Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A continuous calibration of the ATLAS flavour-tagging classifiers via optimal transportation maps

A calibration of the ATLAS flavour-tagging algorithms using a new calibration procedure based on optimal transportation maps is presented. Simultaneous, continuous corrections to the b-jet, c-jet, and light-flavour jet classification probabilities from jet-tagging algorithms in simulation are derived for b-jets using $t\bar{t} \rightarrow e\mu \nu \nu bb$ data. After application of the derived calibration maps, closure between simulation and observation is achieved for jet flavour observables used in ATLAS analyses of Large Hadron Collider (LHC) Run 2 proton-proton collision data. This continuous calibration opens up new possibilities for the future use of jet flavour information in LHC analyses and also serves as a guide for deriving high-dimensional corrections to simulation via transportation maps, an important development for a broad range of inference tasks.

Aad, G. [Aix-Marseille Université] (ORCID:00000002↗

Improving 3D reconstruction quality for root phenotyping: assessing the impact of camera calibration and imaging parameters

Arate 3D reconstruction is essential for high-throughput plant phenotyping, particularly for studying complex structures such as root systems. While photogrammetry and Structure from Motion (SfM) techniques have become widely used for 3D root imaging, the camera settings used are often underreported in studies, and the impact of camera calibration on model accuracyccu remains largely underexplored in plant science. In this study, we systematically evaluate the effects of focus, aperture, exposure time, and gain settings on the quality of 3D root models made with a multi-camera scanning system. We show through a series of experiments that calibration significantly improves model quality, with focus misalignment and shallow depth of field (DoF) being the most important factors affecting reconstruction accuracy. Our results further show that proper calibration has a greater effect on reducing noise than filtering it during post-processing, emphasizing the importance of optimizing image acquisition rather than relying solely on computational corrections. This work improves the repeatability and accuracy of 3D root imaging for phenotyping pipelines by giving useful calibration guidelines. This leads to better trait quantification for use in crop research and plant breeding in downstream analysis.

3D reconstruction↗

Rapid measurement of soluble xylo-oligomers using near-infrared spectroscopy (NIRS) and multivariate statistics: calibration model development and practical approaches to model optimization

Rapid monitoring of biomass conversion processes using techniques such as near-infrared (NIR) spectroscopy can be substantially quicker and less labor-, resource-, and energy-intensive than conventional measurement techniques such as gas or liquid chromatography (GC or LC) due to the lack of solvents and preparation methods, as well as removing the need to transfer samples to an external lab for analytical evaluation. The purpose of this study was to determine the feasibility of rapid monitoring of a biomass conversion process using NIR spectroscopy combined with multivariate statistical modeling, and to examine the impact of (1) subsetting the samples in the original dataset by process location and (2) reducing the spectral range used in the calibration model on model performance. We develop multivariate calibration models for the concentrations of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids at multiple points in a biomass conversion process which produces and then purifies XOS compounds from sugar cane bagasse. A single model using samples from multiple locations in the process stream showed acceptable performance as measured by standard statistical measures. However, compared to the single model, we show that separate models built by segregating the calibration samples according to process location show improved performance. We also show that combining an understanding of the sample spectra with simple multivariate analysis tools can result in a calibration model with a substantially smaller spectral range that provides essentially equal performance to the full-range model. We demonstrate that real-time monitoring of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids concentration at multiple points in a process stream using NIR spectroscopy coupled with multivariate statistics is feasible. Segregation of sample populations by process location improves model performance. Models using a reduced spectral range containing the most relevant spectral signatures show very similar performance to the full-range model, reinforcing the importance of performing robust exploratory data analysis before beginning multivariate modeling.

09 BIOMASS FUELS↗

ECAL Calibration and Energy Resolution for a 10TeV Detector Geometry

In the pursuit of a muon collider operating at ~10 TeV center-of-mass-energy, designing a highly accurate and sensitive detector is crucial. Calorimetry plays a key part in any detector setup, as we rely on our calorimeters for energy reconstruction and particle identification. Therefore, an effective calorimeter must be extremely well-calibrated and achieve excellent resolution. This poster will report on efforts to achieve a comprehensive energy calibration of the electromagnetic calorimeter (ECAL) for our 10 TeV detector design. This calibration is necessary in order to achieve desired energy resolution for reconstructed photons across a wide range of energies (0-1TeV). We report on the challenges introduced by the new location of the solenoid in our latest 10 TeV detector design, the necessity of a calibration strategy that is both energy-dependent and angularly dependent, and the resulting effects on photon energy resolution.

Powers, Rose↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

PROTOCALC, a W -band Polarized Calibrator for Cosmic Microwave Background Telescopes: Application to Simons Observatory and CLASS

Current- and next-generation cosmic microwave background (CMB) experiments will measure polarization anisotropies with unprecedented sensitivities. The need for high precision in these measurements underscores the importance of gaining a comprehensive understanding of instrument properties, with a particular emphasis on the study of the beam properties, and especially their polarization characteristics and the measurement of the polarization angle. In this context, a major challenge lies in the scarcity of millimeter polarized astrophysical sources with sufficient brightness and calibration knowledge to meet the stringent accuracy requirements of future CMB missions. This led to the development of a drone-borne calibration source designed for the frequency band centered on approximately 90 GHz, matching a commonly used channel in ground-based CMB measurements. The Prototype Calibrator for Cosmology, PROTOCALC, has undergone thorough in-lab testing, and its properties have been subsequently modeled through simulation software integrated into the standard Simons Observatory analysis pipeline. Moreover, the PROTOCALC system has been tested in the field, having been deployed twice on calibration campaigns with CMB telescopes in the Atacama Desert. The data collected constrain the roll angle of the source with a statistical accuracy of 0$^°_•$045.

79 ASTRONOMY AND ASTROPHYSICS↗

Wet-radome attenuation in ARM cloud radars and its utilization in radar calibration using disdrometer measurements

Abstract. A relative calibration technique has been developed for the US Department of Energy's (DOE's) Atmospheric Radiation Measurement (ARM) user facility Ka-band ARM Zenith Radars (KAZRs). This method uses the signal attenuation caused by water on the radome to estimate reflectivity factor (Ze) offsets. The wet-radome attenuation (WRA) is assumed to follow a log-linear relationship with rainfall rate during light and moderate rain, as measured by a collocated surface disdrometer. The technique has an uncertainty of approximately 3 dB, due to factors such as disdrometer measurement error, rain variability between radar and disdrometer sample volumes, and the fitting function's uncertainty for the WRA behavior. A practical advantage of this WRA-based approach to shorter-wavelength radar monitoring is that, while it requires a reference disdrometer, it proves feasible for a wider range of collocated disdrometer measurements compared to traditional direct disdrometer comparison at the onset of light rain. This technique thus offers a cost-effective monitoring tool for remote or long-term radar deployments. This calibration technique was applied during the ARM Tracking Aerosol Convection Interactions Experiment (TRACER) from October 2021 through September 2022. The estimated Ze offsets were compared against traditional radar calibration and monitoring methods using available datasets from this campaign. Results show that the WRA-based offsets align closely with mean offsets found between cloud radars and from direct disdrometer comparison near the onset of rain, while also reflecting similar offset and campaign-long trends when compared to collocated, independently calibrated radar wind profilers. Nevertheless, overall, the KAZR Ze offsets estimated during TRACER remained stable at approximately 2 dB lower than the disdrometer estimates from the campaign start until the end of June 2022; afterward, the offsets increased to around 7 dB by the campaign's end. This increase is linked to a drop of about 1 dB in transmitter power toward the end of the project.

54 ENVIRONMENTAL SCIENCES↗

DMTN-222: Calibration Generation, Verification, Acceptance, and Certification

This technote defines the best practices to be used for calibration generation, the verification that that calibration meets requirements, and when deciding if the calibration should be accepted for use in processing at both the summit and USDF. Other aspects of calibration product management, including the contents of the appropriate "defaults" collection, are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Mariner Mars 1971 scan platform pointing calibration

A technique was devised for the Mariner Mars 1971 mission wherein both ground and in-flight calibrations were performed. A more analytical approach was used for ground calibration, and in-flight calibration was performed using narrow-angle television pictures of stars. The Mariner Mars 1971 calibration technique and results are summarized.

Pace, G. D.↗

Miniature pressure valve for on-board calibration of pressure transducers.

This paper describes the development and testing of a miniature one-pole, three-position pressure valve and actuation mechanism. This valve was designed primarily for installation with a pressure transducer directly in a wind-tunnel model, thereby reducing lag time effects resulting from long connecting tubes to the transducer. This valve provides for the in-situ calibration of the transducer during testing by providing one position for transducer zero, a second position for a known calibrate pressure, and a third position for measurement of the unknown test pressure. The valve is driven from the spring loaded test pressure position to the zero and calibrate positions by a pneumatically operated dual-piston yoke assembly. Large numbers of transducers can be simultaneously calibrated from a remote location in a matter of seconds.

Rollins, G. N.↗

Photometer calibration problem for extended astronomical sources

Analysis of calibration tests for the Skylab experimental T027 photometer is used to show that if an instrument is focused at infinity, the uniform extended calibration source should be positioned at distances at least equal to the hyperfocal distance and should be large enough to fill the field of view. It is noted that the field depth can be increased by focusing the optical system at the hyperfocal distance and that this method of focusing reduces the needed diameter of the calibration source to half that of a system focused at infinity. Other calibration methods discussed includes determining the radiance responsivity distance and extrapolating the curve to larger distances as well as extensive mapping of the spatial response combined with the irradiance responsivity to obtain the radiance responsivity.

Muscari, J. A.↗

Spectroradiometric calibration techniques in the far ultraviolet - A stable emission source for the Lyman bands of molecular hydrogen

The problems associated with making accurate spectroradiometric measurements in the far UV region are sketched briefly. The equipment and methods that were developed for providing absolute sensitivity calibration of an Apollo 17 far UV spectrometer are described. The absolute reference standards were photoelectric diodes calibrated at the National Bureau of Standards. A complete vacuum optical facility, which included a premonochromator and stable UV light sources, was developed to calibrate the Apollo 17 instrument, and it has been used for a number of other tasks. Absolute radiometric calibrations between about 1200 and 1700 A were performed with an absolute accuracy of + or - 10%. The light source, which was designed to provide a very stable light output, is a low-pressure molecular hydrogen lamp in which the pressure is stabilized by thermal control of uranium hydride powder.-

Fastie, W. G.↗

Absolute calibration of a hydrogen discharge lamp in the vacuum ultraviolet

A low-pressure hydrogen discharge lamp was calibrated for radiant intensity in the vacuum ultraviolet spectral region on an absolute basis and was employed as a laboratory standard source in spectrograph calibrations. This calibration was accomplished through the use of a standard photodiode detector obtained from the National Bureau of Standards together with onsite measurements of spectral properties of optical components used. The stability of the light source for use in the calibration of vacuum ultraviolet spectrographs and optical systems was investigated and found to be amenable to laboratory applications. The lamp was studied for a range of operating parameters; the results indicate that with appropriate peripheral instrumentation, the light source can be used as a secondary laboratory standard source when operated under preset controlled conditions. Absolute intensity measurements were recorded for the wavelengths 127.7, 158.0, 177.5, and 195.0 nm for a time period of over 1 month, and the measurements were found to be repeatable to within 11 percent.

Nealy, J. E.↗

High altitude calibration of solar cells using rockets

The use of sounding rockets for calibrating solar cells offers two principal advantages: there is no effect due to the terrestrial atmosphere and the cells are recoverable immediately after calibration. Four n/p photovoltaic cells were calibrated in space and successfully recovered from a NASA Aerobee rocket that reached a peak altitude of 251 km. Two of the cells were optically filtered with 0.6 to 0.9-micron bandpass filters. The short-circuit current agreed to within 4% of the laboratory calibration; variation of cell output due to atmospheric attenuation in the altitude range of 80 to 251 km was 0.4% for the unfiltered cells.

Thomas, N. L.↗

Development of dynamic calibration methods for POGO pressure transducers

Two dynamic pressure sources are described for the calibration of pogo pressure transducers used to measure oscillatory pressures generated in the propulsion system of the space shuttle. Rotation of a mercury-filled tube in a vertical plane at frequencies below 5 Hz generates sinusoidal pressures up to 48 kPa, peak-to-peak; vibrating the same mercury-filled tube sinusoidally in the vertical plane extends the frequency response from 5 Hz to 100 Hz at pressures up to 140 kPa, peak-to-peak. The sinusoidal pressure fluctuations can be generated by both methods in the presence of high pressures (bias) up to 55 MPa. Calibration procedures are given in detail for the use of both sources. The dynamic performance of selected transducers was evaluated using these procedures; the results of these calibrations are presented. Calibrations made with the two sources near 5 Hz agree to within 3% of each other.

Hilten, J. S.↗

Calibration of Viking imaging system pointing, image extraction, and optical navigation measure

Pointing control and knowledge accuracy of Viking Orbiter science instruments is controlled by the scan platform. Calibration of the scan platform and the imaging system was accomplished through mathematical models. The calibration procedure and results obtained for the two Viking spacecraft are described. Included are both ground and in-flight scan platform calibrations, and the additional calibrations unique to optical navigation.

Breckenridge, W. G.↗

Radiance calibration of the High Altitude Observatory white-light coronagraph on Skylab

The processing of over 35,000 photographs of the solar corona obtained by the white-light coronograph on Skylab is described. Calibration of the vast amount of data was complicated by temporal effects of radiation fog and latent image loss. These effects were compensated by imaging a calibration step wedge on each data frame. Absolute calibration of the wedge was accomplished through comparison with a set of previously calibrated glass opal filters. Analysis employed average characteristic curves derived from measurements of step wedges from many frames within a given camera half-load. The net absolute accuracy of a given radiance measurement is estimated to be 20%.

Poland, A. I.↗

Absolute flux density calibrations of radio sources: 2.3 GHz

A detailed description of a NASA/JPL Deep Space Network program to improve S-band gain calibrations of large aperture antennas is reported. The program is considered unique in at least three ways; first, absolute gain calibrations of high quality suppressed-sidelobe dual mode horns first provide a high accuracy foundation to the foundation to the program. Second, a very careful transfer calibration technique using an artificial far-field coherent-wave source was used to accurately obtain the gain of one large (26 m) aperture. Third, using the calibrated large aperture directly, the absolute flux density of five selected galactic and extragalactic natural radio sources was determined with an absolute accuracy better than 2 percent, now quoted at the familiar 1 sigma confidence level. The follow-on considerations to apply these results to an operational network of ground antennas are discussed. It is concluded that absolute gain accuracies within + or - 0.30 to 0.40 db are possible, depending primarily on the repeatability (scatter) in the field data from Deep Space Network user stations.

Freiley, A. J.↗