Search NASA⌕ Search

SEARCH · Search NASA

Results for “Excel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution

Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~ 10 27 yr, requiring suppressing backgrounds to < 1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~ 5 when reconstructing electron-positron pairs in the 208Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~ 10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV e - e + pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic resonance elastography SE-EPI vs GRE sequences at 3T in a pediatric population with liver disease

Purpose: The goal of our study is to compare hepatic stiffness measures using gradient-recalled echo (GRE) versus spin-echo echo planar imaging (SE-EPI)-based MR Elastography (MRE) at 3T used to measure hepatic stiffness in a patients with suspected liver diseases. Materials and methods: This retrospective study included 52 patients with liver disease who underwent a 3T MRE exam including both an investigational SE-EPI-based technique and a product GRE-based technique. Regions of interest (ROI) were placed on the elastograms to measure elastography-derived liver stiffness as well as the area included within the ROIs. The mean liver stiffness values and area of ROIs were compared. Results: The mean liver stiffness was 3.72 kilopascal (kPa) ± 1.29 using GRE MRE and 3.78 kPa ± 1.13 using SE-EPI MRE. Measurement of liver stiffness showed excellent agreement between the two pulse sequences with a mean bias of − 0.1 kPa (range − 1.8 to 1.7 kPa) between sequences. The mean measurable ROI area was higher with SE-EPI (313.8 cm{sup 2} ± 213.8) than with the GRE technique (208.6 cm{sup 2} ± 114.8), and the difference was statistically significant (P < 0.05). Conclusions: Our data shows excellent agreement of measured liver stiffness between GRE and SE-EPI-based sequences at 3T. Our results show the advantage of a SE-EPI MRE sequence in terms of image quality, ROI size and acquisition time with equivalent liver stiffness measurements as compared to GRE-MRE sequence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interobserver agreement of computed tomography reporting standards for chronic pancreatitis

Aim: To assess the interobserver agreement of computed tomography (CT) reporting standards for chronic pancreatitis (CP). Subjects and methods: Retrospective analysis of CT of 47 patients (33 males and 11 females, age range 36 to 56 years) with CP who presented with abdominal pain (n = 41), steatorrhea (n = 37), and glucose intolerance (n = 31). The patients underwent CT study using a 16-multidetector CT scanner with a pancreatic protocol including a nonenhanced scan followed by pancreatic phase at 35 s and portal venous phase at 65 s after intravenous injection of nonionic contrast medium. Image analysis was performed by two radiologists according to reporting standards for CP. Results: There was excellent interobserver agreement (84.8 %) between the two reviewers in CT reporting standards for CP (K = 0.80, 95 % CI 0.75–0.85, P = 0.001). There was good interobserver agreement for pancreatic duct (PD) caliber (K = 0.71, 95 % CI 0.56–0.87, P = 0.001), PD contour (K = 0.76, 95 % CI 0.61–0.91, P = 0.001), PD stricture (K = 0.070, 95 % CI 0.53–0.88, P = 0.001), and distribution of findings (K = 0.69, 95 % CI 0.51–0.86, P = 0.001). There was excellent interobserver agreement for intraductal calculi (K = 0.84, 95 % CI 0.68–0.98, P = 0.001), pancreatic calcifications (K = 0.86, 95 % CI 0.84–0.98, P = 0.001), and pancreatic diameter (K = 0.87, 95 % CI 0.75–0.99, P = 0.001). Conclusion: CT reporting standards for CP is a reliable method for diagnosis of patients with CP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Cement Leakage After Vertebroplasty with a Non-Flat-Panel Angio Unit Compared to Multidetector Computed Tomography - An Ex Vivo Study

The purpose of this study was to investigate the detection of cement leakages after vertebroplasty using angiographic computed tomography (ACT) in a non-flat-panel angio unit compared to multidetector computed tomography (MDCT). Vertebroplasty was performed in 19 of 33 cadaver vertebrae (23 thoracic and 10 lumbar segments). In the angio suite, ACT (190{sup o}; 1.5{sup o} per image) was performed to obtain volumetric data. Another volumetric data set of the specimen was obtained by MDCT using a standard algorithm. Nine multiplanar reconstructions in standardized axial, coronal, and sagittal planes of every vertebra were generated from both data sets. Images were evaluated on the basis of a nominal scale with 18 criteria, comprising osseous properties (e.g., integrity of the end plate) and cement distribution (e.g., presence of intraspinal cement). MDCT images were regarded as gold standard and analyzed by two readers in a consensus mode. Rotational acquisitions were analyzed by six blinded readers. Results were correlated with the gold standard using Cohen's {kappa}-coefficient analysis. Furthermore, interobserver variability was calculated. Correlation with the gold standard ranged from no correlation (osseous margins of the neuroforamen, {kappa} = 0.008) to intermediate (trace of vertebroplasty canula; {kappa} = 0.615) for criteria referring to osseous morphology. However, there was an excellent correlation for those criteria referring to cement distribution, with {kappa} values ranging from 0.948 (paravertebral cement distribution) to 0.972 (intraspinal cement distribution). With a minimum of {kappa} = 0.768 ('good correlation') and a maximum of {kappa} = 0.91 ('excellent'), interobserver variability was low. In conclusion, ACT in an angio suite without a flat-panel detector depicts a cement leakage after vertebroplasty as well as MDCT. However, the method does not provide sufficient depiction of osseous morphology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical and Clinical Results After Percutaneous Angioplasty in Nonmedial Fibromuscular Dysplasia: Outcome After Endovascular Management of Unifocal Renal Artery Stenoses in 30 Patients

Although percutaneous transluminal renal angioplasty (PTRA) is associated with excellent results in medial fibromuscular dysplasia (FMD), the clinical and technical outcome in the less common nonmedial subtype of FMD is not clearly known. Angiographic PTRA results and clinical follow-up were documented, to report technical and clinical results in 30 patients with unifocal, nonmedial dysplastic stenoses. Balloon angioplasty was technically successful in only 65% of the lesions. Additional stenting, performed after PTRA failure in six patients, increased the initial technical success rate to 82%. Stenting was used in another lesion after restenosis, and long-term patency was achieved in only three of the seven stented lesions. Frequent restenoses and unusual complications were observed during follow-up. Stent fracture occurred in two cases. Overall, long-term clinical and technical successes were sustained in 70 and 76%, respectively. We conclude that nonmedial, unifocal renal artery dysplastic stenoses do not share the excellent prognosis of the medial type and that stenting should be avoided. Therefore, surgery should be considered in lesions remaining unresponsive to balloon dilatation, after a second PTRA attempt.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 {+-} 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Patient Skin Dose Evaluated Using Radiochromic Film and Dose Calculation Software

PurposeTo compare, in an interventional radiology setting, peak skin doses (PSDs) delivered as calculated using a dedicated software tool and as measured using radiochromic film. To assess the utility of this dose calculation software tool in routine clinical practice.Materials and MethodsFirst, radiochromic films were positioned on the examination table in the back of an adult anthropomorphic phantom to measure PSD, and X-ray examinations were simulated. Then, films were again positioned in the patient’s back for 59 thoracic or abdominopelvic endovascular interventions. The results obtained with the radiochromic films were taken as a reference and were statistically compared with those of the software.ResultsWith measured PSDs ranging from 100 to 7000 mGy, the median software–film difference was 8.5%. Lin’s concordance coefficient was 0.98 [0.97; 0.99] (p < 0.001), meaning that concordance was excellent between the two methods. For the films where PSD exceeded 1000 mGy, the median difference in the measured value was 8.7% [− 1.3; 21.1], with a maximum discrepancy of 34%. Lin’s concordance coefficient was 0.98 [0.96; 1] (p < 0.001), meaning that concordance was excellent between the two methods.ConclusionComparison between radiochromic films and the software tool showed that the software is a suitable tool for a simple and reliable estimation of PSD. The software seems to be a good alternative to films, whose use remains complex.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reynolds stress tensor measurements using magnetic resonance velocimetry: expansion of the dynamic measurement range and analysis of systematic measurement errors

This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.

42 ENGINEERING↗

Microbial electron uptake in microbial electrosynthesis: a mini-review

Abstract Microbial electron uptake (EU) is the biological capacity of microbes to accept electrons from electroconductive solid materials. EU has been leveraged for sustainable bioproduction strategies via microbial electrosynthesis (MES). MES often involves the reduction of carbon dioxide to multi-carbon molecules, with electrons derived from electrodes in a bioelectrochemical system. EU can be indirect or direct. Indirect EU-based MES uses electron mediators to transfer electrons to microbes. Although an excellent initial strategy, indirect EU requires higher electrical energy. In contrast, the direct supply of cathodic electrons to microbes (direct EU) is more sustainable and energy efficient. Nonetheless, low product formation due to low electron transfer rates during direct EU remains a major challenge. Compared to indirect EU, direct EU is less well-studied perhaps due to the more recent discovery of this microbial capability. This mini-review focuses on the recent advances and challenges of direct EU in relation to MES.

Biotechnology & Applied Microbiology↗

Morphology, structure, and chemistry of nanoclusters in a mechanically alloyed nanostructured ferritic steel

Nanostructured ferritic steels have excellent high temperature creep properties and radiation tolerance due to the presence of a high density of Ti-Y-O-enriched nanoclusters. The morphology of the nanoclusters is found to be consistent with a truncated rhombic dodecahedron defined by the {l_brace}100{r_brace} and {l_brace}110{r_brace} planes in the Fe matrix. The derived symmetry and the compositional information indicate that the nanoclusters are inconsistent with the cubic Y2Ti2O7 or the polymorphs of Y2TiO5 phase. Possible structural models are discussed.

36 MATERIALS SCIENCE↗

The Momentum Distribution of Liquid ⁴He

We report a high-resolution neutron Compton scattering study of liquid ⁴He under milli-Kelvin temperature control. To interpret the scattering data, we performed Quantum Monte Carlo calculations of the atomic momentum distribution and final state effects for the conditions of temperature and density considered in the experiment. There is excellent agreement between the observed scattering and ab initio calculations of its lineshape at all temperatures. We also used model fit functions to obtain from the scattering data empirical estimates of the average atomic kinetic energy and Bose condensate fraction. These quantities are also in excellent agreement with ab initio calculations. We conclude that contemporary Quantum Monte Carlo methods can furnish accurate predictions for the properties of Bose liquids, including the condensate fraction, close to the superfluid transition temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vegetable Oil Based Polyurethane Containing 1,2,3-Triazolium Functional Groups as Antimicrobial Wound Dressing

Preparation of antimicrobial polyurethane wound dressing membranes from a mixture of castor oil and a novel soybean oil-based polyol containing 1,2,3-triazolium rings (QTSBO) was described in this research. QTSBO was prepared through N-alkylation of 1,2,3-triazole functional soybean oil (TSBO) with methyl iodide, and TSBO was synthesized from an azidated soybean oil and propargyl alcohol through click reaction. The excellent tensile strength of these dressings under dry state and minimum deterioration of this property at fully hydrated state guaranteed the mechanical protection of wounds during the entire period of the healing process. The measured quantities of equilibrium water absorption and water vapor transmission rate for the optimized dressings confirmed the applicability of the selected formulations for the preservation of proper moist environment over low exuding wounds. The cyto-compatibility of dressings was verified by the excellent ability of the dressings to support the growth and proliferation of dermal fibroblasts. Due to the presence of 1,2,3-triazolium rings the dressing showed efficient antimicrobial activity against different bacterial and fungal stains. Therefore, these dressing could promote wound healing by preserving moist and hygienic environment over the wound bed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ex Situ MgB{sub 2} Superconducting Tape with Very High Critical Current Density by Using Low-Temperature Sintering Precursor Powders

Ex situ MgB{sub 2} is usually considered as with lower critical current density (J{sub c}) compared to the in situ one due to much worse inter-granular connectivity. In this work, we reported the fabrication of ex situ MgB{sub 2} superconducting tape without dopants using Monel as sheath materials and Nb as the barrier, which has an excellent J{sub c} of 705 A/mm{sup 2} at 4.2 K under 4 T, almost as same as the in situ MgB{sub 2} wires. Massive and high-quality precursor powders with small grain sizes and quite low oxygen content were sintered at relatively low temperature and short time, 580 {sup ∘}C for 3 h. The effects of heat-treatment conditions and tape thickness on the microstructure and J{sub c} of ex situ MgB{sub 2} tapes were discussed. The results suggested that the improvement of grains-connectivity was responsible to the excellent J{sub c} properties of ex situ MgB{sub 2} tape.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of the corrosion resistance of Fe-Al-Cr alloys in simulated low NOx environments

Due to their excellent corrosion resistance, iron aluminum alloys are currently being considered for use as weld claddings in fossil fuel fired power plants. The susceptibility to hydrogen cracking of these alloys at higher aluminum concentrations has led researchers to examine the effect of chromium additions on the corrosion resistance of lower aluminum alloys. In this work, three iron aluminum alloys were exposed to simulated coal combustion environments at 500 and 700{sup o}C for short (100 h) and long (5000 h) isothermal durations. Scanning electron microscopy was used to analyze the corrosion products. All alloys exhibited excellent corrosion resistance during short term exposures. For longer test times, increasing the aluminum concentration improved alloy corrosion resistance. The addition of chromium to the binary iron aluminum alloy prevented the formation iron sulfide and resulted in slower corrosion kinetics. A general classification of the scales developed on these alloys is presented.

20 FOSSIL-FUELED POWER PLANTS↗

Establishing Relationships Between the Geometric Structure and Chemical Reactivity of Alloy Catalysts Based on Their Measured Electronic Structure

While it is fairly straightforward to predict the relative chemical reactivity of pure metals, obtaining similar structure-performance relationships for alloys is more challenging. In this contribution we present experimental analysis supported with quantum chemical DFT calculations which allowed us to propose a simple, physically transparent model to predict the impact of alloying on the local electronic structure of different sites in alloys and on the local chemical reactivity. The model was developed through studies of a number of Pt alloys. The central feature of the model is that hybridization of d-orbitals in alloys does not lead to significant charge transfer between the constituent elements in the alloy, and therefore the width of the local density of d-states projected on a site, which is easily calculated from tabulated parameters, is an excellent descriptor of the chemical reactivity of the site.

36 MATERIALS SCIENCE↗

A new discovery of edge localized modes suppression using ICRH

Here, the high-confinement mode (H-mode) is very important for the fusion performance of ITER and future fusion reactors. The H-mode pedestal is a region featuring strongly reduced turbulence and transport just inside the limiting flux surface with strong plasma gradients, which drive edge localized modes (ELMs) in tokamaks. The ELMs, however, are quasiperiodic relaxations of the pedestal, resulting in a series of hot plasma eruptions similar to magnetospheric substorms, solar and stellar flares, which could potentially damage the ITER divertor plates and first walls. To mitigate and suppress the ELMs in H-mode plasmas, the fusion community has tried to develop effective actuators over the past two decades. Two separate excellent inventions have been awarded to recognize their achievements. The 2018 APS excellence award in Plasma Physics Research was given to Drs. Todd E. Evans, Max E. Fenstermacher, and Richard Alan Moyer for their first experimental demonstration of the stabilization of ELMs in high-confinement diverted discharges by application of very small edge-resonant magnetic perturbations, which led to the adoption of suppression coils in the ITER design. The 2018 Fusion Technology Award from the IEEE’s Nuclear and Plasma Science Society (NPSS) was given to Dr. Larry Baylor for his work designing the fueling, pumping and disruption mitigation system for the US ITER Project and for the implementation of pellet ELM mitigation for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-Situ Studies of Intercritically Austempered Ductile Iron Using Neutron Diffraction

Intercritically austempered ductile irons hold promise for applications requiring fatigue durability, excellent castability, low production energy requirements, reduced greenhouse gas emissions and excellent machinability. In the present study, four different ductile iron alloys, containing manganese and nickel as the primary austenite-stabilizing elements, were heat treated to obtain different quantities of austenite in the final microstructure. This paper reports the microstructures and phases present in these alloys. Further, lattice strains and diffraction elastic constants in various crystallographic directions and the transformation characteristics of the austenite as a function of applied stress were determined using in-situ loading with neutron diffraction at the second generation Neutron Residual Stress Facility (NRSF2) at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL).

36 MATERIALS SCIENCE↗

A Review of Permanent Magnet Stirring During Metal Solidification

Rather than using conventional electromagnetic stirring (EMS) with three-phase alternating current, permanent magnet stirring (PMS), based on the use of sintered NdFeB material which has excellent magnetic characteristics, can be employed to generate a magnetic field for the stirring of liquid metal during solidification. Recent experience with steel casting indicates that PMS requires less than 20 pct of the total energy compared with EMS. Despite the excellent magnetic density properties and low power consumption, this relatively new technology has received comparatively little attention by the metal casting community. This paper reviews simulation modeling, experimental studies, and industrial trials of PMS conducted during recent years. With the development of magnetic simulation software, the magnetic field and associated flow patterns generated by PMS have been evaluated. Based on the results obtained from laboratory experiments, the effects of PMS on metal solidification structures and typical defects such as surface pinholes and center cavities are summarized. The significance of findings obtained from trials of PMS within the metals processing sector, including the continuous casting of steel, are discussed with the aim of providing an overview of the relevant parameters that are of importance for further development and industrial application of this innovative technology.

36 MATERIALS SCIENCE↗