be used in different X-ray diffraction scanning modes, namely, {theta}-2{theta} scanning, fixed {alpha}-2{theta} scanning, and also low angle techniques such as grazing incidence small angle X-ray scattering and X-ray reflectivity. The chamber was mounted on a standard four-circle diffractometer located in a synchrotron beam line and first used for a preliminary X-ray diffraction analysis of AlN thin films during their growth on the surface of a (100) silicon wafer.

36 MATERIALS SCIENCE↗