Search NASA⌕ Search

SEARCH · Search NASA

Results for “FINANCIAL MODEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

High yield production of 3-hydroxypropionic acid using Issatchenkia orientalis

Biomanufacturing provides a more sustainable alternative to fossil-based chemical manufacturing. 3-Hydroxypropionic acid (3HP) is a top Department of Energy value-added chemical and precursor to bioplastics, yet cost-effective microbial production remains elusive. Here, we establish the acid-tolerant yeast Issatchenkia orientalis as a robust host for low-pH 3HP biosynthesis. Genome-scale modeling identifies the β-alanine pathway as optimal, offering the highest theoretical yield and lowest oxygen requirement. Thermodynamic analysis confirms its favorability under acidic conditions. Using sequence similarity network analysis, we discover highly active aspartate 1-decarboxylase (PAND), β-alanine-pyruvate aminotransferase (BAPAT), and 3HP dehydrogenase (YDFG), which significantly improve the pathway efficiency. Next, to further elevate the production, pathway optimization through multi-copy PAND integration, byproduct elimination (knockouts of pyruvate decarboxylase and glycerol-3-phosphate dehydrogenase), and reinforcement of aspartate flux by overexpression of pyruvate carboxylase and aspartate amino transferase improves the titer to 29 g/L in shake flasks. Fed-batch fermentation at pH 4 with low-cost corn steep liquor medium further increases the production to 92 g/L with 0.7 g/g yield and 0.55 g/L/h productivity. Techno-economic analysis indicates that such performance could potentially enable a financially viable process for sustainable acrylic acid production. This work establishes I. orientalis as a next-generation platform for cost-effective 3HP production and paves the way toward industrial commercialization.

Biotechnology↗

DOE-NE LWRS Integrated Program Plan - Physical Security Pathway

Domestic nuclear power is facing increased financial pressures from a variety of areas and there is pressure on these utilities to reduce their cost of operation. Currently, about 20%-30% of all on-site personnel are related to physical security. The LWRS Program recognized that R&D related to physical security could play a role in providing nuclear utilities technical and staffing efficiency options to meet their physical security commitments, but utilities often lack the technical basis or the ability to create the technical basis to realize or implement these efficiencies; towards this end, the LWRS Program created the Physical Security Pathway in September 2019. The pathway performs R&D to develop methods, tools, and technologies to optimize and modernize a nuclear power facility’s security posture. The pathway will: (1) conduct research on risk-informed techniques for physical security that account for a dynamic adversary; (2) apply advanced modeling and simulation tools to better inform physical-security scenarios and reduce uncertainties in force-on-force modeling; (3) assess benefits from proposed enhancements and novel mitigation strategies and explore changes to best practices, guides, or regulation to enable modernization; and (4) enhance and provide the technical basis for stakeholders to employ new security methods, tools, and technologies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data for An End-to-End Pipeline for Succinic Acid Production at an Industrially Relevant Scale Using Issatchenkia orientalis

Microbial production of succinic acid (SA) at an industrially relevant scale has been hindered by high downstream processing costs arising from neutral pH fermentation for over three decades. Here, we metabolically engineer the acid-tolerant yeast Issatchenkia orientalis for SA production, attaining the highest titers in sugar-based media at low pH (pH 3) in fed-batch fermentations, i.e. 109.5 g/L in minimal medium and 104.6 g/L in sugarcane juice medium. We further perform batch fermentation using sugarcane juice medium in a pilot-scale fermenter (300×) and achieve 63.1 g/L of SA, which can be directly crystallized with a yield of 64.0%. Finally, we simulate an end-to-end low-pH SA production pipeline, and techno-economic analysis and life cycle assessment indicate our process is financially viable and can reduce greenhouse gas emissions by 34–90% relative to fossil-based production processes. We expect I. orientalis can serve as a general industrial platform for production of organic acids.

Metabolomics↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predicting the Effect of Single and Multiple Mutations on Protein Structural Stability

Predicting how a point mutation alters a protein’s stability can guide pharmaceutical drug design initiatives which aim to counter the effects of serious diseases. Conducting mutagenesis studies in physical proteins can give insights about the effects of amino acid substitutions, but such wet-lab work is prohibitive due to the time as well as financial resources needed to assess the effect of even a single amino acid substitution. Computational methods for predicting the effects of a mutation on a protein structure can complement wet-lab work, and varying approaches are available with promising accuracy rates. In this work we compare and assess the utility of several machine learning methods and their ability to predict the effects of single and double mutations. We in silico generate mutant protein structures, and compute several rigidity metrics for each of them. We use these as features for our Support Vector Regression (SVR), Random Forest (RF), and Deep Neural Network (DNN) methods. We validate the predictions of our in silico mutations against experimental ΔΔG stability data, and attain Pearson Correlation values upwards of 0.71 for single mutations, and 0.81 for double mutations. We perform ablation studies to assess which features contribute most to a model’s success, and also introduce a voting scheme to synthesize a single prediction from the individual predictions of the three models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

San Francisco Bar Pilot Fatigue Study

The purpose of this study was to evaluate the extent of fatigue among San Francisco Bar Pilots (Maritime Pilots) and its potential impact on safety, and to make recommendations concerning how the risk of fatigue could be managed. Information was gathered via a literature review, observations of Bar Pilots at work, surveys, a task analysis, and an analysis of dispatch records.The work of San Francisco Bar Pilots involves an unusual mix of activities and job demands. Their work calls for situational awareness, reasoning, communication, and perceptual abilities comparable to those required by airline pilots and air traffic controllers. Errors can have severe consequences for public safety and the environment, as well as significant financial costs. Fatigue is increasingly recognized as a hazard that must be managed by the transportation industry. The reduced sleep quality and quantity experienced by personnel who work at night, in conjunction with human circadian rhythms can lead to an operationally significant level of cognitive impairment. The cognitive impact of fatigue includes functions that are critical to safe maritime piloting, such as vigilance, judgment, reaction time and communication. The surveys distributed to Bar Pilots did not uncover evidence of widespread fatigue. The survey results also suggested that fatigue was not a major concern of Bar Pilots. Bar Pilots had overall low scores on the subjective fatigue measures used in the survey, and generally assessed the safety risk due to fatigue as low. Compared to air traffic controllers, Bar Pilots gave significantly lower ratings on questions concerning the prevalence and impact of fatigue. The application of fatigue modeling software to Bar Pilot dispatch records identified that in most cases, pilot's cognitive effectiveness was predicted to be acceptable during their duty periods. However, these results could not be verified with objective data.The study identified a number of fatigue issues that deserve attention. These include Bar Pilot work periods that frequently infringe on the circadian low, consecutive work periods without a significant break, consecutive periods of night work, unpredictable work schedules, start time variability, the potential for sleep inertia, and the number of pilots on the board at any given time.

fatigue↗

Temperature-responsive smart tracers for field-measurement of inter-well thermal evolution: Heterogeneous kinetics and field demonstration

Temperature-responsive smart tracers enable advanced warning of a “premature thermal breakthrough” and may therefore improve reservoir management and reduce financial risk. A successful calculation of inter-well fluid temperatures requires that temperature-dependent kinetics are known, which typically result from homogeneous batch reactor experiments. However, recent meso-scale field experiments at the Altona Field Laboratory involving fluid flow in a discretely-fractured reservoir suggest that silica-fluid interfaces may accelerate hydrolysis kinetics. Here, the Arrhenius parameters of phenyl acetate hydrolysis are investigated under heterogeneous reaction conditions in packed-bed column experiments. The breakthrough curve of the reaction product is compared to an inert reference tracer (carbon-cored nanoparticles). Temperatures experienced during field testing ranging from 10 to 40 °C were studied using a phosphate buffer solution to maintain a near-neutral pH, as found in the reservoir. The empirically-determined pre-exponential factor and activation energy values are subsequently used in a first-order kinetic model to improve calculations of effective reservoir temperatures for these meso-scale field tests. Here, the results suggest that hydrolysis reactions can directly monitor inter-well reservoir temperatures, but only if the influence of solid-fluid interactions are carefully accounted for.

15 GEOTHERMAL ENERGY↗

Opinion Dynamics on Networks under Correlated Disordered External Perturbations

We study an influence network of voters subjected to correlated disordered external perturbations, and solve the dynamical equations exactly for fully connected networks. The model has a critical phase transition between disordered unimodal and ordered bimodal distribution states, characterized by an increase in the vote-share variability of the equilibrium distributions. The fluctuations (variance and correlations) in the external perturbations are shown to reduce the impact of the external influence by increasing the critical threshold needed for the bimodal distribution of opinions to appear. The external fluctuations also have the surprising effect of driving voters towards biased opinions. Furthermore, the first and second moments of the external perturbations are shown to affect the first and second moments of the vote-share distribution. This is shown analytically in the mean field limit, and confirmed numerically for fully connected networks and other network topologies. Studying the dynamic response of complex systems to disordered external perturbations could help us understand the dynamics of a wide variety of networked systems, from social networks and financial markets to amorphous magnetic spins and population genetics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-31: Biodynamic Imaging of Cancer Tissue and Response to Chemotherapy

Purpose: To measure intracellular motions inside three-dimensional living cancer tissue samples to establish a novel set of biodynamic biomarkers that assess tissue proliferative activity and sensitivity or resistance to chemotherapy. Methods: Biodynamic imaging (BDI) uses digital holography with low-coherence low-intensity light illumination to construct 3D holograms from depths up to a millimeter deep inside cancer tissue models that include multicellular tumor spheroids and ex vivo cancer biopsies from canine non-Hodgkins lymphoma and epithelial ovarian cancer (EOC) mouse explants. Intracellular motions modulate the holographic intensity with frequencies related to the Doppler effect caused by the motions of a wide variety of intracellular components. These motions are affected by applied therapeutic agents, and BDI produces unique fingerprints of the action of specific drugs on the motions in specific cell types. In this study, chemotherapeutic agents (doxorubicin for canine lymphoma and oxoplatin for ovarian) are applied to the living tissue models and monitored over 10 hours by BDI. Results: Multicellular spheroids and patient biopsies are categorized as either sensitive or insensitive to applied therapeutics depending on the intracellular Doppler signatures of chemotherapy response. For both lymphoma and EOC there is strong specificity to the two types of sensitivities, with sensitive cell lines and biopsies exhibiting a global cessation of proliferation and strong suppression of metabolic activity, while insensitive cell lines and biopsies show moderate activation of Doppler frequencies associated with membrane processes and possible membrane trafficking. Conclusion: This work supports the hypothesis that biodynamic biomarkers from three-dimensional living tumor tissue, that includes tissue heterogeneity and measured within 24 hours of surgery, is predictive of near-term patient response to therapy. Future work will correlate biodynamic biomarkers with progression free survival times. This work is supported by NIH 1R01EB016582 and NSF 1263753-CBET. Nolte, Turek and An have a financial interest in Animated Dynamics, Inc. that will be licensing technology from Purdue University.

60 APPLIED LIFE SCIENCES↗

Methodology Description for the Policy Analysis Modeling System (PAMS)

The Policy Analysis Modeling System is a spreadsheet tool developed to provide an estimate of costs and benefits of appliance efficiency standard and labeling programs. PAMS is a self-contained spreadsheet model that provides both a consumer-oriented analysis and a national cost-benefit analysis in the style of the analysis performed for U.S. appliance efficiency standards. The tool allows policy analysts from many countries to produce a first-cut analysis of appliance efficiency program costs and benefits, examine the sensitivities of the analysis with respect to different policy parameters and assumptions, and continually refine the analysis as more data becomes available. The methodology is a bottom-up approach, using technical specifications for particular products in estimating the increased cost to the consumer resulting from implementation of particular energy-saving designs. It is designed to operate for the widest possible variety of countries, and with as little need as possible for detailed input data. For more accurate results, it can be easily customized to use the most reliable country-specific data inputs. In addition to consumer financial impacts, the tool provides national primary energy savings and estimates of carbon emissions mitigation resulting from the program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2023 SAGE-Camp Report

The 7 th Summer Physics Camp for Young Women was successfully held in person in 2023 from June 5 th to 16 th at the New Mexico School for the Arts in Santa Fe, NM at Hilo Intermediate School in Hawaii. This year’s camp was dedicated to the topic of Energy Security and was made possible thanks to the strong collaboration of Los Alamos, Sandia and Hawaii teams and the logistical and financial support of Los Alamos and Sandia National Laboratories, New Mexico Consortium, SAGE- Moore Foundation, LANL Foundation, ACS, IEE, APS four corners, N3B, Hawaii Museum of Science and Technology, New Mexico School for the Arts (NMSA) and Tech Source. The camp mobilized more than 120 volunteers who made the camp a success. The camp is free of charge to the students and included free lunch and snacks for the busy brains to have plenty of energy, also included all materials needed for the hands-on activities (like drone building, crystal structure, solar panels, wind turbine fabrication, soldering, coding etc) and also a stipend for students who attended for the full two weeks and for two educators and two student mentors in NM. The camp offered 32 high school students from New Mexico and 8 from Hawaii a unique opportunity to explore science topics and meet a broad range of role model professionals across STEM fields including astrophysics, cybersecurity, Energy fields, space science, engineering, biophysics, environmental science, robotics, computer science, nuclear engineering, radiological science, physics and chemistry. With nearly 120 volunteers who came mainly from Los Alamos National Laboratory (66%) and Sandia national laboratories (18%), two funded educators from NM, Dr. Weldon Beauchamp and Dr. Ellee Cook, and two educators from Hilo, Dr. Pascale Creek Pinner and LeAnn Ragasa, the camp was educationally sound and extremely varied. The collaboration with school educators is critical for the goal of this camp to not only impact students' lives but also improve STEM education in NM and Hawaii. The ultimate goal of the camp is to increase higher education aspirations of students, empower them to consider careers in STEM and learn more about the opportunities available to them in our local colleges and DOE National Laboratories. In addition, the camp also hired 2 past students as student mentors, Megan Odom and Elisea Jackson, who currently attend NMSA and were students at the camp in 2022 when it was virtual. The in-person camp which aims at empowering under-represented minorities in STEM in our community received more than 52 applications this year from all over NM and 8 applications from Hawaii. Our selection criteria are based on diversity, equity and inclusion, and students for whom the camp can be a life-changing opportunity are given a chance to attend the camp. During COVID, the camp was held virtually and gave the opportunity to students from remote areas in NM and Hawaii to attend from their homes. This year, fantastic families supported students everyday even when home was in remote areas in NM like Lea county, Sandoval county, Bernalillo or Mora county. The organizers hope next year they can offer a residential option for students from remote areas.

99 GENERAL AND MISCELLANEOUS↗

Fibrous Fillers to Manufacture Ultra High Ash/Performance Paper

The paper industry is one of the largest users of energy and emitters of CO2 in the US manufacturing industry. In addition to that, it is facing tremendous financial pressure due to lower cost imports. The fine paper industry has shrunk from 15 million tons per year production to 10 million tons per year in the last 5 years. This has resulted in mill closures and job loses. The AF&PA and the DOE formed a program called Agenda 2020 to help in funding to develop breakthrough technologies to provide help in meeting these challenges. The objectives of this project were to optimize and scale-up Fibrous Fillers technology, ready for commercial deployment and to develop ultra high ash/high performance paper using Fibrous Fillers. The goal was to reduce energy consumption, carbon footprint, and cost of manufacturing paper and related industries. GRI International (GRI) has been able to demonstrate the techno - economic feasibility and economic advantages of using its various products in both handsheets as well as in commercial paper mills. GRI has also been able to develop sophisticated models that demonstrate the effect of combinations of GRI's fillers at multiple filler levels. GRI has also been able to develop, optimize, and successfully scale-up new products for use in commercial paper mills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Documentation of the analysis of the benefits and costs of aeronautical research and technology models, volume 1

The analysis of the benefits and costs of aeronautical research and technology (ABC-ART) models are documented. These models were developed by NASA for use in analyzing the economic feasibility of applying advanced aeronautical technology to future civil aircraft. The methodology is composed of three major modules: fleet accounting module, airframe manufacturing module, and air carrier module. The fleet accounting module is used to estimate the number of new aircraft required as a function of time to meet demand. This estimation is based primarily upon the expected retirement age of existing aircraft and the expected change in revenue passenger miles demanded. Fuel consumption estimates are also generated by this module. The airframe manufacturer module is used to analyze the feasibility of the manufacturing the new aircraft demanded. The module includes logic for production scheduling and estimating manufacturing costs. For a series of aircraft selling prices, a cash flow analysis is performed and a rate of return on investment is calculated. The air carrier module provides a tool for analyzing the financial feasibility of an airline purchasing and operating the new aircraft. This module includes a methodology for computing the air carrier direct and indirect operating costs, performing a cash flow analysis, and estimating the internal rate of return on investment for a set of aircraft purchase prices.

Bobick, J. C.↗

Reducing the computational burden of a microgrid energy management system

As renewable technology advances and decreases in cost, microgrids are becoming an appealing means of distributed generation both for isolated communities and integrated with existing electrical grid systems. Due to their small size, however, microgrids may have financial limitations which preclude them from using commercial software to optimize control of their assets. Open-source optimization solvers are a viable alternative, but increase computation time. This work expands on a rolling horizon optimization framework for economic dispatch within an existing residential microgrid located in Hoover, Alabama. The microgrid has an open-source solver requirement and a need for quick solution time on a rolling horizon as opposed to a day-ahead commitment. We present a method of reducing integer variables by relaxation which completes two goals: reduction in computation time for real-time operations, and reduction in daily operational cost for the microgrid. Seasonal data for load and photovoltaic (PV) power was also collected from the microgrid to facilitate simulation testing. Computation time was successfully reduced using multiple variations of the relaxation method, while obtaining solution quality with operational cost similar to or better than the original model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Persistent and transient cost efficiency—an application to the Swiss hydropower sector

Electricity prices on the European market have decreased significantly over the past few years, resulting in a deterioration of Swiss hydropower firms’ competitiveness and profitability. One option to improve the sector’s competitiveness is to increase cost efficiency. The goal of this study is to quantify the level of persistent and transient cost efficiency of individual firms by applying the generalized true random effects (GTRE) model introduced by Colombi et al. (Journal of Productivity Analysis 42(2): 123–136, 2014) and Filippini and Greene (Journal of Productivity Analysis 45(2): 187–196, 2016). Applying this newly developed GTRE model to a total cost function, the level of cost efficiency of 65 Swiss hydropower firms is analyzed for the period between 2000 and 2013. A true random effects specification is estimated as a benchmark for the transient level of cost efficiency. The results show the presence of both transient as well as persistent cost inefficiencies. The GTREM predicts the aggregate level of cost inefficiency to amount to 21.8% (8.0% transient, 13.8% persistent) on average between 2000 and 2013. These two components differ in interpretation and implication. From an individual firm’s perspective, the two types of cost inefficiencies might require a firm’s management to respond with different improvement strategies. The existing level of persistent inefficiency could prevent the hydropower firms from adjusting their production processes to new market environments. From a regulatory point of view, the results of this study could be used in the scope and determination of the amount of financial support given to struggling firms.

13 HYDRO ENERGY↗

An open source GIS tool to quantify the visual impact of wind turbines and photovoltaic panels

Although there are clear economic and environmental incentives for producing energy from solar and wind power, there can be local opposition to their installation due to their impact upon the landscape. To date, no international guidelines exist to guide quantitative visual impact assessment of these facilities, making the planning process somewhat subjective. In this paper we demonstrate the development of a method and an Open Source GIS tool to quantitatively assess the visual impact of these facilities using line-of-site techniques. The methods here build upon previous studies by (i) more accurately representing the shape of energy producing facilities, (ii) taking into account the distortion of the perceived shape and size of facilities caused by the location of the observer, (iii) calculating the possible obscuring of facilities caused by terrain morphology and (iv) allowing the combination of various facilities to more accurately represent the landscape. The tool has been applied to real and synthetic case studies and compared to recently published results from other models, and demonstrates an improvement in accuracy of the calculated visual impact of facilities. The tool is named r.wind.sun and is freely available from GRASS GIS AddOns. - Highlights: • We develop a tool to quantify wind turbine and photovoltaic panel visual impact. • The tool is freely available to download and edit as a module of GRASS GIS. • The tool takes into account visual distortion of the shape and size of objects. • The accuracy of calculation of visual impact is improved over previous methods.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Lessons Learned From Incentives Programs for Efficient Air Conditioners: A Review

One of the largest drivers of growing global energy demand is the increasing market penetration of air conditioners (ACs). Global sales of room ACs were up 9% in 2013 compared to 2012, and that growth is expected to accelerate in coming decades, particularly in large metropolitan areas with hot climates. This report focuses on financial incentive programs that aim to mitigate the energy consumption attributable to the growing stock of ACs. Financial incentives leverage private investments to pull higher-efficiency technologies into the market. Through detailed case studies of AC energy-efficiency incentive programs, we show the significance and diversity of these programs and describe and share lessons learned from their design and implementation. The report also describes how incentive programs can be designed to address other pressing concerns related to growing AC use, such as challenges to power supply reliability resulting from increased peak demand and the global warming potential (GWP) of AC refrigerants. For policy makers and program administrators interested in addressing AC energy efficiency through incentive schemes, the report provides examples of past and present programs and highlights challenges that need to be considered when making program design and implementation decisions. The report begins with an overview of AC markets, highlighting their growth and savings potential, recent achievements from minimum energy performance standards, and typical barriers to the penetration of more efficient AC models. Next, we examine six AC incentive programs in depth, based on evaluation reports and/or interviews with program administrators. Finally, we outline program design features that could a) increase penetration of energy-efficient ACs, b) increase utility and customer participation in demand response programs targeted at reducing peak-load impacts, and c) phase out the use of high-GWP refrigerants in ACs. We find that incentive programs are particularly effective when they target emerging technologies that have still a low penetration in the market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗