Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Optical Measurement of Mass Flow of a Two-Phase Fluid

An optoelectronic system utilizes wavelength-dependent scattering of light for measuring the density and mass flow of a two-phase fluid in a pipe. The apparatus was invented for original use in measuring the mass flow of a two-phase cryogenic fluid (e.g., liquid hydrogen containing bubbles of hydrogen gas), but underlying principles of operation can readily be adapted to non-cryogenic two-phase fluids. The system (see figure) includes a laser module, which contains two or more laser diodes, each operating at a different wavelength. The laser module also contains beam splitters that combine the beams at the various wavelengths so as to produce two output beams, each containing all of the wavelengths. One of the multiwavelength output beams is sent, via a multimode fiberoptic cable, to a transmitting optical coupler. The other multiwavelength output beam is sent, via another multimode fiber-optic cable, to a reference detector module, wherein fiber-optic splitters split the light into several multiwavelength beams, each going to a photodiode having a spectral response that is known and that differs from the spectral responses of the other photodiodes. The outputs of these photodiodes are digitized and fed to a processor, which executes an algorithm that utilizes the known spectral responses to convert the photodiode outputs to obtain reference laser-power levels for the various wavelengths. The transmitting optical coupler is mounted in (and sealed to) a hole in the pipe and is oriented at a slant with respect to the axis of the pipe. The transmitting optical coupler contains a collimating lens and a cylindrical lens that form the light emerging from the end of the fiber-optic cable into a fan-shaped beam in a meridional plane of the pipe. Receiving optical couplers similar to the transmitting optical couplers are mounted in the same meridional plane at various longitudinal positions on the opposite side of the pipe, approximately facing the transmitting optical coupler along the same slant. Light collected by each receiving optical coupler is sent, via a multimode fiber-optic cable, to a detector module similar to the reference detector module. The outputs of the photodiodes in each detector module are digitized and processed, similarly to those of the reference detector module, to obtain indications of the amounts of light of each wavelength scattered to the corresponding receiving position. The value for each wavelength at each position is also normalized to the reference laser-power level for that wavelength. From these normalized values, the density and the mass flow rate of the fluid are estimated.

Wiley, John↗

Method and Apparatus for Predicting Unsteady Pressure and Flow Rate Distribution in a Fluid Network

A method and apparatus for analyzing steady state and transient flow in a complex fluid network, modeling phase changes, compressibility, mixture thermodynamics, external body forces such as gravity and centrifugal force and conjugate heat transfer. In some embodiments, a graphical user interface provides for the interactive development of a fluid network simulation having nodes and branches. In some embodiments, mass, energy, and specific conservation equations are solved at the nodes, and momentum conservation equations are solved in the branches. In some embodiments, contained herein are data objects for computing thermodynamic and thermophysical properties for fluids. In some embodiments, the systems of equations describing the fluid network are solved by a hybrid numerical method that is a combination of the Newton-Raphson and successive substitution methods.

Majumdar, Alok K.↗

System and Method for Wirelessly Determining Fluid Volume

A system and method are provided for determining the volume of a fluid in container. Sensors are positioned at distinct locations in a container of a fluid. Each sensor is sensitive to an interface defined by the top surface of the fluid. Interfaces associated with at least three of the sensors are determined and used to find the volume of the fluid in the container in a geometric process.

Woodard, Stanley E.↗

Method of calibrating a fluid-level measurement system

A method of calibrating a fluid-level measurement system is provided. A first response of the system is recorded when the system's sensor(s) is (are) not in contact with a fluid of interest. A second response of the system is recorded when the system's sensor(s) is (are) fully immersed in the fluid of interest. Using the first and second responses, a plurality of expected responses of the system's sensor(s) is (are) generated for a corresponding plurality of levels of immersion of the sensor(s) in the fluid of interest.

Woodard, Stanley E.↗

Fluid Interfaces of Triangular Containers in Reduced Gravity Environments

Capillary dominated fluid dynamics will be examined in a reduced-gravity environment onboard the KC-135; in particular, the behavior of the lower portion of the meniscus in triangular tank geometries. Seven clear acrylic tanks were constructed to view seven angles of the four geometries. Silicon oil with two different viscosities, 2cs and 5cs silicon oil, were used on different days of the flight. Six tanks and one control tank are filled with a certain viscosity fluid for each flight day. During each parabola, three tanks are tested at time. The experimental tanks are exchanged between parabola sets on the KC-135. The 60deg -60deg -60deg control tank is viewed throughout the flight. To gather data, two digital video cameras and one digital still camera are placed perpendicular the viewing surface. To provide a greater contrast in the meniscus, an EL backlighting sheet was used to backlight the tanks. These images and video are then digitized, passed through NASA's mini-tracker software, and compared to a theory published my M. M. Weislogel, "Fluid Interface Phenomena in a Low-Gravity Environment: Recent Results from Drop Tower Experimentation." By focusing on a lower portion of the meniscus and using longer periods of reduced gravity, this experiment may confirm that a stationary point exists on the fluid surface. This information will enable better designing of propellant management devices, especially satellite propellant refilling and gas venting. Also, biological and material processing systems in reduced gravity environments will benefit from this data.

Guttromson, Jayleen↗

Non-Toxic, Low-Freezing, Drop-In Replacement Heat Transfer Fluids

A non-toxic, non-flammable, low-freezing heat transfer fluid is being developed for drop-in replacement within current and future heat transfer loops currently using water or alcohol-based coolants. Numerous water-soluble compounds were down-selected and screened for toxicological, physical, chemical, compatibility, thermodynamic, and heat transfer properties. Two fluids were developed, one with a freezing point near 0 C, and one with a suppressed freezing point. Both fluids contain an additive package to improve material compatibility and microbial resistance. The optimized sub-zero solution had a freezing point of 30 C, and a freezing volume expansion of 10-percent of water. The toxicity of the solutions was experimentally determined as LD(50) greater than 5g/kg. The solutions were found to produce minimal corrosion with materials identified by NASA as potentially existing in secondary cooling loops. Thermal/hydrodynamic performance exceeded that of glycol-based fluids with comparable freezing points for temperatures Tf greater than 20 C. The additive package was demonstrated as a buffering agent to compensate for CO2 absorption, and to prevent microbial growth. The optimized solutions were determined to have physically/chemically stable shelf lives for freeze/thaw cycles and longterm test loop tests.

Cutbirth, J. Michael↗

Portable Intravenous Fluid Production Device for Ground Use

There are several medical conditions that require intravenous (IV) fluids. Limitations of mass, volume, storage space, shelf-life, transportation, and local resources can restrict the availability of such important fluids. These limitations are expected in long-duration space exploration missions and in remote or austere environments on Earth. Current IV fluid production requires large factory-based processes. Easy, portable, on-site production of IV fluids can eliminate these limitations. Based on experience gained in developing a device for spaceflight, a ground-use device was developed. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endotoxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (.25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters.

Scarpa, Philip J.↗

The Direction of Fluid Dynamics for Liquid Propulsion at NASA Marshall Space Flight Center

Marshall Space Flight Center (MSFC) is the National Aeronautics and Space Administration (NASA)-designated center for the development of space launch systems. MSFC is particularly known for propulsion system development. Many engineering skills and technical disciplines are needed to accomplish this mission. This presentation will focus on the work of the Fluid Dynamics Branch (ER42). ER42 resides in the Propulsion Systems Department at MSFC. The branch is responsible for all aspects of the discipline of fluid dynamics applied to propulsion or propulsion-induced loads and environments. This work begins with design trades and parametric studies, and continues through development, risk assessment, anomaly investigation and resolution, and failure investigations. Applications include the propellant delivery system including the main propulsion system (MPS) and turbomachinery; combustion devices for liquid engines and solid rocket motors; coupled systems; and launch environments. An advantage of the branch is that it is neither analysis nor test centric, but discipline centric. Fluid dynamics assessments are made by analysis, from lumped parameter modeling through unsteady computational fluid dynamics (CFD); testing, which can be cold flow or hot fire; or a combination of analysis and testing. Integration of all discipline methods into one branch enables efficient and accurate support to the projects. To accomplish this work, the branch currently employs approximately fifty engineers divided into four teams -- Propellant Delivery CFD, Combustion Driven Flows CFD, Unsteady and Experimental Flows, and Acoustics and Stability. This discussion will highlight some of the work performed in the branch and the direction in which the branch is headed.

Griffin, Lisa W.↗

Individual Differences in the Temporal Profile of Cardiovascular Responses to Head Down Tilt and Orthostatic Stress with and Without Fluid Loading

Susceptibility of healthy astronauts to orthostatic hypotension and presyncope is exacerbated upon return from spaceflight. Hypo-volemia is suspected to play an important role in cardiovascular deconditioning following exposure to spaceflight, which may lead to increased peripheral resistance, attenuated arterial baroreflex, and changes in cardiac function. The effect of altered gravity during space flight and planetary transition on human cardiovascular function is of critical importance to maintenance of astronaut health and safety. A promising countermeasure for post-flight orthostatic intolerance is fluid loading used to restore loss fluid volume by giving crew salt tablets and water prior to re-entry. Eight men and eight women will be tested during two, 6-hour exposures to 6o HDT: 1) fluid loading, 2) no fluid loading. Before and immediately after each HDT, subjects will perform a stand test to assess their orthostatic tolerance. Physiological measures (e.g., ECG, blood pressure, peripheral blood volume) will be continuously monitored while echocardiography measures are recorded at 30-minute intervals during HDT and stand tests. Preliminary results (N=4) clearly show individual differences in responses to this countermeasure and the time course of physiological changes induced by HDT.

Cowings, Patricia↗

Fluid Shifts Before, During, and After Prolonged Space Flight and their Association with Intracranial Pressure and Visual Impairment

With the conclusion of the Space Shuttle program, NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed in Space Shuttle crewmembers after their short-duration missions were largely transient, but more than 30% of ISS astronauts experience more profound changes in vision, some with objective structural and functional findings such as papilledema and choroidal folds on ophthalmologic examination. Globe flattening, optic nerve sheath dilatation, optic nerve tortuosity, and other findings have been noted in imaging studies. This pattern is referred to as visual impairment and intracranial pressure (VIIP) syndrome. The VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) is associated with the space flight-induced cephalad fluid shifts, but this hypothesis has not been systematically tested. The purpose of this study is to objectively characterize the fluid distribution and compartmentalization associated with long-duration space flight, and to correlate the findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during space flight, as well as the VIIP-related effects of those shifts, can be predicted by crewmember baseline data and responses to acute hemodynamic manipulations (such as head-down tilt tests) obtained before flight. Lastly, we will evaluate the patterns of fluid distribution in astronaut subjects on the ISS during the use of lower body negative pressure (LBNP) and respiratory maneuvers to characterize and explain general and individual responses during space flight.

Stenger, M.↗

Facial Soft Tissue Measurement in Microgravity-induces Fluid Shifts

Fluid shifts are a well‐known phenomenon in microgravity, and one result is facial edema. Objective measurement of tissue thickness in a standardized location could provide a correlate with the severity of the fluid shift. Previous studies of forehead tissue thickness (TTf) suggest that when exposed to environments that cause fluid shifts, including hypergravity, head‐down tilt, and high‐altitude/lowpressure, TTf changes in a consistent and measurable fashion. However, the technique in past studies is not well described or standardized. The International Space Station (ISS) houses an ultrasound (US) system capable of accurate sub‐millimeter measurements of TTf. We undertook to measure TTf during long‐duration space flight using a new accurate, repeatable and transferable technique. Methods: In‐flight and post‐flight B‐mode ultrasound images of a single astronaut's facial soft tissues were obtained using a Vivid‐q US system with a 12L‐RS high‐frequency linear array probe (General Electric, USA). Strictly mid‐sagittal images were obtained involving the lower frontal bone, the nasofrontal angle, and the osseo‐cartilaginous junction below. Single images were chosen for comparison that contained identical views of the bony landmarks and identical acoustical interface between the probe and skin. Using Gingko CADx DICOM viewing software, soft tissue thickness was measured at a right angle to the most prominent point of the inferior frontal bone to the epidermis. Four independent thickness measurements were made. Conclusions: Forehead tissue thickness measurement by ultrasound in microgravity is feasible, and our data suggest a decrease in tissue thickness upon return from microgravity environment, which is likely related to the cessation of fluid shifts. Further study is warranted to standardize the technique with regard to the individual variability of the local anatomy in this area.

Marshburn, Thomas↗

Star-Shaped Fluid Flow Tool for Use in Making Differential Measurements

A fluid flow tool's plate-like structure has a ring portion defining a flow hole, a support portion extending radially away from the ring portion and adapted to be coupled to conduit wall, and extensions extending radially away from the ring portion such that a periphery of the plate-like structure is defined by the extensions and trough regions between adjacent extensions. One or more ports formed in the ring portion are in fluid communication with the flow hole. A first manifold in the plate-like structure is in fluid communication with each port communicating with the flow hole. One or more ports are formed in the periphery of the plate-like structure. A second manifold in the plate-like structure is in fluid communication with each port formed in the periphery. The first and second manifolds extend through the plate-like structure to terminate and be accessible at the conduit wall.

England, John Dwight↗

Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions

Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.

thermal controls↗

ISS-CREAM Thermal and Fluid System Design and Analysis

Thermal and Fluids Analysis Workshop (TFAWS), Silver Spring MD NCTS 21070-15. The ISS-CREAM (Cosmic Ray Energetics And Mass for the International Space Station) payload is being developed by an international team and will provide significant cosmic ray characterization over a long time frame. Cold fluid provided by the ISS Exposed Facility (EF) is the primary means of cooling for 5 science instruments and over 7 electronics boxes. Thermal fluid integrated design and analysis was performed for CREAM using a Thermal Desktop model. This presentation will provide some specific design and modeling examples from the fluid cooling system, complex SCD (Silicon Charge Detector) and calorimeter hardware, and integrated payload and ISS level modeling. Features of Thermal Desktop such as CAD simplification, meshing of complex hardware, External References (Xrefs), and FloCAD modeling will be discussed.

Thermal analysis↗

Validation of a Cephalad Fluid Shift Countermeasure

INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.

Macias, B.↗

Application of Scanning-Imaging X-Ray Microscopy to Fluid Inclusion Candidates in Carbonates of Carbonaceous Chondrites

In order to search for such fluid inclusions in carbonaceous chondrites, a nondestructive technique using x-ray micro-absorption tomography combined with FIB sampling was developed and applied to a carbonaceous chondrite. They found fluid inclusion candidates in calcite grains, which were formed by aqueous alteration. However, they could not determine whether they are really aqueous fluids or merely voids. Phase and absorption contrast images can be simultaneously obtained in 3D by using scanning-imaging x-ray microscopy (SIXM). In refractive index, n=1-sigma+i(beta), in the real part, 1-sigma is the refractive index with decrement, sigma, which is nearly proportional to the density, and the imaginary part, beta, is the extinction coefficient, which is related to the liner attenuation coefficient, mu. Many phases, including water and organic materials as well as minerals, can be identified by SIXM, and this technique has potential availability for Hayabusa-2 sample analysis too. In this study, we examined quantitative performance of d and m values and the spatial resolution in SIXM by using standard materials, and applied this technique to carbonaceous chondrite samples. We used POM ([CH2O]n), silicon, quartz, forsterite, corundum, magnetite and nickel as standard materials for examining the sigma and mu values. A fluid inclusion in terrestrial quartz and bi-valve shell (Atrina vexillum), which are composed of calcite and organic layers with different thickness, were also used for examining the spatial resolution. The Ivuna (CI) and Sutter's Mill (CM) meteorites were used as carbonaceous chondrite samples. Rod- or cube-shaped samples 20-30 micron in size were extracted by using FIB from cross-sectional surfaces of the standard materials or polished thin sections of the chondrites, which was previously observed with SEM. Then, the sample was attached to a thin W-needle and imaged by SIXM system at beamline BL47XU, SPring-8, Japan. The slice thickness was 109.3 nm and the pixel size was mostly 100 nm.

Tsuchiyama, Akira↗

FluidCam 1 & 2 - UAV-based Fluid Lensing Instruments for High-Resolution 3D Subaqueous Imaging and Automated Remote Biosphere Assessment of Reef Ecosystems

We present NASA ESTO FluidCam 1 & 2, Visible and NIR Fluid-Lensing-enabled imaging payloads for Unmanned Aerial Vehicles (UAVs). Developed as part of a focused 2014 earth science technology grant, FluidCam 1&2 are Fluid-Lensing-based computational optical imagers designed for automated 3D mapping and remote sensing of underwater coastal targets from airborne platforms. Fluid Lensing has been used to map underwater reefs in 3D in American Samoa and Hamelin Pool, Australia from UAV platforms at sub-cm scale, which has proven a valuable tool in modern marine research for marine biosphere assessment and conservation. We share FluidCam 1&2 instrument validation and testing results as well as preliminary processed data from field campaigns. Petabyte-scale aerial survey efforts using Fluid Lensing to image at-risk reefs demonstrate broad applicability to large-scale automated species identification, morphology studies and reef ecosystem characterization for shallow marine environments and terrestrial biospheres, of crucial importance to improving bathymetry data for physical oceanographic models and understanding climate change’s impact on coastal zones, global oxygen production, carbon sequestration.

Chirayath, Ved↗

Fully-Coupled Fluid-Structure Interaction Simulations of a Supersonic Parachute

A validated computational fluid-structure interaction method for simulating the complex interaction between the large deformation of very thin, highly deformable structures and compressible flows is extended to consider large-scale problems in supersonic flows using parallel computing. The coupled fluid-structure interaction system is solved in a partitioned, or weakly-coupled, manner. The foundations of the applied fluid-structure interaction method are a higher-order, block-structured Cartesian, sharp immersed boundary method for the compressible Navier-Stokes equations and a computational structural dynamics solver employing a geometrically nonlinear 3-node shell element based on the mixed interpolation of tensorial components formulation. The method is applied to large deformation fluid-structure interaction validation cases before being applied to the inflation of a supersonic parachute in the upper Martian atmosphere where the goal is to demonstrate the capabilities of the solver when considering large-scale problems in supersonic flows.

Boustani, Jonathan↗