Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Germanium as negative electrode material for sodium-ion batteries

Germanium electrodes show a reversible Na-ion reaction at potentials of 0.15 and 0.6 V during discharge and charge, respectively. The reaction is accompanied with a reversible capacity close to 350 mAh g-1, which matches the value expected for the formation of NaGe. The electrode capacity retention is stable over 15 cycles but declines somewhat rapidly afterwards. This decline is typical for alloying systems undergoing large volume expansion, and calls for engineering solutions to confine the mechanical stress and control the electrolyte decomposition reactions that are likely to be the main sources of degradations. The rate performance results highlight the huge potential of nanosized germanium as a potential Na-ion anode. The reaction kinetics is found to be very good with about 220 mAh g-1 delivered at 170 C. Finally, the preliminary XRD results do not reveal the formation of crystalline phases at full (dis)charge.

Baggetto, Loic↗

An information diffusion technique to assess integrated hazard risks

An integrated risk is a scene in the future associated with some adverse incident caused by multiple hazards. An integrated probability risk is the expected value of disaster. Due to the difficulty of assessing an integrated probability risk with a small sample, weighting methods and copulas are employed to avoid this obstacle. To resolve the problem, in this paper, we develop the information diffusion technique to construct a joint probability distribution and a vulnerability surface. Then, an integrated risk can be directly assessed by using a small sample. A case of an integrated risk caused by flood and earthquake is given to show how the suggested technique is used to assess the integrated risk of annual property loss.

58 GEOSCIENCES↗

Analytical Determination of Radioactive Strontium and Cesium by Thermal Ionization Mass Spectrometry

Thermal ionization mass spectrometry (TIMS) has been evaluated for the detection of the radioactive isotopes of strontium and cesium. The instrument was investigated for the analysis of isotopic ratios of 89Sr to 90Sr and 135Cs to 137Cs in the presence of atomic isobars (Y and Zr for Sr analysis and Ba for Cs analysis). Signicant discrimination using TIMS was found for both Sr and Cs through evaluation using stable isotopes. Fusion procedures with different flux were evaluated for preparation of sample matrices. Chemical separations were developed and used after fusion to isolate the Sr and Cs from a prepared background matrix (i.e., Montana Soil). A graded approach, increasing in stable background isotopes, was performed to monitor the chemistry and instrument response. A thermal neutron irradiation was performed to produce a sample that contained the radioisotopes of Sr and Cs. Even though the irradiated sample was not a certified standard it does provide accurate expectation values via published, well understood cumulative fission yield data. The results presented in this work correlate extremely well with the published data. Furthermore, a significant decrease in uncertainty (by a factor of 5 { 10) was found for the isotopic ratios measured with TIMS compared to the published values.

TIMS, environmental contamination, radiostrontium,↗

A Method to Estimate Mean Position, Motion Magnitude, Motion Correlation, and Trajectory of a Tumor From Cone-Beam CT Projections for Image-Guided Radiotherapy

Purpose: To develop a probability-based method for estimating the mean position, motion magnitude, and trajectory of a tumor using cone-beam CT (CBCT) projections. Method and Materials: CBCT acquisition was simulated for more than 80 hours of patient-measured trajectories for thoracic/abdominal tumors and prostate. The trajectories were divided into 60-second segments for which CBCT was simulated by projecting the tumor position onto a rotating imager. Tumor (surrogate) visibility on all projections was assumed. The mean and standard deviation of the tumor position and motion correlation along the three axes were determined with maximum likelihood estimation based on the projection data, assuming a Gaussian spatial distribution. The unknown position component along the imager axis was approximated by its expectation value, determined by the Gaussian distribution. Transformation of the resulting three-dimensional position to patient coordinates provided the estimated trajectory. Two trajectories were experimentally investigated by CBCT acquisition of a phantom. Results: The root-mean-square error of the estimated mean position was 0.05 mm. The root-mean-square error of the trajectories was <1 mm in 99.1% of the thorax/abdomen cases and in 99.7% of the prostate cases. The experimental trajectory estimation agreed with the actual phantom trajectory within 0.44 mm in any direction. Clinical applicability was demonstrated by estimating the tumor trajectory for a pancreas cancer case. Conclusions: A method for estimation of mean position, motion magnitude, and trajectory of a tumor from CBCT projections has been developed. The accuracy was typically much better than 1 mm. The method is applicable to motion-inclusive, respiratory-gated, and tumor-tracking radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical analysis of the Burgers' equation in the presence of uncertainty

The Burgers' equation with uncertain initial and boundary conditions is investigated using a polynomial chaos (PC) expansion approach where the solution is represented as a truncated series of stochastic, orthogonal polynomials. The analysis of well-posedness for the system resulting after Galerkin projection is presented and follows the pattern of the corresponding deterministic Burgers equation. The numerical discretization is based on spatial derivative operators satisfying the summation by parts property and weak boundary conditions to ensure stability. Similarly to the deterministic case, the explicit time step for the hyperbolic stochastic problem is proportional to the inverse of the largest eigenvalue of the system matrix. The time step naturally decreases compared to the deterministic case since the spectral radius of the continuous problem grows with the number of polynomial chaos coefficients. An estimate of the eigenvalues is provided. A characteristic analysis of the truncated PC system is presented and gives a qualitative description of the development of the system over time for different initial and boundary conditions. It is shown that a precise statistical characterization of the input uncertainty is required and partial information, e.g. the expected values and the variance, are not sufficient to obtain a solution. An analytical solution is derived and the coefficients of the infinite PC expansion are shown to be smooth, while the corresponding coefficients of the truncated expansion are discontinuous.

97 MATHEMATICS AND COMPUTING↗

A corrected method for Coulomb scattering in arbitrarily weighted particle-in-cell plasma simulations

A physically and statistically accurate method to perform binary, pairwise Coulomb collisions for arbitrarily-weighted macroparticles in particle-in-cell simulations is described. The method is shown to conserve global energy and momentum on average and to produce physically accurate scattering frequencies. This is justified using the statistically expected values of the method and through a series of numerical tests showing that the method is valid independently of macroparticle weight. This novel method is required due to an error in previous work on binary scattering, initially by Nanbu and Yonemura [J. Comp. Phys. 145, 639 (1998)] and applied to subsequent work, that causes inaccuracies in the scattering frequencies for unequally weighted simulations; a problem that occurs both for scattering within the group and between different groups.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Epitaxial columnar growth of strain-free antiferromagnetic Weyl semimetal Mn 3 Sn on wurtzite c -plane GaN/Al 2 O 3 (0001)

Weyl semimetal thin films with excellent crystalline quality are of great interest for antiferromagnetic spintronics. Mn 3 Sn is one Weyl semimetal with great properties and promise for exciting science and applications. It has proven very challenging, however, to grow Mn 3 Sn thin films with smooth surfaces, negligible strain, and excellent crystallinity. In this work, we discuss the successful preparation of epitaxial Mn 3 Sn (0001)-oriented thin films via molecular beam epitaxial growth on c -plane wurtzite GaN which was grown by MBE on Al 2 O 3 (0001). We present the reflection high energy electron diffraction analysis along with x-ray diffraction in order to demonstrate the crystalline quality of the film, and we give atomic models to explain the epitaxial orientation relationships between the crystal lattices of the substrate, GaN layer, and Mn 3 Sn layer. Importantly, we discuss the film lattice parameters as compared to expected values, demonstrating negligible strain both in-plane and out-of-plane . Atomic force microscopy reveals an epitaxial columnar growth mode characterized by flat-top-mesa islands, while scanning tunneling microscopy shows the atomically smooth surfaces of the mesa-top structures. Finally, Rutherford backscattering informs the stoichiometry of the film as well as the layer thicknesses.

Chiral antiferromagnetic material↗

Quantifying the effect of hydride microstructure on zirconium alloys embrittlement using image analysis

Since hydride microstructure can significantly influence Zr alloy nuclear fuel cladding’s ductility, a new metric has been developed to quantify hydride microstructure in 2D micrographs and relate it to crack propagation. As cladding failure usually results from a hoop stress, this new metric, called the Radial Hydride Continuous Path (RHCP), is based on quantifying the continuity of brittle hydride particles along the radial direction of the cladding tube. Compared to previous metrics, this approach more closely relates to the propensity of a crack to propagate radially through the cladding tube thickness. The RHCP takes into account hydride length, orientation, and connectivity to choose the optimal path for crack propagation through the cladding thickness. The RHCP can therefore be more closely linked to hydride embrittlement of the Zr alloy material, thus creating a relationship between material structure, properties, and performance. The new definition, along with previously proposed metrics such as the Radial Hydride Fraction (RHF), the Hydride Continuity Coefficient (HCC), and the Radial Hydride Continuity Factor (RHCF), have been implemented and automated in MATLAB. These codes are made available with this publication as supplementary materials. These metrics were verified by comparing their predictions of hydride morphology against expected values in simple cases, and the implementation of the new metric was validated by comparing its predictions with manual measurements of hydride microstructure performed on ImageJ. The RHCP was also validated against experimental measurements of fracture behavior and it was shown to correlate with cladding failure better than previous metrics. The information provided by these metrics will help accurately assess cladding integrity during operation, transportation, and storage.

36 MATERIALS SCIENCE↗

Reformulation of Density Functional Theory for N-Representable Densities and the Resolution of the v-Representability Problem

Density functional theory for the case of general, N-representable densities is reformulated in terms of density functional derivatives of expectation values of operators evaluated with wave functions leading to a density, making no reference to the concept of potential. The developments provide a complete solution of the v-representability problem by establishing a mathematical procedure that determines whether a density is v-representable and in the case of an affirmative answer determines the potential (within an additive constant) as a derivative with respect to the density of a constrained search functional. It also establishes the existence of an energy functional of the density that, for v-representable densities, assumes its minimum value at the density describing the ground state of an interacting many-particle system. The theorems of Hohenberg and Kohn emerge as special cases of the formalism.

36 MATERIALS SCIENCE↗

Structural and magnetic properties of pyrochlore solid solutions (Y,Lu){sub 2}Ti{sub 2-x}(Nb,Ta){sub x}O{sub 7{+-}}{sub y}

The synthesis and characterization of the pyrochlore solid solutions, Y{sub 2}Ti{sub 2-x}Nb{sub x}O{sub 7-y}, Lu{sub 2}Ti{sub 2-x}Nb{sub x}O{sub 7-y}, Y{sub 2}Ti{sub 2-x}Ta{sub x}O{sub 7-y} and Lu{sub 2}TiTaO{sub 7-y} (-0.4<y<0.5), is described. Synthesis at 1600 deg. C, and 10{sup -5} Torr yields oxygen deficiency in all systems. All compounds are found to be paramagnetic and semiconducting, with the size of the local moments being less, in some cases substantially less, than the expected value for the number of nominally unpaired electrons present. Thermogravimetric analysis (TGA) shows that all compounds can be fully oxidized while retaining the pyrochlore structure, yielding oxygen rich pyrochlores as white powders. Powder neutron diffraction of Y{sub 2}TiNbO{sub 7}-based samples was done. Refinement of the data for oxygen deficient Y{sub 2}TiNbO{sub 6.76} indicates the presence of a distribution of oxygen over the 8b and 48f sites. Refinement of the data for oxygen rich Y{sub 2}TiNbO{sub 7.5} shows these sites to be completely filled, with an additional half filling of the 8a site. The magnetic and TGA data strongly suggest a preference for a Ti{sup 3+}/(Nb,Ta){sup 5+} combination, as opposed to Ti{sup 4+}/(Nb,Ta){sup 4+}, in this pyrochlore family. In addition, the evidence clearly points to Ti{sup 3+} as the source of the localized moments, with no evidence for localized Nb{sup 4+} moments. - Graphical abstract: Synthesis of pyrochlore solid solutions (Y,Lu){sub 2}Ti{sub 2-x}(Nb,Ta){sub x}O{sub 7{+-}}{sub y} under high vacuum at 1600 deg. C results in oxygen deficient, paramagnetic compounds with reduced B-site cations. Studies indicate Ti{sup 3+} as the source of the localized moments, with no evidence for localized Nb{sup 4+} moments. Annealing under O{sub 2} results in fully oxidized, oxygen excess pyrochlores as white powders. Powder neutron diffraction studies show the excess oxygen on the normally vacant 8a site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal structure and magnetic properties of Ce{sub 7}Ni{sub 5{+-}x}Ge{sub 3{+-}x}In{sub 6} and Pr{sub 7}Ni{sub 5{+-}x}Ge{sub 3{+-}x}In{sub 6}

The indides Ce{sub 7}Ni{sub 5{+-}x}Ge{sub 3{+-}x}In{sub 6} and Pr{sub 7}Ni{sub 5{+-}x}Ge{sub 3{+-}x}In{sub 6} were synthesized from the elements by arc-melting of the components. Single crystals were grown via special annealing sequences. Both structures were solved from X-ray single crystal diffraction data: new structure type, P6/m, Z=1, a=11.385(2), c=4.212(1) A, wR{sub 2}=0.0640, 634F{sup 2} values, 25 variables for Ce{sub 7}Ni{sub 4.73}Ge{sub 3.27}In{sub 6} and a=11.355(6), c=4.183(2) A, wR{sub 2}=0.0539, 563F{sup 2} values, 25 variables for Pr{sub 7}Ni{sub 4.96}Ge{sub 3.04}In{sub 6}. Both indides show homogeneity ranges through Ni/Ge mixing (M sites). This new structure type can be derived from the AlB{sub 2} structure type by a substitution of the Al and B atoms by CeM{sub 12} and NiIn{sub 6}Ce{sub 3} polyhedra (tricapped trigonal prism). Magnetic susceptibility measurements on a polycrystalline sample of Ce{sub 7}Ni{sub 5}Ge{sub 3}In{sub 6} indicated Curie-Weiss like paramagnetic behavior down to 1.71 K with the effective magnetic moment slightly reduced in relation to the value expected for trivalent cerium ions. No magnetic ordering is evident. -- Graphical Abstract: Packing of the polyhedra in the Ce{sub 7}Ni{sub 4.73}Ge{sub 3.27}In{sub 6} structure. Display Omitted

36 MATERIALS SCIENCE↗

Solvothermal synthesis of a bimetallic thiometallate containing germanium in two oxidation states

A new layered germanium-antimony sulphide, [Ge(C{sub 2}N{sub 2}H{sub 8}){sub 3}][GeSb{sub 2}S{sub 6}], has been prepared at 463 K under solvothermal conditions in the presence of ethylenediamine. The compound has been characterised by single-crystal X-ray diffraction, thermogravimetry, elemental analysis and reflectance spectroscopy. [Ge(C{sub 2}N{sub 2}H{sub 8}){sub 3}][GeSb{sub 2}S{sub 6}] crystallises in the space group Pbca (a=13.3284(5), b=17.4801(6), c=18.5447(7) A). The structure consists of cyclic [GeSb{sub 2}S{sub 8}]{sup 6-} units that form chains which are cross-linked through Sb{sub 2}S{sub 2} rings to generate layers of stoichiometry [GeSb{sub 2}S{sub 6}]{sup 2-}, between which [Ge(en){sub 3}]{sup 2+} cations are located. [Ge(C{sub 2}N{sub 2}H{sub 8}){sub 3}][GeSb{sub 2}S{sub 6}] contains germanium in both the divalent and tetravalent states. The optical band gap of 2.49(4) eV is in excellent agreement with the value expected on the basis of the correlation with the density of metal centres previously identified for thioantimonates, and is consistent with states at the top of the valence band being predominantly of sulphur 3p character. - Graphical abstract: [Ge(C{sub 2}N{sub 2}H{sub 8}){sub 3}][GeSb{sub 2}S{sub 6}] is a mixed valent germanium compound that contains [GeSb{sub 2}S{sub 8}]{sup 6-} units cross linked through Sb{sub 2}S{sub 2} units to generate layers. Highlights: Black-Right-Pointing-Pointer Preparation and structural characterisation of a new mixed-metal thiometallate. Black-Right-Pointing-Pointer Germanium present in two oxidation states. Black-Right-Pointing-Pointer Optical band gap of 2.49(4) eV. Black-Right-Pointing-Pointer Band gap conforms to a correlation between band gap and density of metal centres.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic behavior of the Bi{sub 2−y}Sr{sub y}Ir{sub 2}O{sub 7} pyrochlore solid solution

The temperature dependence of magnetic susceptibility of the Bi{sub 2−y}Sr{sub y}Ir{sub 2}O{sub 7} system was studied from 2 to 300 K. According to these measurements, the solid solution (0≤y≤0.9) does not show any magnetic transition; however, a noticeable deviation from the Curie–Weiss law occurs and the magnetic behavior of this system can be ascribed to short-range magnetic order that is also present in several geometrically frustrated systems. The Pauli magnetic susceptibility decreases as the Sr content increases, this can be associated with a shift towards Ir{sup 5+} in samples; also the Ir effective magnetic moment decreases. The estimated Wilson-ratio indicates the presence of strong electron–electron correlations. - Graphical abstract: Temperature dependence of the magnetic susceptibility of Bi{sub 2−y}Sr{sub y}Ir{sub 2}O{sub 7}. The samples of this system showed no magnetic transition down to 2 K. Analyzing magnetic data (symbols for experimental data, continuous line for the Curie–Weiss (CW) equation and black dots for a modified CW equation), it is found that this system departures from a CW-like equation and the magnetic parameters C and θ notably deviate from the expected values for Ir. Better fittings with a modified CW equation are shown in the A and B insets. Highlights: ► The magnetic susceptibility of the Bi{sub 2−x}Sr{sub x}Ir{sub 2}O{sub 7} system is discussed. ► No magnetic transition is observed. ► Magnetic measurements on the Bi{sub 2−y}Sr{sub y}Ir{sub 2}O{sub 7} indicate the existence of Ir{sup 5+}. ► The magnetic susceptibility does not follow a Curie–Weiss law. ► A modified Curie–Weiss equation describes correctly the magnetic susceptibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural and magnetic properties of RTiNO{sub 2} (R=Ce, Pr, Nd) perovskite nitride oxides

Neutron powder diffraction indicates that CeTiNO{sub 2} and PrTiNO{sub 2} crystallize with orthorhombic Pnma symmetry (Ce: a=5.5580(5), b=7.8369(7), and c=5.5830(4) Å; Pr: a=5.5468(5), b=7.8142(5), and c=5.5514(5) Å) as a result of a{sup –}b{sup +}a{sup –} tilting of the titanium-centered octahedra. Careful examination of the NPD data, confirms the absence of long range anion order in both compounds, while apparent superstructure reflections seen in electron diffraction patterns provide evidence for short range anion order. Inverse magnetic susceptibility plots reveal that the RTiNO{sub 2} (R=Ce, Pr, Nd) compounds are paramagnetic with Weiss constants that vary from −28 to −42 K. Effective magnetic moments for RTiNO{sub 2} (R=Ce, Pr, Nd) are 2.43 μ{sub B}, 3.63 μ{sub B}, and 3.47 μ{sub B}, respectively, in line with values expected for free rare-earth ions. Deviations from Curie–Weiss behavior that occur below 150 K for CeTiNO{sub 2} and below 30 K for NdTiNO{sub 2} are driven by magnetic anisotropy, spin–orbit coupling, and crystal field effects. - Graphical abstract: The structure and magnetism of the oxide nitride perovskites RTiNO{sub 2} (R=Ce, Pr, Nd) have been explored. The average symmetry is shown to be Pnma with a random distribution of oxide and nitride ions and a{sup −}b{sup +}a{sup −} tilting of the titanium-centered octahedra, but electron diffraction shows evidence for short range anion order. All three compounds are paramagnetic but deviations from the Curie Weiss law are seen below 150 K for R=Ce and below 30 K for R=Nd. - Highlights: • The oxide nitride perovskites RTiNO{sub 2} (R=Ce, Pr) have been prepared and their structures determined. • Diffraction measurements indicate short range cis-order of O and N, but no long range order. • Compounds are paramagnetic with Weiss constants that vary from −28 to −42 K. • CeTiO{sub 2}N and NdTiO{sub 2}N deviate from Curie–Weiss behavior below 150 and 30 K, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to planning target volume (PTV) margins for planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method of Best Representation for Averages in Data Evaluation

A new method for averaging data for which incomplete information is available is presented. For example, this method would be applicable during data evaluation where only the final outcomes of the experiments and the associated uncertainties are known. This method is based on using the measurements to construct a mean probability density for the data set. This “expected value method” (EVM) is designed to treat asymmetric uncertainties and has distinct advantages over other methods of averaging, including giving a more realistic uncertainty, being robust to outliers and consistent under various representations of the same quantity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗