Search NASA⌕ Search

SEARCH · Search NASA

Results for “Correlation analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Shockley-Queisser analysis of the temperature-efficiency correlation of solar cells in the presence of non-radiative heat transfer

An empirical negative T cell − η correlation has been widely applied, without careful justifications, to evaluate the efficiency ( η ) increase of solar cells due to their temperature ( T cell ) decrease. Here, a framework is introduced to simultaneously compute T cell and η . This model confirms the negative T cell − η correlation if the above-bandgap absorptivity ( α I ) is not suppressed in the optimization of the sub-bandgap reflectivity ( ρ II ) or the infrared emissivity, otherwise it may suggest a positive correlation. It further gives a guideline to enhance η of silicon cells under typical conditions: every 1% increase of α I is equivalent to a 57% increase of ρ II .

14 SOLAR ENERGY↗

Uncertainty analysis of densities and isotopics: Handling correlations

This paper discusses two cases of correlated parameters in uncertainty analyses: (1) the case of measured mass, density, and volume or spatial dimension correlations; and (2) the case of measured material isotopics, where increasing one atom fraction must cause the others to decrease. In the first case, an equation is derived that has a term due to uncertain density, a term due to uncertain dimensions, and a term due to the correlation between density and dimensions. In a numerical test problem, this equation gives the same result as the standard equation that treats mass and dimensions independently. In the case of isotopics, an equation is derived relating the uncertainty due to uncertain isotopic fractions to the sensitivities to isotopic densities, which are easier to calculate. The equation is verified in a test problem. (authors)

97 MATHEMATICS AND COMPUTING↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Breast density quantification using magnetic resonance imaging (MRI) with bias field correction: A postmortem study

Purpose: Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. Methods: T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left–right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson'sr, was used to evaluate the two image segmentation algorithms and the effect of bias field. Results: The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left–right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left–right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson'sr increased from 0.86 to 0.92 with the bias field correction. Conclusions: The investigated CLIC method significantly increased the precision and accuracy of breast density quantification using breast MRI images by effectively correcting the bias field. It is expected that a fully automated computerized algorithm for breast density quantification may have great potential in clinical MRI applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Measurements of the Wake of a Sphere at Subcritical Reynolds Numbers

This work experimentally investigated the flow phenomena and vortex structures in the wake of a sphere located in a water loop at Reynolds numbers of Re = 850, 1,250, and 1,700. Velocity fields in the wake region were obtained by applying the time-resolved stereoscopic particle image velocimetry (TR-SPIV) technique. From the acquired TR-SPIV velocity vector fields, the statistical values of mean and fluctuating velocities were computed. Spectral analysis, two-point velocity–velocity cross-correlation, proper orthogonal decomposition (POD) and vortex identification analyses were also performed. The velocity fields show a recirculation region that decreases in length with an increase of Reynolds numbers. The power spectra from the spectral analysis had peaks corresponding to a Strouhal number of St = 0.2, which is a value commonly found in the literature studies of flow over a sphere. The two-point cross-correlation analysis revealed elliptical structures in the wake, with estimated integral length scales ranging between 12% and 63% of the sphere diameter. The POD analysis revealed the statistically dominant flow structures that captured the most flow kinetic energy. It is seen that the flow kinetic energy captured in the smaller scale flow structures increased as Reynolds number increased. The POD modes contained smaller structure as the Reynolds number increased and as mode order increased. In addition, spectral analysis performed on the POD temporal coefficients revealed peaks corresponding to St = 0.2, similar to the spectral analysis on the fluctuating velocity. The ability of POD to produce low-order reconstructions of the flow was also utilized to facilitate vortex identification analysis, which identified average vortex sizes of 0.41D for Re1, 0.33D for Re2, and 0.32D for Re3.

Engineering↗

Mapping Correlation of Two Point Sources in the Gamma-Ray Sky

The Fermi Gamma-Ray Space Telescope has been taking data on high energy photons or γ rays since June 11th, 2008, and people have been cataloging and profiling point sources of these γ rays ever since. After roughly one year of being in operation over 1400 sources were cataloged. Now, in 2015 we have 3033 sources cataloged. With the increasing amount of sources it’s important to think about the limitations of likelihood analysis for highly correlated sources. In this paper I will present the problems of using likelihood analysis for sources that are highly correlated as well as show under what circumstances sources can be considered highly correlated. Dark matter over densities may show up as a point source, so it is a necessary step to learn how the two signals will interact to allow for a proper search for dark matter.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey Year 1 Results: Cosmological Constraints from Cluster Abundances, Weak Lensing, and Galaxy Correlations

We present the first joint analysis of cluster abundances and auto or cross-correlations of three cosmic tracer fields: galaxy density, weak gravitational lensing shear, and cluster density split by optical richness. From a joint analysis (4×2pt+N) of cluster abundances, three cluster cross-correlations, and the auto correlations of the galaxy density measured from the first year data of the Dark Energy Survey, we obtain Ωm=0.305-0.038+0.055 and σ8=0.783-0.054+0.064. This result is consistent with constraints from the DES-Y1 galaxy clustering and weak lensing two-point correlation functions for the flat νΛCDM model. Consequently, we combine cluster abundances and all two-point correlations from across all three cosmic tracer fields (6×2pt+N) and find improved constraints on cosmological parameters as well as on the cluster observable-mass scaling relation. This analysis is an important advance in both optical cluster cosmology and multiprobe analyses of upcoming wide imaging surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Methamphetamine and HIV-Tat alter murine cardiac DNA methylation and gene expression

This study addresses the individual and combined effects of HIV-1 and methamphetamine (N-methyl-1-phenylpropan-2-amine, METH) on cardiac dysfunction in a transgenic mouse model of HIV/AIDS. METH is abused epidemically and is frequently associated with acquisition of HIV-1 infection or AIDS. We employed microarrays to identify mRNA differences in cardiac left ventricle (LV) gene expression following METH administration (10 d, 3 mg/kg/d, subcutaneously) in C57Bl/6 wild-type littermates (WT) and Tat-expressing transgenic (TG) mice. Arrays identified 880 differentially expressed genes (expression fold change > 1.5, p < 0.05) following METH exposure, Tat expression, or both. Using pathway enrichment analysis, mRNAs encoding polypeptides for calcium signaling and contractility were altered in the LV samples. Correlative DNA methylation analysis revealed significant LV DNA methylation changes following METH exposure and Tat expression. By combining these data sets, 38 gene promoters (27 related to METH, 11 related to Tat) exhibited differences by both methods of analysis. Among those, only the promoter for CACNA1C that encodes L-type calcium channel Cav1.2 displayed DNA methylation changes concordant with its gene expression change. Quantitative PCR verified that Cav1.2 LV mRNA abundance doubled following METH. Correlative immunoblots specific for Cav1.2 revealed a 3.5-fold increase in protein abundance in METH LVs. Data implicate Cav1.2 in calcium dysregulation and hypercontractility in the murine LV exposed to METH. They suggest a pathogenetic role for METH exposure to promote LV dysfunction that outweighs Tat-induced effects. - Highlights: • HIV-1 Tat and methamphetamine (METH) alter cardiac gene expression and epigenetics. • METH impacts gene expression or epigenetics more significantly than Tat expression. • METH alters cardiac mitochondrial function and calcium signaling independent of Tat. • METH alters DNA methylation, expression, and protein abundance of CACNA1C (Cav1.2).

60 APPLIED LIFE SCIENCES↗

Toxicities Affecting Quality of Life After Chemo-IMRT of Oropharyngeal Cancer: Prospective Study of Patient-Reported, Observer-Rated, and Objective Outcomes

Purpose: To test the hypothesis that intensity modulated radiation therapy (IMRT) aiming to spare the salivary glands and swallowing structures would reduce or eliminate the effects of xerostomia and dysphagia on quality of life (QOL). Methods and Materials: In this prospective, longitudinal study, 72 patients with stage III-IV oropharyngeal cancer were treated uniformly with definitive chemo-IMRT sparing the salivary glands and swallowing structures. Overall QOL was assessed by summary scores of the Head Neck QOL (HNQOL) and University of Washington QOL (UWQOL) questionnaires, as well as the HNQOL “Overall Bother” question. Quality of life, observer-rated toxicities (Common Toxicity Criteria Adverse Effects scale, version 2), and objective evaluations (videofluoroscopy assessing dysphagia and saliva flow rates assessing xerostomia) were recorded from before therapy through 2 years after therapy. Correlations between toxicities/objective evaluations and overall QOL were assessed using longitudinal repeated measures of analysis and Pearson correlations. Results: All observer-rated toxicities and QOL scores worsened 1-3 months after therapy and improved through 12 months, with minor further improvements through 24 months. At 12 months, dysphagia grades 0-1, 2, and 3, were observed in 95%, 4%, and 1% of patients, respectively. Using all posttherapy observations, observer-rated dysphagia was highly correlated with all overall QOL measures (P<.0001), whereas xerostomia and mucosal and voice toxicities were significantly correlated with some, but not all, overall QOL measures, with lower correlation coefficients than dysphagia. Late overall QOL (≥6 or ≥12 months after therapy) was primarily associated with observer-rated dysphagia, and to a lesser extent with xerostomia. Videofluoroscopy scores, but not salivary flows, were significantly correlated with some of the overall QOL measures. Conclusion: After chemo-IMRT, although late dysphagia was on average mild, it was still the major correlate of QOL. Further efforts to reduce swallowing dysfunction are likely to yield additional gains in QOL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding the Computing and Analysis Needs for Resiliency of Power Systems from Severe Weather Impacts

As the frequency and intensity of severe weather has increased, its effect on the electric grid has manifested in the form of significantly more and larger outages in the United States. This has become especially true for regions that were previously isolated from weather extremes. In this paper, we analyze the weather impacts on the electric power grid across a variety of weather conditions, draw correlations, and provide practical insights into the operational state of these systems. High resolution computational modeling of specific meteorological variables, computational approaches to solving power system models under these conditions, and the types of resiliency needs are highlighted as goal-oriented computing approaches are being built to address grid resiliency needs. An example analysis correlating outages to 1km day-ahead weather from two historical winter storms, calculated on a large cluster using a combination of interpolated and extrapolated inputs from multiple instrumented sites to workflows that produce primary meteorological outputs, is shown as initial proof of concept.

analysis↗

Axion inflation with cross-correlated axion isocurvature perturbations

We study the inflation scenarios, in the framework of superstring theory, where the inflaton is an axion producing the adiabatic curvature perturbations while there exists another light axion producing the isocurvature perturbations. We discuss how the non-trivial couplings among string axions can generically arise, and calculate the consequent cross-correlations between the adiabatic and isocurvature modes through concrete examples. Based on the Planck analysis on the generally correlated isocurvature perturbations, we show that there is a preference for the existence of the correlated isocurvature modes for the axion monodromy inflation while the natural inflation disfavors such isocurvature modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of Backing Plate and Thermal Boundary Conditions for High-Speed Friction Stir Welding of 25-mm Thick Aluminum Alloy 7175-T79

Here this study demonstrates high-speed (150 mm/min) single pass friction stir butt joining of 25 mm thick aluminum alloy 7175-T79. To understand the impact of quenching and cooling rate on process responses, joint strength, and grain size distributions across the weld thickness, we performed a series of friction stir welding (FSW) trials in air and with a trailing water spray using steel and composite backing plates (BP). Welds made in air and trailing water spray exhibit significantly different hardness distributions across the nugget, heat affected zone (HAZ), and HAZ minimum hardness as evidenced by detailed microhardness mapping. The effect of trailing water spray (TWS) on joint efficiency overshadows the influence of BP composition due to the vastly different contribution to quenching. TWS also resulted in a multifaceted effect on FSW such as lowering processing temperature, increasing X and Z forces while lowering Y force, and narrow heat affecting zone. Finally, digital image correlation (DIC)-based fracture mode analysis and grain size measurements correlate with the hardness distribution.

42 ENGINEERING↗

Stable indications of relic gravitational waves in Wilkinson Microwave Anisotropy Probe data and forecasts for the Planck mission

The relic gravitational waves are the cleanest probe of the violent times in the very early history of the Universe. They are expected to leave signatures in the observed cosmic microwave background anisotropies. We significantly improved our previous analysis [W. Zhao, D. Baskaran, and L. P. Grishchuk, Phys. Rev. D 79, 023002 (2009)] of the 5-year WMAP TT and TE data at lower multipoles l. This more general analysis returned essentially the same maximum likelihood result (unfortunately, surrounded by large remaining uncertainties): The relic gravitational waves are present and they are responsible for approximately 20% of the temperature quadrupole. We identify and discuss the reasons by which the contribution of gravitational waves can be overlooked in a data analysis. One of the reasons is a misleading reliance on data from very high multipoles l and another a too narrow understanding of the problem as the search for B modes of polarization, rather than the detection of relic gravitational waves with the help of all correlation functions. Our analysis of WMAP5 data has led to the identification of a whole family of models characterized by relatively high values of the likelihood function. Using the Fisher matrix formalism we formulated forecasts for Planck mission in the context of this family of models. We explore in detail various 'optimistic', 'pessimistic', and 'dream case' scenarios. We show that in some circumstances the B-mode detection may be very inconclusive, at the level of signal-to-noise ratio S/N=1.75, whereas a smarter data analysis can reveal the same gravitational wave signal at S/N=6.48. The final result is encouraging. Even under unfavorable conditions in terms of instrumental noises and foregrounds, the relic gravitational waves, if they are characterized by the maximum likelihood parameters that we found from WMAP5 data, will be detected by Planck at the level S/N=3.65.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Beam Analysis Of Silicon-Based Surfaces And Correlation With Surface Energy Measurements

The water affinity of Si-based surfaces is quantified by contact angle measurement and surface free energy to explain hydrophobic or hydrophilic behavior of silicone, silicates, and silicon surfaces. Surface defects such as dangling bonds, surface free energy including Lewis acid-base and Lifshitz-van der Waals components are discussed. Water nucleation and condensation is further explained by surface topography. Tapping mode atomic force microscopy (TMAFM) provides statistical analysis of the topography of these Si-based surfaces. The correlation of the above two characteristics describes the behavior of water condensation at Si-based surfaces. Surface root mean square roughness increasing from several A ring to several nm is found to provide nucleation sites that expedite water condensation visibly for silica and silicone. Hydrophilic surfaces have a condensation pattern that forms puddles of water while hydrophobic surfaces form water beads. Polymer adsorption on these surfaces alters the water affinity as well as the surface topography, and therefore controls condensation on Si-based surfaces including silicone intraocular lens (IOL). The polymer film is characterized by Rutherford backscattering spectrometry (RBS) in conjunction with 4.265 MeV {sup 12}C({alpha}, {alpha}){sup 12}C, 3.045 MeV {sup 16}O({alpha},{alpha}){sup 16}O nuclear resonance scattering (NRS), and 2.8 MeV elastic recoil detection (ERD) of hydrogen for high resolution composition and areal density measurements. The areal density of hydroxypropyl methylcellulose (HPMC) film ranges from 10{sup 18} atom/cm{sup 2} to 10{sup 19} atom/cm{sup 2} gives the silica or silicone surface a roughness of several A ring and a wavelength of 0.16{+-}0.02 {mu}m, and prevents fogging by forming a complete wetting layer during water condensation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Buckling analysis of planar compression micro-springs

Large compression deformation causes micro-springs buckling and loss of load capacity. We analyzed the impact of structural parameters and boundary conditions for planar micro-springs, and obtained the change rules for the two factors that affect buckling. A formula for critical buckling deformation of micro-springs under compressive load was derived based on elastic thin plate theory. Results from this formula were compared with finite element analysis results but these did not always correlate. Therefore, finite element analysis is necessary for micro-spring buckling analysis. We studied the variation of micro-spring critical buckling deformation caused by four structural parameters using ANSYS software under two constraint conditions. The simulation results show that when an x-direction constraint is added, the critical buckling deformation increases by 32.3-297.9%. The critical buckling deformation decreases with increase in micro-spring arc radius or section width and increases with increase in micro-spring thickness or straight beam width. We conducted experiments to confirm the simulation results, and the experimental and simulation trends were found to agree. Buckling analysis of the micro-spring establishes a theoretical foundation for optimizing micro-spring structural parameters and constraint conditions to maximize the critical buckling load.

36 MATERIALS SCIENCE↗