Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Prototyping the Light Detection of the DUNE Near Detector

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment with a 70kt liquid argon time projection chamber (LAr TPC) at the Far Detector complex at the Sanford Underground Research Facility (SURF) and a Near Detector (ND) complex planned for the Fermi National Accelerator Laboratory. The ND complex plans for three detector subsystems, including a modular LAr TPC comprised of 35 optically segregated modules. The modular detector design required the development a novel dielectric light readout, the ArCLight technology, which can be operated in a high voltage environment and has a large active surface. A demonstrator of four modular detectors, DUNE ND-LAr 2x2, will operate in 2023 in Fermilab's NuMI beam. After the construction of the modules was completed, they were successfully operated and commissioned in liquid argon using cosmic-ray muons at the University of Bern. This talk will discuss the designs of the light readout systems used in these modules with focus on the construction and commissioning of the ArCLights as well as the performance of the LRS during the tests at Bern.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Development of a TES-Based Anti-Coincidence Detector for Future X-ray Observatories

Microcalorimeters onboard future x-ray observatories require an anti-coincidence detector to remove environmental backgrounds. In order to most effectively integrate this anticoincidence detector with the main microcalorimeter array, both instruments should use similar read-out technology. The detectors used in the Cryogenic Dark Matter Search (CDMS) use a phonon measurement technique that is well suited for an anti-coincidence detector with a microcalorimeter array using SQUID readout. This technique works by using a transition-edge sensor (TES) connected to superconducting collection fins to measure the athermal phonon signal produced when an event occurs in the substrate crystal. Energy from the event propagates through the crystal to the superconducting collection fins, creating quasiparticles, which are then trapped as they enter the TES where they produce a signal. We are currently developing a prototype anti-coincidence detector for future x-ray missions and have recently fabricated test devices with Mo/Au TESs and Al collection fins. We will present results from the first tests of these devices which indicate a proof of concept that quasiparticle trapping is occurring in these materials.

Bailey, Catherine↗

Development of a TES-Based Anti-Coincidence Detector for Future X-Ray Observations

Microcalorimeters onboard future x-ray observatories require an anticoincidence detector to remove environmental backgrounds. In order to most effectively integrate this anti-coincidence detector with the main microcalorimeter array, both instruments should use similar read-out technology. The detectors used in the Cryogenic Dark Matter Search (CDMS) use a phonon measurement technique that is well suited for an anti-coincidence detector with a microcalorimeter array using SQUID readout. This technique works by using a transition-edge sensor (TES) connected to superconducting collection fins to measure the athermal phonon signal produced when an event occurs in the substrate crystal. Energy from the event propagates through the crystal to the superconducting collection fins, creating quasiparticles, which are then trapped as they enter the TES where they produce a signal. We are currently developing a prototype anti-coincidence detector for future x-ray missions and have recently fabricated test devices with Mo/Au TESs and Al collection fins. We present results from the first tests of these devices which indicate a proof of concept that quasiparticle trapping is occurring in these materials.

Bailey, Catherine N.↗

The MicroBooNE Technical Design Report

MicroBooNE will build, operate, and extract physics from the first large liquid argon time projection chamber (LArTPC) that will be exposed to a high-intensity neutrino beam. With its unparalleled capabilities in tracking, vertexing, calorimetry, and particle identification, all with full electronic readout, MicroBooNE represents a major advance in detector technology for neutrino physics in the energy regime of most importance for elucidating oscillation phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor requirements for Earth and planetary observations

Future generations of Earth and planetary remote sensing instruments will require extensive developments of new long-wave and very long-wave infrared detectors. The upcoming NASA Earth Observing System (EOS) will carry a suite of instruments to monitor a wide range of atmospheric and surface parameters with an unprecedented degree of accuracy for a period of 10 to 15 years. These instruments will observe Earth over a wide spectral range extending from the visible to nearly 17 micrometers with a moderate to high spectral and spacial resolution. In addition to expected improvements in communication bandwidth and both ground and on-board computing power, these new sensor systems will need large two-dimensional detector arrays. Such arrays exist for visible wavelengths and, to a lesser extent, for short wavelength infrared systems. The most dramatic need is for new Long Wavelength Infrared (LWIR) and Very Long Wavelength Infrared (VLWIR) detector technologies that are compatible with area array readout devices and can operate in the temperature range supported by long life, low power refrigerators. A scientific need for radiometric and calibration accuracies approaching 1 percent translates into a requirement for detectors with excellent linearity, stability and insensitivity to operating conditions and space radiation. Current examples of the kind of scientific missions these new thermal IR detectors would enhance in the future include instruments for Earth science such as Orbital Volcanological Observations (OVO), Atmospheric Infrared Sounder (AIRS), Moderate Resolution Imaging Spectrometer (MODIS), and Spectroscopy in the Atmosphere using Far Infrared Emission (SAFIRE). Planetary exploration missions such as Cassini also provide examples of instrument concepts that could be enhanced by new IR detector technologies.

Chahine, Moustafa T.↗

Reconstructing Solar Particle Event Spectra from Absorbed Dose Measurements

The space radiation environment is unlike anything encountered on Earth. It is dominated by heavy charged particles consisting of highly charged nuclei with atomic numbers ranging from 1 to 94 with a broad spectrum of kinetic energies. The three primary sources of radiation in space are trapped belts, galactic cosmic rays (GCRs), and solar particle events (SPEs). The trapped belts are only of concern near bodies with significant magnetic fields and GCR flux spectra are relatively well-predicted using models that account for solar modulation of the local interstellar spectrum. SPEs, which consist primarily of protons, are difficult to predict in terms of occurrence, duration, intensity, and energy spectrum. SPE intensity and energy spectrum are critical for understanding radiation exposure-related health effects for astronauts in space. The National Aeronautics and Space Administration (NASA) relies on data from the Geostationary Operational Environmental Satellite series to characterize intensities and energy spectra of SPEs near Earth. However, these data are not applicable for spacecraft in other regions of the solar system. To understand the radiation environment for astronauts embarking on travel beyond Earth orbit, NASA is developing the Hybrid Electronic Radiation Assessor (HERA), a distributed dosimetry system that employs a solid-state silicon sensor coupled with the Timepix readout chip. The pixelated nature of the detector permits detailed analyses of charged particle tracks which can then be used to characterize the fluence spectrum at the location of the detector. Despite the unprecedented level of detail regarding the radiation environment provided by these detectors, knowledge of the fluence spectrum at all locations within the vehicle, specifically inside of astronauts, is desired to fully characterize the associated risk of harmful health effects. Radiation transport of the external radiation environment, considering the shielding provided by the vehicle, other objects, and even astronauts, is performed to obtain this information. Thus, there is clearly a need to define the external radiation environment using measurements performed within the vehicle. The number of detectors that may be flown as a part of HERA is limited by logistics, including data, power, and mass restrictions. The current configuration for crewed flight consists of six detectors at various locations with in the Orion Multi-Purpose Crew Vehicle (MPCV). It follows that an external proton fluence spectrum can be characterized with at most six energy bins with traditional matrix inversion techniques. The purpose of the present study is to determine whether it is possible to reconstruct SPE spectra with greater resolution from absorbed dose measurements and knowledge of the response of individual detectors using linear programming.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R&D studies of the ATLAS LAr calorimeter readout electronics for super-LHC

The ATLAS Liquid Argon (LAr) calorimeters are high precision, high sensitivity and high granularity detectors. A total of 182,468 signals are digitized and processed real-time on detector, to provide energy and time deposited in each detector element at every occurrence of the L1-trigger. The current readout electronics will need to be upgraded to sustain the higher radiation levels expected with the increase of a factor 10 in luminosity at the LHC in the years {approx}2017. A completely innovative readout scheme is being developed. The front-end readout will send out data continuously at each bunch crossing through high speed radiation resistant optical links, the data will be processed real-time with the possibility of implementing trigger algorithms. This article is an overview of the R&D activities and architectural studies the ATLAS LAr Calorimeter Group is developing: front-end analog and mixed-signal ASIC design, radiation resistance optical-links in SOS, high-speed back-end processing units based on FPGA architectures and power supply distribution schemes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Fast Event Preprocessor and Sequencer for the Simbol-X Low Energy Detector

The Simbol-X Low Energy Detector (LED), a 128x128 pixel DEPFET (Depleted Field Effect Transistor) array, will be read out at a very high rate (8000 frames/second) and, therefore, requires a very fast on board electronics. We present an FPGA-based LED camera electronics consisting of an Event Preprocessor (EPP) for on board data preprocessing and filtering of the Simbol-X low-energy detector and a related Sequencer (SEQ) to generate the necessary signals to control the readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a thermal neutron detector based on scintillating fibers and silicon photomultipliers

We propose a technique for thermal neutron detection, based on a {sup 6}Li converter placed in front of scintillating fibers readout by means of silicon photomultipliers. Such a technique allows building cheap and compact detectors and dosimeters, thus possibly opening new perspectives in terms of granular monitoring of neutron fluxes as well as space-resolved neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Novel Si(1-x)Ge(x)/Si heterojunction internal photoemission long wavelength infrared detectors

There is a major need for long-wavelength-infrared (LWIR) detector arrays in the range of 8 to 16 microns which operate with close-cycle cryocoolers above 65 K. In addition, it would be very attractive to have Si-based infrared (IR) detectors that can be easily integrated with Si readout circuitry and have good pixel-to-pixel uniformity, which is critical for focal plane array (FPA) applications. Here, researchers report a novel Si(1-x)Ge(x)/Si heterojunction internal photoemission (HIP) detector approach with a tailorable long wavelength infrared cutoff wavelength, based on internal photoemission over the Si(1-x)Ge(x)/Si heterojunction. The HIP detectors were grown by molecular beam epitaxy (MBE), which allows one to optimize the device structure with precise control of doping profiles, layer thickness and composition. The feasibility of a novel Si(1-x)Ge(x)/Si HIP detector has been demonstrated with tailorable cutoff wavelength in the LWIR region. Photoresponse at wavelengths 2 to 10 microns are obtained with quantum efficiency (QE) above approx. 1 percent in these non-optimized device structures. It should be possible to significantly improve the QE of the HIP detectors by optimizing the thickness, composition, and doping concentration of the Si(1-x)Ge(x) layers and by configuring the detector for maximum absorption such as the use of a cavity structure. With optimization of the QE and by matching the barrier energy to the desired wavelength cutoff to minimize the thermionic current, researchers predict near background limited performance in the LWIR region with operating temperatures above 65K. Finally, with mature Si processing, the relatively simple device structure offers potential for low-cost producible arrays with excellent uniformity.

Lin, T. L.↗

Digital signal processing for the ATLAS/LUCID detector

Both the detector and the associated read-out electronics have been improved in order to cope with the LHC luminosity increase foreseen for RUN 2 and RUN 3. The new operating conditions require a careful tuning of the read-out electronics in order to optimize the signal-to-noise ratio. The new read-out electronics will allow the use of digital filtering of the photo multiplier tube signals. In this talk, we will present the first results that we obtained in the optimization of the signal-to-noise ratio. In addition, we will introduce the next steps to adapt this system to high performance read-out chains for low energy gamma rays. Such systems are based, for instance, on Silicon Drift Detector devices and can be used in applications at Free-Electron-Laser facilities such as the XFEL under construction at DESY. (authors)

43 PARTICLE ACCELERATORS↗

High count rate thermal neutron detectors and electronics

Improved, high count rate thermal neutron counters and electronics enabling new, higher measurement capabilities are disclosed. Next generation 3He and 10B tubes may include an electronics package capable of operating at higher count rates and in higher gamma fields and providing more efficient use of 3He gas. Conventional detector systems may also be upgraded, providing a possible solution to measure spent nuclear fuel with high neutron efficiency previously not possible in 235U fission counter systems. Switching the number of tubes per amplifier allows use of the measured nuclear material for a calibration standard for dead time correction, increasing accuracy of neutron measurements systems. An optimized detector geometry and advanced electronics with double pulse filtering and a dual channel readout may be provided. A bipolar shaper may improve dead time, provide efficient detector use, reduce double pulsing, facilitate high count rate measurements, and allow remote threshold setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A scanning CCD detector for powder diffraction measurements

Several different approaches have traditionally been used for detection of X-ray powder diffraction patterns, including area detectors, point detectors and position-sensitive detectors. Each has advantages. This paper discusses use of a low-cost CCD detector attached to a diffractometer arm, where line-by-line readout of the CCD is coupled to continuous motion of the arm. When this type of detector is used and where X-ray optics are employed to focus the source image onto the detector plane both high-resolution and rapid measurements can be performed, with data collection over a complete 2θ range. This is particularly advantageous for synchrotron applications but valuable also for Guinier diffractometer laboratory instruments. Peak resolutions are shown to be moderately better than what can be obtained with a position-sensitive detector and significantly better than with an area detector. Many samples have intrinsically broadened peak shapes for which little improvement in data quality could be obtained with an analyzer-crystal detector. With comparable numbers of modules, these CCD data collection speeds can be close to those with position-sensitive detectors, but without the low-angle asymmetry seen in the latter.

Toby, B. H.↗

Development of a 10 picosecond time-of-flight Counter

This Advanced Detector Research proposal presented a plan to develop an extremely fast time-of-flight detector for measuring the arrival time of beam protons scattered at small angles in high energy hadron colliders, such as the Large Hadron Collider (LHC). The proposed detectors employ a gas or quartz Cerenkov radiator which produce light when a proton passes through them, coupled to a micro-channel plate photomultiplier tube (MCP-PMT) that converts the light to an electrical pulse. The very small jitter of the pulse time provided by the MCP-PMT, combined with downstream electronics that accurately measure the pulse time results in a time-of-flight measurement of unprecedented accuracy. This ADR proposal was extremely successful, culminating in the development of a 10 ps resolution time-of-flight system, about an order of magnitude better than any time-of-flight system previously deployed at a collider experiment. The primary areas of advance were the usage of new radiator geometries providing fast detector signals, using multiple measurements to obtain a superior system resolution, and development of an electronics readout system tuned to maintain the excellent timing afforded by the detector. Test beam and laser tests have improved the knowledge of MCP-PMT’s and enabled the evaluation of the new detector concepts. In addition to being a generally useful detector concept, these fast timing detectors are a major component of proposed upgrades to the LHC ATLAS and CMS detectors, and if deployed could significantly enhance the discovery potential of these detectors, including contributions to the measurement of the properties of the Higgs Boson. In addition to the potential for furthering fundamental understanding of nature, the knowledge gained on MCP-PMT’s could be useful in developing improved versions of these devices which have promise in diverse fields such as biological and medical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test results of a counting type SOI device for a new x-ray area detector

Development of a new detector using Silicon-On-Insulator (SOI) technology has been started in the Photon Factory, KEK. The aim of this project is to develop a pulse-counting-type X-ray detector that can be used in synchrotron radiation experiments using soft X-rays. We started to make a Test Element Group of SOI chip, which is called CPIXPTEG1 and evaluated its performance. We succeeded in readout of output signals for 16 keV X-rays from the SOI chips. We also found that the middle-SOI structure was effective against a signal distortion caused by hole traps in the buried oxide layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Super DREAM Project

Despite the fact that DOE provided only a fraction of the requested funds, the goals we defined in the proposal on which award ER41783 was based were essentially all met. This was partially due to the fact that other funding agencies, which supported our collaborators (especially from Italy and Korea) contributed as well, and partially due to the effective solutions that were developed to compensate for the fact that the detector we had proposed to build had to be scaled down. The performance of the SuperDREAM calorimeter is better than anything that has been built or proposed so far. This has of course not gone unnoticed in the scientific community. Scientists who are preparing experiments for the proposed new generation of particle accelerators (FCCee, CPEC,..) are all very seriously considering the technology developed in this project. Several new collaborations have formed which aim to adapt the dual-readout calorimeter principles to the demands of a 4 environment. Preliminary measurements using silicon photomultipliers as light sensors have already been carried out. This type of readout would make it possible to operate this detector in a magnetic field, and it would also allow for a longitudinal segmentation into electromagnetic and hadronic sections, if so desired. In addition, SiPM readout would eliminate the need for “forests” of fibers sticking out of the rear end of the calorimeter (Figure 1), and obtain an arbitrary fine lateral segmentation, which might be very important for recognizing electrons inside jets. The improvements in our understanding of the fundamental structure of matter and the forces that govern its behavior have always hinged on the availability of detectors that make it possible to explore the possibilities of new, more powerful particle accelerators to the fullest extent. We believe that the SuperDREAM project has created a quantum leap in detector technology, which may turn out to be crucially important for future discoveries in particle physics.

43 PARTICLE ACCELERATORS↗