Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Spectroscopic determination of thermal impulse in sub-second heating events using lanthanide-doped oxide precursors and phenomenological modeling

Using a mixture of crystalline-Ho:ZrO{sub 2}, precursor-Dy:Y{sub 2}O{sub 3}, and precursor-Eu:ZrO{sub 2} nanoparticles we develop thermal impulse sensors capable of measuring equivalent isothermal temperatures and durations during a heating event, with response times of <100 ms, and a temperature range of at least 673 K to 1173 K. In order to determine the temperature and duration from the sensors after the heating event we measure the sensors' fluorescence spectrum, which is then compared with lab based calibration data. By using two precursor materials with different reaction kinetics we are able to extract both temperature and duration. Based on blind sample testing we find that the sensors and calculation method are accurate for measuring temperature and duration, but currently suffer a lack of precision due to difficulties in producing homogeneously heated samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-677: Reproducibility of Production of Ionization Chambers

Purpose: To compare the reproducibility of the production of several cylindrical and plane-parallel chambers popular in Poland in terms of a calibration coefficient. Methods: The investigation was performed for PTW30013 (20 chambers), 30001 (10 chambers), FC65-G (17 chambers) cylindrical chambers and for PPC05 (14 chambers), Roos 34001 (8 chambers) plane parallel chambers. The calibration factors were measured at the same accredited secondary standard laboratory in terms of a dose to water. All the measurements were carried out at the same laboratory, by the same staff, in accordance with the same IAEA recommendations. All the chambers were calibrated in the Co60 beam. Reproducibility was described in terms of the mean value, its standard deviation and the ratio of the maximum and minimum value of calibration factors for each set of chambers separately. The combined uncertainty budged (1SD) calculated according to the IAEA-TECDOC-1585 of the calibration factor was of 0.25%. Results: The calibration coefficients for PTW30013, 30001, and FC65-G chambers were 5.36±0.03, 5.28±0.06, 4.79±0.015 nC/Gy respectively and for PPC05, and Roos chambers were 59±2, 8.3±0.1 nC/Gy respectively. The maximum/minimum ratio of calibration factors for PTW30013, 30001, FC65-G, and for PPC05, Roos chambers were 1.03, 1.03, 1.01, 1.14 and 1.03 respectively. Conclusion: The production of all ion chambers was very reproducible except the Markus type PPC05 for which the ratio of maximum/minimum calibration coefficients of 1.14 was obtained.

07 ISOTOPE AND RADIATION SOURCES↗

Increased Fidelity in Prediction Methods For Landing Gear Noise

An aeroacoustic prediction scheme has been developed for landing gear noise. The method is designed to handle the complex landing gear geometry of current and future aircraft. The gear is represented by a collection of subassemblies and simple components that are modeled using acoustic elements. These acoustic elements are generic, but generate noise representative of the physical components on a landing gear. The method sums the noise radiation from each component of the undercarriage in isolation accounting for interference with adjacent components through an estimate of the local upstream and downstream flows and turbulence intensities. The acoustic calculations are made in the code LGMAP, which computes the sound pressure levels at various observer locations. The method can calculate the noise from the undercarriage in isolation or installed on an aircraft for both main and nose landing gear. Comparisons with wind tunnel and flight data are used to initially calibrate the method, then it may be used to predict the noise of any landing gear. In this paper, noise predictions are compared with wind tunnel data for model landing gears of various scales and levels of fidelity, as well as with flight data on fullscale undercarriages. The present agreement between the calculations and measurements suggests the method has promise for future application in the prediction of airframe noise.

Lopes, Leonard V.↗

Spectral mixture modeling - A new analysis of rock and soil types at the Viking Lander 1 site

A Viking Lander 1 image was modeled as mixtures of reflectance spectra of palagonite dust, gray andesitelike rock, and a coarse rocklike soil. The rocks are covered to varying degrees by dust but otherwise appear unweathered. Rocklike soil occurs as lag deposits in deflation zones around stones and on top of a drift and as a layer in a trench dug by the lander. This soil probably is derived from the rocks by wind abrasion and/or spallation. Dust is the major component of the soil and covers most of the surface. The dust is unrelated spectrally to the rock but is equivalent to the global-scale dust observed telescopically. A new method was developed to model a multispectral image as mixtures of end-member spectra and to compare image spectra directly with laboratory reference spectra. The method for the first time uses shade and secondary illumination effects as spectral end-members; thus the effects of topography and illumination on all scales can be isolated or removed. The image was calibrated absolutely from the laboratory spectra, in close agreement with direct calibrations. The method has broad applications to interpreting multispectral images, including satellite images.

Adams, J. B.↗

Self-calibrating the look-elsewhere effect: fast evaluation of the statistical significance using peak heights

In experiments where one searches a large parameter space for an anomaly, one often finds many spurious noise-induced peaks in the likelihood. This is known as the look-elsewhere effect, and must be corrected for when performing statistical analysis. Here, this paper introduces a method to calibrate the false alarm probability (FAP), or p-value, for a given dataset by considering the heights of the highest peaks in the likelihood. Specifically, we derive an equation relating the global p-value to the rank and height of local maxima. In the simplest form of self-calibration, the look-elsewhere-corrected $\chi^2$ of a physical peak is approximated by the $\chi^2$ of the peak minus the $\chi^2$ of the highest noise-induced peak, with accuracy improved by considering lower peaks. In contrast to alternative methods, this approach has negligible computational cost as peaks in the likelihood are a byproduct of every peak-search analysis. We apply to examples from astronomy, including planet detection, periodograms, and cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Prime VI

SAND2025-03757O Prime VI is a distribution-of-disease outbreak model calibration code based on variational inference. It accompanies a publication for submission to Statistics in Medicine journal, and the code will be maintained for open-source use on Sandia's GitLab. The software provides methods for calibrating an epidemiological model to measured case-count data for a multitude of correlated spatial regions. The code solves a Bayesian inverse problem for model calibration where the posterior over-model parameters are approximated through a custom implementation of variational inference. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Safta, Cosmin↗

Mariner 9 television calibration - Revisited

Mariner 9 TV data from the 1971-1972 encounter with Mars, which contain good synoptic coverage of of the planet as well as the highest-resolution images thus far obtained for the south polar region, can lead to more accurate photometric analysis if subjected to improved processing methods. While calibration errors are rather greater than those of the Viking Orbiter cameras, both calibration data and processing software applicable to an improvement program have become available through the USGS's Planetary Image Cartography System.

Herkenhoff, Ken E.↗

Sensitivity and Calibration of Non-Destructive Evaluation Method That Uses Neural-Net Processing of Characteristic Fringe Patterns

This paper answers some performance and calibration questions about a non-destructive-evaluation (NDE) procedure that uses artificial neural networks to detect structural damage or other changes from sub-sampled characteristic patterns. The method shows increasing sensitivity as the number of sub-samples increases from 108 to 6912. The sensitivity of this robust NDE method is not affected by noisy excitations of the first vibration mode. A calibration procedure is proposed and demonstrated where the output of a trained net can be correlated with the outputs of the point sensors used for vibration testing. The calibration procedure is based on controlled changes of fastener torques. A heterodyne interferometer is used as a displacement sensor for a demonstration of the challenges to be handled in using standard point sensors for calibration.

Decker, Arthur J.↗

Let Each Quantum Bit Choose Its Basis Gates

Near-term quantum computers are primarily limited by errors in quantum operations (or gates) between two quantum bits (or qubits). A physical machine typically provides a set of basis gates that include primitive 2-qubit (2Q) and 1-qubit (1Q) gates that can be implemented in a given technology. 2Q entangling gates, coupled with some 1Q gates, allow for universal quantum computation. In superconducting technologies, the current state of the art is to implement the same 2Q gate between every pair of qubits (typically an XX-or XY-type gate). This strict hardware uniformity requirement for 2Q gates in a large quantum computer has made scaling up a time and resource-intensive endeavor in the lab. We propose a radical idea – allow the 2Q basis gate(s) to differ between every pair of qubits, selecting the best entangling gates that can be calibrated between given pairs of qubits. This work aims to give quantum scientists the ability to run meaningful algorithms with qubit systems that are not perfectly uniform. Scientists will also be able to use a much broader variety of novel 2Q gates for quantum computing. We develop a theoretical framework for identifying good 2Q basis gates on “nonstandard” Cartan trajectories that deviate from “standard” trajectories like XX. We then introduce practical methods for calibration and compilation with nonstandard 2Q gates, and discuss possible ways to improve the compilation. To demonstrate our methods in a case study, we simulated both standard XY-type trajectories and faster, nonstandard trajectories using an entangling gate architecture with far-detuned transmon qubits. We identify efficient 2Q basis gates on these nonstandard trajectories and use them to compile a number of standard benchmark circuits such as QFT and QAOA. Furthermore, our results demonstrate an 8x improvement over the baseline 2Q gates with respect to speed and coherence-limited gate fidelity.

quantum computing↗

Calibrating Synchronous-Generator-Interfaced DG Models in Microgrids Using Multiple Event Data

Microgrids, consisting of distributed generators (DGs), loads, and energy storage systems, play an important role in future smart grids. In order to evaluate how microgrids operate and their dynamic response, it is necessary to develop accurate dynamic models of DGs in microgrids. This paper proposes a systematic method to calibrate synchronous-generator-interfaced DG models. Challenges associated with model validation in microgrids are analyzed. Underlying parameters are categorized into two groups, i.e., the steady-state parameters and time constants, which are estimated in two successive stages using multiple event data. This methodology ensures that the validated model with the estimated parameters are applicable for all events. A modified unscented Kalman filter (UKF) is proposed to deal with the cases in which measurement of power angle is unavailable. The effectiveness of the proposed method is validated using field test data of a 2.6 MVA diesel generator in a real microgrid.

Wang, Zhiwen↗

Clinical introduction of image lag correction for a cone beam CT system

Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the saturation handling and to 9.6 ± 12.1 HU with the saturation handling, depending on the date of the calibration. The image lag correction parameters were stable over a period of 3 months. The computational load was increased by approximately 10%, not endangering the fast in-line reconstruction. Conclusions: The lag correction was successfully implemented clinically and removed most image lag artifacts thus improving the image quality. Image lag correction parameters were stable for 3 months indicating low frequency of calibration requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Method for Producing Hierarchical and Statistically Calibrated Predictions of Nuclear Material Properties from Existing Models

Computer vision-based analysis of micrographs of nuclear materials is an emerging technique for property prediction, synthetic route identification, and other material analysis tasks. These analysis tasks play a pivotal role in many material characterization applications such as signature development for treaty verification, process optimization, etc. The backbone in many of the recent computer vision-based techniques is a deep learning model, which takes a fixed-size set of pixels and provides a class prediction for that set of pixels. For example, previous work developed a deep convolutional neural network (CNN) to predict the synthetic route from a 256 px x 256 px patch taken from a larger image of uranium ore concentrates. In this work, we present several methods for first calibrating these models in a manner that they can provide accurate probabilities of their predictions’ veracity, and several methods of combining these probabilities. Overall, the combination of these two steps into a pipeline allows for full-image and even full-sample (where a sample has many images) predictions with associated confidence values. Finally, we show that one can also use the patch predictions and confidence to produce a visualization to map predicted constituents through the image. Results and examples for predicting and mapping uranium ore concentrates’ synthetic process from imagery will be presented.

artificial intelligence↗

Calibration of higher eigenmodes of cantilevers

A method is presented for calibrating the higher eigenmodes (resonant modes) of atomic force microscopy cantilevers that can be performed prior to any tip-sample interaction. The method leverages recent efforts in accurately calibrating the first eigenmode by providing the higher-mode stiffness as a ratio to the first mode stiffness. A one-time calibration routine must be performed for every cantilever type to determine a power-law relationship between stiffness and frequency, which is then stored for future use on similar cantilevers. Then, future calibrations only require a measurement of the ratio of resonant frequencies and the stiffness of the first mode. This method is verified through stiffness measurements using three independent approaches: interferometric measurement, AC approach-curve calibration, and finite element analysis simulation. Power-law values for calibrating higher-mode stiffnesses are reported for several cantilever models. Once the higher-mode stiffnesses are known, the amplitude of each mode can also be calibrated from the thermal spectrum by application of the equipartition theorem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral Gap Filling Method Using the Spectral Information from CLARREO-Pathfinder Measured Earth-Reflected Solar Spectra to Support CPF-CERES Intercalibration

The high-accuracy Earth-reflected solar spectral radiances from CLARREO Pathfinder (CPF) will serve as in-orbit benchmark measurements for intercalibrating other satellite imagers. The CPF team is developing a state-of-the-art intercalibration method to calibrate the shortwave channel (300-5000 nm) of the CERES instrument against the CPF reference with an uncertainty of 0.3%. Because the CPF instrument only covers spectral range from 350 nm to 2300 nm, the team has developed a spectral extension method to fill in the gaps between the spectral domains of CPF and the CERES shortwave channel. The method solely relies on using the hyperspectral information from the CPF wavelengths to predict the radiances below 350 nm and above 2300 nm. To quantify the relationship between the CPF spectrum and the non-overlapping portions of the spectrum between CPF and CERES, the team has simulated a large ensemble of spectra that cover the spectral range for both CPF and CERES. A hyperspectral bidirectional reflectance model for land surface based on thousands of measured land surface reflectance has been developed. This land surface model as well as the Cox-Munk model for ocean surface are used in the spectral gap filling. Various water/ice clouds, aerosols, atmosphere profiles and surfaces were used to simulate Earth-reflected radiances from 200 nm to 15 um under different solar and sensor geometries. The targeted uncertainty for the CPF-extended broadband CERES radiances is less than 0.1%. The previously derived training spectra were updated to replace the Kurucz solar irradiance model with the TSIS-1 Hybrid Solar Reference Spectrum. The influence of the scalar assumption in radiative transfer model equations on the uncertainty in estimating the broadband radiances was also investigated.

Hyperspectral↗

Oscillation pressure device for dynamic calibration of pressure transducers

Method and apparatus for obtaining dynamic calibrations of pressure transducers. A calibration head (15), a flexible tubing (23) and a bellows (20) enclose a volume of air at atmospheric pressure with a transducer (11) to be calibrated subject to the pressure inside the volume. All of the other apparatus in the drawing apply oscillations to bellows (20) causing the volume to change thereby applying oscillating pressures to transducer (11) whereby transducer (11) can be calibrated.

Hess, Robert W.↗

Enhancing Camera Calibration for Traffic Surveillance with an Integrated Approach of Genetic Algorithm and Particle Swarm Optimization

Recent advancements in sensor technologies, coupled with signal processing and machine learning, have enabled real-time traffic control systems to effectively adapt to changing traffic conditions. Cameras, as sensors, offer a cost-effective means to determine the number, location, type, and speed of vehicles, aiding decision-making at traffic intersections. However, the effective use of cameras for traffic surveillance requires proper calibration. This paper proposes a new optimization-based method for camera calibration. In this approach, initial calibration parameters are established using the Direct Linear Transformation (DLT) method. Then, optimization algorithms are applied to further refine the calibration parameters for the correction of nonlinear lens distortions. A significant enhancement in the optimization process is achieved through the integration of the Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) into a combined Integrated GA and PSO (IGAPSO) technique. The effectiveness of this method is demonstrated through the calibration of eleven roadside cameras at three different intersections. The experimental results show that when compared to the baseline DLT method, the vehicle localization error is reduced by 22.30% with GA, 22.31% with PSO, and 25.51% with IGAPSO.

47 OTHER INSTRUMENTATION↗

Physics-constrained fault diagnosis framework for monitoring a multi-component thermal hydraulic system

A method for diagnosing faults includes receiving a system description of a thermal hydraulic system, the system description indicating a plurality of components and sensors. The method also includes constructing, based on physical conservations laws and using the system description, a plurality of physics-based models for the plurality of components, each of the plurality of physics-based models including unknown parameters. The method further includes receiving historical measurements and calibrating the physics-based models by calculating the unknown parameters of each of the physics-based models using the historical measurements to produce calibrated models. The method also includes receiving sensor measurements of the sensors, and calculating residuals corresponding to differences between measurements predicted by the plurality of calibrated models and the sensor measurements. The method also includes determining, based on the calculated residuals, a fault of a component or a sensor, and generating an alert indicating the fault.

Nguyen, Tat Nghia↗

Significantly Improving Regional Seismic Amplitude Tomography at Higher Frequencies by Determining S -Wave Bandwidth

Characterizing regional seismic signals continues to be a difficult problem due to their variability. Calibration of these signals is very important to many aspects of monitoring underground nuclear explosions, including detecting seismic signals, discriminating explosions from earthquakes, and reliably estimating magnitude and yield. Amplitude tomography, which simultaneously inverts for source, propagation, and site effects, is a leading method of calibrating these signals. A major issue in amplitude tomography is the data quality of the input amplitude measurements. Pre-event and prephase signal-to-noise ratio (SNR) tests are typically used but can frequently include bad signals and exclude good signals. The deficiencies of SNR criteria, which are demonstrated here, lead to large calibration errors. To ameliorate these issues, we introduce a semi-automated approach to assess the bandwidth of a spectrum where it behaves physically. We determine the maximum frequency (denoted as F max ) where it deviates from this behavior due to inflections at which noise or spurious signals start to bias the spectra away from the expected decay. We compare two amplitude tomography runs using the SNR and new F max criteria and show significant improvements to the stability and accuracy of the tomography output for frequency bands higher than 2 Hz by using our assessments of valid S-wave bandwidth. We compare Q estimates, P/S residuals, and some detailed results to explain the improvements. Lastly, for frequency bands higher than 4 Hz, needed for effective P/S discrimination of explosions from earthquakes, the new bandwidth criteria sufficiently fix the instabilities and errors so that the residuals and calibration terms are useful for application.

58 GEOSCIENCES↗