Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compaction technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A Data Acquisition System (DAS) for marine and ecological research from aerospace technology

The efforts of researchers at Mississippi State University to utilize space-age technology in the development of a self-contained, portable data acquisition system for use in marine and ecological research are presented. The compact, lightweight data acquisition system is capable of recording 14 variables in its present configuration and is suitable for use in either a boat, pickup truck, or light aircraft. This system will provide the acquisition of reliable data on the structure of the environment and the effect of man-made and natural activities on the observed phenomenon. Utilizing both self-contained analog recording and a telemetry transmitter for real-time digital readout and recording, the prototype system has undergone extensive testing.

Johnson, R. A.↗

Design concepts of solar thermoelectric generators in space applications

Several thermoelectric technologies have been examined as to their suitability for use in a solar thermoelectric generator (STG) as a nonpropulsive power source for space applications. The results show that of all the presently available thermoelectric technologies, i.e., lead telluride, bismuth telluride, selenide, and silicon-germanium alloys, the latter type provides the optimum STG. Detailed results are presented on the performance and configurational characteristics of various silicon-germanium alloy STGs, including the performance of such STGs as a function of time in a Mercury orbit and the orbit of Mercury around the sun. It is shown that an STG design based on the use of silicon germanium alloy thermoelectric material, using multiple high voltage thermopiles with individual solar concentrators, presents the optimum combination of technology and configuration for minimizing power source mass. Additional concepts studied and discussed are the flat plate individual thermopile type and single concentrator compact thermopile type. The STG possesses an attractive potential for this application and represents a useful addition to the family of power sources for consideration in various space applications.

Raag, V.↗

Diode-pumped laser research

The Laboratory for Oceans is currently working on the development of compact laser diode array (LD) pumped Nd:YAG lasers for use in space-based altimetry and ranging. Laser diode-array pumping technology promises to increase the electrical to optical efficiency of solid state lasers by an order of magnitude with a lifetime increase of nearly three orders of magnitude relative to today's conventional flashlamp-pumped laser systems. The small size, efficiency, and ruggedness make LD-pumped solid state lasers ideal for space based applications. In an in-house RTOP effort, a novel multiple-pass LD-pumped Nd:YAG laser amplifier was designed and tested to increase the 100 microjoule output pulse energy of the Lightwave laser oscillator. Preliminary results have yielded a round trip amplifier gain of about 15 percent using 7 microjoule LD-pump energy. As a parallel activity, funding was recently obtained to investigate the possible use of custom made fiber optic arrays to obtain an efficient optical coupling mechanism between the emitting laser diode-arrays and the target solid state laser material. Fiber optic coupling arrays would allow for the easy manipulation of the spatial emitting pattern of the diode pump sources to match either an end or side pumping laser configuration.

Ramos-Izquierdo, L.↗

3-D Flow Field Diagnostics and Validation Studies using Stereoscopic Tracking Velocimetry

The measurement of 3-D three-component velocity fields is of great importance in both ground and space experiments for understanding materials processing and fluid physics. Here, we present the investigation results of stereoscopic tracking velocimetry (STV) for measuring 3-D velocity fields. The effort includes diagnostic technology development, experimental velocity measurement, and comparison with analytical and numerical computation. The advantages of STV stems from the system simplicity for building compact hardware and in software efficiency for continual near-real-time process monitoring. It also has illumination flexibility for observing volumetric flow fields from arbitrary directions. STV is based on stereoscopic CCD observations of particles seeded in a flow. Neural networks are used for data analysis. The developed diagnostic tool is tested with a simple directional solidification apparatus using Succinonitrile. The 3-D velocity field in the liquid phase is measured and compared with results from detailed numerical computations. Our theoretical, numerical, and experimental effort has shown STV to be a viable candidate for reliably quantifying the 3-D flow field in materials processing and fluids experiments.

Cha, Soyoung Stephen↗

Adaptive Inner-Loop Rover Control

Adaptive control technology is developed for the inner-loop speed and steering control of the MAX Rover. MAX, a CMU developed rover, is a compact low-cost 4-wheel drive, 4-wheel steer (double Ackerman), high-clearance agile durable chassis, outfitted with sensors and electronics that make it ideally suited for supporting research relevant to intelligent teleoperation and as a low-cost autonomous robotic test bed and appliance. The design consists of a feedback linearization based controller with a proportional - integral (PI) feedback that is augmented by an online adaptive neural network. The adaptation law has guaranteed stability properties for safe operation. The control design is retrofit in nature so that it fits inside the outer-loop path planning algorithms. Successful hardware implementation of the controller is illustrated for several scenarios consisting of actuator failures and modeling errors in the nominal design.

Kulkarni, Nilesh↗

Taking evolutionary circuit design from experimentation to implementation: some useful techniques and a silicon demonstration

Current techniques in evolutionary synthesis of analogue and digital circuits designed at transistor level have focused on achieving the desired functional response, without paying sufficient attention to issues needed for a practical implementation of the resulting solution. No silicon fabrication of circuits with topologies designed by evolution has been done before, leaving open questions on the feasibility of the evolutionary circuit design approach, as well as on how high-performance, robust, or portable such designs could be when implemented in hardware. It is argued that moving from evolutionary 'design-for experimentation' to 'design-for-implementation' requires, beyond inclusion in the fitness function of measures indicative of circuit evaluation factors such as power consumption and robustness to temperature variations, the addition of certain evaluation techniques that are not common in conventional design. Several such techniques that were found to be useful in evolving designs for implementation are presented; some are general, and some are particular to the problem domain of transistor-level logic design, used here as a target application. The example used here is a multifunction NAND/NOR logic gate circuit, for which evolution obtained a creative circuit topology more compact than what has been achieved by multiplexing a NAND and a NOR gate. The circuit was fabricated in a 0.5 mum CMOS technology and silicon tests showed good correspondence with the simulations.

digital circuits designs↗

New Diagnostic Aids

Space Stat-30 is a compact instrument which determines the sodium and potassium levels of a blood sample in just 48 seconds. It is a spinoff from NASA technology developed to monitor health of astronauts on long-duration missions.

Source record↗

Solid-State 2-Micron Laser Transmitter Advancement for Wind and Carbon Dioxide Measurements From Ground, Airborne, and Space-Based Lidar Systems

NASA Langley Research Center has been developing 2-micron lidar technologies over a decade for wind measurements, utilizing coherent Doppler wind lidar technique and carbon dioxide measurements, utilizing Differential Absorption Lidar (DIAL) technique. Significant advancements have been made towards developing state-of-the-art technologies towards laser transmitters, detectors, and receiver systems. These efforts have led to the development of solid-state lasers with high pulse energy, tunablility, wavelength-stability, and double-pulsed operation. This paper will present a review of these technological developments along with examples of high resolution wind and high precision CO2 DIAL measurements in the atmosphere. Plans for the development of compact high power lasers for applications in airborne and future space platforms for wind and regional to global scale measurement of atmospheric CO2 will also be discussed.

Singh, Upendra N.↗

Survey of Propulsion Technologies Applicable to Cubesats

At present, no Cubesat has flown in space featuring propulsion. This was acceptable as long as CubeSats were flown mostly as university experiments. As CubeSats become of interest to other users in the government and industry communities as well, a larger range of capabilities may be required than exhibited so far, while maintaining the uniqueness of the Cubesat platform. Propulsion capability is crucial in increasing mission capabilities of future CubeSats, such as orbit change and raising, formation flying, proximity operations, fine attitude control, or drag-make-up and de-orbit. While some of these tasks may be accomplished with propellantless devices, their applications are limited, applicable mostly to a single task, and bear their own risks. In this study, a survey was conducted of propulsion technologies applicable to CubeSats. Only few off-the-shelf design solutions exist today. The survey was thus expanded to such devices as well that are under significant development, and are approaching the required design envelope for CubeSats with respect to mass, volume, and power. In some cases, such as electric propulsion devices, CubeSat architectures themselves may need to be adapted, required to feature deployable solar arrays to increase power capabilities. Given the vast scope of this survey, only thruster technologies could be surveyed. However, valves and other feed system components, as well as their integration, are equally important, but have to be left to a future survey. Three major propulsion technology areas applicable to CubeSats emerged when conducting this review: (1) Existing technologies, such as butane systems, pulsed plasma thrusters, and vacuum arc thrusters are applicable to CubeSats today with no or only minor changes, (2) New thruster technologies under significant development, such as hydrazine monopropellant systems, ion engines, or colloid thrusters could be adapted to CubeSats with some further development, especially also in other subsystem areas such as feed systems and power processing units. They will also require increased power capabilities, and (3) emerging technologies, such as micro electrospray arrays and micro cavity discharge arrays that offer even higher flexibility due to scalability for CubeSats, and enable compact integration.

micropropulsion↗

Mu-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the Mu-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the microstrip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

Micro-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the micro-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the micro strip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

Concepts for Next Generation Grating Spectrometer Imaging Atmospheric Sounders from LEO and GEO

Spaceborne infrared atmospheric sounders measure the spectrum of the upwelling radiance in the infrared with ultra-high spectral resolution. The resolution is sufficient to measure absorption features of atmospheric constituents enabling retrieval of atmospheric temperature and water vapor profiles, surface emission and atmospheric constituents. The Atmospheric Infrared Sounder (AIRS) on Aqua launched in May of 2002 was the first hyperspectral infrared sounder designed for this purpose and is still operational today. AIRS has been followed by the Infrared Atmospheric Sounding Interferometer (IASI) on MetOp A and B, and the Cross-track Infrared Sounder (CrIS) on Suomi NPP and JPSS. All instruments are operating well improving weather forecast and providing a wealth of information about the atmosphere. Additional CrIS and IASI instruments are expected to be launched providing data of this type into the late 2030’s. AIRS, CrIS and IASI are all Low Earth Orbit (LEO) instruments with nominal spatial resolutions of 14km. Future IR sounders must achieve higher spatial and temporal resolution to match improvements in forecast models and be less costly to match anticipated future budget pressures. Higher temporal resolution can be achieved in several ways including operation in Geostationary Earth Orbit (GEO) or in constellations of SmallSats and CubeSats. Higher spatial resolution can be achieved using larger format focal plane assemblies in the instruments and larger aperture telescopes. Grating spectrometers are well suited to large format FPAs by allowing a wide field of view in a compact package. Concepts for next generation grating spectrometer IR sounders that have been developed over the years at JPL are presented along with technology advancements made to enable these concepts to achieve their stated goals.

Pagano, Thomas S.↗

Wide Band Gap Radiation Detectors for Deep Space Science

Understanding how the Sun, Earth, and other objects in the solar system interact with the space radiation environment is crucial for improving activities of humans on Earth and in space. Low-power, low-noise, multidirectional robust detectors for detecting ions with a wide range of mass and energies will provide a more complete understanding of space environment physics. To meet these challenges, new ion detectors based on wide band gap (WBG) semiconductors are being developed for integration on a variety of deep space platforms. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies to enable improved instruments for space science missions. New detector technologies being developed at GRC include SiC solid-state devices as practical robust, thermally stable large area detectors for LET measurements in compact, stacked charged particle telescope. The low-noise, thermally stable nature of the WBG detectors allows a small multidirectional array of charged particle telescopes to be packed in a 6U CubeSat without active cooling for operation in lunar orbit or deep space. Using a full variety of different WBG detectors, an extremely compact instrument to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments can be realized.

ion detectors↗

Two-Phase Flow in Packed Beds, Filters and Orifices: Summary of Findings of the Packed Bed Reactor Experiment Onboard of the International Space Station

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors enables the optimization of chemical reaction rates and products that crucial in pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors and reducing space and resource requirements. Insights gained from studying and understanding such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The objective of the Packed Bed Reactor Experiment series (PBRE and PBRE-2) was to develop a fundamental understanding of the hydrodynamics of adiabatic two-phase flows through porous media in microgravity. This work provides a description of the PBRE fluid system and presents the highlights of the PBRE and PBRE-2 previously flown with different packings and operated onboard of the International Space Station Microgravity Science Glovebox (ISS-MSG). These highlights include flow patterns and two-phase pressure drop, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work also presents preliminary results from the Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) recently flown with filters and orifices, which was also operated on the ISS-MSG. The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates pertinent to the operation of these test articles. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments.

ISS↗

AGR-1, AGR-2, AGR-3/4, and AGR-5/6/7 DimensionalChange Analysis

A series of fuel irradiation experiments have been planned in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) to support the licensing and operation of the Advanced Reactor Technologies high temperature gas-cooled reactor. The advanced gas reactor (AGR) experiments are comprised of multiple independent capsules containing multiple cylindrical fuel compacts, placed inside of a graphite cylinder in ATR. The purpose of the AGR experiments is to provide data on fuel performance under irradiation, support fuel process development, qualify the fuel for normal operating conditions, provide irradiated fuel for accident testing, and support the development of fuel performance and fission product transport models. The advanced graphite creep (AGC) experiments provide irradiation creep data for design and licensing. To date, six irradiation campaigns have been completed: AGR-1 (December, 2006 – November, 2009); AGR-2 (June, 2010 – October, 2013); AGR-3/4 (December, 2011 – April, 2014); AGC-1 (September, 2009 – January, 2011); AGC-2 (April, 2011 – May, 2012); and AGC-3 (November, 2012 – April, 2014).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated Capture and Conversion of CO 2 to Methanol (ICCCM) Process Technology - CRADA 449 (Final Report)

The goal of this project is to develop a prototype system that integrates the capture and catalytic hydrogenation of CO 2 into methanol in the same solvent. Ultimately, this integrated approach could provide a technology with projected reductions to capital and operating costs by at least 20% relative to a benchmark methanol synthesis via gas-phase CO 2 hydrogenation. There were five primary objectives for the project: 1. Optimize the selections of both the catalysts and the CO 2 capture solvents to achieve high conversion (>80%) and high selectivity (>90%) toward methanol in the targeted processing ranges (100-180°C, 1-60 bar). 2. Design a reactor system that provides a fixed catalyst surface area and high-efficiency heat exchange to assure compact modular processing. 3. Build and test a reactor system and demonstrate in a bench scale continuous flow system, and use the operating data to refine the comparison to existing conversion technologies. 4. Refine techno economic (TEA) and Tech-to-Market (TTM) analyses using the experimental data obtained from the bench-scale system. 5. Use the experimental data and TEA/TTM projections to develop a conceptual design for a pre-commercial system that targets a specific market opportunity.

09 BIOMASS FUELS↗

Dismantling of the Spent Resins Hot Compaction Unit at Tihange NPP, Belgium - 19139

Design, construction and commissioning of the Spent Ion Exchange Resins Hot Compaction Unit at Tihange Nuclear Power Plant took place from 2005 till 2011. In this conditioning process, batches of radioactive resin beads were first dried to less than 4% moisture by a conical vacuum dryer. Resins were then poured in compactable 200-liter drums and super-compacted. Resulting pellets were emplaced in standard 400-liter drums, the packages qualified for final disposal in Belgium, and eventually grouted. The Belgian Waste Management Agency (ONDRAF/NIRAS) was consulted before initiating the project and issued a statement of no objection. The technology turned out to be used for the first time in the particular case of bead shaped resins (unlike powdered resins) and with a grouting requirement. Finally, commissioning tests ended in a safe and reproducible waste form, compliant with prevailing Waste Acceptance Criteria. Volume Reduction Factors of about 2 were recorded after drying and compaction. New tests were carried out to support the Qualification File of the process, which was submitted to ONDRAF/NIRAS. After performing many trials using inactive resins, the Operator dried two batches of radioactive resins and super-compacted four drums: this was a planned qualification step, aiming at the validation of process parameters. In the meantime, ONDRAF/NIRAS made parallel progress in the design of the future Near Surface Repository, where conditioned resins will be disposed of, and found some incompatibility between encapsulated dried resin beads and water intrusion hazards inside the repository. Based on the risk that dried resin beads will swell if they absorb water, causing mechanical stresses likely to compromise the integrity of the disposal site, ONDRAF/NIRAS informed Tihange NPP that the Hot Compaction Unit would not be qualified as spent resins conditioning process. Further to this irrevocable decision, the Operator undertook three actions: - The first one was the qualification and purchase of waste containers to provide additional temporary storage capacity on site for its operational spent resins; - The second one is the selection of a new spent resins conditioning process and the performance of the related qualification tests to demonstrate it meets the updated Waste Acceptance Criteria; - The last one is the dismantling of the Hot Compaction Unit to clear the space and enable the installation of new equipment. This latter task was carried out in 2018, involving decontamination and free release measurements of all the materials, a very limited fraction of it having to be further processed as radioactive waste. Nevertheless, Tihange NPP wishes to keep the super-compactor and its hydraulic unit for a possible resale or reuse for the treatment of mixed waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single Spatial-Mode Room-Temperature-Operated 3.0 to 3.4 micrometer Diode Lasers

Compact, highly efficient, 3.0 to 3.4 m light emitters are in demand for spectroscopic analysis and identification of chemical substances (including methane and formaldehyde), infrared countermeasures technologies, and development of advanced infrared scene projectors. The need for these light emitters can be currently addressed either by bulky solid-state light emitters with limited power conversion efficiency, or cooled Interband Cascade (IC) semiconductor lasers. Researchers here have developed a breakthrough approach to fabrication of diode mid-IR lasers that have several advantages over IC lasers used for the Mars 2009 mission. This breakthrough is due to a novel design utilizing the strain-engineered quantum-well (QW) active region and quinternary barriers, and due to optimization of device material composition and growth conditions (growth temperatures and rates). However, in their present form, these GaSb-based laser diodes cannot be directly used as a part of sensor systems. The device spectrum is too broad to perform spectroscopic analysis of gas species, and operating currents and voltages are too high. In the current work, the emitters were fabricated as narrow-ridge waveguide index-guided lasers rather than broad stripe-gain guided multimode Fabry-Perot (FP) lasers as was done previously. These narrow-ridge waveguide mid-IR lasers exhibit much lower power consumptions, and can operate in a single spatial mode that is necessary for demonstration of single-mode distributed feedback (DBF) devices for spectroscopic applications. These lasers will enable a new generation of compact, tunable diode laser spectrometers with lower power consumption, reduced complexity, and significantly reduced development costs. These lasers can be used for the detection of HCN, C2H2, methane, and ethane.

Frez, Clifford F.↗