Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A Hybrid Anomaly Detection Approach for Obfuscated Malware

With the rapid evolution of malicious software, cyber threats have become increasingly sophisticated, employing advanced obfuscation techniques to evade traditional detection methods. This study presents a hybrid anomaly detection approach applied to obfuscated malware. Even though there is a large body of research in this field, existing malware detection techniques have some drawbacks, such as requiring large amounts of data, trustworthiness (imprecise results) of algorithms, and advanced obfuscation. To overcome these challenges, there is a need to employ solid and efficient techniques for malware detection. This paper proposes a hybrid approach, combining an autoencoder with traditional machine-learning methods to create an efficient malware detection framework. We used the malware memory dataset (MalMemAnalysis-2022) to evaluate this framework. The results indicate that our proposed approach can detect obfuscated malware when a deep autoencoder used for feature learning is combined with logistic regression, and it is extremely fast with an Accuracy, Detection Rate (DR), Matthew Correlation Coefficient(MCC), and Statistical Parity Difference

malware detection, Hybrid Anomly Detection, Obfusc↗

Maritime Interdiction Operations Small Craft Detection

The Naval Postgraduate School has been conducting Tactical Network Topology (TNT) Maritime Interdiction Operations (MIO) experiments with Lawrence Livermore National Laboratory (LLNL) since early in 2005. In this work, we are investigating cutting edge technology to evaluate use of networks, advanced sensors and collaborative technology for globally-supported maritime interdiction operations. Some examples of our research include communications in harsh environments, between moving ships at sea; small boat drive-by radiation detection; network-centric collaboration with global partners; situational awareness; prototype sensors & biometric instruments. Since 2006, we have studied the concept of using a small vessel with fixed radiation sensors to do initial searches for illicit radioactive materials. In our work, we continue to evaluate concepts of operation for small boat monitoring. For example, in San Francisco Bay we established a simulated choke point using two RHIBs. Each RHIB had a large sodium iodide radiation sensor on board, mounted on the side nearest to the passing potential target boats. Once detections were made, notification over the network prompted a chase RHIB also equipped with a radiation sensor to further investigate the potential target. We have also used an unmanned surface vessel (USV) carrying a radiation sensor to perform the initial discovery. The USV was controlled remotely and to drive by boats in different configurations. The potential target vessels were arranged in a line, as a choke point and randomly spaced in the water. Search plans were problematic when weather, waves and drift complicated the ability to stay in one place. A further challenge is to both detect and identify the radioactive materials during the drive-by. Our radiation detection system, ARAM, Adaptable Radiation Area Monitor, is able to detect, alarm and quickly identify plausible radionuclides in real time. We have performed a number of experiments to better understand parameters of vessel speed, time, shielding, and distance in this complex three-dimensional space. At the NMIOTC in September 2009, we employed a dual detector portal followed by a chase. In this event, the challenge was to maintain communications after a lapse. When the chase went past the line-of sight reach of the Tactical Operational Center's (TOC) antenna, with interference from a fortress island in Suda Bay, Wave Relay extended the network for continued observation. Sodium iodide radiation detectors were mounted on two Hellenic Navy SEAL fast boats. After making the detection one of the portal boats maintained line-of sight while the other pursued the target vessel. Network access via Wave Relay antennas was maintained until the conclusion of the chase scenario. Progress has been made in the detection of radioactive materials in the maritime environment. The progression of the TNT MIO experiments has demonstrated the potential of the hardware to solve the problems encountered in this physically challenging environment. There continue to be interesting opportunities for research and development. These experiments provide a variety of platforms and motivated participants to perform real-world testing as solutions are made available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DyG-DPCD: A Distributed Parallel Community Detection Algorithm for Large-Scale Dynamic Graphs

Dynamic (Temporal) graphs capture the valuable evolution of real-world systems, from the continuously evolving patterns of social interactions and genetic pathways to the dynamic fluctuations of economic forces. Detecting communities for such evolving networks poses unique challenges. Detecting and analyzing the evolution of communities within dynamic graphs unlocks valuable insights into the underlying structural and temporal patterns of real-world systems. However, the sheer volume of modern graph data and the inherent complexity of the temporal dimension pose significant challenges to scalable community detection algorithms. Addressing this gap, our work explores the limited landscape of scalable distributed-memory parallel methods specifically designed for dynamic network community detection. We propose a novel parallel algorithm, DyG-DPCD (Dynamic Graph Distributed Parallel Community Detection), to detect communities in dynamic networks using the Message Passing Interface (MPI) framework. We present a vertex-centric approach, allowing us to detect communities through local optimization. Furthermore, we enhance our baseline algorithm by incorporating three heuristics, which improve the algorithm’s performance significantly while maintaining the quality of the solutions. We demonstrate the efficiency of our algorithm by experimenting on several real-world large-scale networks with hundreds of millions of edges spanning diverse domains. Notably, DyG-DPCD achieves speedups between 25× and 30× for large networks that we experimented on using NERSC compute nodes. In conclusion, our algorithm outperforms the STINGER parallel re-agglomeration algorithm by 30×.

97 MATHEMATICS AND COMPUTING↗

Vehicle detection based on visual attention mechanism and adaboost cascade classifier in intelligent transportation systems

Robust and efficient vehicle detection is an essential task in intelligent transportation systems (ITS). Unfortunately, due to a great diversity of vehicle profiles and outdoor illumination conditions, it is a challenge to detect vehicles effectively. This paper proposes a method for high-performance vehicle detection based on visual attention mechanism and AdaBoost cascade classifier. Our method constructs the structural Haar features and extracts the features of samples using structural Haar features and trains an AdaBoost cascade classifier. Then we use the visual attention mechanism to extract the target candidate region. At last, we generate detecting sub-windows in the candidate region and discriminate them with the cascade classifier to realize vehicle detection. We compare the performance of this method against two variants, one using MB–LBP features and another using Haar features. The experimental results demonstrate satisfactory performance for the proposed method in term of training speed, detecting speed and detecting accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A data-centric weak supervised learning for highway traffic incident detection

Using the data from loop detector sensors for near-real-time detection of traffic incidents on highways is crucial to averting major traffic congestion. While recent supervised machine learning methods offer solutions to incident detection by leveraging human-labeled incident data, the false alarm rate is often too high to be used in practice. Specifically, the inconsistency in the human labeling of the incidents significantly affects the performance of supervised learning models. To that end, we focus on a data-centric approach to improve the accuracy and reduce the false alarm rate of traffic incident detection on highways. We develop a weak supervised learning workflow to generate high-quality training labels for the incident data without the ground truth labels, and we use those generated labels in the supervised learning setup for final detection. This approach comprises three stages. First, we introduce a data preprocessing and curation pipeline that processes traffic sensor data to generate high-quality training data through leveraging labeling functions, which can be domain knowledge-related or simple heuristic rules. Second, we evaluate the training data generated by weak supervision using three supervised learning models-random forest, k-nearest neighbors, and a support vector machine ensemble-and long short-term memory classifiers. The results show that the accuracy of all of the models improves significantly after using the training data generated by weak supervision. Third, we develop an online real-time incident detection approach that leverages the model ensemble and the uncertainty quantification while detecting incidents. Finally, we show that our proposed weak supervised learning workflow achieves a high incident detection rate (0.90) and low false alarm rate (0.08).

97 MATHEMATICS AND COMPUTING↗

Spatiotemporal features of traffic help reduce automatic accident detection time

Quick and reliable automatic detection of traffic accidents is of paramount importance to save human lives in transportation systems. However, automatically detecting when accidents occur has proven challenging, and minimizing the time to detect accidents (TTDA) by using traditional features in machine learning (ML) classifiers has plateaued. We hypothesize that accidents affect traffic farther from the accident location than previously reported. Therefore, leveraging traffic signatures from neighboring sensors that are adjacent to accidents should help improve their detection. We confirm this hypothesis by using verified ground-truth accident data, traffic data from radar detection system sensors, and light and weather conditions and show that we can minimize the TTDA while maximizing classification performance by considering spatiotemporal features of traffic. Specifically, we compare the performance of different ML classifiers (i.e, logistic regression, random forest, and XGBoost) when controlling for different numbers of neighboring sensors and TTDA horizons. We use data from interstates 75 and 24 in the metropolitan area that surrounds Chattanooga, TN. Our results show that the XGBoost classifier produces the best results by detecting accidents as quickly as 1.0 min after their occurrence with an area under the receiver operating characteristic curve of up to 83% and an average precision of up to 49%. We describe limitations, open challenges, and how the proposed framework can be used for quicker operational accident detection.

33 ADVANCED PROPULSION SYSTEMS↗

Sensitive and selective colorimetric detection of Pb2+ by silver nanoparticles synthesized from Aconitum violaceum plant leaf extract

Highlights: • A new colorimetric sensor for the detection of Pb{sup 2+} using Aconitum violaceum leaf extract synthesized AgNPs was developed. • The color and spectral variations of the assay was easily detected by naked eye or spectrophotometer. • The bio-functionalized AgNPs were capable of detecting Pb{sup 2+} in the range of 0.5 × 10{sup −7}–2.5 × 10{sup −5} M with good linearity. • The proposed method showed high specificity and good recoveries for Pb{sup 2+} in river water. - Abstract: In this work, we propose a simple and cost effective colorimetric method for the detection of Pb{sup 2+} using silver nanoparticles (AgNPs) prepared from the leaf extract of Aconitum violaceum. Due to the presence of significant amount of polyphenols in the extract, the AgNPs were successfully synthesized and were then characterized by UV–vis spectroscopy, Fourier transform infrared spectroscopy (FT-IR), X-Ray diffraction (XRD) and transmission electron microscopy (TEM). The as prepared AgNPs were employed as colorimetric probes for the detection of Pb{sup 2+}. In the presence of Pb{sup 2+}, the biosynthesized AgNPs showed a color transformation from yellow to red, which was readily determined by UV–vis spectroscopy. The novel sensor exhibited good linearity for the detection of Pb{sup 2+} in the concentration range of 0.5 - 25 μM (R{sup 2 }= 0.996) with a detection limit (LOD) of 0.1 μM. Also, this sensing system presented a highly selective response for Pb{sup 2+} determination.

54 ENVIRONMENTAL SCIENCES↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dispersive Fourier transformation for megahertz detection of coherent stokes and anti-stokes Raman spectra

In many fields of study, from coherent Raman microscopy on living cells to time-resolved coherent Raman spectroscopy of gas-phase turbulence and combustion reaction dynamics, the need for the capability to time-resolve fast dynamical and nonrepetitive processes has led to the continued development of high-speed coherent Raman methods and new high-repetition rate laser sources, such as pulse-burst laser systems. However, much less emphasis has been placed on our ability to detect shot to shot coherent Raman spectra at equivalently high scan rates, across the kilohertz to megahertz regime. This is beyond the capability of modern scientific charge coupled device (CCD) cameras, for instance, as would be employed with a Czerny-Turner type spectrograph. In this paper, as an alternative detection strategy with megahertz spectral detection rate, we demonstrate dispersive Fourier transformation detection of pulsed (~90 ps) coherent Raman signals in the time-domain. Instead of reading the frequency domain signal out using a spectrometer and CCD, the signal is transformed into a time-domain waveform through dispersive Fourier transformation in a long single-mode fiber and read-out with a fast sampling photodiode and oscilloscope. Molecular O- and S-branch rotational sideband spectra from both N 2 and H 2 were acquired employing this scheme, and the waveform is fitted to show highly quantitative agreement with a molecular model. Finally, the total detection time for the rotational spectrum was 20 ns, indicating an upper limit to the detection frequency of ~50 MHz, significantly faster than any other reported spectrally-resolved coherent anti-Stokes Raman detection strategy to date.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Potentiometric Sensors Based on Surface Molecular Imprinting: Detection of Cancer Biomarkers and Viruses

The continuing discovery of cancer biomarkers necessitates improved methods for their detection. Molecular imprinting using artificial materials provides an alternative to the detection of a wide range of substances. We applied surface molecular imprinting using self-assembled monolayers to design sensing elements for the detection of cancer biomarkers and other proteins. These elements consist of a gold-coated silicon chip onto which hydroxyl-terminated alkanethiol molecules and template biomolecule are co-adsorbed, where the thiol molecules are chemically bound to the metal substrate and self-assembled into highly ordered monolayers, the biomolecules can be removed, creating the foot-print cavities in the monolayer matrix for this kind of template molecules. Re-adsorption of the biomolecules to the sensing chip changes its potential, which can be measured potentiometrically. We applied this method to the detection of carcinoembryonic antigen (CEA) in both solutions of purified CEA and in the culture medium of a CEA-producing human colon cancer cell line. The CEA assay, validated also against a standard immunoassay, was both sensitive (detection range 2.5-250 ng/mL) and specific (no cross-reactivity with hemoglobin; no response by a non-imprinted sensor). Similar results were obtained for human amylase. In addition, we detected virions of poliovirus in a specific manner (no cross-reactivity to adenovirus, no response by a non-imprinted sensor). Our findings demonstrate the application of the principles of molecular imprinting to the development of a new method for the detection of protein cancer biomarkers and to protein-based macromolecular structures such as the capsid of a virion. This approach has the potential of generating a general assay methodology that could be highly sensitive, specific, simple and likely inexpensive.

59 BASIC BIOLOGICAL SCIENCES↗

A Quantum Dot Nanobiosensor for Rapid Detection of Botulinum Neurotoxin Serotype E

Botulinum neurotoxins (BoNTs) are potent toxins produced by Clostridium bacteria that are responsible for the illness botulism and are listed as bioterrorism agents. BoNT serotype E (BoNT/E) is one of four BoNT serotypes that cause human botulism and is the second most frequent cause of foodborne botulism. Rapid detection and discrimination of BoNT serotypes implicated in human disease are critical for ensuring timely treatment of patients and identifying sources of toxins, but there have been few reported detection methods for BoNT/E and even fewer methods usable for BoNT serotyping. We report a nanobiosensor based on Forster resonance energy transfer (FRET) between semiconductor nanocrystals (quantum dots, QDs) and dark quencher-labeled peptide probes to detect biologically active BoNT/E in aqueous media. The peptide probes contain a specific cleavage site for active BoNT/E. QD photoluminescence, which changes intensity due to FRET when the peptide probe is cleaved, was used to indicate toxin presence and quantity. The detection of a BoNT/E light chain (LcE) and holotoxin was observed within 3 h. The limits of detection were 0.02 and 2 ng/mL for LcE and holotoxin, respectively. The nanobiosensor shows good specificity toward the target in tests with nontarget BoNT serotypes. The high sensitivity, simple operation, short detection time, and ability to be used in parallel with probes developed for other BoNT serotypes indicate that the nanobiosensor will be useful for rapid BoNT/E detection and serotype discrimination in food analysis.

botulinum neurotoxin E↗

Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

methamphetamine, cocaine, heroin, fentanyl, atmosp↗

Dark Matter (mostly Direct) Detection

After briefly summarizing the motivations for the {Lambda}-CDM model, I will argue rather provocatively that the many candidates already reported by indirect detection experiments are a strong indication that it is nearly impossible to distinguish a WIMP annihilation signal from astrophysical background using the indirect detection method. This structural uncertainty argues strongly in favor of direct detection of WIMP interactions in the controlled environment of the laboratory and I will describe the main strategies developed to detect WIMPs using the direct detection technique in underground sites, protected from the cosmic-ray induced background. I will show that most of the present experimental efforts is now focused on three identification techniques of nuclear recoils, i.e. charge-phonon, light-phonon and charge-scintillation simultaneous detection. Finally, since direct detection has also its own candidate, I will comment on the DAMA annual modulation candidate, and on the lessons that can be learned from the long controversy over this result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of concealed and buried chemicals by using multifrequency excitations

In this paper, we present a new type of concealed and buried chemical detection system by stimulating and enhancing spectroscopic signatures with multifrequency excitations, which includes a low frequency gradient dc electric field, a high frequency microwave field, and higher frequency infrared (IR) radiations. Each excitation frequency plays a unique role. The microwave, which can penetrate into the underground and/or pass through the dielectric covers with low attenuation, could effectively transform its energy into the concealed and buried chemicals and increases its evaporation rate from the sample source. Subsequently, a gradient dc electric field, generated by a Van De Graaff generator, not only serves as a vapor accelerator for efficiently expediting the transportation process of the vapor release from the concealed and buried chemicals but also acts as a vapor concentrator for increasing the chemical concentrations in the detection area, which enables the trace level chemical detection. Finally, the stimulated and enhanced vapors on the surface are detected by the IR spectroscopic fingerprints. Our theoretical and experimental results demonstrate that more than sixfold increase in detection signal can be achieved by using this proposed technology. The proposed technology can also be used for standoff detection of concealed and buried chemicals by adding the remote IR and/or thermal spectroscopic and imaging detection systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum-enhanced metrology based on Fabry-Perot interferometer by squeezed vacuum and non-Gaussian detection

We have investigated the transmission spectra of a Fabry-Perot interferometer (FPI) with squeezed vacuum state injection and non-Gaussian detection, including photon number resolving detection and parity detection. In order to show the suitability of the system, parallel studies were made of the performance of two other light sources: coherent state of light and Fock state of light either with classical mean intensity detection or with non-Gaussian detection. This shows that by using the squeezed vacuum state and non-Gaussian detection simultaneously, the resolution of the FPI can go far beyond the cavity standard bandwidth limit based on the current techniques. The sensitivity of the scheme has also been explored and it shows that the minimum detectable sensitivity is better than that of the other schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Induction-detection electron spin resonance with spin sensitivity of a few tens of spins

Electron spin resonance (ESR) is a spectroscopic method that addresses electrons in paramagnetic materials directly through their spin properties. ESR has many applications, ranging from semiconductor characterization to structural biology and even quantum computing. Although it is very powerful and informative, ESR traditionally suffers from low sensitivity, requiring many millions of spins to get a measureable signal with commercial systems using the Faraday induction-detection principle. In view of this disadvantage, significant efforts were made recently to develop alternative detection schemes based, for example, on force, optical, or electrical detection of spins, all of which can reach single electron spin sensitivity. This sensitivity, however, comes at the price of limited applicability and usefulness with regard to real scientific and technological issues facing modern ESR which are currently dealt with conventional induction-detection ESR on a daily basis. Here, we present the most sensitive experimental induction-detection ESR setup and results ever recorded that can detect the signal from just a few tens of spins. They were achieved thanks to the development of an ultra-miniature micrometer-sized microwave resonator that was operated at ∼34 GHz at cryogenic temperatures in conjunction with a unique cryogenically cooled low noise amplifier. The test sample used was isotopically enriched phosphorus-doped silicon, which is of significant relevance to spin-based quantum computing. The sensitivity was experimentally verified with the aid of a unique high-resolution ESR imaging approach. These results represent a paradigm shift with respect to the capabilities and possible applications of induction-detection-based ESR spectroscopy and imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reinforcement Learning for Anomaly Detection in Nuclear Power Plant Operation and Maintenance

In nuclear power plants (NPPs), timely identification of sensor and human errors is critical to ensure safe and efficient plant operations. Anomaly detection models can be employed for this task. However, traditional anomaly detection approaches may have high dependency on labeled datasets and struggle with adaptability in complex, dynamic environments. Reinforcement learning (RL) has demonstrated significant potential in fault diagnosis and anomaly detection; however, its application to anomaly detection in NPPs remains a relatively underexplored research direction. Hence, to address this gap, in this study, we present a novel physics-informed reinforcement learning model, PIRL-AD: Physics-Informed Reinforcement Learning for Anomaly Detection, that integrates domain knowledge from calorimetric equations into the RL framework for enhanced sensor and human error anomaly detection. We evaluate the performance of PIRL-AD against a non-physics informed RL benchmark and a support vector machine (SVM) on data collected from a forced flow loop testbed. Experimental results suggest that PIRL-AD outperforms other baselines on a range of anomalous datasets that include both sensor and human-induced anomalies across key performance metrics, statistically outperforming the RL and SVM benchmarks with respect to geometric mean (respectively, 92.96% vs. 91.06% vs. 83.01%) and F1-score (respectively, 89.23% vs. 86.98% vs. 77.01%). Furthermore, the findings suggest the potential of physics-integrated reinforcement learning models for enhanced anomaly detection performance in NPPs.

Reinforcement learning↗

DETECTION RATES FOR SURVEYS FOR FAST TRANSIENTS WITH NEXT GENERATION RADIO ARRAYS

We relate the underlying properties of a population of fast radio-emitting transient events to its expected detection rate in a survey of finite sensitivity. The distribution of the distances of the detected events is determined in terms of the population luminosity distribution and survey parameters, for both extragalactic and Galactic populations. The detection rate as a function of Galactic position is examined to identify regions that optimize survey efficiency in a survey whose field of view is limited. The impact of temporal smearing caused by scattering in the interstellar medium has a large and direction-dependent bearing on the detection of impulsive signals, and we present a model for the effects of scattering on the detection rate. We show that the detection rate scales as {Omega}S{sup -3/2+{delta}}{sub 0}, where {Omega} is the field of view, S{sub 0} is the minimum detectable flux density, and 0 < {delta} {<=} 3/2 for a survey of Galactic transients in which interstellar scattering or the finite volume of the Galaxy is important. We derive formal conditions on the optimal survey strategy to adopt under different circumstances for fast transient surveys on next generation large-element, wide-field arrays, such as ASKAP, LOFAR, the MWA, and the SKA, and show how interstellar scattering and the finite spatial extent of a Galactic population modify the choice of optimal strategy.

79 ASTRONOMY AND ASTROPHYSICS↗