At least 775 records · Page 43

Monitoring, Controlling and Safeguarding Radiochemical Streams at Spent Fuel Reprocessing Facilities, Part 1: Optical Spectroscopic Methods

Abstract: The International Atomic Energy Agency (IAEA) has established international safeguards standards for fissionable material at spent fuel reprocessing plants to ensure that significant quantities of weapons-useable nuclear material are not diverted from these facilities. For large throughput nuclear facilities, it is difficult to satisfy the IAEA safeguards accountancy goal for detection of abrupt diversion. Currently, methods to verify material control and accountancy (MC&A) at these facilities require time-consuming and resource-intensive destructive assay (DA). Leveraging new on-line non-destructive assay (NDA) process monitoring techniques in conjunction with the traditional and highly precise DA methods may provide an additional measure to nuclear material accountancy which would potentially result in a more timely, cost-effective and resource efficient means for safeguards verification at such facilities. By monitoring process control measurements (e.g. flowrates, temperatures, or concentrations of reagents, products or wastes), abnormal plant operations can be detected. Pacific Northwest National Laboratory (PNNL) is developing on-line NDA process monitoring technologies based upon gamma-ray and optical spectroscopic measurements to potentially reduce the time and resource burden associated with current techniques. The Multi-Isotope Process (MIP) Monitor uses gamma spectroscopy and multivariate analysis to identify off-normal conditions in process streams. The spectroscopic monitor continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major stable flowsheet reagents using UV-Vis, Near IR and Raman spectroscopy. Multi-variate analysis is also applied to the optical measurements in order to quantify concentrations of analytes of interest within a complex array of radiochemical streams. This paper will provide an overview of these methods and reports on-going efforts to develop and demonstrate the technologies. This paper is Part 1 of a two part series, and focuses on the optical spectroscopy based process monitoring methods.

material control and accountancy, process monitor,↗

Monitoring, Controlling and Safeguarding Radiochemical Streams at Spent Fuel Reprocessing Facilities, Part 2: Gamma-Ray Spectroscopic Methods

The International Atomic Energy Agency (IAEA) has established international safeguards standards for fissionable material at spent fuel reprocessing plants to ensure that significant quantities of weapons-useable nuclear material are not diverted from these facilities. For large throughput nuclear facilities, it is difficult to satisfy the IAEA safeguards accountancy goal for detection of abrupt diversion. Currently, methods to verify material control and accountancy (MC&A) at these facilities require time-consuming and resource-intensive destructive assay (DA). Leveraging new on-line non-destructive assay (NDA) process monitoring techniques in conjunction with the traditional and highly precise DA methods may provide an additional measure to nuclear material accountancy which would potentially result in a more timely, cost-effective and resource efficient means for safeguards verification at such facilities. By monitoring process control measurements (e.g. flowrates, temperatures, or concentrations of reagents, products or wastes), abnormal plant operations can be detected. Pacific Northwest National Laboratory (PNNL) is developing on-line NDA process monitoring technologies based upon gamma-ray and optical spectroscopic measurements to potentially reduce the time and resource burden associated with current techniques. The Multi-Isotope Process (MIP) Monitor uses gamma spectroscopy and multivariate analysis to identify off-normal conditions in process streams. The spectroscopic monitor continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major stable flowsheet reagents using UV-Vis, Near IR and Raman spectroscopy. Multi-variate analysis is also applied to the optical measurements in order to quantify concentrations of analytes of interest within a complex array of radiochemical streams. This paper will provide an overview of these methods and reports on-going efforts to develop and demonstrate the technologies. This paper is Part 2 of a two part series, and focuses on the gamma spectroscopy based, Multi-Isotope Process (MIP) Monitor method.

Schwantes, Jon M↗

Evaluating Stage Motion for Automated Electron Microscopy

Abstract Precise control is an essential and elusive quality of emerging self-driving transmission electron microscopes (TEMs). It is widely understood these instruments must be capable of performing rapid, high-volume, and arbitrary movements for practical self-driving operation. However, stage movements are difficult to automate at scale, owing to mechanical instability, hysteresis, and thermal drift. Such difficulties pose major barriers to artificial intelligence-directed microscope designs that require repeatable, precise movements. To guide design of emerging instruments, it is necessary to understand the behavior of existing mechanisms to identify rate limiting steps for full autonomy. Here, we describe a general framework to evaluate stage motion in any TEM. We define metrics to evaluate stage degrees of freedom, propose solutions to improve performance, and comment on fundamental limits to automated experimentation using present hardware.

47 OTHER INSTRUMENTATION↗

Out of the Lab: 3D Printing on Non-Ideal Surfaces

In this work, coaxial direct ink writing is utilized to print sensitive or encapsulated materials onto heterogeneous and rough substrates. By enclosing the core fluid within a rigid ceramic shell, continuity is maintained even when printing on substrates traditionally considered challenging. This work presents the development of a coaxial ceramic direct ink writing system and investigates co-flow dynamics through microfluidic principles. A specially designed coaxial nozzle enables the co-extrusion of an alumina shell, with indium-tin-oxide inks serving as the core material. This approach allows the fabrication of core-shell ceramic structures suitable for future high-temperature applications on rough surfaces. The colloidal inks are tailored to achieve the necessary rheological properties and sintering performance. Additionally, flow simulations, guided by microfluidic co-flow principles, are employed to define the processing parameters for coaxial printing, ensuring precise control over the core-shell architectures. Physical modeling is further applied to study core deformation and eccentricity. These simulations are experimentally validated, supporting the successful deposition of coaxial ceramic features on heterogeneous, high-temperature ceramic substrates.

20 FOSSIL-FUELED POWER PLANTS↗

Measurement and Characterization of Helicopter Noise in Steady-State and Maneuvering Flight

A special acoustic flight test program was performed on the Bell 206B helicopter outfitted with an in-flight microphone boom/array attached to the helicopter while simultaneous acoustic measurements were made using a linear ground array of microphones arranged to be perpendicular to the flight path. Air and ground noise measurements were made in steady-state longitudinal and steady turning flight, and during selected dynamic maneuvers. Special instrumentation, including direct measurement of the helicopter s longitudinal tip-path-plane (TPP) angle, Differential Global Positioning System (DGPS) and Inertial Navigation Unit (INU) measurements, and a pursuit guidance display were used to measure important noise controlling parameters and to make the task of flying precise operating conditions and flight track easier for the pilot. Special care was also made to test only in very low winds. The resulting acoustic data is of relatively high quality and shows the value of carefully monitoring and controlling the helicopter s performance state. This paper has shown experimentally, that microphones close to the helicopter can be used to estimate the specific noise sources that radiate to the far field, if the microphones are positioned correctly relative to the noise source. Directivity patterns for steady, turning flight were also developed, for the first time, and connected to the turning performance of the helicopter. Some of the acoustic benefits of combining normally separated flight segments (i.e. an accelerated segment and a descending segment) were also demonstrated.

Schmitz, Fredric H.↗

Dispersed Fringe Sensing Analysis - DFSA

Dispersed Fringe Sensing (DFS) is a technique for measuring and phasing segmented telescope mirrors using a dispersed broadband light image. DFS is capable of breaking the monochromatic light ambiguity, measuring absolute piston errors between segments of large segmented primary mirrors to tens of nanometers accuracy over a range of 100 micrometers or more. The DFSA software tool analyzes DFS images to extract DFS encoded segment piston errors, which can be used to measure piston distances between primary mirror segments of ground and space telescopes. This information is necessary to control mirror segments to establish a smooth, continuous primary figure needed to achieve high optical quality. The DFSA tool is versatile, allowing precise piston measurements from a variety of different optical configurations. DFSA technology may be used for measuring wavefront pistons from sub-apertures defined by adjacent segments (such as Keck Telescope), or from separated sub-apertures used for testing large optical systems (such as sub-aperture wavefront testing for large primary mirrors using auto-collimating flats). An experimental demonstration of the coarse-phasing technology with verification of DFSA was performed at the Keck Telescope. DFSA includes image processing, wavelength and source spectral calibration, fringe extraction line determination, dispersed fringe analysis, and wavefront piston sign determination. The code is robust against internal optical system aberrations and against spectral variations of the source. In addition to the DFSA tool, the software package contains a simple but sophisticated MATLAB model to generate dispersed fringe images of optical system configurations in order to quickly estimate the coarse phasing performance given the optical and operational design requirements. Combining MATLAB (a high-level language and interactive environment developed by MathWorks), MACOS (JPL s software package for Modeling and Analysis for Controlled Optical Systems), and DFSA provides a unique optical development, modeling and analysis package to study current and future approaches to coarse phasing controlled segmented optical systems.

Sigrist, Norbert↗

Absolute x-ray energy calibration and monitoring using a diffraction-based method

In this paper, we report some recent developments of the diffraction-based absolute X-ray energy calibration method. In this calibration method, high spatial resolution of the measured detector offset is essential. To this end, a remotely controlled long-translation motorized stage was employed instead of the less convenient gauge blocks. It is found that the precision of absolute X-ray energy calibration (ΔE/E) is readily achieved down to the level of 10{sup −4} for high-energy monochromatic X-rays (e.g. 80 keV). Examples of applications to pair distribution function (PDF) measurements and energy monitoring for high-energy X-rays are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrochemically Controlled Atom by Atom Deposition of Gold to Polyaniline

Plyaniline (PANI) has been shown to be an effective matrix for hosting metal nanoclusters. In the case of gold, the tetrachloroaurate anion (AuCl₄) has a high affinity for the imine sites of polyaniline. Upon contract with PANI, AuCl₄ is spontaneously reduced to metallic gold, but the size of the formed Au clusters can not be precisely controlled. Herein, we report on electrochemical method of controlled deposition of one atom by one atom of gold per one imine site of PANI. By controlling the potential, we keep PANI in an oxidized state while exposing it to a solution of AuCl₄ to form a PANI*AuCl₄ complex. The AuCl₄ is reduced to atomic gold by sweeping the potential negative. That frees up the imine sites of PANI again and makes them accessible for the next Au deposition cycle. The repeated deposition of Au atoms follows a cyclic pathway. The amount of gold deposited using this method is consistent for each repeated cycle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precise Frequency Measurements Using a Superconducting Cavity Stabilized Oscillator

Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.

Strayer, D. M.↗

High-Contrast Coronagraph Performance in the Presence of DM Actuator Defects

Deformable Mirrors (DMs) are critical elements in high contrast coronagraphs, requiring precision and stability measured in picometers to enable detection of Earth-like exoplanets. Occasionally DM actuators or their associated cables or electronics fail, requiring a wavefront control algorithm to compensate for actuators that may be displaced from their neighbors by hundreds of nanometers. We have carried out experiments on our High-Contrast Imaging Testbed (HCIT) to study the impact of failed actuators in partial fulfillment of the Terrestrial Planet Finder Coronagraph optical model validation milestone. We show that the wavefront control algorithm adapts to several broken actuators and maintains dark-hole contrast in broadband light.

adaptive optics↗

Additive manufacturing of multiscale NiFeMn multi-principal element alloys with tailored composition

Nanostructured multi-principal element alloys (MPEAs) have been explored as next-generation engineering materials due to unique mechanical and functional properties which have significant advantages over traditional dilute alloys. However, the practical applications of nanostructured MPEAs are still limited due to the lack of scalable processing approaches to prepare a large quantity of nanostructured MPEAs, as well as lack of an efficient pathway for high-throughput discovery of better functional nanostructured MPEAs within their vast compositional space. Here we tackle these challenges by presenting an integrated approach by combining direct-ink-writing-based additive manufacturing, solid-state sintering, and chemical dealloying to manufacture hierarchically porous MPEAs. The hierarchical structure is comprised of macro- and micro-scale pores introduced via extrusion printing and polymer decomposition during sintering, as well as nanoscale pores formed via chemical dealloying. The macro- and micro-scale pores allow efficient dealloying of a large mass of material as the diffusion length that the corroding medium must penetrate remains at the scale of the ligaments formed after sintering (∼10 μm), despite the large volume of the 3D-printed samples. In addition, this integrated approach enables versatile control of the alloy composition via precisely tuning the ratio of elemental powders in the starting ink, thus offering a pathway for high-throughput discovery of novel functional MPEAs. As a case study, multiscale macro/micro/nanoporous NiFeMn MPEAs with three different compositions were investigated as catalysts to reduce the overpotential of oxygen evolution reaction (OER), where NiFeMn-based electrocatalysts display composition-dependent performance such that the overpotential measured at a current of 0.5 A g −1 for OER increases in the order of Ni 58 Fe 29 Mn 13 ⩽ Ni 64 Fe 26 Mn 10 < Ni 76 Fe 18 Mn 6 . This introduced manufacturing process offers new opportunities for scalable fabrication and rapid screening of nanostructured multi-component complex alloys.

36 MATERIALS SCIENCE↗

High precision Hugoniot measurements on statically pre-compressed fluid helium

Here we describe how the capability for statically pre-compressing fluid targets for Hugoniot measurements utilizing gas gun driven flyer plates has been developed. Pre-compression expands the capability for initial condition control, allowing access to thermodynamic states off the principal Hugoniot. Absolute Hugoniot measurements with an uncertainty less than 3% on density and pressure were obtained on statically pre-compressed fluid helium utilizing a two stage light gas gun. Helium is highly compressible; the locus of shock states resulting from dynamic loading of an initially compressed sample at room temperature is significantly denser than the cryogenic fluid Hugoniot even for relatively modest (0.27–0.38 GPa) initial pressures. Lastly, the dynamic response of pre-compressed helium in the initial density range of 0.21–0.25 g/cm3 at ambient temperature may be described by a linear shock velocity (us) and particle velocity (u p ) relationship: u s = C 0 + su p , with C 0 = 1.44 ± 0.14 km/s and s = 1.344 ± 0.025.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Catabolic repression in early-diverging anaerobic fungi is partially mediated by natural antisense transcripts

We report that early-diverging anaerobic fungi (order: Neocallimastigomycota), lignocelluolytic chytrid-like fungi central to fiber degradation in the digestive tracts of large herbivores, are attractive sources of cellulases and hemicellulases for biotechnology. Enzyme expression is tightly regulated and coordinated through mechanisms that remain unelucidated to optimize hydrolytic efficiency. Our analysis of anaerobic fungal transcriptomes reveals hundreds of cis-natural antisense transcripts (cis-NATs), which we hypothesize play an integral role in this regulation. Through integrated genomic and transcriptomic sequencing on a range of catabolic substrates, we validate these NATs in three species (Anaeromyces robustus, Neocallimasix californiae, and Piromyces finnis), and analyze their expression patterns and prevalence to gain insight into their function. NAT function was diverse and conserved across the three fungal genomes studied, with 10% of all metabolic process NATs associated with lignocellulose hydrolysis. Despite these similarities, however, only eleven gene targets were conserved orthologs. Several NATs were dynamically regulated by lignocellulosic substrates while their gene targets were unregulated. This observation is consistent with a hypothesized, but untested, regulatory mechanism where selected genes are exclusively regulated at the transcriptional/post-transcriptional level by NATs. However, only genes with high NAT relative expression levels displayed this phenomenon, suggesting a selection mechanism that favors larger dynamic ranges for more precise control of gene expression. In addition to this mode, we observed two other possible regulatory fates: canonical transcriptional regulation with no NAT response, and positive co-regulation of target mRNA and cognate NAT, which we hypothesize is a fine-tuning strategy to locally negate control outputs from global regulators. In conclusion, our work reveals the complex contributions of antisense RNA to the catabolic response in anaerobic fungi, highlighting its importance in understanding lignocellulolytic activity for bioenergy applications. More importantly, the relative expression of NAT to target may form a critical determinant of transcriptional vs post-transcriptional (NAT) control of gene expression in primitive anaerobic fungi.

59 BASIC BIOLOGICAL SCIENCES↗

Phase 1/2 Study of the Addition of Cisplatin to Adjuvant Chemotherapy With Image Guided High-Precision Radiation Therapy for Completely Resected Gastric Cancer

Purpose: Locoregional recurrence is common after surgery for gastric cancer. Adjuvant therapy improves outcomes but with toxicity. This phase 1/2 study investigated infusional 5-fluorouracil (5-FU) in combination with biweekly cisplatin delivered concurrently with image guided high-precision radiation therapy. Methods and Materials: Eligible patients had completely resected stage IB to IV (Union for International Cancer Control TNM 6th edition) nonmetastatic gastric adenocarcinoma. Treatment constituted 12 weeks of infusional 5-FU (200 mg/m{sup 2}/day) with cisplatin added in a standard 3 + 3 dose escalation protocol (0, 20, 30, and 40 mg/m{sup 2}) during weeks 1, 3, 5, and 7, and an additional week 9 dose in the final cohort. Radiation therapy (45 Gy in 25 fractions) was delivered during weeks 3 to 7. Maximum tolerated dose (MTD) was determined in phase 1 and confirmed in phase 2. Results: Among the 55 patients (median age, 54 years; range 28-77 years; 55% male), the median follow-up time was 3.0 years (range, 0.3-5.3 years). Five patients in phase 1 experienced dose-limiting toxicity, and MTD was determined as 4 cycles of 40 mg/m{sup 2} cisplatin. Twenty-seven patients were treated at MTD. Acute grade 3 to 4 toxicity rate was 37.0% at MTD and 29.1% across all dose levels. No treatment-related deaths occurred. Fourteen patients experienced recurrent disease. The 2-year overall survival (OS) and relapse-free survival were 85% and 74%, respectively. Median OS has not been reached. Quality of life (QOL) was impaired during treatment, but most scores recovered by 4 weeks. Conclusion: Cisplatin can be safely delivered with 5-FU–based chemoradiation therapy. Acute toxicity was acceptable, and patient-reported QOL showed the regimen was tolerable. Outcomes are encouraging and justify further study of this regimen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Speed-dependent effects in the near-infrared spectrum of self-colliding H{sub 2}{sup 18}O molecules

The absorption line shape of a given H{sub 2}{sup 18}O vibration-rotation line at 1.38 {mu}m was deeply investigated using a spectroscopic approach based upon the use of a pair of offset-frequency locked extended-cavity diode lasers. This dual-laser apparatus ensures extreme levels of accuracy in controlling and measuring any variation of the laser frequency around a given absolute reference. As a result, high levels of precision and accuracy were reached in the observation of a molecular absorption line shape in the near infrared. A variety of semiclassical models, accounting for Dicke narrowing and speed-dependent effects, were implemented and tested in order to describe the physical situation of self-colliding H{sub 2}{sup 18}O molecules. Our study demonstrates that the molecular confinement alone is unable to explain entirely the departures from the Voigt profile and that the speed dependence of pressure-induced broadening and shift cannot be ignored, even in the case of pure water samples at relatively small pressures. The absorption spectrum was successfully interpolated using the uncorrelated version of the speed-dependent Galatry profile, with a hypergeometric dependence on the absorber speed for both pressure broadening and pressure shift parameters, thus reaching an agreement between theory and experiment at the level of 5x10{sup -5}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Phase-Space Manipulation of Ultracold Ion Bunches with Time-Dependent Fields

All applications of high brightness ion beams depend on the possibility to precisely manipulate the trajectories of the ions or, more generally, to control their phase-space distribution. We show that the combination of a laser-cooled ion source and time-dependent acceleration fields gives new possibilities to perform precise phase-space control. We demonstrate reduction of the longitudinal energy spread and realization of a lens with control over its focal length and sign, as well as the sign of the spherical aberrations. This creates new possibilities to correct for the spherical and chromatic aberrations which are presently limiting the spatial resolution.

43 PARTICLE ACCELERATORS↗

A New Approach to Robot Motor Control

This poster details the motor control improvements to Fermilab's Remote Viewing Robot (RVR). It is a robot tasked with remotely investigating issues within the accelerator tunnels at Fermilab. Initially controlled by a single Raspberry Pi that housed all the robot s operations, the RVR will now use a Raspberry Pi Pico W for its motor control. This was achieved using Pulse Width Modulation (PWM) to allow for precise speed and torque control for the robot. This enhances the robot s reliability. By addressing the challenge of navigating high radiation environments, the upgrade helps assist the RVR s goal of decreasing the need for human intervention in accelerator tunnels.

Lopez, Jacob↗