Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic Electrochemical Immunoassays with Quantum Dot Labels for Detection of Phosphorylated Acetylcholinesterase in Plasma

A new magnetic electrochemical immunoassay has been developed as a tool for biomonitoring exposures to organophosphate (OP) compounds, e.g., insecticides and chemical nerve agents, by directly detecting organophosphorylated acetylcholinesterase (OP-AChE). This immunoassay uniquely incorporates highly efficient magnetic separation with ultrasensitive square wave voltammetry (SWV) analysis with quantum dots (QDs) as labels. A pair of antibodies was used to achieve the specific recognition of OP-AChE that was prepared with paraoxon as an OP model agent. Antiphosphoserine polyclonal antibodies were anchored on amorphous magnetic particles preferably chosen to capture OP-AChE from the sample matrixes by binding their phosphoserine moieties that were exposed through unfolding the protein adducts. This was validated by electrochemical examinations and enzyme-linked immunosorbent assays. Furthermore, antihuman AChE monoclonal antibodies were labeled with cadmium-source QDs to selectively recognize the captured OP-AChE, as characterized by transmission electron microscopy. The subsequent electrochemical SWV analysis of the cadmium component released by acid from the coupled QDs was conducted on disposable screen-printed electrodes. Experimental results indicated that the SWV-based immunoassays could yield a linear response over a broad concentration range of 0.3-300 ng/mL OP-AChE in human plasma with a detection limit of 0.15 ng/mL. Such a novel electrochemical immunoassay holds great promise as a simple, selective, sensitive, and field-deployable tool for the effective biomonitoring and diagnosis of potential exposures to nerve agents and pesticides.

59 BASIC BIOLOGICAL SCIENCES↗

Search for TiO and Optical Nightside Emission from the Exoplanet WASP-33b

With a temperature akin to an M dwarf, WASP-33b is among the hottest Jupiters known, making it an ideal target for high-resolution optical spectroscopy. By analyzing both transmission and emission spectra, we aim to substantiate previous reports of atmospheric TiO and a thermal inversion within the planet’s atmosphere. We observed two transits and six arcs of the phase curve with the Echelle SpectroPolarimetric Device for the Observation of Stars (ESPaDOnS) on the Canada–France–Hawaii Telescope and High Resolution Echelle Spectrometer (HIRES) on the Keck telescope, which provide high spectral resolution and ample wavelength coverage. We employ the Doppler cross-correlation technique to search for the molecular signatures of TiO and H{sub 2}O in these spectra, using models based on the TiO line list of Plez. Though we cannot exclude line-list-dependent effects, our data do not corroborate previous indications of a thermal inversion. Instead we place a 3σ upper limit of 10{sup −9} on the volume mixing ratio of TiO for the T–P profile we consider. While we are unable to constrain the volume mixing ratio of water, our strongest constraint on TiO comes from dayside emission spectra. This apparent absence of a stratosphere sits in stark contrast to previous observations of WASP-33b as well as theoretical predictions for the atmospheres of highly irradiated planets. The discrepancy could be due to variances between line lists, and we stress that detection limits are only as good as the line list employed, and are only valid for the specific T–P profile considered due to the strong degeneracy between lapse rate (dT/dlogP) and molecular abundance.

79 ASTRONOMY AND ASTROPHYSICS↗

The Sample at Mars Analysis (SAM) Detections of CO2 and CO in Sedimentary Material from Gale Crater, Mars: Implications for the Presence of Organic Carbon and Microbial Habitability on Mars

Sedimentary rock samples heated to 860 C in the SAM instrument evolved CO2 and CO indicating the presence of organic-carbon(C) in Gale Crater materials. Martian or exogenous (meteoritic, interplanetary dust) CO2 and CO could be derived from combustion of simple organics (less than 300 C), complex refractory organics/amorphous carbon (300-600 C), and/or magmatic carbon (greater than 600 C) as result of thermal decomposition of Gale Crater perchlorates, and sulfates present that produce O2. Oxidized organic compounds could also evolve CO2 and CO over broad temperature range (150 to 800 C) and such organics are expected on Mars via exogenous sources. Alternatively, organic-C could also have been oxidized to carboxylic acids [e.g, mellitic acid (RCOOH), acetate (CH3CO2(-)), and oxalates ((2)C2O4(-))] by oxidative radiolytic weathering, or other oxidation processes. The presence of oxidized organics is consistent with the limited detection of reduced organic-C phases by the SAM-gas chromatography. Organic-C content as determined by CO2 and CO contents could range between 800 and 2400 ppm C indicating that substantial organic-C component is present in Gale Crater. There are contributions from SAM background however, even in worse case scenarios, this would only account for as much as half of the detected CO2 and CO. Nevertheless, if organic-C levels were assumed to have existed in a reduced form on ancient Mars and this was bioavailable C, then less than 1% of C in Gale Crater sediments could have supported an exclusively heterotrophic microbial population of 1 x 10(exp 5) cells/g sediment (assumes 9 x 10(exp -7) microgram/cell and 0.5 micrograms C/microgram cell). While other essential nutrients (e.g., S and P) could be limiting, organic-C contents, may have been sufficient to support limited heterotrophic microbial populations on ancient Mars.

Sutter, Brad↗

Propidium Monoazide (PMAxx)-Recombinase Polymerase Amplification Exo (RPA Exo) Assay for Rapid Detection of Burkholderia cepacia Complex in Chlorhexidine Gluconate (CHX) and Benzalkonium Chloride (BZK) Solutions

Both sterile and non-sterile pharmaceutical products, which include antiseptics, have been recalled due to Burkholderia cepacia complex (BCC) contamination. Therefore, minimizing the frequency of outbreaks may be conducive to the development of a quick and sensitive approach that can distinguish between live and dead loads of BCC. We have assessed an exo probe-based recombinase polymerase amplification (RPA) with 10 µM propidium monoazide (PMAxx) for selective detection of live/dead BCC cells in various concentrations of antiseptics (i.e., chlorhexidine gluconate (CHX) and benzalkonium chloride (BZK) solutions) after 24 h. The optimized assay conducted using a set of primer–probes targeting gbpT was performed at 40 °C for 20 min and shows a detection limit of 10 pg/µL of genomic DNA from B. cenocepacia J2315, equivalent to 10 4 colony-forming units (CFU/mL). The specificity of a newly designed primer and probe was 80% (20 negatives out of 25). The readings for total cells (i.e., without PMAxx) from 200 µg/mL CHX using PMAxx-RPA exo assay was 310 relative fluorescence units (RFU), compared to 129 RFU with PMAxx (i.e., live cells). Furthermore, in 50–500 µg/mL BZK-treated cells, a difference in the detection rate was observed between the PMAxx-RPA exo assay in live cells (130.4–459.3 RFU) and total cells (207.82–684.5 RFU). This study shows that the PMAxx-RPA exo assay appears to be a valid tool for the simple, rapid and presumptive detection of live BCC cells in antiseptics, thereby ensuring the quality and safety of pharmaceutical products.

59 BASIC BIOLOGICAL SCIENCES↗

One-step electrochemical deposition of a graphene-ZrO 2 nanocomposite: Preparation, characterization and application for detection of organophosphorus agents

This paper described the preparation, characterization, and electrochemical properties of a graphene-ZrO 2 nanocomposite (GZN) and its application for both the enrichment and detection of methyl parathion (MP). GZN was fabricated using electrochemical deposition and characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), which showed the successful formation of nanocomposites. Due to the strong affinity to the phosphoric group and the fast electron-transfer kinetics of GZN, both the extraction and electrochemical detection of organophosphorus (OP) agents at the same GZN modified electrochemical sensor was possible. The combination of solid-phase extraction and stripping voltammetric analysis allowed fast, sensitive, and selective determination of MP in garlic samples. The stripping response was highly linear over the MP concentrations ranging from 0.5 ng mL -1 to 100 ng mL -1 , with a detection limit of 0.1 ng mL -1 . This new nanocomposite-based electrochemical sensor provides an opportunity to develop a field-deployable, sensitive, and quantitative method for monitoring exposure to OPs.

36 MATERIALS SCIENCE↗

Surface and interfacial reaction study of half cycle atomic layer deposited HfO{sub 2} on chemically treated GaSb surfaces

An in situ half-cycle atomic layer deposition/X-ray photoelectron spectroscopy (XPS) study was conducted in order to investigate the evolution of the HfO{sub 2} dielectric interface with GaSb(100) surfaces after sulfur passivation and HCl etching, designed to remove the native oxides. With the first pulses of tetrakis(dimethylamido)hafnium(IV) and water, a decrease in the concentration of antimony oxide states present on the HCl-etched surface is observed, while antimony sulfur states diminished below the XPS detection limit on sulfur passivated surface. An increase in the amount of gallium oxide/sulfide is seen, suggesting oxygen or sulfur transfers from antimony to gallium during antimony oxides/sulfides decomposition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of material collected on swipes using laser-induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) was evaluated to determine elements collected on swipes as surface contamination. A series of long laser plasmas formed along the swipe surface (Post-it paper) interrogated the collected contamination. LIBS detection limits, determined for the elements Ag, As, Ba, Be, Cd, Cr, Cu, Hg, Mn, Ni, Pb, Sr, and Zn on swipes (2 cm{sup 2} area), ranged from 0.002 {mu}g (Be) to 1.46 {mu}g (Pb). The elements were introduced as constituents of synthetic silicate particles serving as a contaminant dust stimulant. The average predicted mass was within 16% of the actual mass on the swipe. The efficiency of collecting particles from surfaces including plastic, Formica, and Al metal was also evaluated. The ability to detect and differentiate two amino acids on a swipe from each other and from the swipe using chemometric modeling techniques was also demonstrated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Near-Tank Treatment of Hanford Tank Waste: Pilot-Scale Testing - 12107

In order to reduce the number of high level waste canisters that will have to be produced by the Hanford Tank Waste Treatment and Immobilization Plant, supplemental waste treatment technologies are being investigated. One such technology is the Near-Tank Treatment System, which uses continuous sludge leaching, filtration, and ion exchange to process the waste in a simple, compact system. The Near Tank Treatment System is ideally suited for handling Hanford tanks with large amounts of boehmite, a difficult aluminum phase to dissolve. A pilot-scale Near Tank Treatment System was constructed and tested with a boehmite and iron oxyhydroxide waste simulant to evaluate the robustness and effectiveness of the system. The data from the pilot-scale tests were also used to assess scale-up from previously performed bench-scale tests. It should be noted that any work involving the use of simulated HLW has inherent limitations. For this work, every attempt was made to ensure that the simulant mimicked the actual waste performance as closely as possible. However, there are always limitations in the ability to The NTTS Demonstration Test established that all the subsystems could be operated concurrently to process the waste simulant. The NTTS had a stable performance during the Demonstration Test that required very little external manipulation once a steady state was achieved. The CSL demonstrated effectively 90% dissolution of the hard to leach boehmite phase. The cross flow filtration system was able to deliver decontaminated salt solution to the NTCR system. The NTCR system exceeded the design basis by providing effluent below the detection limit beyond the design basis required time. The NTTS system was successfully demonstrated and has shown that leaching and decontamination of the subsequent permeate can be readily achieved using relatively small footprint equipment in an at tank application. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Apoferritin-based nanomedicine platform for drug delivery: equilibrium binding study of daunomycin with DNA

Apoferritin is a nanostructured material with a uniform size and spherical structure, and it has excellent bio-compatibility. In this work, we report the use of apoferritin as a novel and biocompatible carrier for stabilizing enzymes and their activities. We used glucose oxidase (GOx) as a model enzyme. GOx was immobilized on the surface of the apoferritin through a green synthetic approach taking advantage of bioaffinity binding between streptavidin and biotin. As a result, a glucose oxidase-biotin/streptavidin/biotin-apoferritin conjugate (Apo-GOx) was prepared using streptavidin as a bridge. The synthesized Apo-GOx was characterized with transmission electron microscopy, ultraviolet, and fluorescence spectroscopy. The activity and stability of GOx on the surface of the apoferritin were studied in different environments, such as temperature, chemicals, and pH, in comparison with the biotinylated GOx (B-GOx). The results showed that the activity of GOx on the apoferritin surface was significantly enhanced. The thermal and chemical stability of the GOx on the apoferritin was also greatly improved compared to free B-GOx in a solution. It was found that the activity of the GOx on the apoferritin only lost 30% in comparison to a 70% loss of free B-GOx after a 2-hr incubation at 50oC. There was almost no decrease in activity for the GOx on the apoferritin as compared to an 80% activity decrease for free B-GOx after 30 minutes of incubation in a 5 M urea solution. The GOx immobilized apoferritin nanoparticles exhibited high sensitivity for glucose detection with a detection limit of 3 nM glucose. This work offers a novel approach for immobilizing enzymes with enhanced stability and activity, and this method may find a number of applications, such as in catalysis and bioassys/biosensors.

59 BASIC BIOLOGICAL SCIENCES↗

SPECKLE INTERFEROMETRY OF SECONDARY COMPONENTS IN NEARBY VISUAL BINARIES

Statistical characterization of secondary subsystems in binaries helps to distinguish between various scenarios of multiple-star formation. The Differential Speckle Survey Instrument was used at the Gemini-N telescope for several hours in 2015 July to probe the binarity of 25 secondary components in nearby solar-type binaries. Six new subsystems were resolved, with meaningful detection limits for the remaining targets. The large incidence of secondary subsystems agrees with other similar studies. The newly resolved subsystem HIP 115417 Ba,Bb causes deviations in the observed motion of the outer binary from which an astrometric orbit of Ba,Bb with a period of 117 years is deduced.

79 ASTRONOMY AND ASTROPHYSICS↗

Airborne flux measurements of ammonia over the Southern Great Plains using chemical ionization mass spectrometry

Ammonia (NH 3 ) is an abundant trace gas in the atmosphere and an important player in atmospheric chemistry, aerosol formation and the atmosphere-surface exchange of nitrogen. It is recognized as a major source of aerosol pollution, and it may limit the formation of cloud nuclei in remote or cold parts of the atmosphere. For soil and plants, NH 3 -mediated nitrogen can act as a harmful pollutant or as a desirable nutrient, mostly in natural and agricultural settings, respectively. Agriculture is also the main source of atmospheric NH 3 via volatilization from fertilizers and manure processing in livestock farming. The accurate determination of NH 3 emission rates remains a challenge, partly due to the propensity of NH 3 to interact with instrument surfaces leading to high detection limits and slow response times. In this paper, we present a new method for quantifying ambient NH 3 , using chemical ionization mass spectrometry (CIMS) with deuterated benzene cations as reagents. The setup aimed at limiting sample-surface interactions and achieved a 1-σ precision of 10–20 pptv and an immediate 1/e response rate < 0.4 s, which compares favorably to the existing state of the art. The sensitivity exhibited an inverse humidity dependence, in particular in relatively dry conditions. Background of up to 10 % of the total signal required consideration as well, as it responded on the order of a few minutes. To showcase the method’s capabilities, we quantified NH3 mixing ratios from measurements obtained during deployment on a Gulfstream I aircraft during the HI-SCALE (Holistic Interactions of Shallow Clouds, Aerosols and Land Ecosystems) field campaign in rural Oklahoma during May 2016. Typical mixing ratios were 1–10 parts per billion by volume (ppbv) for the boundary layer and 0.1–1 ppbv in the lower free troposphere. Sharp plumes of up to 10s of ppbv of NH3 were encountered as well. We identified two of their sources as a large fertilizer plant and a cattle farm, and our mixing ratio measurements yielded upper bounds of 350 ± 50 and 0.6 kg NH 3 h –1 for their respective momentary source rates. The fast response of the CIMS also allowed us to derive vertical NH 3 fluxes within the turbulent boundary layer via eddy covariance, for which we chiefly used the continuous wavelet transform technique. As expected for a region dominated by agriculture, we observed predominantly upward fluxes, implying net NH 3 emissions from surface. The corresponding analysis focused on the most suitable flight, which contained two straight-and-level legs at ~300 m above ground. We derived NH 3 fluxes between –4 and 18 mol km –2 h –1 for these legs, at an effective spatial resolution of 1–2 km. The analysis demonstrated how flux measurements benefit from suitably arranged flight tracks with sufficiently long straight-and-level legs, and explores the detrimental effect of measurement discontinuities. Following flux footprint estimations, comparison to the NH 3 area emissions inventory provided by the US Environmental Protection Agency indicated overall agreement, but also the absence of some sources, for instance the identified cattle farm. Our study concludes that high-precision CIMS measurements are a powerful tool for in-situ measurements of ambient NH 3 mixing ratios, and even allow for the airborne mapping of the air-surface exchange of NH 3 .

54 ENVIRONMENTAL SCIENCES↗

Detection of Cd, Pb, and Cu in non-pretreated natural waters and urine with thiol functionalized mesoporous silica and Nafion composite electrodes

Electrochemical sensors have great potential for environmental monitoring of toxic metal ions in waters due to their portability, field-deployability and excellent detection limits. However, electrochemical sensors employing mercury-free approaches are normally suffered from metal binding competition and fouling by organic substances and surfactants in natural waters, thus tedious sample pretreatments such as wet ashing are needed. In this work, we have developed mercury-free sensors by coating a composite of thiol self-assembled monolayers on mesoporous supports (SH-SAMMS) and Nafion on glassy carbon electrodes. With a combined benefit of SH-SAMMS as outstanding metal preconcentrator and Nafion as antifouling binder, the sensors could detect 2.5 ppb of Cd and 0.5 ppb of Pb in river water, Hanford groundwater, and seawater after 3 and 6 minutes of preconcentration and without sample pretreatment. They could also detect 2.5 ppb of Cd, Pb, and Cu simultaneously after 5 minutes of preconcentration. The electrodes have long life time and excellent single and inter-electrode reproducibility (%RSD of 5 after 8 consecutive measurements). Unlike SAMMS-carbon paste electrodes, the SAMMS-Nafion electrodes were not fouled in samples containing albumin. Successful detection of Cd in human urine was also demonstrated. Other factors including pH effect, diffusion resistance, and Tl interference on the metal detection at SAMMS-Nafion electrodes were studied. With the ability to reliably detect low metal concentration ranges without sample pretreatment and fouling, the SAMMS-Nafion composite sensors have the potential to become the next generation metal analyzers for environmental and bio- monitoring of toxic metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Sample at Mars Analysis (SAM) Detections of CO2 and CO in Sedimentary Material from Gale Crater, Mars: Implications for the Presence of Organic Carbon and Microbial Habitability on Mars

Sedimentary rock samples heated to 860 degrees Centigrade in the SAM (Sample at Mars) instrument evolved CO2 and CO indicating the presence of organic-carbon(C) in Gale Crater materials. Martian or exogenous (meteoritic, interplanetary dust) CO2 and CO could be derived from combustion of simple organics (less than 300 degrees Centigrade), complex refractory organics/amorphous carbon (300-600 degrees Centigrade), and/or magmatic carbon (greater than 600 degrees Centigrade) as result of thermal decomposition of Gale Crater perchlorates, and sulfates present that produce O2. Oxidized organic compounds could also evolve CO2 and CO over broad temperature range (150 to 800 degrees Centigrade) and such organics are expected on Mars via exogenous sources. Alternatively, organic-C could also have been oxidized to carboxylic acids [e.g, mellitic acid (RCOOH), acetate (CH3CO2-), and oxalates (C2O42-)] by oxidative radiolytic weathering, or other oxidation processes. The presence of oxidized organics is consistent with the limited detection of reduced organic-C phases by the SAM-gas chromatography. Organic-C content as determined by CO2 and CO contents could range between 800 and 2400 parts per million C indicating that substantial organic-C component is present in Gale Crater. There are contributions from SAM background however, even in worst-case scenarios, this would only account for as much as half of the detected CO2 and CO. Nevertheless, if organic-C levels were assumed to have existed in a reduced form on ancient Mars and this was bioavailable C, then less than 1 percent of C in Gale Crater sediments could have supported an exclusively heterotrophic microbial population of 1 by 10 (sup 5) cells per gram sediment (assumes 9 by 10 (sup -7) microgram per cell and 0.5 micrograms C per microgram cell). While other essential nutrients (e.g., S and P) could be limiting, organic-C contents, may have been sufficient to support limited heterotrophic microbial populations on ancient Mars.

Sutter, Brad↗

SOLAR MAGNETIC TRACKING. III. APPARENT UNIPOLAR FLUX EMERGENCE IN HIGH-RESOLUTION OBSERVATIONS

Understanding the behavior of weak magnetic fields near the detection limit of current instrumentation is important for determining the flux budget of the solar photosphere at small spatial scales. Using 0.''3-resolution magnetograms from the Solar Optical Telescope's Narrowband Filter Imager (NFI) on the Hinode spacecraft, we confirm that the previously reported apparent unipolar magnetic flux emergence seen in intermediate-resolution magnetograms is indeed the coalescence of previously existing flux. We demonstrate that similar but smaller events seen in NFI magnetograms are also likely to correspond to the coalescence of previously existing weak fields. The uncoalesced flux, detectable only in the ensemble average of hundreds of these events, accounts for 50% of the total flux within 3 Mm of the detected features. The spatial scale at which apparent unipolar emergence can be directly observed as coalescence remains unknown. The polarity of the coalescing flux is more balanced than would be expected given the imbalance of the data set, however without further study we cannot speculate whether this implies that the flux in the apparent unipolar emergence events is produced by a granulation-scale dynamo or is recycled from existing field.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SOURCE DENSITY AND OBSERVABILITY OF PAIR-INSTABILITY SUPERNOVAE FROM THE FIRST STARS

Theoretical models predict that some of the first stars ended their lives as extremely energetic pair-instability supernovae (PISNe). With energies approaching 10{sup 53} erg, these supernovae are expected to be within the detection limits of the upcoming James Webb Space Telescope (JWST), allowing observational constraints to be placed on the properties of the first stars. We estimate the source density of PISNe using a semi-analytic halo mass function based approach, accounting for the effects of feedback from star formation on the PISN rate using cosmological simulations. We estimate an upper limit of {approx}0.2 PISNe per JWST field of view at any given time. Feedback can reduce this rate significantly, e.g., lowering it to as little as one PISN per 4000 JWST fields of view for the most pessimistic explosion models. We also find that the main obstacle to observing PISNe from the first stars is their scarcity, not their faintness; exposures longer than a few times 10{sup 4} s will do little to increase the number of PISNe found. Given this, we suggest a mosaic style search strategy for detecting PISNe from the first stars. Even rather high-redshift PISNe are unlikely to be missed by moderate exposures, and a large number of pointings will be required to ensure a detection.

79 ASTRONOMY AND ASTROPHYSICS↗

PAPER-64 CONSTRAINTS ON REIONIZATION. II. THE TEMPERATURE OF THE z = 8.4 INTERGALACTIC MEDIUM

We present constraints on both the kinetic temperature of the intergalactic medium (IGM) at z = 8.4, and on models for heating the IGM at high-redshift with X-ray emission from the first collapsed objects. These constraints are derived using a semi-analytic method to explore the new measurements of the 21 cm power spectrum from the Donald C. Backer Precision Array for Probing the Epoch of Reionization (PAPER), which were presented in a companion paper, Ali et al. Twenty-one cm power spectra with amplitudes of hundreds of mK{sup 2} can be generically produced if the kinetic temperature of the IGM is significantly below the temperature of the cosmic microwave background (CMB); as such, the new results from PAPER place lower limits on the IGM temperature at z = 8.4. Allowing for the unknown ionization state of the IGM, our measurements find the IGM temperature to be above ≈5 K for neutral fractions between 10% and 85%, above ≈7 K for neutral fractions between 15% and 80%, or above ≈10 K for neutral fractions between 30% and 70%. We also calculate the heating of the IGM that would be provided by the observed high redshift galaxy population, and find that for most models, these galaxies are sufficient to bring the IGM temperature above our lower limits. However, there are significant ranges of parameter space that could produce a signal ruled out by the PAPER measurements; models with a steep drop-off in the star formation rate density at high redshifts or with relatively low values for the X-ray to star formation rate efficiency of high redshift galaxies are generally disfavored. The PAPER measurements are consistent with (but do not constrain) a hydrogen spin temperature above the CMB temperature, a situation which we find to be generally predicted if galaxies fainter than the current detection limits of optical/NIR surveys are included in calculations of X-ray heating.

79 ASTRONOMY AND ASTROPHYSICS↗

Thin-film chemical expansion of ceria based solid solutions: laser vibrometry study

The chemical expansion of Pr 0.1 Ce 0.9 O 2-δ (PCO) and CeO 2-δ thin films is investigated in the temperature range between 600 °C and 800 °C by laser Doppler vibrometry (LDV). It enables non-contact determination of nanometer scale changes in film thickness at high temperatures. The present study is the first systematic and detailed investigation of chemical expansion of doped and undoped ceria thin films at temperatures above 650 °C. The thin films were deposited on yttria stabilized zirconia substrates (YSZ), operated as an electrochemical oxygen pump, to periodically adjust the oxygen activity in the films, leading to reversible expansion and contraction of the film. This further leads to stresses in the underlying YSZ substrates, accompanied by bending of the overall devices. Film thickness changes and sample bending are found to reach up to 10 and several hundred nanometers, respectively, at excitation frequencies from 0.1 to 10 Hz and applied voltages from 0–0.75 V for PCO and 0–1 V for ceria. At low frequencies, equilibrium conditions are approached. As a consequence maximum thin-film expansion of PCO is expected due to full reduction of the Pr ions. The lower detection limit for displacements is found to be in the subnanometer range. At 800 °C and an excitation frequency of 1 Hz, the LDV shows a remarkable resolution of 0.3 nm which allows, for example, the characterization of materials with small levels of expansion, such as undoped ceria at high oxygen partial pressure. As the correlation between film expansion and sample bending is obtained through this study, a dimensional change of a free body consisting of the same material can be calculated using the high resolution characteristics of this system. A minimum detectable dimensional change of 5 pm is estimated even under challenging high-temperature conditions at 800 °C opening up opportunities to investigate electro-chemo-mechanical phenomena heretofore impossible to investigate. The expansion data are correlated with previous results on the oxygen nonstoichiometry of PCO thin films, and a defect model for bulk ceria solid solutions is adopted to calculate the cation and anion radii changes in the constrained films during chemical expansion. The constrained films exhibit anisotropic volume expansion with displacements perpendicular to the substrate plane nearly double that of bulk samples. The PCO films used here generate high total displacements of several 100 nm’s with high reproducibility. Consequently, PCO films are identified to be a potential core component of high-temperature actuators. They benefit not only from high displacements at temperatures where most piezoelectric materials no longer operate while exhibiting, low voltage operation and low energy consumption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗