AFR-100 Sodium-CO 2 Reaction Analysis
Pressure-boundary failure within the heat-source heat exchanger (IHTS-fluid to secondary-fluid heat exchanger) in a sodium-cooled reactor will lead to a violent decompression on the secondary side and large pressure transients in the IHTS. If the secondary fluid is water or CO 2 , the pressure transients will be intensified by an energetic reaction between the sodium & water or sodium & CO 2 . The coupling of secondary-fluid injection, reaction dynamics, product gas bubble growth, and sodium system response results in a succession of short duration, high intensity pressure pulses travelling in the heat-source heat exchanger and IHTS. Each pulse has higher amplitude than the preceding one if no mitigating features such as rupture disks and gas spaces are provided in the system design. Pressure pulse absorption features and relief systems must be included in the IHTS design to prevent structural damage to the heat-source heat exchanger, and IHTS piping. In the case of the AFR-100 design, the boundary between the IHTS sodium and the secondary-side CO 2 within the sodium-CO 2 heat exchanger could potentially fail. The resulting fluid-hammer and sodium-CO 2 reaction must be mitigated. A variety of heat exchangers types have been proposed for the sodium-CO 2 side. Thus, the following analysis of the IHTS response to a sodium-CO 2 reaction includes a wide range of potential break sizes to cover this spectrum of heat exchanger types. The IHTS pressure response due to leak sizes ranging from 2.0 mm – 16.1 mm were evaluated. Double-ended guillotine tube breaks at the top, center, and bottom of the tube bundle were also considered. As expected, the peak reaction bubble pressure increased and rupture disk burst time decreased as the break size increased. As currently designed, all components, including the sodium-CO 2 heat exchanger tubes and shell and the IHX tubes, can withstand the maximum pressures calculated.