Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Images of the laser entrance hole from the static x-ray imager at NIF

The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60 {mu}m spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

vdisdrops (b1)

A disdrometer measures the drop size distribution and velocity of falling hydrometeors. The 2-dimensional video-disdrometer (VDIS) comprises video cameras capable of observing individual hydrometeors from views perpendicular to each other. Two CCD line scan cameras are directed towards the measurement area. Objects passing through the measurement area—which is determined by the cross-section of the two optical paths as seen from above—obstruct the light and are detected as shadows by the cameras. Each camera contains a small embedded computer responsible for handling the data-capture process, analysis of the data, and their conversion and compression into a format suitable for further processing. Subsequently the data are transferred to the computer used for instrument control and final analysis. In order to identify individual precipitation particles by matching their views as seen by each of the cameras, it is necessary to synchronize the shutter and control both cameras with a synchronous line trigger signal. To reconstruct observables like falling velocity, oblateness, etc. from the datastreams of the two cameras, the two optical paths are displaced vertically by about 6mm, typically. Measuring this distance and adjusting the background illumination are the two major calibration and maintenance tasks necessary for successful operation of the device.

54 ENVIRONMENTAL SCIENCES↗

High-speed Imaging of Global Surface Temperature Distributions on Hypersonic Ballistic-Range Projectiles

The NASA-Ames ballistic range provides a unique capability for aerothermodynamic testing of configurations in hypersonic, real-gas, free-flight environments. The facility can closely simulate conditions at any point along practically any trajectory of interest experienced by a spacecraft entering an atmosphere. Sub-scale models of blunt atmospheric entry vehicles are accelerated by a two-stage light-gas gun to speeds as high as 20 times the speed of sound to fly ballistic trajectories through an 24 m long vacuum-rated test section. The test-section pressure (effective altitude), the launch velocity of the model (flight Mach number), and the test-section working gas (planetary atmosphere) are independently variable. The model travels at hypersonic speeds through a quiescent test gas, creating a strong bow-shock wave and real-gas effects that closely match conditions achieved during actual atmospheric entry. The challenge with ballistic range experiments is to obtain quantitative surface measurements from a model traveling at hypersonic speeds. The models are relatively small (less than 3.8 cm in diameter), which limits the spatial resolution possible with surface mounted sensors. Furthermore, since the model is in flight, surface-mounted sensors require some form of on-board telemetry, which must survive the massive acceleration loads experienced during launch (up to 500,000 gravities). Finally, the model and any on-board instrumentation will be destroyed at the terminal wall of the range. For these reasons, optical measurement techniques are the most practical means of acquiring data. High-speed thermal imaging has been employed in the Ames ballistic range to measure global surface temperature distributions and to visualize the onset of transition to turbulent-flow on the forward regions of hypersonic blunt bodies. Both visible wavelength and infrared high-speed cameras are in use. The visible wavelength cameras are intensified CCD imagers capable of integration times as short as 2 ns. The infrared camera uses an Indium Antimonide (InSb) sensor in the 3 to 5 micron band and is capable of integration times as short as 500 ns. The projectiles are imaged nearly head-on using expendable mirrors offset slightly from the flight path. The proposed paper will discuss the application of high-speed digital imaging systems in the NASA-Ames hypersonic ballistic range, and the challenges encountered when applying these systems. Example images of the thermal radiation from the blunt nose of projectiles flying at nearly 14 times the speed of sound will be given.

Wilder, Michael C.↗

Determination of geometric distortion in STIS images

This is a report on the characterization of the geometric distortion of the Space Telescope Imaging Spectrograph (STIS) Charge Coupled Devices (CCD) and the STIS Far-Ultraviolet Multi-Anode Microchannel Arrays (FUV-MAMA) detectors when used in imaging mode. We find that the amount of the distortion is fairly small over most of the field. The maximum displacement is 1.66 pixels for the CCD and 2.71 pixels for the FUV-MAMA. This data also allows us to determine the plate scale for both cameras. For the CCD the scale is 0".05071 +/- 0".00007 /pixel. For the FUV-MAMA the scale is 0".02447 +/- 0".00001 /pixel in x and 0".02467 +/-0".00002 /pixel in y.

Malumuth, Eliot M.↗

Calibration of X-ray imaging devices for accurate intensity measurement

National Security Technologies (NSTec) has developed calibration procedures for X-ray imaging systems using NIST traceable sources. The X-ray sources that are used for calibration are both diode type and diode/fluorescer combinations. Calibrating the X-ray detectors is the key to accurate calibration of the X-ray sources. Both energy dispersive detectors and photodiodes measuring total flux were used. We have developed calibration techniques for the detectors using radioactive sources that are traceable to the National Institute of Standards and Technology (NIST). The German synchrotron at Physikalische Technische Bundestalt (PTB) is used to calibrate silicon photodiodes over the energy range from 50 eV to 60 keV. The measurements on X-ray cameras made using the NSTec X-ray sources have included the quantum efficiency averaged over all pixels, the camera counts per photon per pixel, and response variation across the sensor. The instrumentation required to accomplish the calibrations is described. X-ray energies ranged from 720 eV to 22.7 keV. The X-ray sources produce narrow energy bands, allowing us to determine the properties as a function of X-ray energy. The calibrations were done for several types of imaging devices. There were back illuminated and front illuminated CCD (charge coupled device) sensors, and a CID (charge injection device) type camera. The CCD and CID camera types differ significantly in some of their properties that affect the accuracy of X-ray intensity measurements. All cameras discussed here are silicon based. The measurements of quantum efficiency variation with X-ray energy are compared to models for the sensor structure. Cameras that are not back-thinned are compared to those that are.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space environment robot vision system

A prototype twin-camera stereo vision system for autonomous robots has been developed at Goddard Space Flight Center. Standard charge coupled device (CCD) imagers are interfaced with commercial frame buffers and direct memory access to a computer. The overlapping portions of the images are analyzed using photogrammetric techniques to obtain information about the position and orientation of objects in the scene. The camera head consists of two 510 x 492 x 8-bit CCD cameras mounted on individually adjustable mounts. The 16 mm efl lenses are designed for minimum geometric distortion. The cameras can be rotated in the pitch, roll, and yaw (pan angle) directions with respect to their optical axes. Calibration routines have been developed which automatically determine the lens focal lengths and pan angle between the two cameras. The calibration utilizes observations of a calibration structure with known geometry. Test results show the precision attainable is plus or minus 0.8 mm in range at 2 m distance using a camera separation of 171 mm. To demonstrate a task needed on Space Station Freedom, a target structure with a movable I beam was built. The camera head can autonomously direct actuators to dock the I-beam to another one so that they could be bolted together.

Wood, H. John↗

Measuring Pixel-Position Errors On CCD Imagers

Deviations of positions of pixels on charge-coupled-device (CCD) image detector from nominal rectangular grid pattern measured by method in which coherent-light interference fringes used as reference pattern. Conceived for use in determining pixel-position errors in astrometric cameras flown aboard spacecraft. Also applied to determination of similar errors in (and calibration of) terrestrial CCD cameras used as position sensors; for example, position-measuring cameras that are parts of robotic systems.

Shaklan, Stuart B.↗

TH-C-17A-01: Imaging Sensor Comparison for Real-Time Cherenkov Signal Detection From Tissue for Treatment Verification

Purpose: To identify the optimum imaging sensor for a clinical system that would provide real-time imaging of the surface beam profile on patients as novel visual information to radiation therapy technologists, and more rapidly collect clinical data for large-scale studies of Cherenkov applications in radiotherapy. Methods: Four camera types, CMOS, CCD, ICCD and EMICCD, were tested to determine proficiency in the detection of Cherenkov signal in the clinical radiotherapy setting, and subsequent maximum supportable frame rate. Where possible, time-gating between the trigger signal from the LINAC and the intensifiers was implemented to detect signal with room lighting conditions comparable to patient treatment scenarios. A solid water phantom was imaged by the EM-ICCD and ICCD to evaluate the minimum number of accumulations-on-chip required for adequate Cherenkov detection, defined as >200% electron counts per pixel over background signal. Additionally, an ICCD and EM-ICCD were used clinically to image patients undergoing whole-breast radiation therapy, to understand the impact of the resolution limitation of the EM-ICCD. Results: The intensifier-coupled cameras performed best at imaging Cherenkov signal, even with room lights on, which is essential for patient comfort. The tested EM-ICCD was able to support single-shot imaging and frame rates of 30 fps, however, the current maximum resolution of 512 × 512 pixels was restricting. The ICCD used in current clinical trials was limited to 4.7 fps at a 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths (30% QE vs current 7%) promises 16 fps at the same resolution at lower cost than the EM-ICCD. Conclusion: The ICCD with the better red wavelength QE intensifier was determined to be the best suited commercial-off-the-shelf camera to detect real-time Cherenkov signal and provide the best potential for real-time display of radiation dose on the skin during treatment. Funding is from grants from the NIH numbers R01CA109558 and R21EB017559.

60 APPLIED LIFE SCIENCES↗

Camera selection for real-time in vivo radiation treatment verification systems using Cherenkov imaging

Purpose: To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Methods: Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Results: Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. Conclusions: The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.

60 APPLIED LIFE SCIENCES↗

An example of the performance of the space telescope planetary camera

A ground-based CCD picture of the relatively local dwarf irregular galaxy Sextans B is used to simulate a Space Telescope Planetary Camera image of a similar galaxy at the distance of the Virgo cluster. The gains to be had with the Space Telescope are discussed graphically.

Hoessel, J. G.↗

Characteristics of liquid ethanol diffusion flames from mini tube nozzles

A series of experiments was conducted to explore the combustion characteristics of a diffusion flames from mini tubes fueled by liquid ethanol with visual observations of the flame shape, the dynamic liquid-vapor interface during phase change inside the capillary tubes and the tube outer surface temperature using CCD and IR cameras. As the fuel supply rate increased, the interface location rose to the tube exit and the temperature gradient on the outer tube surface increased, consequently the evaporating became much stronger and the interface tended to be unstable. The combustion characteristics are closely related to the rapid phase change and violent evaporation and interfacial dynamics, with the violent evaporation, actually explosive boiling, inducing an explosive flame. The intensity of the explosive flame became stronger as the flowrate increased with the maximum flame height, interface location movement, and sound intensity all significantly increasing. The periodicity of the explosive flame was directly proportional to the interface moving distance and inversely proportional to the fuel flow rate. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE CHANDRA CARINA COMPLEX PROJECT: DECIPHERING THE ENIGMA OF CARINA'S DIFFUSE X-RAY EMISSION

We present a 1.42 deg{sup 2} mosaic of diffuse X-ray emission in the Great Nebula in Carina from the Chandra X-ray Observatory Advanced CCD Imaging Spectrometer camera. After removing >14,000 X-ray point sources from the field, we smooth the remaining unresolved emission, tessellate it into segments of similar apparent surface brightness, and perform X-ray spectral fitting on those tessellates to infer the intrinsic properties of the X-ray-emitting plasma. By modeling faint resolved point sources, we estimate the contribution to the extended X-ray emission from unresolved point sources and show that the vast majority of Carina's unresolved X-ray emission is truly diffuse. Line-like correlated residuals in the X-ray spectral fits suggest that substantial X-ray emission is generated by charge exchange at the interfaces between Carina's hot, rarefied plasma and its many cold neutral pillars, ridges, and clumps.

79 ASTRONOMY AND ASTROPHYSICS↗

Kinetic equilibrium reconstruction and the impact on stability analysis of KSTAR plasmas

High fidelity kinetic plasma equilibrium reconstructions are an essential requirement for accurate stability and disruption prediction analyses to support continuous operation of high beta tokamak plasmas. The present kinetic equilibrium reconstructions of plasmas in the KSTAR device include plasma density and temperature profiles from Thomson scattering and ion temperature from charge exchange spectroscopy diagnostics, and allowance for fast particle pressure. In addition, up to 25 channels of motional Stark effect diagnostic data are used to constrain the magnetic field pitch angle profile in the plasma to produce a reliable computation of the safety factor, q, profile. In this work, H-mode plasmas exhibit clear pedestal characteristics in the reconstructed pressure profile compared to internal transport barrier or L-mode plasmas. The plasma configuration and vertical position of inner strike points are validated by CCD and infrared camera images. Ideal and resistive magnetohydrodynamic (MHD) stability analyses using the DCON and resistive DCON codes utilize these kinetic equilibrium reconstructions to compare to experimental plasma stability. Equilibria with sufficiently low convergence error can provide reliable computation of ideal and resistive MHD stability analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Return to Jupiter - Project Galileo

The mission profile, instrumentation, and mission objectives of the Galileo probe are described. Scheduled for Shuttle launch in 1986, with a boost from the Centaur upper stage, the probe will require over 2 yr to reach the Jovian system. An atmospheric entry probe will be released during Jupiter approach, and the orbiting module will relay the temperature, pressure, radio signals, spectroscopy, magnetometry, and particle counts, originating from the parachuting probe. The orbiting module will then continue on to a series of flybys and orbits around the Jovian moons by using a gravity assist from Jupiter after each pass of a moon. The orbiter will record spectrometric, radiometric, dust, visual, magnetic, and radio propagation data. The television camera is a CCD device with 640,000 diodes forming an 800 x 800 array in one square centimeter.

Johnson, T. V.↗

Sensors for the Hubble Space Telescope wide field and planetary cameras (1 and 2)

The technology of the wide field planetary camera (WFPC-2) CCD technology is examined with reference to the WFPC-1 experience. Strategies are presented for elimination of quantum efficiency (QE) hysteresis and implementation of maintenance-free QE stability, improved far-UV performance, on-orbit photometric calibrations, refinements in CCD electronics, and anticipated CCD particle radiation effects. Absorption depth vs. wavelength in silicon and a cross section of the CCD membrane are shown.

Trauger, John T.↗

Star-field identification algorithm

A description of a new star-field identification algorithm that is suitable for implementation on CCD-based imaging cameras is presented. The minimum identifiable star pattern element consists of an oriented star triplet defined by three stars, their celestial coordinates, and their visual magnitudes. The algorithm incorporates tolerance to faulty input data, errors in the reference catalog, and instrument-induced systematic errors.

Scholl, M. S.↗

Experimental demonstration of a star-field identification algorithm

A fault-tolerant, six-feature, all-sky star-field identification algorithm has been integrated with a CCD-based imaging camera. This autonomous intelligent camera identifies in real time any star field without a priori knowledge and requires a reference catalog incorporating fewer than 1000 stars. Observatory tests on star fields with this intelligent camera are described.

Scholl, M. S.↗