Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

An Accelerated Clip Algorithm for Unstructured Meshes: A Batch-Driven Approach

The clip technique is a popular method for visualizing complex structures and phenomena within 3D unstructured meshes. Meshes can be clipped by specifying a scalar isovalue to produce an output unstructured mesh with its external surface as the isovalue. Similar to isocontouring, the clipping process relies on scalar data associated with the mesh points, including scalar data generated by implicit functions such as planes, boxes, and spheres, which facilitates the visualization of results interior to the grid. In this paper, we introduce a novel batch-driven parallel algorithm based on a sequential clip algorithm designed for high-quality results in partial volume extraction. Our algorithm comprises five passes, each progressively processing data to generate the resulting clipped unstructured mesh. The novelty lies in the use of fixed-size batches of points and cells, which enable rapid workload trimming and parallel processing, leading to a significantly improved memory footprint and run-time performance compared to the original version. On a 32-core CPU, the proposed batch-driven parallel algorithm demonstrates a run-time speed-up of up to 32.6x and a memory footprint reduction of up to 4.37x compared to the existing sequential algorithm. The software is currently available under an open-source license in the VTK visualization system.

Tsalikis, Spiros↗

Biodegradation in Soil of PLA/PBAT Blends Compatibilized with Chain Extender

This paper presents a study of biodegradation, in soil, of samples of poly(butylene adipate-co-terephthalate)(PBAT), poly(lactic acid) (PLA) and blends of these materials prepared in torque rheometer with the addition of a chain extender. Film samples of these materials were buried in soil under controlled laboratory conditions. The degraded samples were regularly taken from soil and analyzed by visual inspection, size exclusion chromatography, differential scanning calorimetry and infrared spectroscopy. Respirometry biodegradation tests were conducted to assess samples mineralization degree. Blends showed higher degree of crystallinity compared to pure polymers. Crystallinity degree enhanced during the biodegradation process in all samples, being able to causing the samples to degrade slowly. The study showed the great complexity of the biodegradation process of PLA and PBAT blends when compatibilized with a chain extender. The biodegradation rate showed different results depending on the characteristic applied to evaluate it: visual, molecular weight or mineralization. The chain extender had strong influence in PBAT and blends degradation, slowing the process as observed by the variation of molecular weight and carbonyl index. Blends showed an intermediate behavior compared to the original polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gravitoinertial force background level affects adaptation to coriolis force perturbations of reaching movements

We evaluated the combined effects on reaching movements of the transient, movement-dependent Coriolis forces and the static centrifugal forces generated in a rotating environment. Specifically, we assessed the effects of comparable Coriolis force perturbations in different static force backgrounds. Two groups of subjects made reaching movements toward a just-extinguished visual target before rotation began, during 10 rpm counterclockwise rotation, and after rotation ceased. One group was seated on the axis of rotation, the other 2.23 m away. The resultant of gravity and centrifugal force on the hand was 1.0 g for the on-center group during 10 rpm rotation, and 1.031 g for the off-center group because of the 0.25 g centrifugal force present. For both groups, rightward Coriolis forces, approximately 0.2 g peak, were generated during voluntary arm movements. The endpoints and paths of the initial per-rotation movements were deviated rightward for both groups by comparable amounts. Within 10 subsequent reaches, the on-center group regained baseline accuracy and straight-line paths; however, even after 40 movements the off-center group had not resumed baseline endpoint accuracy. Mirror-image aftereffects occurred when rotation stopped. These findings demonstrate that manual control is disrupted by transient Coriolis force perturbations and that adaptation can occur even in the absence of visual feedback. An increase, even a small one, in background force level above normal gravity does not affect the size of the reaching errors induced by Coriolis forces nor does it affect the rate of reacquiring straight reaching paths; however, it does hinder restoration of reaching accuracy.

NASA Discipline Neuroscience↗

Direct visualization of the hydration layer on alumina nanoparticles with the fluid cell STEM in situ

Rheological behavior of aqueous suspensions containing nanometer-sized powders is of relevance to many branches of industry. Unusually high viscosities observed for suspensions of nanoparticles compared to those of micron size powders cannot be explained by current viscosity models. Formation of so-called hydration layer on alumina nanoparticles in water was hypothesized, but never observed experimentally. We report here on the direct visualization of aqueous suspensions of alumina with the fluid cell in situ . We observe the hydration layer formed over the particle aggregates and show that such hydrated aggregates constitute new particle assemblies and affect the flow behavior of the suspensions. We discuss how these hydrated nanoclusters alter the effective solid content and the viscosity of nanostructured suspensions. As a result, our findings elucidate the source of high viscosity observed for nanoparticle suspensions and are of direct relevance to many industrial sectors including materials, food, cosmetics, pharmaceutical among others employing colloidal slurries with nanometer-scale particles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Heading perception in patients with advanced retinitis pigmentosa

PURPOSE: We investigated whether retinis pigmentosa (RP) patients with residual visual field of < 100 degrees could perceive heading from optic flow. METHODS: Four RP patients and four age-matched normally sighted control subjects viewed displays simulating an observer walking over a ground. In experiment 1, subjects viewed either the entire display with free fixation (full-field condition) or through an aperture with a fixation point at the center (aperture condition). In experiment 2, patients viewed displays of different durations. RESULTS: RP patients' performance was comparable to that of the age-matched control subjects: heading judgment was better in the full-field condition than in the aperture condition. Increasing display duration from 0.5 s to 1 s improved patients' heading performance, but giving them more time (3 s) to gather more visual information did not consistently further improve their performance. CONCLUSIONS: RP patients use active scanning eye movements to compensate for their visual field loss in heading perception; they might be able to gather sufficient optic flow information for heading perception in about 1 s.

Visual Perception↗

Phosphoproteomics Modifications in Women with Rheumatoid Arthritis─Application of Web-Based Software to Enhance Data Visualization

Individuals with rheumatoid arthritis (RA) are at increased risk of functional disability, cardiovascular disease, and obesity, all of which are influenced by dysregulated skeletal muscle. Here, this pilot study aims to identify phosphoproteomics changes in RA skeletal muscle and visualize modifications through development of a web-based app designed to promote user-friendly data interpretation and visualization. NanoLC–MS/MS analysis was performed on vastus lateralis biopsies from three women with RA and matched healthy controls. Differential analysis was performed using the Limma R package. Kinase substrate enrichment analysis (KSEA) predicted changes in kinase activity. RA muscle displayed 35 upregulated and 60 downregulated phosphosites, including the cytoskeletal proteins TTN (Ser33201, Ser33013, Ser20925), NEB (Ser2219, Thr254, Ser33013, Ser20925), FLNA (Ser1459), and LASP1 (Ser146). Compared to healthy controls, KSEA predicted decreased activity of several kinases in RA muscle, including PRKACA and CDKs. All such changes were visualized by use of our web-based app. Overall, phosphoproteome analysis reveals signaling alterations in RA skeletal muscle linked to cytoskeletal proteins, representing candidate disease biomarkers; these modifications can be explored through use of our web-based software.

phosphoproteomics↗

Dynamic PET simulator via tomographic emission projection for kinetic modeling and parametric image studies

Purpose: To develop and evaluate a fast and simple tool called dPETSTEP (Dynamic PET Simulator of Tracers via Emission Projection), for dynamic PET simulations as an alternative to Monte Carlo (MC), useful for educational purposes and evaluation of the effects of the clinical environment, postprocessing choices, etc., on dynamic and parametric images. Methods: The tool was developed in MATLAB using both new and previously reported modules of PETSTEP (PET Simulator of Tracers via Emission Projection). Time activity curves are generated for each voxel of the input parametric image, whereby effects of imaging system blurring, counting noise, scatters, randoms, and attenuation are simulated for each frame. Each frame is then reconstructed into images according to the user specified method, settings, and corrections. Reconstructed images were compared to MC data, and simple Gaussian noised time activity curves (GAUSS). Results: dPETSTEP was 8000 times faster than MC. Dynamic images from dPETSTEP had a root mean square error that was within 4% on average of that of MC images, whereas the GAUSS images were within 11%. The average bias in dPETSTEP and MC images was the same, while GAUSS differed by 3% points. Noise profiles in dPETSTEP images conformed well to MC images, confirmed visually by scatter plot histograms, and statistically by tumor region of interest histogram comparisons that showed no significant differences (p < 0.01). Compared to GAUSS, dPETSTEP images and noise properties agreed better with MC. Conclusions: The authors have developed a fast and easy one-stop solution for simulations of dynamic PET and parametric images, and demonstrated that it generates both images and subsequent parametric images with very similar noise properties to those of MC images, in a fraction of the time. They believe dPETSTEP to be very useful for generating fast, simple, and realistic results, however since it uses simple scatter and random models it may not be suitable for studies investigating these phenomena. dPETSTEP can be downloaded free of cost from https://github.com/CRossSchmidtlein/dPETSTEP.

60 APPLIED LIFE SCIENCES↗

Improving magnitude and phase comparison metrics for frequency response functions using cross-correlation and log-frequency shifting

This paper provides a new method for matching dominant features of Frequency Response Functions (FRFs). In particular, this paper proposes a slicing and shifting method where the key features (in this case, resonant amplitudes) of a baseline FRF are compared with a similar FRF using cross-correlation and a Log-Frequency Shift (LFS). Here, the goal is to provide an alternative to classic point-to-point methods for FRF comparison and instead to match the dominant features of two FRFs in a way similar to visual inspection. This enables existing FRF comparison metrics to then be applied with greater fidelity. Additionally, this paper introduces the Phase Similarity Metric (PSM) for comparing phases of two FRFs and illustrates the improvement of using LFS for phase comparisons as well. This paper uses a cantilever beam experiment in multiple configurations to provide a benchmark case for FRF comparison improvements.

42 ENGINEERING↗

The NAS Computational Aerosciences Archive

In order to further the state-of-the-art in computational aerosciences (CAS) technology, researchers must be able to gather and understand existing work in the field. One aspect of this information gathering is studying published work available in scientific journals and conference proceedings. However, current scientific publications are very limited in the type and amount of information that they can disseminate. Information is typically restricted to text, a few images, and a bibliography list. Additional information that might be useful to the researcher, such as additional visual results, referenced papers, and datasets, are not available. New forms of electronic publication, such as the World Wide Web (WWW), limit publication size only by available disk space and data transmission bandwidth, both of which are improving rapidly. The Numerical Aerodynamic Simulation (NAS) Systems Division at NASA Ames Research Center is in the process of creating an archive of CAS information on the WWW. This archive will be based on the large amount of information produced by researchers associated with the NAS facility. The archive will contain technical summaries and reports of research performed on NAS supercomputers, visual results (images, animations, visualization system scripts), datasets, and any other supporting meta-information. This information will be available via the WWW through the NAS homepage, located at http://www.nas.nasa.gov/, fully indexed for searching. The main components of the archive are technical summaries and reports, visual results, and datasets. Technical summaries are gathered every year by researchers who have been allotted resources on NAS supercomputers. These summaries, together with supporting visual results and references, are browsable by interested researchers. Referenced papers made available by researchers can be accessed through hypertext links. Technical reports are in-depth accounts of tools and applications research projects performed by NAS staff members and collaborators. Visual results, which may be available in the form of images, animations, and/or visualization scripts, are generated by researchers with respect to a certain research project, depicting dataset features that were determined important by the investigating researcher. For example, script files for visualization systems (e.g. FAST, PLOT3D, AVS) are provided to create visualizations on the user's local workstation to elucidate the key points of the numerical study. Users can then interact with the data starting where the investigator left off. Datasets are intended to give researchers an opportunity to understand previous work, 'mine' solutions for new information (for example, have you ever read a paper thinking "I wonder what the helicity density looks like?"), compare new techniques with older results, collaborate with remote colleagues, and perform validation. Supporting meta-information associated with the research projects is also important to provide additional context for research projects. This may include information such as the software used in the simulation (e.g. grid generators, flow solvers, visualization). In addition to serving the CAS research community, the information archive will also be helpful to students, visualization system developers and researchers, and management. Students (of any age) can use the data to study fluid dynamics, compare results from different flow solvers, learn about meshing techniques, etc., leading to better informed individuals. For these users it is particularly important that visualization be integrated into dataset archives. Visualization researchers can use dataset archives to test algorithms and techniques, leading to better visualization systems, Management can use the data to figure what is really going on behind the viewgraphs. All users will benefit from fast, easy, and convenient access to CFD datasets. The CAS information archive hopes to serve as a useful resource to those interested in computational sciences. At present, only information that may be distributed internationally is made available via the archive. Studies are underway to determine security requirements and solutions to make additional information available. By providing access to the archive via the WWW, the process of information gathering can be more productive and fruitful due to ease of access and ability to manage many different types of information. As the archive grows, additional resources from outside NAS will be added, providing a dynamic source of research results.

Miceli, Kristina D.↗

Specimen block counter-staining for localization of GUS expression in transgenic arabidopsis and tobacco

A simple counter-staining procedure has been developed for comparative beta-glucuronidase (GUS) expression and anatomical localization in transgenic herbaceous arabidopsis and tobacco. This protocol provides good anatomical visualization for monitoring chimeric gene expression at both the organ and tissue levels. It can be used with different histochemical stains and can be extended to the study of woody species. The specimens are paraffin-embedded, the block is trimmed to reveal internal structure, safranin-O staining solution is briefly applied to the surface of the block, then washed off and, after drying, a drop of immersion oil is placed on the stained surface for subsequent photographic work. This gives tissue counter-staining with good structural preservation without loss of GUS staining product; moreover, sample observation is rapid and efficient compared to existing procedures.

NASA Discipline Plant Biology↗

Application of visual psychophysics to the design of video systems for use in space

A series of two-alternative forced choice experiments was conducted to compare the sharpness of televised moving images sampled using cardinal or diagonal patterns with reference images of varying resolution. The results indicate that both image sampling and resolution orientation play an important role in determining apparent sharpness of the images. If an image has better cardinal than diagonal resolution, the apparent sharpness is significantly greater. Thus, if the polar distribution of resolution is limited by the sampling process, diagonal sampling can be expected to yield a sharper image than cardinal sampling with the same number of pixels.

Glenn, William E.↗

SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.

60 APPLIED LIFE SCIENCES↗

Potential annual daylighting performance of a high-efficiency daylight redirecting slat system

While the primary role of window attachments is often to moderate glare and solar heat gains, they are also able to provide additional daylight to interior spaces. For this purpose, a variety of daylight-redirecting window systems have been developed over the past 150 years. Fixed reflective systems (slats/light shelves) or prismatic systems that rely on total internal reflection work well under specific solar conditions, but generally sacrifice performance over a much wider range of incident solar angles and sky conditions. Dynamic systems - typically reflective slats - are more responsive to sun angles but have not been able to achieve optimal performance for glare and daylight redirection efficiency. A previous investigation into an adjustable, reflective blind concept first conceived of in the late 1970s showed promise but was not reduced to practice due to lack of adequate simulation and analysis tools. In this paper, this concept is further developed and its energy and visual comfort performance evaluated for four mid-latitude, temperate climates using ray-tracing simulation techniques. Overall, results indicate significant potential lighting energy savings when compared with conventional automated reflective blinds (2.1–4.9 kWh/(m 2 ·a), or 14%–42%, depending on climate and orientation) or, especially, manually-operated matte white venetian blinds (1.4–7.9 kWh/(m 2 ·a), or 9%–54%, depending on climate and orientation), while maintaining acceptable or better visual comfort conditions throughout the interior space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The footprints of visual attention in the Posner cueing paradigm revealed by classification images

In the Posner cueing paradigm, observers' performance in detecting a target is typically better in trials in which the target is present at the cued location than in trials in which the target appears at the uncued location. This effect can be explained in terms of a Bayesian observer where visual attention simply weights the information differently at the cued (attended) and uncued (unattended) locations without a change in the quality of processing at each location. Alternatively, it could also be explained in terms of visual attention changing the shape of the perceptual filter at the cued location. In this study, we use the classification image technique to compare the human perceptual filters at the cued and uncued locations in a contrast discrimination task. We did not find statistically significant differences between the shapes of the inferred perceptual filters across the two locations, nor did the observed differences account for the measured cueing effects in human observers. Instead, we found a difference in the magnitude of the classification images, supporting the idea that visual attention changes the weighting of information at the cued and uncued location, but does not change the quality of processing at each individual location.

Non-NASA Center↗

Evaluation of Visualization Using a 50/50 (Contrast Media/Glucose 5% Solution) Technique for Radioembolization as an Alternative to a Standard Sandwich Technique

BackgroundRadioembolization (RE) with {sup 90}yttrium ({sup 90}Y) resin microspheres generally employs a sandwich technique with separate sequential administration of contrast medium (CM), followed by vehicle (e.g., glucose 5% [G5] solution), then {sup 90}Y resin microspheres (in G5), then G5, and then CM again to avoid contact of CM and microspheres under fluoroscopic guidance. This study evaluates the visualization quality and safety of a modified sandwich technique with a 50/50-mixture of CM (Imeron 300) and G5 for administration of {sup 90}Y resin microspheres.Materials and MethodsA retrospective analysis of 81 RE procedures in patients with primary or secondary liver tumors was performed. The quality of angiographic visualization of the hepatic vessels was assessed before the first injection and immediately before the whole dose has been injected. Visualization and flow rate were graded on a 5-point scale: 1 = very good to 5 = not visible/no antegrade flow. Univariate logistic regression models and multiple linear regression models were used to evaluate the prognostic variables associated with visualization and flow scores.ResultsVisualization quality was inversely related to flow rate, the lower the flow rate the better the grade of the visualization. Visualization quality was also inversely related to body-mass-index (BMI). Performing RE with the 50/50-CM/G5 mixture resulted in a mean injection time for 1 GBq of 15 min. No clinically significant adverse events, including radiation-induced liver disease were reported.ConclusionRE with a 50/50-mixture of CM and G5 for administration of {sup 90}Y resin microspheres in a modified sandwich technique is a safe administration alternative and provides good visualization of hepatic vessels, which is inversely dependent on flow rate and BMI. Injection time was reduced compared with our experience with the standard sandwich technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding How Ligand Functionalization Influences CO2 and N2 Adsorption in a Sodalite Metal–Organic Framework

In this work, a detailed study is conducted to understand how ligand substitution influences the CO2 and N2 adsorption properties of two highly crystalline sodalite metal–organic frameworks (MOFs) known as Cu–BTT (BTT–3 = 1,3,5-benzenetristetrazolate) and Cu–BTTri (BTTri–3 = 1,3,5-benzenetristriazolate). The enthalpy of adsorption and observed adsorption capacities at a given pressure are significantly lower for Cu–BTTri compared to its tetrazole counterpart, Cu–BTT. In situ X-ray and neutron diffraction, which allow visualization of the CO2 and N2 binding sites on the internal surface of Cu–BTTri, provide insights into understanding the subtle differences. As expected, slightly elongated distances between the open Cu2+ sites and surface-bound CO2 in Cu–BTTri can be explained by the fact that the triazolate ligand is a better electron donor than the tetrazolate. The more pronounced Jahn–Teller effect in Cu–BTTri leads to weaker guest binding. The results of the aforementioned structural analysis were complemented by the prediction of the binding energies at each CO2 and N2 adsorption site by density functional theory calculations. In addition, variable temperature in situ diffraction measurements shed light on the fine structural changes of the framework and CO2 occupancies at different adsorption sites as a function of temperature. Finally, simulated breakthrough curves obtained for both sodalite MOFs demonstrate the materials’ potential performance in dry postcombustion CO2 capture. The simulation, which considers both framework uptake capacity and selectivity, predicts better separation performance for Cu–BTT. The information obtained in this work highlights how ligand substitution can influence adsorption properties and hence provides further insights into the material optimization for important separations.

adsorption capacities↗

Designing solid-liquid interphases for sodium batteries

Secondary batteries based on earth-abundant sodium metal anodes are desirable for both stationary and portable electrical energy storage. Room-temperature sodium metal batteries are impractical today because morphological instability during recharge drives rough, dendritic electrodeposition. Chemical instability of liquid electrolytes also leads to premature cell failure as a result of parasitic reactions with the anode. Here we use joint density-functional theoretical analysis to show that the surface diffusion barrier for sodium ion transport is a sensitive function of the chemistry of solid–electrolyte interphase. In particular, we find that a sodium bromide interphase presents an exceptionally low energy barrier to ion transport, comparable to that of metallic magnesium. We evaluate this prediction by means of electrochemical measurements and direct visualization studies. These experiments reveal an approximately three-fold reduction in activation energy for ion transport at a sodium bromide interphase. Direct visualization of sodium electrodeposition confirms large improvements in stability of sodium deposition at sodium bromide-rich interphases.

25 ENERGY STORAGE↗