Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cyclic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Testing of a one-bladed 30-meter-diameter rotor on the DOE/NASA Mod-O wind turbine

Tests were conducted on the DOE/NASA Mod-O 200-kW horizontal-axis wind turbine in a one-bladed rotor configuration. The objectives of the test were to evaluate the performance, loads, and dynamic characteristics of a one-bladed rotor, and then to compare these parameters with those of an aerodynamically similar two-bladed rotor configuration. Test operations showed that this intermediate-size (15.2-m radius) one-bladed rotor configuration can be operated successfully. Test results show that the one-bladed rotor had cyclic blade loads comparable to those of a two-bladed rotor. A moderate power penalty equivalent to a reduction in windspeed of 1 m/sec occurred with the one-bladed rotor when operated at a rotor speed 50 percent higher than that of the two-bladed rotor.

Ensworth, C. B. F., III↗

Tension fatigue of glass/epoxy and graphite/epoxy tapered laminates

Symmetric tapered laminates with internally dropped plies were tested with two different layups and two materials, S2/SP250 glass/epoxy and IM6/1827I graphite/epoxy. The specimens were loaded in cyclic tension until they delaminated unstably. Each combination of material and layup had a unique failure mode. Calculated values of strain energy release rate, G, from a finite element analysis model of delamination along the taper, and for delamination from a matrix ply crack, were used with mode I fatigue characterization data from tests of the tested materials to calculate expected delamination onset loads. Calculated values were compared to the experimental results. The comparison showed that when the calculated G was chosen according to the observed delamination failures, the agreement between the calculated and measured delamination onset loads was reasonable for each combination of layup and material.

Murri, Gretchen B.↗

Tension fatigue of glass/epoxy and graphite/epoxy tapered laminates

Symmetric tapered laminates with internally dropped plies were tested with two different layups and two materials, S2/SP250 glass/epoxy and IM6/18271 graphite/epoxy. The specimens were loaded in cyclic tension until they delaminated unstably. Each combination of material and layup had a unique failure mode. Calculated values of strain energy release rate, G, from a finite element analysis model of delamination along the taper, and for delamination from a matrix ply crack, were used with mode I fatigue characterization data from tests of the tested materials to calculate expected delamination onset loads. Calculated values were compared to the experimental results. The comparison showed that when the calculated G was chosen according to the observed delamination failures, the agreement between the calculated and measured delamination onset loads was reasonable for each combination of layup and material.

Murri, Gretchen B.↗

Additive Manufacturing of Controlled Porous Elastomeric Nanocomposites for Enhanced Sensing Function

Sensors manufactured using piezoresistive elastomeric nanocomposites have a wide range of applications in many fields such as structural health monitoring, robotics, and biomedical industries. Additive manufacturing of these sensors, achieved using Direct Ink Writing (DIW), has provided numerous advantages including increased sensitivity and the fabrication of complex geometry. However, solid sensors manufactured either additively or using conventional methods, display a greater level of hysteresis, especially at strains higher than 10%, which limits their sensitivity. The solid sensors also display a greater level of piezoresistive relaxation where the resistance change with time either in a static or dynamic loading environment. Porosity can be introduced in the form of varying infill patterns and densities to reduce bulk material effects. In this paper, a lattice structure with four infill densities are investigated, and the samples are printed using a grid infill pattern. The fabricated samples are characterized using a scanning electron microscope (SEM) to validate the microstructural features and layer bonding. The pressure-sensing capability of each sensor is investigated using cyclic compression loading at various strain levels. Sensing results show that an increase in sensitivity, as well as a decrease in hysteresis with an increase in porosity, compared to solid samples (100% in-fill). The highest porosity was measured to be 62.3% with a corresponding 112% increase in the gauge factor compared to the solid bulk. These results indicate that introducing porosity using DIW is a sensible strategy to improve the piezoresistive performance of nanocomposites and to allow for the tunability of sensing capacity in pressure sensors

Sukati, Musa↗

Residual stresses in angleplied laminates and their effects on laminate behavior

Evidence of the presence of lamination residual stresses in angleplied laminates were transply cracks and warpage of unsymmetric laminates which occur prior to application of any mechanical load. Lamination residual strains were measured using the embedded strain gage technique. These strains result from the temperature differences between cure and room temperature and vary linearly within this temperature range. Lamination residual stresses were usually present in angleplied fiber composites laminates; they were also present in unidirectional hybrids and superhybrids. For specific applications, the magnitudes of lamination residual stresses were determined and evaluated relative to the anticipated applied stresses. Particular attention was given to cyclic thermal loadings in applications where the thermal cycling takes place over a wide temperature range.

Chamis, C. C.↗

Numerical Analysis of JNES Seismic Tests on Degraded Combined Piping System

Nuclear power plant safety under seismic conditions is an important consideration. The piping systems may have some defects caused by fatigue, stress corrosion cracking, etc., in aged plants. These cracks may not only affect the seismic response but also grow and break through causing loss of coolant. Therefore, an evaluation method needs to be developed to predict crack growth behavior under seismic excitation. This paper describes efforts conducted to analyze and better understand a series of degraded pipe tests under seismic loading that was conducted by Japan Nuclear Energy Safety Organization (JNES). A special 'cracked-pipe element' (CPE) concept, where the element represented the global moment-rotation response due to the crack, was developed. This approach was developed to significantly simplify the dynamic finite element analysis in fracture mechanics fields. In this paper, model validation was conducted by comparisons with a series of pipe tests with circumferential through-wall and surface cracks under different excitation conditions. These analyses showed that reasonably accurate predictions could be made using the abaqus connector element to model the complete transition of a circumferential surface crack to a through-wall crack under cyclic dynamic loading. The JNES primary loop recirculation piping test was analyzed in detail. This combined-component test had three crack locations and multiple applied simulated seismic block loadings. Comparisons were also made between the ABAQUS finite element (FE) analyses results to the measured displacements in the experiment. Good agreement was obtained, and it was confirmed that the simplified modeling is applicable to a seismic analysis for a cracked pipe on the basis of fracture mechanics. Pipe system leakage did occur in the JNES tests. The analytical predictions using the CPE approach did not predict leakage, suggesting that cyclic ductile tearing with large-scale plasticity was not the crack growth mode for the acceleration excitations considered here. Hence, the leakage was caused by low-cycle fatigue with small-scale yielding. The procedure used to make predictions of low-cycle fatigue crack growth with small-scale yielding was based on the Dowling {Delta}J procedure, which is an extension of linear-elastic fatigue crack growth methodology into the nonlinear plasticity region. The predicted moments from the CPE approach were used using a cycle-by-cycle crack growth procedure. The predictions compare quite well with the experimental measurements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ionizing Radiation from Ex Vivo Sterilization Diminishes Fatigue but Not Static Murine Vertebral Body Mechanics

For a variety of medical and scientific reasons, human bones can be exposed to ionizing radiation. At relatively high doses (30,000±5,000 Gy), ex vivo ionizing radiation is commonly used to sterilize bone allografts. However, ionizing radiation in these applications has been shown to increase risk of fracture clinically and decrease bone quality. Previously, we observed a significant decrease in compressive static strength and fatigue life of ex vivo whole bones exposed to x-ray radiation at 17,000 Gy and above; no changes in compressive mechanical properties were observed for radiation doses of 1,000 Gy and below. The gap in doses between no mechanical change (1,000 Gy) and significant mechanical degradation (17,000 Gy) is large, and it is unclear at what dose mechanical integrity begins to diminish in whole bones, and if its effects differ in response to static versus cyclic mechanical loading. This is a major clinical concern, as trabecular and cortical bone allografts are commonly used in structural, load-bearing applications. To gain insight into the effect of ionizing radiation from 1,000-17,000 Gy, we conducted an ex vivo radiation study on the static and fatigue mechanical properties of the vertebral whole bone. Our objectives were to: (1) quantify the effect of exposure to ex vivo ionizing radiation on the mechanical integrity (compressive static and fatigue) of whole bones; and (2) evaluate, if there are observed differences in mechanics, if they differ in magnitude for static versus cyclic properties. The results of this study will give insight into the need for changes in protocols for bone allograft radiation sterilization procedures.

bone mechanics↗

Performance and load data from Mod-0A and Mod-1 wind turbine generators

Experimental data, together with supporting analysis, are presented on the power conversion performance and blade loading of large, horizontal-axis wind turbines tested at electric utility sites in the U.S. Four turbine rotor configurations, from 28 to 61 meters in diameter, and data from five test sites are included. Performance data are presented in the form of graphs of power and system efficiency versus free-stream wind speed. Deviations from theoretical performance are analyzed statistically. Power conversion efficiency averaged 0.34 for all tests combined, compared with 0.31 predicted. Round blade tips appeared to improve performance significantly. Cyclic blade loads were normalized to develop load factors which can be used in the design of rotors with rigid hubs.

Spera, D. A.↗

A dislocation-based crystal viscoplasticity model with application to micro-engineered plasma-facing materials

We report materials developed with special surface architecture are shown here to be more resilient to the transient thermomechanical environments imposed by intermittent exposures to high heat flux thermal loading typical of long-pulse plasma transients. In an accompanying article, we present experimental results that show the relaxation of residual thermal stresses in micro-engineered W surfaces. A dislocation-based model is extended here within the framework of large deformation crystal plasticity. The model is applied to the deformation of single crystals, polycrystals, and micro-engineered surfaces composed of a uniform density of micro-pillars. The model is utilized to design tapered surface micro-pillar architecture, composed of a Re core and W coatings. Residual stresses generated by cyclic thermomechanical loading of these architectures show that the surface can be in a compressive stress state, following a short shakedown plasma exposure, thus mitigating surface fracture.

36 MATERIALS SCIENCE↗

Dependence of Microelastic-plastic Nonlinearity of Martensitic Stainless Steel on Fatigue Damage Accumulation

Self-organized substructural arrangements of dislocations formed in wavy slip metals during cyclic stress-induced fatigue produce substantial changes in the material microelastic-plastic nonlinearity, a quantitative measure of which is the nonlinearity parameter Beta extracted from acoustic harmonic generation measurements. The contributions to Beta from the substructural evolution of dislocations and crack growth for fatigued martensitic 410Cb stainless steel are calculated from the Cantrell model as a function of percent full fatigue life to fracture. A wave interaction factor f(sub WI) is introduced into the model to account experimentally for the relative volume of material fatigue damage included in the volume of material swept out by an interrogating acoustic wave. For cyclic stress-controlled loading at 551 MPa and f(sub WI) = 0.013 the model predicts a monotonic increase in Beta from dislocation substructures of almost 100 percent from the virgin state to roughly 95 percent full life. Negligible contributions from cracks are predicted in this range of fatigue life. However, over the last five percent of fatigue life the model predicts a rapid monotonic increase of Beta by several thousand percent that is dominated by crack growth. The theoretical predictions are in good agreement with experimental measurements of 410Cb stainless steel samples fatigued in uniaxial, stress-controlled cyclic loading at 551 MPa from zero to full tensile load with a measured f(sub WI) of 0.013.

Cantrell, John H.↗

Thermo-mechanical response predictions for metal matrix composite laminates

An analytical micromechanical model is employed for prediction of the stress-strain response of metal matrix composite laminates subjected to thermomechanical loading. The predicted behavior of laminates is based upon knowledge of the thermomechanical response of the transversely isotropic, elastic fibers and the elastic-viscoplastic, work-hardening matrix. The method is applied to study the behavior of silicon carbide/titanium metal matrix composite laminates. The response of laminates is compared with that of unidirectional lamina. The results demonstrate the effect of cooling from a stress-free temperature and the mismatch of thermal and mechanical properties of the constituent phases on the laminate's subsequent mechanical response. Typical results are presented for a variety of laminates subjected to monotonic tension, monotonic shear and cyclic tensile/compressive loadings.

Aboudi, J.↗

Thermal Loads and Cooling Design for ITER in-Port Low Field Side Reflectometer Diagnostic System

The current design for the ITER Low Field Side Reflectometer (LFSR) diagnostic system contains six circular waveguides that function as both launch and receive antennas. The front end of LFSR system, interfacing with the plasma facing DFW and its supporting diagnostic shielding Modules (DSM), is integrated into Equatorial Port Plug 11(EPP#11). In-vessel LFSR configuration is mainly divided into two sections, i.e. Front Antenna Unit (FAU) and in-vessel Transmission Line (TL) components. During plasma normal operation, the 14 MeV neutrons from D-T fusion reactions penetrate into the port plug and LFSR components. Neutronics code ATTILA is used for assessing the volumetric heating of in-vessel components. The maximum normal heat load due to radiation and the charge exchange from plasma is 0.35 MW/m 2 , which has to be applied on those surfaces affected by a viewing factor consistent with the aperture surface position and orientation. The front antenna unit (FAU) needs the active cooling to handle the radiant and nuclear heating from the plasma. Due to the specific viewing aperture layout at the front-end of in-vessel LFSR, the cooling channel design is challenging. The thermal-hydraulic iterations are performed to achieve the desirable temperature distribution of the water cooled front antenna units. The progressive ratcheting effects of the FAU subjected to cyclic thermal loading are examined by the preliminary non-linear elastic-plastic analysis.

42 ENGINEERING↗

Overcoming fatigue through compression for advanced elastocaloric cooling

Elastocaloric materials exhibit extraordinary cooling potential, but the repetition of cyclic mechanical loadings during long-term operation of cooling systems requires the refrigerant material to have long fatigue life. Here, this paper reviews the fundamental cause of fatigue from aspects of initiation and propagation of fatigue cracks in shape-memory alloys (SMAs) that are used as elastocaloric materials, and highlights recent advances in using compression to overcome fatigue by curtailing the generation of surfaces associated with crack propagation. Compression is identified as a key means to extend fatigue lifetime in engineering design of elastocaloric cooling drive mechanisms. We summarize the state-of-the-art performance of different SMAs as elastocaloric materials and discuss the influence of low cyclic strains and high resistance to transformation. We present integration of compression-based material assemblies into a cooling system prototype and optimization of the system efficiency using work recovery and related measures.

36 MATERIALS SCIENCE↗

Report on an Assessment of the Application of EPP Results from the Strain Limit Evaluation Procedure to the Prediction of Cyclic Life Based on the SMT Methodology

The goal of the proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology is to incorporate an SMT data based approach for creep-fatigue damage evaluation into the EPP methodology to avoid the separate evaluation of creep and fatigue damage and eliminate the requirement for stress classification in current methods; thus greatly simplifying evaluation of elevated temperature cyclic service. This methodology should minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed methodology and to verify the applicability of the code rules, analytical studies and evaluation of thermomechanical test results continued in FY17. This report presents the results of those studies. An EPP strain limits methodology assessment was based on recent two-bar thermal ratcheting test results on 316H stainless steel in the temperature range of 405 to 7050C. Strain range predictions from the EPP evaluation of the two-bar tests were also evaluated and compared with the experimental results. The role of sustained primary loading on cyclic life was assessed using the results of pressurized SMT data from tests on Alloy 617 at 9500C. A viscoplastic material model was used in an analytic simulation of two-bar tests to compare with EPP strain limits assessments using isochronous stress strain curves that are consistent with the viscoplastic material model. A finite element model of a prior 304H stainless steel Oak Ridge National Laboratory (ORNL) nozzle-to-sphere test was developed and used for an EPP strain limits and creep-fatigue code case damage evaluations. A theoretical treatment of a recurring issue with convergence criteria for plastic shakedown illustrated the role of computer machine precision in EPP calculations.

36 MATERIALS SCIENCE↗

Direct ink writing of shear exfoliated two-dimensional nanomaterial- elastomeric multifunctional nanocomposite

Direct ink writing (DIW) of polymer nanocomposites with high loadings of two-dimensional (2D) nanofillers (graphene and hexagonal boron nitride (hBN)) is challenging because of potential clogging, use of hazardous solvents, and agglomeration. Here, in this work, a shear exfoliation and sieving method to prepare DIW ink with high loading of nanofillers produced from low-cost bulk layered materials such as graphite and bulk hBN powder for successful DIW printing without the use of any solvents, binders, or plasticizers. The single-step exfoliation technique resulted in a composite with substantial layer reduction along the c-axis, as confirmed by SEM, TEM, XRD, and Raman analysis. Incorporating exfoliated graphene (40 wt%) increased viscosity by ∼6 orders of magnitude due to enhanced particle–matrix interactions, leading to pronounced yield stress behavior and a yield stress of approximately 1598 Pa, which enabled excellent shape retention during extrusion. Using the DIW technique, porous structures such as desalination membranes, self-sensing bone scaffolds, thermal management coating, and serpentine strain sensors were fabricated. When tested in a direct contact membrane distillation setup, the fabricated membrane demonstrated a promising permeate flux of 21.85 Lm −2 h −1 and a salt rejection of 74.3 %. The fabricated serpentine sensor exhibited stable signal variations under cyclic tensile loading, with a working range of 0–200 % strain and a maximum gauge factor of 43,735. A cell culture test using the printed bone scaffold demonstrated promising cell attachment and proliferation. The DIW printed hBN nanocomposite exhibited reversible shape change under heat, demonstrating potential 4D printing capability and efficient thermal management when exposed to high heat or flame.

Desalination↗

Non-Invasive Investigation of Bone Adaptation in Humans to Mechanical Loading

Experimental studies have identified peak cyclic forces, number of loading cycles, and loading rate as contributors to the regulation of bone metabolism. We have proposed a theoretical model that relates bone density to a mechanical stimulus derived from average daily cumulative peak cyclic 'effective' tissue stresses. In order to develop a non-invasive experimental model to test the theoretical model we need to: (1) monitor daily cumulative loading on a bone, (2) compute the internal stress state(s) resulting from the imposed loading, and (3) image volumetric bone density accurately, precisely, and reproducibly within small contiguous volumes throughout the bone. We have chosen the calcaneus (heel) as an experimental model bone site because it is loaded by ligament, tendon and joint contact forces in equilibrium with daily ground reaction forces that we can measure; it is a peripheral bone site and therefore more easily and accurately imaged with computed tomography; it is composed primarily of cancellous bone; and it is a relevant site for monitoring bone loss and adaptation in astronauts and the general population. This paper presents an overview of our recent advances in the areas of monitoring daily ground reaction forces, biomechanical modeling of the forces on the calcaneus during gait, mathematical modeling of calcaneal bone adaptation in response to cumulative daily activity, accurate and precise imaging of the calcaneus with quantitative computed tomography (QCT), and application to long duration space flight.

Whalen, R.↗

Plastic Deformation in an Amorphous Ni-P Coating

An experimental and numerical investigation of the hardness and associated plastic deformation in as-deposited and as-annealed nickel-phosphorus (Ni-P) coatings was conducted. In addition to the indentation-deformation behavior, the deformation morphology underneath the indenter was examined. The yield strength extracted from the indentation data is as high as 5.6 GPa, indicating pressure-sensitive plasticity. Results show that the as-deposited Ni-P coating was deformed appreciably through the shear-band mechanism with semi-circular and radial shear-band morphologies. From the incremental loading-unloading cyclic experiments, the phenomena on hardening and recovery, which have scarcely been recognized in amorphous materials at room temperature, were observed in the amorphous coating using instrumented nanoindentation. A numerical simulation of the interfacial indentation test between the Ni-P coating and the substrate reveals the pile-up and shear bands of the Ni-P coating that were observed during the indentation tests.

Shen, Yongfeng↗

Enhanced Fatigue Behavior in Quenched and Tempered High-Strength Steel by Means of Double Surface Treatments

The aim of this study is to maximize the fatigue life of a high-strength steel. For this purpose, two different kinds of double surface treatments were studied: shot peening plus vibratory finishing and shot peening plus grit blasting. First, a high-intensity peening treatment was applied, with the aim of inducing a deep region submitted to high compressive residual stresses, and a second surface treatment was followed, to reduce the roughness induced in the first treatment and mitigate the damage produced on the specimen surface. The use of such double treatments was demonstrated to be a good choice to achieve high surface hardening and deep compressive residual stress profiles and to minimize surface defects. The fatigue life of the steel was greatly enhanced following the application of both double surface treatments. A vibratory treatment applied for 24 h after the application of a previous shot peening treatment was able to increase the average fatigue life of the single shot-peened samples almost sevenfold, but a much greater fatigue enhancement was produced using grit blasting for only 60 s. Anyway, both second treatments are able to remove the damaged surface layer produced in the first high-intensity shot peening treatment. The obtained results also revealed that an appropriate combination of surface treatments (shot peening + secondary treatment) avoided the initiation of cracks at the surface of the specimens under cyclic bending loads. Instead, crack initiation took place beneath the compressive residual stress field, induced in alumina inclusions that acted as stress concentrators.

36 MATERIALS SCIENCE↗