Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Engineering Atomic-to-Nano Scale Structural Homogeneity towards High Corrosion Resistance of Amorphous Magnesium-Based Alloys

Magnesium-based amorphous alloys have aroused broad interest in being applied in marine use due to their merits of lightweight and high strength. Yet, the poor corrosion resistance to chloride-containing seawater has hindered their practical applications. Herein, we propose a new strategy to improve the chloride corrosion resistance of amorphous Mg 65 Cu 15 Ag 10 Gd 10 alloys by engineering atomic-to-nano scale structural homogeneity, which is implemented by heating the material to the critical temperature of the liquid–liquid transition. By using various electrochemical, microscopic, and spectroscopic characterization methods, we reveal that the liquid–liquid transition can rearrange the local structural units in the amorphous structure, slightly decreasing the alloy structure’s homogeneity, accelerate the formation of protective passivation film, and, therefore, increase the corrosion resistance. Our study has demonstrated the strong coupling between an amorphous structure and corrosion behavior, which is available for optimizing corrosion-resistant alloys.

36 MATERIALS SCIENCE↗

Computational Thermodynamic Modeling of Hot Corrosion of Alloys Haynes 242 and Hastelloy TM N for Molten Salt Service in Advanced High Temperature Reactors

An evaluation of thermodynamic aspects of hot corrosion of the superalloys Haynes 242 and HastelloyTM N in the eutectic mixtures of KF and ZrF4 is carried out for development of Advanced High Temperature Reactor (AHTR). This work models the behavior of several superalloys, potential candidates for the AHTR, using computational thermodynamics tool (ThermoCalc), leading to the development of thermodynamic description of the molten salt eutectic mixtures, and on that basis, mechanistic prediction of hot corrosion. The results from these studies indicated that the principal mechanism of hot corrosion was associated with chromium leaching for all of the superalloys described above. However, HastelloyTM N displayed the best hot corrosion performance. This was not surprising given it was developed originally to withstand the harsh conditions of molten salt environment. However, the results obtained in this study provided confidence in the employed methods of computational thermodynamics and could be further used for future alloy design efforts. Finally, several potential solutions to mitigate hot corrosion were proposed for further exploration, including coating development and controlled scaling of intermediate compounds in the KF-ZrF4 system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Insights from a Recent Meeting: Current Status and Future Directions in Magnesium Corrosion Research

The United States Department of Energy Vehicle Technologies Office held a Technical Review Meeting entitled “Current Status and Future Directions in Magnesium Corrosion Research” at Oak Ridge National Laboratory in April 2016. Here current funded Mg corrosion projects presented their latest results, along with invited presentations from academic and industrial researchers in the area of Mg corrosion. This paper overviews select topics from the meeting, with an emphasis on relaying meeting discussion points regarding future needs in understanding and mitigating Mg corrosion, particularly for automotive applications. Topics highlighted include the need for pretreatments and coatings suitable for mass vehicle production of Mg components, particularly for dissimilar metal joints involving Mg, Al, or steel, and corrosion evaluation methods more relevant to automotive components and operating conditions. Finally, from a scientific perspective, the need for better fundamental understanding of Mg dissolution, hydrogen evolution, and film formation behavior was a recurring theme, as was phenomena related to microgalvanic coupling involving second phases and impurities in Mg.

33 ADVANCED PROPULSION SYSTEMS↗

Mitigating CO 2 Corrosion of Natural Gas Steel Pipelines by Thermal Spray Aluminum Coatings

We report internal pipeline corrosion due to carbon dioxide (CO 2 ) is a major challenge facing the oil and gas industry. The objective of this study was to investigate the corrosion behavior of aluminum (Al)-based alloys as sacrificial coatings to protect pipelines in a CO 2 -saturated aqueous electrolyte (3.5 wt% NaCl) at 4 bar CO 2 partial pressure (3 bar) and 40°C. The corrosion resistance of Al-based alloys and thermal spray coatings was evaluated in an electrochemical reaction autoclave using electrochemical methods (potentiodynamic polarization, linear polarization resistance, and electrochemical impedance spectroscopy). Post-corrosion surface characterization was performed by scanning electron microscopy equipped with energy-dispersive x-ray spectroscopy. The obtained data show Al-based alloys demonstrated promising protection against CO 2 corrosion with no breakaway degradation issues.

36 MATERIALS SCIENCE↗

Recent Developments on Microencapsulation for Autonomous Corrosion Protection

This work concerns recent progress in the development of a multifunctional smart coating based on microencapsulation for the autonomous control of corrosion. Microencapsulation allows the incorporation of desired corrosion control functionalities, such as early corrosion detection and inhibition through corrosion controlled release of corrosion indicators and inhibitors, as well as self-healing agent release when mechanical damage occurs.While proof-of-concept results have been reported previously, more recent efforts have been concentrated in technical developments to improve coating compatibility, synthesis procedure scalability, as well as fine tuning the release property of encapsulated active agents.

Corrosion↗

Microencapsulation Technologies for Corrosion Protective Coating Applications

Microencapsulation technologies for functional smart Coatings for autonomous corrosion control have been a research area of strong emphasis during the last decade. This work concerns the development of pH sensitive micro-containers (microparticles and microcapsules) for autonomous corrosion control. This paper presents an overview of the state-of-the-art in the field of microencapsulation for corrosion control applications, as well as the technical details of the pH sensitive microcontainer approach, such as selection criteria for corrosion indicators and corrosion inhibitors; the development and optimization of encapsulation methods; function evaluation before and after incorporation of the microcontainers into coatings; and further optimization to improve coating compatibility and performance.

Microencapsulation↗

SAVANNAH RIVER SITE TANK CLEANING: CORROSION RATE FOR ONE VERSUS EIGHT PERCENT OXALIC ACID SOLUTION

Until recently, the use of oxalic acid for chemically cleaning the Savannah River Site (SRS) radioactive waste tanks focused on using concentrated 4 and 8-wt% solutions. Recent testing and research on applicable dissolution mechanisms have concluded that under appropriate conditions, dilute solutions of oxalic acid (i.e., 1-wt%) may be more effective. Based on the need to maximize cleaning effectiveness, coupled with the need to minimize downstream impacts, SRS is now developing plans for using a 1-wt% oxalic acid solution. A technology gap associated with using a 1-wt% oxalic acid solution was a dearth of suitable corrosion data. Assuming oxalic acid's passivation of carbon steel was proportional to the free oxalate concentration, the general corrosion rate (CR) from a 1-wt% solution may not be bound by those from 8-wt%. Therefore, after developing the test strategy and plan, the corrosion testing was performed. Starting with the envisioned process specific baseline solvent, a 1-wt% oxalic acid solution, with sludge (limited to Purex type sludge-simulant for this initial effort) at 75 C and agitated, the corrosion rate (CR) was determined from the measured weight loss of the exposed coupon. Environmental variations tested were: (a) Inclusion of sludge in the test vessel or assuming a pure oxalic acid solution; (b) acid solution temperature maintained at 75 or 45 C; and (c) agitation of the acid solution or stagnant. Application of select electrochemical testing (EC) explored the impact of each variation on the passivation mechanisms and confirmed the CR. The 1-wt% results were then compared to those from the 8-wt%. The immersion coupons showed that the maximum time averaged CR for a 1-wt% solution with sludge was less than 25-mils/yr for all conditions. For an agitated 8-wt% solution with sludge, the maximum time averaged CR was about 30-mils/yr at 50 C, and 86-mils/yr at 75 C. Both the 1-wt% and the 8-wt% testing demonstrated that if the sludge was removed from the testing, there would be a significant increase in the CR. Specifically, the CR for an agitated 1-wt% pure oxalic acid solution at 45 or 75 C was about 4 to 10 times greater than those for a 1-wt% solution with sludge. For 8-wt% at 50 C, the effect was even larger. The lower CRs suggest that the cathodic reactions were altered by the sludge. For both the 1-wt% and 8-wt% solution, increasing the temperature did not result in an increased CR. Although the CR for a 1-wt% acid with sludge was considered to be non-temperature dependent, a stagnant solution with sludge resulted in a CR that was greater at 45 C than at 75 C, suggesting that the oxalate film formed at a higher temperature was better in mitigating corrosion. For both a 1 and an 8-wt% solution, agitation typically resulted in a higher CR. Overall, the testing showed that the general CR to the SRS carbon steel tanks from 1-wt% oxalic acid solution will remain bounded by those from an 8-wt% oxalic acid solution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rhenium Uptake as Analogue for 99Tc by Steel Corrosion Products

Static batch experiments were used to examine the sorption of dissolved perrhenate [Re(VII)], as a surrogate for pertechnetate [Tc(VII)], on corrosion products of A-516 carbon steel coupons contacted with synthetic groundwater or dilute water. After 109 days of contact time, the concentration of dissolved Re(VII) in the synthetic groundwater matrix decreased by approximately 26%; the dilute water matrix experienced a 99% decrease in dissolved Re(VII) over the same time period. Bulk x-ray diffraction (XRD) results for the corroded steel coupons showed that the corrosion products consisted primarily of maghemite, lepidocrocite, and goethite. Analyses of the coupons by scanning electron microscopy/energy dispersive spectroscopy (SEM/EDS) indicated that Re was present with the morphologically complex assemblages of Fe oxide/hydroxide corrosion products for samples spiked with the highest dissolved Re(VII) concentration (1.0 mmol/L) used for these experiments. Analyses of corroded steel coupons contacted with solutions containing 1.0 mmol/L Re(VII) by synchrotron-based methods confirmed the presence of Re sorbed with the corrosion product on the steel coupons. Analyses showed that the Re sorbed on these corroded coupons was in the +7 oxidation state, suggesting that the Rep14 uptake mechanism did not involve reduction of Re to a lower oxidation state, such as +4. The results of our studies using Re(VII) as an analogue for {sup 99}Tc(VII) suggest that {sup 99}Tc(VII) would also be sorbed with steel corrosion products and that the inventory of {sup 99}Tc(VII) released from breached waste packages would be lower than what is now conservatively estimated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CORROSION TESTING OF CARBON STEEL IN OXALIC ACID CHEMICAL CLEANING SOLUTIONS

Radioactive liquid waste has been stored in underground carbon steel tanks for nearly 60 years at the Savannah River Site. The site is currently in the process of removing the waste from these tanks in order to place it into vitrified, stable state for longer term storage. The last stage in the removal sequence is a chemical cleaning step that breaks up and dissolves metal oxide solids that cannot be easily pumped out of the tank. Oxalic acid has been selected for this purpose because it is an effective chelating agent for the solids and is not as corrosive as other acids. Electrochemical and immersion studies were conducted to investigate the corrosion behavior of carbon steel in simulated chemical cleaning environments. The effects of temperature, agitation, and the presence of sludge solids in the oxalic acid on the corrosion rate and the likelihood of hydrogen evolution were determined. The testing showed that the corrosion rates decreased significantly in the presence of the sludge solids. Corrosion rates increased with agitation, however, the changes were less noticeable.

08 HYDROGEN↗

Materials corrosion in molten LiF-NaF-KF eutectic salt under different reduction-oxidation conditions

Molten fluoride salts such as FLiNaK (LiF-NaF-KF: 46.5-11.5-42 mol %) have been proposed for use as secondary reactor coolants, media for transfer of high temperature process heat from nuclear reactors to chemical plants, and for concentrated solar power thermal energy storage. In molten fluoride salts, passive oxide films are chemically unstable, and corrosion is driven largely by the thermodynamically driven dissolution of alloying elements into the molten salt environment. Two alloys, Hastelloy{sup R} N and 316L stainless steel were exposed to molten FLiNaK salt in a 316L stainless steel crucible under argon cover gas for 1000 hours at 850 deg. C. Graphite was present in some of the crucibles with the goal of studying corrosion behavior of relevant reactor material combinations. In addition, a technique to reduce alloy corrosion through modification of the reduction-oxidation state was tested by the inclusion of zirconium to the system. Corrosion of 316L stainless steel was noted to occur primarily through surface depletion of chromium, an effect that was enhanced by the presence of graphite. Hastelloy{sup R} N experienced weight gain through electrochemical plating of corrosion products derived from the 316L stainless steel crucible. In the presence of zirconium, both alloys gained weight through plating of zirconium and as a result formed intermetallic layers. (authors)

36 MATERIALS SCIENCE↗

Corrosion Control during Closure Activities at the Savannah River Site - 13514

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during normal service and design basis events (e.g., earthquake conditions). A corrosion control program is in place to ensure that degradation of the steel does not impact the structural and leak integrity functions of these waste tanks. The SRS is currently retrieving waste from older waste tanks and processing the waste through the vitrification for long term stabilization. The retrieval processes prepare the tanks for ultimate closure (i.e., grouting) by removing sludge by mechanical and/or sluicing methods, dissolving salt cake by adding water, and chemical cleaning of the residual sludge with oxalic acid. Each of these retrieval methods will result in waste chemistry that does not meet the requirements of the current corrosion control program. Given the short-term exposure and limited remaining service life for the tanks in which retrievals are being performed, an assessment of the need for corrosion controls in these tanks was performed. The assessment reviewed the corrosion rates in the more aggressive environments and the postulated loads on the structure during the closure activities. The assessment concluded that the current corrosion control program may be suspended for a short period of time while final retrieval of the waste is performed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zirconium Alloy Corrosion and Hydrogen Pickup

During operation nuclear fuel rods are immersed in the primary water, causing waterside corrosion and consequent hydrogen ingress. The mechanisms of corrosion and hydrogen pickup and the role of alloy selection in minimizing both phenomena are considered, based on two principal characteristics: the pre-transition kinetics and the loss of oxide protectiveness at transition. In zirconium alloys very small changes in composition or microstructure can cause significant corrosion differences, so that corrosion performance is strongly alloy dependent. The alloys show different, but reproducible sub-parabolic pre-transition kinetics and transition thicknesses. A mechanism for oxide growth and breakup based on a detailed study of the oxide structure can explain these results. Using the recently developed Coupled Current Charge Compensation model of corrosion kinetics and hydrogen pickup, the sub-parabolic kinetics and the hydrogen fraction can be rationalized: hydrogen pickup increases when electron transport decreases, requiring hydrogen ingress to close the reaction. (authors)

36 MATERIALS SCIENCE↗

Development of neural network force fields for corrosion studies

To fully understand the chemistry and physics of corrosion, novel methods of simulation must be developed. One approach is designing machine learning (ML) algorithms integrated with density functional theory to develop adaptive force fields to gain insight into corrosion behavior namely at the surface of metal oxides. Current methods of modeling corrosion are slow due to the computational cost of resolving both reaction mechanics and mass transport processes. Machine learning methods can be implemented to obtain structure-activity relationships at both the molecular and bulk scale while still retaining the accuracy of density functional theory (DFT) and significantly decreasing the time needed for simulations of complex chemical processes in the various environments of corrosion. Multiscale models are needed for corrosion studies to fully understand its processes not only at the atomic length scale (chemical bonding, energies, and forces), but also at the nano and meso length scales (solid-state physics and material science processes). Current methods of study include DFT, molecular dynamics, and Monte Carlo. The limitation of DFT is that only a small number of atoms or molecules can be simulated at that level of theory. Density functional theory is used to study the electronic structure of atoms and molecules, and calculate the force component of each atom. However, these calculations are limited to about 1000 atoms. Custom periodic boundary conditions (PBC) can be used to describe the various environments and defects that affect the atomic forces to produce a large data set from which a training set can be derived. Machine learning can be utilized to overcome the barrier of modeling macroscopic and multi-scale processes from ab initio calculations through the development of adaptive force fields. Local environments determine the atomic forces of a given system, therefore adaptive force fields must be created to produce reliable quantum mechanical calculations. This can be achieved by developing a learning algorithm that uses the mapped atomic forces or fingerprint as an input to produce energies and magnetic moments as output. A systematic approach was used to begin to build a data set in order to accurately describe the atomic forces in various environments. In Figure 4 below, a simple PBC cell of Fe{sub 2}O{sub 3} was first optimized. A surface optimization was performed next, followed by a hydroxylated surface optimization. Once this calculation has converged, the adsorption of halide species to the hydroxylated surface will be investigated. TensorFlow is an open source platform for machine learning developed by Google. Using a high level application program interface (API) such as Keras allows for building and training ML models easily in a number of different environments and languages. For this project, a neural network was developed within Anaconda in Python. Future Work: Further development of reference data set; Refining neural network and learning algorithm; Fingerprinting atomic environment to enable mapping of atomic force components; Choosing appropriate training set from reference data; Learning from training set and enabling non-linear mapping of training set fingerprints and the atomic forces; Estimation of uncertainty to identify ranges of outside applicability; Testing and analysis of molecular dynamic simulations.

36 MATERIALS SCIENCE↗

Elucidating the corrosion mechanism of commercial Ni-based Superalloys in UCl3 containing-chloride Molten Salt Systems

Molten salt reactors (MSRs) have gained renewed interest, providing several advantages over their predecessors, including the capability to consume spent fuels, enhancing the environmental sustainability of the uranium fuel cycle. For example, molten chloride fast reactors (MCFRs) can reach criticality with molten chloride spent fuel containing high concentrations of impurities, such as actinide products like uranium chloride (UCl3). However, the redox potential of chloride molten salt fuels may change in the presence of these impurities, dictating their corrosivity and in turn the corrosion performance of structural components, such as those constructed from nickel (Ni)-based alloys. The purpose of this investigation is to assess the extent of corrosion of Ni-based alloy, Inconel 617, when exposed to UCl3-LiCl-KCl eutectic salt. Inconel 617 one of only six structural materials that are fully qualified by the American Society for Mechanical Engineers (ASME) Boiler and Pressure Vessel Code for high-temperature nuclear reactor components, making it a technologically mature material to consider for constructing MCFRs. Inconel 617 specimens were submerged in a static LiCl-KCl-UCl3 eutectic salt mixture heated at 700 C for 1000 h under an inert atmosphere. Upon completion, the extent of corrosion was analyzed through a multi-modal characterization approach spanning the engineering to nanoscale, employing computed tomography, focused-ion beam, and transmission electron microscopy techniques. Results from this investigation will enhance our understanding of property-to-performance relationships of candidate structural materials for MSRs with respect to corrosion resistance and interactions between the salt and alloy interface.

36 MATERIALS SCIENCE↗

Elucidating the corrosion mechanism of commercial Ni-based superalloys in UCl3 containing-chloride molten salt systems

Elucidating the role of UCl3 in the corrosion mechanism of Ni-based superalloys exposed to chloride molten salts Trishelle Copeland-Johnson1, Michael Woods1, Ruchi Gakhar1, Daniel J. Murray1, Guoping Cao1, Lingfeng He1 1Idaho National Laboratory, Idaho Falls, ID, United States The United States Department of Energy (DOE) aims to diversify the domestic energy portfolio towards more sustainable options, including implementation of molten salt reactor (MSR) technology. Chloride molten salts have been investigated as an appropriate MSR coolant and fuel because their relatively inexpensive, abundant, and exhibit favorable thermophysical properties. However, the corrosivity of chloride molten salts have not been extensively studied, especially with the inclusion of actinide products, such as UCl3. Accordingly, the development of nuclear structural materials with excellent corrosion performance is critical to the successful implementation of MSRs, particularly from a mechanistic perspective. In this investigation, we attempt to elucidate the interfacial corrosion mechanism between Ni-based structural materials, such as Inconel 617, and UCl3-containing salt systems through a multi-modal advanced characterization approach, including electron microscopy techniques. The findings from this investigation will expand the knowledgebase of chloride molten salt corrosion of MSR structural materials for strategic property-to-performance design.

36 - MATERIALS SCIENCE↗

Corrosion behavior of technetium waste forms exposed to various aqueous environments

Technetium is a long-lived beta emitter produced in high yields from uranium as a waste product in spent nuclear fuel and has a high degree of environmental mobility as pertechnetate. It has been proposed that Tc be immobilized into various metallic waste forms to prevent Tc mobility while producing a material that can withstand corrosion exposed to various aqueous medias to prevent the leachability of Tc to the environment over long periods of time. This study investigates the corrosion behavior of Tc and Tc alloyed with 316 stainless steel and Zr exposed to a variety of aqueous media. To date, there is little investigative work related to Tc corrosion behavior and less related to potential Tc containing waste forms. Results indicate that immobilizing Tc into stainless steel-zirconium alloys can be a promising technique to store Tc for long periods of time while reducing the need to separately store used nuclear fuel cladding. Initial results indicate that metallic Tc and its alloys actively corrode in all media. We present preliminary corrosion rates of 100% Tc, 10% Tc - 90% SS{sub 85%}Zr{sub 15%}, and 2% Tc - 98% SS{sub 85%}Zr{sub 15%} in varying concentrations of nitric acid and pH 10 NaOH using the resistance polarization method while observing the trend that higher concentrations of Tc alloyed to the sample tested lowers the corrosion rate of the proposed waste package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Behavior of Wire Electrical Discharge Machined Surfaces of P91 Steel

The extensive usage of P91 steel in certain reactor components requires its precision fabrication by wire electrical discharge machining (WEDM). The WEDM cut surfaces consist of primarily re-melted and solidified layer (recast layer) of 2-8 µm. The recast layer is a result of fast removal of heat by unaffected metallic substrate and dielectric medium leading to rapid cooling. The WEDM surface is expected to affect the component performance in terms of its corrosion properties. The microstructural changes taking place due to EDM cutting of P91 steel bring about a drastic change in the electrochemical response of surface as compared to that for bulk P91 steel. The surface microstructure is shown to alter the passivation behavior and resistance to localized corrosion. Electrochemical polarization studies were done to evaluate passivation, pitting and intergranular corrosion (IGC) behavior and field emission gun—scanning electron microscopy was used for microstructural characterization of P91 steel surfaces. The passivation behavior for P91 steel WEDM cut surfaces was better than that for diamond polished surface. But pitting corrosion resistance decreased for the P91 steel WEDM surface which is a result of inhomogeneities in the microstructure of recast layer. The IGC resistance though increased due to the decreased grain size in the surface layer.

36 MATERIALS SCIENCE↗

Few-Layers Graphene Film and Copper Surface Morphology for Improved Corrosion Protection of Copper

Graphene has shown excellent corrosion protection of copper (Cu). The corrosion protection of Cu is governed by the characteristics of the deposited graphene and Cu surface morphology underneath. In this work, graphene films (1-2, 4-5 layers) were deposited on Cu using a chemical vapor deposition by changing hydrogen (H{sub 2}) concentration during the annealing stage. The chemical structure and surface microstructural features of graphene/Cu were inspected by Raman spectroscopy, scanning electron microscopy, transmission electron microscopy, and atomic force microscopy. The electrochemical corrosion performance of graphene/Cu was studied in 0.5 M sodium chloride solution using potentiodynamic polarization and electrochemical impedance spectroscopic measurements. The 1-2 layers of graphene and rough Cu surface were obtained for low H{sub 2} concentrations (0 and 2.5%), whereas high H{sub 2} concentrations, 20 and 50%, resulted in a smooth Cu surface and 4-5 layers of graphene. Our results showed that Cu with a smooth surface and multilayer graphene film exhibited the best corrosion resistance against electrochemical degradation. Tafel analysis revealed that Cu with 4-5 layers of graphene coating corroded nearly three orders of magnitude slower than the annealed Cu, without graphene coating. The results of this study can be useful for several applications where Cu is in close contact with salt species.

36 MATERIALS SCIENCE↗