Accelerated Aging of BKC 44306-10 Rigid Polyurethane Foam: FT-IR Spectroscopy, Dimensional Analysis, and Micro Computed Tomography

An accelerated aging study of BKC 44306-10 rigid polyurethane foam was carried out. Foam samples were aged in a nitrogen atmosphere at three different temperatures: 50 °C, 65 °C, and 80 °C. Foam samples were periodically removed from the aging canisters at 1, 3, 6, 9, 12, and 15 month intervals when FT-IR spectroscopy, dimensional analysis, and mechanical testing experiments were performed. Micro Computed Tomography imaging was also employed to study the morphology of the foams. Over the course of the aging study the foams the decreased in size by a magnitude of 0.001 inches per inch of foam. Micro CT showed the heterogeneous nature of the foam structure likely resulting from flow effects during the molding process. The effect of aging on the compression and tensile strength of the foam was minor and no cause for concern. FT-IR spectroscopy was used to follow the foam chemistry. However, it was difficult to draw definitive conclusions about the changes in chemical nature of the materials due to large variability throughout the samples.

36 MATERIALS SCIENCE↗

Bioenergy/Biotechnology projects

This report describes the progress of five different projects. The first is an enzyme immobilization study of cellulase to reduce costs of the cellulosic ethanol process. High reusability and use of substrates applicable to large scale production were focus areas for this study. The second project was the development of nanostructured catalysts for conversion of syngas to diesel. Cobalt nanowire catalyst was used in Fischer-Tropsch synthesis. The third project describes work on developing a microfluidic calorimeter to measure reaction rates of enzymes. The fourth project uses inorganic polymer binders that have the advantage of a lower carbon footprint than Portland cement while also providing excellent performance in elevated temperature, high corrosion resistance, high compressive and tensile strengths, and rapid strength gains. The fifth project investigates the potential of turbines in drop structures (such as sewer lines in tall buildings) to recover energy.

09 BIOMASS FUELS↗

EXAMINATION OF FIBERBOARD FROM SHIPPING PACKAGE 9975-01819

Upon opening package 9975-01819 following approximately 5.5 years storage in KAMS, it was observed that the fiberboard was moldy, and the total height of the fiberboard assemblies was less than normal. Observations and measurements have since been made on three subsequent occasions. The available information indicates that the package contained approximately 2.5 liters of water in excess of what would normally exist within the fiberboard. This excess moisture led to a significant loss of fiberboard strength, the subsequent compression of the bottom layers, and the growth of mold observed on both the upper and lower fiberboard assemblies. In its current state, the fiberboard from this package retains a density (related to the criticality control function) within the range measured in other packages. The amount of excess moisture present is modest throughout most of the fiberboard, and its effect on thermal conductivity should be small. The thermal conductivity should increase significantly only near the bottom of the lower fiberboard assembly where the majority of excess moisture was found. The impact absorption capability is affected, and the ability of the fiberboard to perform this function in the current state must be evaluated. The longer such a condition persists, the greater the impact on fiberboard mechanical properties.

42 ENGINEERING↗

Advancement of Commercial Intumescent Expanding Foams for Deactivation and Decommissioning in the Nuclear Sector - 20198

Florida International University (FIU), in collaboration with The Department of Energy's Office of Environmental Management (DOE-EM), Savannah River National Laboratory (SRNL), and sites across the Savannah River complex, have identified an operational requirement for a fixative technology that is intended to immobilize and/or isolate residual contamination within a 3-dimensional space. Fixation of radiological contamination can reduce worker risk and mitigate potentially hazardous conditions, however nearly every marketed contamination fixative has been found to be flammable; a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular geometry or areas that are difficult to access whilst ensuring full coverage. The technical evaluation and advancement of commercial-off-the-shelf (COTS) polyurethane foams has yielded a down-selected candidate that shows potential in meeting the requirements to support deactivation and decommissioning activities. Several performance criteria have been established and tested to progress the technology readiness level towards an active field demonstration (TRL-7). Such criteria include: mechanical failure limits, adhesive and cohesive properties, thermal/fire resilience, determining thermal behavior, ability to immobilize contamination, and a means of non-destructive evaluation of applications. The test scenario examined was targeted towards an application for decommissioning nuclear pipework, in which the down-selected polyurethane foam would act as a barrier to segregate pipework and mitigate the potential for release during cutting, packaging, and storage operations. Testing carried out at SRNL included: mechanical evaluation of tensile, compressive, and adhesion strength by dynamic mechanical analysis (DMA), as well as thermogravimetric analysis (TGA). FIU examined the foam's fixative properties by utilizing phosphorescent europium-dysprosium doped strontium aluminate powder to investigating the extent to which contamination can be immobilized. FIU has also exploited previous successes in the field of intumescent technologies to assess the down-selected foam's tolerance to an extreme fire scenario, while maintaining the ability to effectively mitigate a contamination release. Parallel to this, extensive thermal investigations were carried out to determine the upper boundary of anticipated heat generation during the curing process as heat generation has the potential to compromise rubber parts of contaminated enclosures. These investigations subsequently yielded a promising method for a non-destructive application evaluation by means of infrared thermography. Utilizing the high sensitivity of modern IR cameras, coupled with the heat generated during the curing process of the polyurethane foam, FIU has been exploring the concept of monitoring the external pipe surface for indications of an irregular or abnormal application, thus informing operational decision making. The testing carried out utilized several current 'best fit' ASTM standards, which serve as helpful guidelines for testing, however, a precise definition of the operational parameters and requirements is still necessary. With continued collaboration with SRNL, FIU aims refine said definitions and develop new standards by which this, and other decommissioning technologies, can be accredited by relevant standards based testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inference of strength and phase transition kinetics in dynamically-compressed tin

Dynamic compression experiments in condensed matter are of interest in part because they provide opportunities to examine material response under extreme conditions; however, the inference of material behavior from dynamic experiments is challenging in the presence of phase transitions exhibiting kinetic processes. Demonstrating an approach to quantitative interpretation of such dynamic experiments, here we present a Bayesian model calibration of strength and phase transformation parameters to data drawn from pulsed power and gas gun shot experiments. The posterior predictions of the Bayesian model capture the experimental measurements and account for the various uncertainties in the experimental configurations. This holistic approach to model calibration utilizing multiple types of experimental data identifies important cross correlations among kinetics, strength, and the phase boundary. Improved insight into potential sources of current model form error is provided by comparing the differences between calibrations against different subsets of the experimental data.

42 ENGINEERING↗

National Ignition Campaign (NIC) Precision Tuning Series Shock Timing Experiments

A series of precision shock timing experiments have been performed on NIF. These experiments continue to adjust the laser pulse shape and employ the adjusted cone fraction (CF) in the picket (1st 2 ns of the laser pulse) as determined from the re-emit experiment series. The NIF ignition laser pulse is precisely shaped and consists of a series of four impulses, which drive a corresponding series of shock waves of increasing strength to accelerate and compress the capsule ablator and fuel layer. To optimize the implosion, they tune not only the strength (or power) but also, to sub-nanosecond accuracy, the timing of the shock waves. In a well-tuned implosion, the shock waves work together to compress and heat the fuel. For the shock timing experiments, a re-entrant cone is inserted through both the hohlraum wall and the capsule ablator allowing a direct optical view of the propagating shocks in the capsule interior using the VISAR (Velocity Interferometer System for Any Reflector) diagnostic from outside the hohlraum. To emulate the DT ice of an ignition capsule, the inside of the cone and the capsule are filled with liquid deuterium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of mechanical testing across micro- and meso- length scales

The present report summarizes the results from a variety of tests performed across different lengths scales used to evaluate the mechanical properties of a FeCrAl C26M weld. A variety of microscale and mesoscale mechanical tests were performed to evaluate a range of properties including nanoindentation hardness, compression and shear yield strengths, tensile strengths, and elongation. Using the mesoscale tensile testing as a baseline for comparison, micropillar compression was found to be the most sensitive to microstructural changes in the weld. Nanoindentation hardness testing, being high throughput, is recommended as a first step to identify major changes in the system and if residual stress is present.

36 MATERIALS SCIENCE↗

Effect of Sample Thickness on the Tensile Strength of Small Graphite Discs

This report formally documents the completion of the Advanced Reactor Technologies (ART) Level 3 Milestone (M3TG-24OR0501054), “Continue activities related to Split Disc-DIC - complete analysis of effect of sample thickness on one fine grain graphite,” due May 31, 2024. Details within this report outline the status of activities aimed at elucidating the effect of sample thickness on the tensile strength measurement using the small-disc, split-disc testing standard in support of the US Department of Energy’s ART Graphite R&D Program. The ASTM D8289, Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite, was developed to provide an alternative means for testing tensile strength on smaller specimens, which are compatible with available irradiation capsule volumes, and other compatibility measurements. ASTM D8289 specifies that acceptable specimen diameter can range from 6 to 12.7 mm and that the maximum allowed sample thickness should be half of the diameter. However, information is limited with respect to the effect of thickness on the measured splitting tensile strength. This report documents efforts to understand the effect of sample thickness on splitting tensile strength. The work involved testing Ø12.7 mm samples of fine-grain graphites 2114 and IG-110 of different thicknesses (6.35, 5, 4, and 3 mm). The digital image correlation (DIC) method was applied to the samples, along with the ASTM D8289 Standard, to help interpret the measured results.

36 MATERIALS SCIENCE↗

Neptunium(V) adsorption to bacteria at low and high ionic strength

Np(V) is expected to be the predominant oxidation state of neptunium in aerobic natural waters. Np(V), as the NpO{sub 2}{sup +} aquo and associated complexed species, is readily soluble, weakly interacting with geologic media, and has a high redox stability under a relatively wide range of subsurface conditions. These chemical properties, along with a long half-life make it a primary element of concern regarding long-term nuclear waste storage and subsurface contaminant. The fate and transport of neptunium in the environment may be influenced by adsorption onto bacterial surfaces. The adsorption of neptunium to bacterial surfaces ties the mobility of the contaminant to the mobility of the bacterium. In this study, the adsorption of the neptunyl (NpO{sub 2}{sup +}) ion was evaluated at low ionic strength on a common soil bacterium and at high ionic strength on a halophilic bacterium isolated from a briny groundwater near the Waste Isolation Pilot Plant (WIPP) in southeast New Mexico. Adsorption experiments were performed in batch reactors as a function of pH, ionic strength, and bacterialNp mass ratio. Np(V) adsorption was modeled using a surface complexation approach with the mathematical program FITEQL to determine functional group specific binding constants. The data from acid and base titrations of the bacteria were also modeled to estimate the concentrations and deprotonation constants of discrete bacterial surface functional groups. Bacterial functional group characteristics and Np(V) adsorption behavior between the soil bacterium and the halophilic bacterium were compared. These results highlight the key similarities and differences in actinide adsorption behavior in environments of significantly different ionic strength. Similarities in adsorption behavior may be linked to similarities in the characteristics of the moieties between all bacterial cell walls. Differences in adsorption behavior may reflect differences in ionic strength effects, rather than differences in bacteria type, as the electronic double layer is compressed with increasing ionic strength. These results further highlight the importance of electrostatic interactions in the adsorption process between dissolved metals and bacterial surfaces. This work expands the understanding of actinide-bacteria adsorption phenomena to high ionic strength environmental conditions that are relevant as an aid to predicting Np(V) fate and transport behavior in areas such as the vicinity of salt-based nuclear waste repositories and high ionic-strength deep ground waters at DOE sites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

Material Property Determinations of P-Tunnel Core in Support of UNESE

A critical component of the Underground Nuclear Explosion Signatures Experiment (UNESE) program is a realistic understanding of the post-detonation processes and changes in the environment that produce observable physical and radio-chemical signatures. Rock and fracture properties are essential parameters for modeling underground nuclear explosions. In response to the need for accurate simulations of physical and radio-chemical signatures, an experimental program to determine porosity, hydrostatic and triaxial compression, and Brazilian disc tension properties of P-Tunnel core was developed and executed. This report presents the results from the experimental program. Dry porosity for P-Tunnel core ranged from 8.7%-55%. Based on hydrostatic testing, bulk modulus was shown to increase with increasing confining pressure and ranged from 1.3GPa-42.3GPa. Compressional failure envelopes, derived from wet samples, are presented for P-Tunnel lithologies. Brazilian disc tension tests were conducted on wet samples and, along with triaxial tests, are compared with dry tests from the first UNESE test bed, Barnwell. P-Tunnel core disc tension test strength varied nearly two orders of magnitude between lithologies (0.03MPa-2.77MPa). Material tested in both tension and compression is weaker wet than dry with the exception of Strongly Welded Tuff in compression which is nearly identical in compressive strength for confining pressures of OMPa and 1 OOMPa. In addition to the inherent material properties of the rocks, fractures within the samples were quantified and characterized, in order to identify differences that might be caused by the explosion-induced damage. Finally, material property determinations are linked to optical microscopy observations. The work presented here is part of a broader material characterization effort; reports are referenced within.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Elastic moduli of hexagonal diamond and cubic diamond formed under shock compression

The relative stiffnesses and strengths of hexagonal diamond and cubic diamond constitute long standing unresolved issues, because relevant experimental results are lacking. Laser interferometry was used to experimentally determine the longitudinal sound speeds and moduli in hexagonal diamond and cubic diamond formed during the shock compression of graphite. The hexagonal diamond longitudinal moduli are significantly larger than the cubic diamond longitudinal moduli, and even exceed averaged cubic diamond single crystal values. Here, the measured hexagonal diamond longitudinal moduli, combined with high-pressure bulk moduli for cubic diamond single crystals, show that shock-formed hexagonal diamond shear moduli are larger than the shear moduli for cubic diamond single crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adhesion Capabilities of Permanent Foaming Fixatives

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk; Contaminate the public and environment; Drive up costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated by Savannah River National Lab (SRNL). Adhesion testing will dictate how well PU foams will adhere and immobilize residual contamination onto a substrate. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Initial mechanical testing showed intumescent rigid PU foams were best in class (tensile, compression, TGA/DSC) Application of intumescent rigid PU foam in pipe scenario with 'contamination' showed excellent adhesion capabilities as long as foam had contact with pipe. The foam, however, was not able to penetrate 'contamination' but created pockets where the contamination interacted with the substrate. Pretreatment options of pipe were considered to produce better immobilization capabilities. Pretreatment options included COTS products like baking spray, rubber cement, and soap. Foam was still able to immobilize on a global sense, but not a local sense. Essentially acted as a mechanical plug. A tensile tester (MTS Criterion Series 43) was utilized to evaluate the tensile adhesion strength of 6 COTS PU foams. ASTM D1623: Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics. Procedures: PU foams were cured between two smooth 2'' x 2'' 304 stainless steel coupons with hinges glued on plates for gripping support. Parameters Used: Pull rate of 0.1 in/min. Calculations: Tensile adhesion strength, elongation, and ImageJ analysis of how PU foam is left on substrate. Outcome: The PU foam with the best adhesion capabilities would be downselected for further evaluation to be used as a permanent foaming fixative. The rigid PU foams had the best adhesion capabilities with the R1 foam having a max load of 236 N. One of the I-R2 samples reached almost 450 N and another sample reached 2500 N before slipping. The other intumescent foam, I-F4, had the most coverage on the stainless steel coupon's surface from the ImageJ results (61.43% surface coverage). The intumescent foam, I-R2, will be the foam of choice for future testing due its fire retardant and adhesion capabilities. Future directions: Conduct the following experiment in a pipe scenario with the down-selected PU foam. Procedures: PU foam will be cured between in a 304 stainless steel pipe (ID: 4'', OD: 4.5'', Height: 4''). Parameters Used: Compression testing results will be referenced to determine if foam's adhesion strength would be greater its compression strength as its being compressed. Calculations: Compression strength, shear stress, total time elapsed. Conduct further adhesion testing with the down-selected PU foam (I-R2) to be treated as a permanent foaming fixative (PFF). Determine the minimum contact the PFF should have with the substrate for adequate results. Evaluate if PFF's adhesion capabilities is time dependent (3.1.5 of ASTM E3911). Subject PFF to seismic stressors addressed in Safety Basis of Interim Operation documents (SBIO) to further evaluate adhesion capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In situ study on the compression deformation of MoNbTaVW high-entropy alloy

The excellent mechanical properties of high-entropy alloys (HEAs) make them promising materials for advances in science and technology. However, the underlying mechanism of plastic deformation is not well understood. In situ experiments are urgently required to provide a fundamental understanding of the plastic deformation under high pressure. We performed in situ synchrotron X-ray diffraction (XRD) experiments to study compression deformation behavior of the HEA MoNbTaVW in a radial diamond anvil cell (rDAC). Our results show that the strength and ratio of the stress-to-shear modulus values are ~1.5 and 3 times that of pure tungsten (W), respectively. MoNbTaVW showed plastic deformation above 5 GPa and displayed a much stronger texture. In this work, we found that the active dislocation behavior is mainly responsible for the high strength in MoNbTaVW under compression. This unique technique opens a new avenue to investigate the in situ mechanical properties and their mechanism in other types of HEAs.

36 MATERIALS SCIENCE↗

The granular and polymer composite nature of kerogen-rich shale

In the past decade, mechanical, physical, and chemical characterization of reservoir shale rocks, such as the Woodford shale, which is kerogen-rich shale (KRS), has moved toward micro- and nanoscale testing and analyses. Nanoindentation equipment is now widely used in many industrial and university laboratories to measure shale anisotropic Young’s moduli, kerogen stiffness, plastic yield parameters, and other isotropic and anisotropic poromechanical and viscoelastic properties. However, to date, failure analyses of KRS and the effects of organic components on the tensile strength have not been observed or measured at the micro- or nanoscales. In this study, preserved kerogen-rich Woodford shale samples manufactured in micro-beam and micro-pillar geometries were mechanically tested and brought to failure in tension and compression, respectively. These tests were conducted in situ using a nanoindenter inside a scanning electron microscope (SEM). The load versus displacement curves of prismatic micro-cantilever beams were analyzed in light of high-resolution images collected during tensile fracture initiation, propagation, and ultimately sample failure. The micro-pillar geometries were subjected to a uniaxial compressive load and were also brought to failure while capturing measurements of stress and strain. It was found that, within just a few hundred microns of the KRS microcantilever beams, both brittle and ductile failure modes were observed. In the ductile plastic domain, strain-softening and strain-hardening behaviors were identified and characterized. These were not due to confining stress variations, but due to the volume of the organic matter and the way it is interlaced with the shale minerals in and around the failure planes. The tensile strength characteristics and the large modulus of toughness of kerogen, which is a cross-linked polymer, definitely weigh heavily in our engineering field applications, such as hydraulic fracking, which is a Mode I tensile fracture opening and propagation phenomenon. This practice demands that, due to the complex composite nature of KRS, mechanical characterization be not only for unconfined compressive strength but also for unconfined tensile strength and moduli of ruptures. At the end of this study, the need for nanometer scale mechanical characterization of KRS will become apparent. Furthermore, these nano- and micro-scale shale failure tests reinforce our previous understanding of the heterogeneous composite nature of Woodford KRS and its complex behavior, as well as other source shale reservoir formations.

58 GEOSCIENCES↗

New Insights on the Mechanical Characterization of Kerogen-Rich Shale, KRS

In the past decade, mechanical, physical, and chemical characterization of reservoir shale rocks, such as the Woodford shale, which is kerogen-rich shale (KRS), has moved toward micro- and nanoscale testing and analyses. Nanoindentation equipment is now widely used in many industrial and university laboratories to measure shale anisotropic Young’s moduli, kerogen stiffness, plastic yield parameters, and other isotropic and anisotropic poromechanical and viscoelastic properties. However, to date, failure analyses of KRS and the effects of organic components on the tensile strength have not been observed or measured at the micro- or nanoscales. In this study, preserved kerogen-rich Woodford shale samples manufactured in micro-beam and micro-pillar geometries were mechanically tested and brought to failure in tension and compression, respectively. These tests were conducted in situ using a nanoindenter inside a scanning electron microscope (SEM). The load versus displacement curves of prismatic micro-cantilever beams were analyzed in light of high-resolution images collected during tensile fracture initiation, propagation, and ultimately sample failure. The micro-pillar geometries were subjected to a uniaxial compressive load and were also brought to failure while capturing measurements of stress and strain. It was found that, within just a few hundred microns of the KRS microcantilever beams, both brittle and ductile failure modes were observed. In the ductile plastic domain, strain-softening and strain-hardening behaviors were identified and characterized. These were not due to confining stress variations, but due to the volume of the organic matter and the way it is interlaced with the shale minerals in and around the failure planes. The tensile strength characteristics and the large modulus of toughness of kerogen, which is a cross-linked polymer, definitely weigh heavily in our engineering field applications, such as hydraulic fracking, which is a Mode I tensile fracture opening and propagation phenomenon. This practice demands that, due to the complex composite nature of KRS, mechanical characterization be not only for unconfined compressive strength but also for unconfined tensile strength and moduli of ruptures. At the end of this study, the need for nanometer scale mechanical characterization of KRS will become apparent. These nano- and micro-scale shale failure tests reinforce our previous understanding of the heterogeneous composite nature of Woodford KRS and its complex behavior, as well as other source shale reservoir formations.

58 GEOSCIENCES↗

Effects of build orientation and heat treatment on the evolution of microstructure and mechanical properties of alloy Mar-M-509 fabricated via laser powder bed fusion

We present the main results from an experimental investigation into the consequences of various microstructural features, created by laser powder bed fusion (LPBF) and subsequent heat treatments (HTs), in alloy Mar-M-509 on several aspects of plastic deformation including mechanical anisotropy and elongation-to-fracture (ETF). To ensure successful manufacturing of the alloy, porosity fraction and distribution are first characterized using micro X-ray computed tomography. Next, grain structure, crystallographic texture, and regions of recrystallization in the studied microstructures are measured using electron backscattered diffraction (EBSD). Lastly, chemistry, distribution, and morphological features of carbide phases are extracted using electron microscopy and X-ray diffraction. Strength in tension and compression are measured at room temperature for different initial microstructures created by variations in manufacturing conditions and sample orientations with respect to sample processing frame. While the strength of the alloy varies with sample orientation by approximately 30% in the as-built condition, the alloy is softer, more ductile, and approximately isotropic after HT. These results are discussed and critically compared with the data reported for the as-cast material. The alloy manufactured via LPBF is found to be significantly stronger and more ductile than the same alloy produced by casting. The interesting deformation behavior characteristics of the samples in different conditions are explained in terms of their microstructures. EBSD measurements reveal evolution from columnar grains along the build direction favoring a moderately strong <001> fiber texture in the as-built material to equiaxed grains favoring the {110}<001> Goss texture component after subsequent HTs. The major change in grain structure and texture is a result of recrystallization. While carbide phases precipitate primarily at dendrite and cellular interfaces in the as-built material, these phases are both intra-and inter-granular within the HT materials and coarsen with HT duration. These microstructural observations formed bases to rationalize the observed mechanical behavior of the alloy. With this being said, tailoring the alloy performance characteristics with HTs is reported on.

36 MATERIALS SCIENCE↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗