Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Assessing residential PM 2.5 concentrations and infiltration factors with high spatiotemporal resolution using crowdsourced sensors

Building conditions, outdoor climate, and human behavior influence residential concentrations of fine particulate matter (PM 2.5 ). To study PM 2.5 spatiotemporal variability in residences, we acquired paired indoor and outdoor PM 2.5 measurements at 3,977 residences across the United States totaling >10,000 monitor-years of time-resolved data (10-min resolution) from the PurpleAir network. Time-series analysis and statistical modeling apportioned residential PM 2.5 concentrations to outdoor sources (median residential contribution = 52% of total, coefficient of variation = 69%), episodic indoor emission events such as cooking (28%, CV = 210%) and persistent indoor sources (20%, CV = 112%). Residences in the temperate marine climate zone experienced higher infiltration factors, consistent with expectations for more time with open windows in milder climates. Likewise, for all climate zones, infiltration factors were highest in summer and lowest in winter, decreasing by approximately half in most climate zones. Large outdoor–indoor temperature differences were associated with lower infiltration factors, suggesting particle losses from active filtration occurred during heating and cooling. Absolute contributions from both outdoor and indoor sources increased during wildfire events. Infiltration factors decreased during periods of high outdoor PM 2.5 , such as during wildfires, reducing potential exposures from outdoor-origin particles but increasing potential exposures to indoor-origin particles. Time-of-day analysis reveals that episodic emission events are most frequent during mealtimes as well as on holidays (Thanksgiving and Christmas), indicating that cooking-related activities are a strong episodic emission source of indoor PM 2.5 in monitored residences.

54 ENVIRONMENTAL SCIENCES↗

A detailed analysis of the high-resolution X-ray spectra of NGC 3516: variability of the ionized absorbers

The 1.5 Seyfert galaxy NGC 3516 presents a strong time variability in X-rays. We re-analyzed the nine observations performed in 2006 October by XMM-Newton and Chandra in the 0.3 to 10 keV energy band. An acceptable model was found for the XMM-Newton data fitting the EPIC-PN and RGS spectra simultaneously; later, this model was successfully applied to the contemporary Chandra high-resolution data. The model consists of a continuum emission component (power law + blackbody) absorbed by four ionized components (warm absorbers), and 10 narrow emission lines. Three absorbing components are warm, producing features only in the soft X-ray band. The fourth ionization component produces Fe XXV and Fe XXVI in the hard-energy band. We study the time response of the absorbing components to the well-detected changes in the X-ray luminosity of this source and find that the two components with the lower ionization state show clear opacity changes consistent with gas close to photoionization equilibrium. These changes are supported by the models and by differences in the spectral features among the nine observations. On the other hand, the two components with higher ionization state do not seem to respond to continuum variations. The response time of the ionized absorbers allows us to constrain their electron density and location. We find that one component (with intermediate ionization) must be located within the obscuring torus at a distance 2.7 × 10{sup 17} cm from the central engine. This outflowing component likely originated in the accretion disk. The three remaining components are at distances larger than 10{sup 16}-10{sup 17} cm. Two of the absorbing components in the soft X-rays have similar outflow velocities and locations. These components may be in pressure equilibrium, forming a multi-phase medium, if the gas has metallicity larger than the solar one (≳ 5 Z {sub ☉}). We also search for variations in the covering factor of the ionized absorbers (although partial covering is not required in our models). We find no correlation between the change in covering factor and the flux of the source. This, in connection with the observed variability of the ionized absorbers, suggests that the changes in flux are not produced by this material. If the variations are indeed produced by obscuring clumps of gas, these must be located much closer in to the central source.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Resolution X-Ray Structure and Functional Analysis of the Murine Norovirus 1 Capsid Protein Protruding Domain

Murine noroviruses (MNV) are closely related to the human noroviruses (HuNoV), which cause the majority of nonbacterial gastroenteritis. Unlike HuNoV, MNV grow in culture and in a small-animal model that represents a tractable model to study norovirus biology. To begin a detailed investigation of molecular events that occur during norovirus binding to cells, the crystallographic structure of the murine norovirus 1 (MNV-1) capsid protein protruding (P) domain has been determined. Crystallization of the bacterially expressed protein yielded two different crystal forms (Protein Data Bank identifiers [PDB ID], 3LQ6 and 3LQE). Comparison of the structures indicated a large degree of structural mobility in loops on the surface of the P2 subdomain. Specifically, the A{prime}-B{prime} and E{prime}-F{prime} loops were found in open and closed conformations. These regions of high mobility include the known escape mutation site for the neutralizing antibody A6.2 and an attenuation mutation site, which arose after serial passaging in culture and led to a loss in lethality in STAT1{sup -/-} mice, respectively. Modeling of a Fab fragment and crystal structures of the P dimer into the cryoelectron microscopy three-dimensional (3D) image reconstruction of the A6.2/MNV-1 complex indicated that the closed conformation is most likely bound to the Fab fragment and that the antibody contact is localized to the A{prime}-B{prime} and E{prime}-F{prime} loops. Therefore, we hypothesize that these loop regions and the flexibility of the P domains play important roles during MNV-1 binding to the cell surface.

36 MATERIALS SCIENCE↗

Di-J/Ψ Studies, Level 3 Tracking and the D0 Run IIb Upgrade

The D0 detector underwent an upgrade to its silicon vertex detector and triggering systems during the transition from Run IIa to Run IIb to maximize its ability to fully exploit Run II at the Fermilab Tevatron. This thesis describes improvements made to the tracking and vertexing algorithms used by the high level trigger in both Run IIa and Run IIb, as well as a search for resonant di-J/Ψ states using both Run IIa and Run IIb data. Improvements made to the tracking and vertexing algorithms during Run IIa included the optimization of the existing tracking software to reduce overall processing time and the certification and testing of a new software release. Upgrades made to the high level trigger for Run IIb included the development of a new tracking algorithm and the inclusion of the new Layer 0 silicon detector into the existing software. The integration of Layer 0 into the high level trigger has led to an improvement in the overall impact parameter resolution for tracks of ~50%. The development of a new parameterization method for finding the error associated to the impact parameter of tracks returned by the high level tracking algorithm, in association with the inclusion of Layer 0, has led to improvements in vertex resolution of ~4.5 μm. A previous search in the di-J/Ψ channel revealed a unpredicted resonance at ~13.7 GeV/c 2 . A confirmation analysis is presented using 2.8 fb -1 of data and two different approaches to cuts. No significant excess is seen in the di-J/Ψ mass spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mass Spectrometry Imaging of Biological Tissue: An Approach for Multicenter Studies

Mass spectrometry imaging has become a popular tool for probing the chemical complexity of biological surfaces. This led to the development of a wide range of instrumentation and preparation protocols. It is thus desirable to evaluate and compare the data output from different methodologies and mass spectrometers. Here, we present an approach for the comparison of mass spectrometry imaging data from different laboratories (often referred to as multicenter studies). This is exemplified by the analysis of mouse brain sections in five laboratories in Europe and the USA. The instrumentation includes matrix-assisted laser desorption/ionization (MALDI)-time-of-flight (TOF), MALDI-QTOF, MALDIFourier transform ion cyclotron resonance (FTICR), atmospheric-pressure (AP)-MALDI-Orbitrap, and cluster TOF-secondary ion mass spectrometry (SIMS). Experimental parameters such as measurement speed, imaging bin width, and mass spectrometric parameters are discussed. All datasets were converted to the standard data format imzML and displayed in a common open-source software with identical parameters for visualization, which facilitates direct comparison of MS images. The imzML conversion also allowed exchange of fully functional MS imaging datasets between the different laboratories. The experiments ranged from overview measurements of the full mouse brain to detailed analysis of smaller features (depending on spatial resolution settings), but common histological features such as the corpus callosum were visible in all measurements. High spatial resolution measurements of AP-MALDI-Orbitrap and TOF-SIMS showed comparable structures in the low-micrometer range. We discuss general considerations for planning and performing multicenter studies in mass spectrometry imaging. This includes details on the selection, distribution, and preparation of tissue samples as well as on data handling. Such multicenter studies in combination with ongoing activities for reporting guidelines, a common data format (imzML) and a public data repository can contribute to more reliability and transparency of MS imaging studies.

Environmental Molecular Sciences Laboratory↗

Enrichment Meter Dataset from High-Resolution Gamma Spectroscopy Measurements of U3O8 Enrichment Standards and UF6 Cylinder Wall Equivalents

The Enrichment Meter Principle (EMP) is the basis for a commonly used standard test method for the non-destructive assay of 235 U enrichment in bulk compounds [1]. The technique involves determining the net count rate in the direct 186 keV peak using medium or high energy gamma-ray spectrometry in a fixed geometry. With suitable correction for wall attenuation, compound type, rate loss (live time), and peaked background (if significant), the atom fraction of 235 U may be obtained from the counting rate from a linear relationship through the origin. The widespread use of this method for field verification of enrichment [2,3] together with the fact that the response function rests on fundamental physics considerations (i.e., is not represented by a convenient but arbitrary form) makes it an interesting example of uncertainty quantification, one in which one can expect a valid measurement model can be applied. When applied using NaI(Tl) and region of interest analysis, the technique is susceptible to both interference error and bias [2-4]. When implemented using high-resolution gamma-ray spectroscopy, the spectrum interpretation is considerable simplified and more robust [5]. However, a practical challenge to studying the uncertainty budget of the EMP method (for example, to test linearity, extract wall corrections and so forth using modern methods) is the availability of quality experimental data that can be referenced and shared. To fill this gap, the research team undertook an experimental campaign [6]. A measurement campaign was conducted to produce high-resolution gamma spectroscopy enrichment meter data comparable to UF 6 cylinder measurements. The purpose of this report is to provide both an introduction to and quality assurance (QA) of the raw data produced. This report is intended for the analyst or researcher who uses the raw data. Unfortunately, the raw data (i.e., the spectra files) are too voluminous to include in this report but can be requested from Steven Croft of the Safeguards & Security Technology Group (scroft@ornl.gov 865-241-2834). The complete processed data are tabulated in Appendix A. The analysis techniques used to produce the QA data presented in this report [e.g., three regions-ofinterest (ROI) peak extraction and batch analysis processes] are not the most sophisticated techniques available; analysts are encouraged to reanalyze the raw data using more sensitive techniques and to improve upon the results presented here. With that being said, the analysis techniques used here are more than adequate to present and inspect the quality of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

M31 GLOBULAR CLUSTER ABUNDANCES FROM HIGH-RESOLUTION, INTEGRATED-LIGHT SPECTROSCOPY

We report the first detailed chemical abundances for five globular clusters (GCs) in M31 from high-resolution (R approx 25,000) spectroscopy of their integrated light (IL). These GCs are the first in a larger set of clusters observed as part of an ongoing project to study the formation history of M31 and its GC population. The data presented here were obtained with the HIRES echelle spectrograph on the Keck I telescope and are analyzed using a new IL spectra analysis method that we have developed. In these clusters, we measure abundances for Mg, Al, Si, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Y, and Ba, ages >=10 Gyr, and a range in [Fe/H] of -0.9 to -2.2. As is typical of Milky Way GCs, we find these M31 GCs to be enhanced in the alpha-elements Ca, Si, and Ti relative to Fe. We also find [Mg/Fe] to be low relative to other [alpha/Fe], and [Al/Fe] to be enhanced in the IL abundances. These results imply that abundances of Mg, Al (and likely O, Na) recovered from IL do display the inter- and intra-cluster abundance variations seen in individual Milky Way GC stars, and that special care should be taken in the future in interpreting low- or high-resolution IL abundances of GCs that are based on Mg-dominated absorption features. Fe-peak and the neutron-capture elements Ba and Y also follow Milky Way abundance trends. We also present high-precision velocity dispersion measurements for all five M31 GCs, as well as independent constraints on the reddening toward the clusters from our analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold speed-up of the processing (from 1336 to 150 s). Conclusions: Adaptive anisotropic filtering has the potential to substantially improve image quality and/or reduce the radiation dose required for obtaining 3D image data using cone beam CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Approach to Predict Hydrogeological Parameters Using Shear Waves from the Multichannel Analysis of Surface Waves Method

For near-surface contaminant characterization, the accurate prediction of hydrogeological parameters in anisotropic and heterogeneous environments has been a challenge since the last decades. However, recent advances in near-surface geophysics have facilitated the use of geophysical data for hydrogeological characterization in the last few years. A pseudo 3-D high resolution P-wave shallow seismic reflection survey was performed at the P Reactor Area, Savannah River Site, South Carolina in order to delineate and predict migration pathways of a large contaminant plume including trichloroethylene. This contaminant plume originates from the northwest section of the reactor facility that is located within the Upper Atlantic Coastal Plain. The data were collected with 40 Hz geophones, an accelerated weight-drop as seismic source and 1 m receiver spacing with near- and far-offsets of 0.5 and 119.5 m, respectively. In such areas with near-surface contaminants, a detailed subsurface characterization of the vadose zone hydraulic parameters is very important. Indeed, an inexpensive method of deriving such parameters by the use of seismic reflection surveys is beneficial, and our approach uses the relationship between seismic velocity and hydrogeological parameters together with empirical observations relating porosity to permeability and hydraulic conductivity. Shear wave velocity ( V s ) profiles were estimated from surface wave dispersion analysis of the seismic reflection data and were subsequently used to derive hydraulic parameters such as porosity, permeability, and hydraulic conductivity. Additional geophysical data including core samples, vertical seismic profiling, surface electrical resistivity tomography, natural gamma and electrical resistivity logs allowed for a robust assessment of the validity and geological significance of the estimated V s and hydrogeological models. The results demonstrate the usefulness of this approach for the upper 15 m of shallow unconsolidated sediments even though the survey design parameters were not optimal for surface wave analysis due to the higher than desired frequency geophones.

Engineering↗

Characterizing patterns and variability of building electric load profiles in time and frequency domains

The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. Furthermore, the commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Live cell imaging of cellular dynamics in poplar wood using computational cannula microscopy

This study presents significant advancements in computational cannula microscopy for live imaging of cellular dynamics in poplar wood tissues. Leveraging machine-learning models such as pix2pix for image reconstruction, we achieved high-resolution imaging with a field of view of 55µm using a 50µm-core diameter probe. Our method allows for real-time image reconstruction at 0.29 s per frame with a mean absolute error of 0.07. We successfully captured cellular-level dynamics in vivo , demonstrating morphological changes at resolutions as small as 3µm. We implemented two types of probabilistic neural network models to quantify confidence levels in the reconstructed images. This approach facilitates context-aware, human-in-the-loop analysis, which is crucial for in vivo imaging where ground-truth data is unavailable. Using this approach we demonstrated deep in vivo computational imaging of living plant tissue with high confidence (disagreement score ⪅0.2). This work addresses the challenges of imaging live plant tissues, offering a practical and minimally invasive tool for plant biologists.

Ingold, Alexander (ORCID:0009000752380016)↗

The extended ‘stellar halo’ of the Ursa Minor dwarf galaxy

Stellar candidates in the Ursa Minor (UMi) dwarf galaxy have been found using a new Bayesian algorithm applied to Gaia EDR3 data. Five of these targets are located in the extreme outskirts of UMi, from ∼5 to 12 elliptical half-light radii (r h ), where r h (UMi) = 17.32 ± 0.11 arcmin, and have been observed with the high-resolution Gemini Remote Access to CFHT ESPaDOnS Spectrograph at the Gemini North telescope. Precise radial velocities (σ RV < 2 km s −1 ) and metallicities (σ [Fe/H] < 0.2 dex) confirm their memberships of UMi. Detailed analysis of the brightest and outermost star (Target 1, at ∼12r h ), yields precision chemical abundances for the α (Mg, Ca, and Ti), odd-Z (Na, K, and Sc), Fe-peak (Fe, Ni, and Cr), and neutron-capture (Ba) elements. With data from the literature and APOGEE data release 17, we find the chemical patterns in UMi are consistent with an outside-in star-formation history that includes yields from core-collapse supernovae, asymptotic giant branch stars, and Type Ia supernovae. Evidence for a knee in the [α/Fe] ratios near [Fe/H] ∼ −2.1 indicates a low star-formation efficiency similar to that in other dwarf galaxies. Detailed analysis of the surface number density profile shows evidence that UMi’s outskirts have been populated by tidal effects, likely as a result of completing multiple orbits around the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate geometries for “Mountain pass” regions of the Ramachandran plot using quantum chemical calculations

Unusual local arrangements of protein in Ramachandran space are not well represented by standard geometry tools used in either protein structure refinement using simple harmonic geometry restraints or in protein simulations using molecular mechanics force fields. In contrast, quantum chemical computations using small poly-peptide molecular models can predict accurate geometries for any well-defined backbone Ramachandran orientation. Additionally, for conformations along transition regions-$\phi$ from -60 to 60°-a very good agreement with representative high-resolution experimental X-ray (≤1.5 Å) protein structures is obtained for both backbone C -1 -N-C α angle and the nonbonded O -1 …C distance, while "standard geometry" leads to the "clashing" of O…C atoms and Amber FF99SB predicts distances too large by about 0.15 Å. These results confirm that quantum chemistry computations add valuable support for detailed analysis of local structural arrangements in proteins, providing improved or missing data for less understood high-energy or unusual regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hypernuclear Spectroscopy at JLab Hall C

Since the 1st generation experiment, E89-009, which was successfully carried out as a pilot experiment of (e,e&#x27;K+) hypernuclear spectroscopy at JLab Hall C in 2000, precision hypernuclear spectroscopy by the (e,e&#x27;K+) reactions made considerable progress. It has evolved to the 2nd generation experiment, E01-011, in which a newly constructed high resolution kaon spectrometer (HKS) was installed and the “Tilt method” was adopted in order to suppress large electromagnetic background and to run with high luminosity. Preliminary high-resolution spectra of 7ΛHe and 28ΛAl together with that of 12ΛB that achieved resolution better than 500 keV(FWHM) were obtained. The third generation experiment, E05-115, has completed data taking with an experimental setup combining a new splitter magnet, high resolution electron spectrometer (HES) and the HKS used in the 2nd generation experiment. The data were accumulated with targets of 7Li, 9Be, 10B, 12C and 52Cr as well as with those of CH2 and H2O for calibration. The analysis is under way with particular emphasis of determining precision absolute hypernuclear masses. In this article, hypernuclear spectroscopy program in the wide mass range at JLab Hall C that has undergone three generation is described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct Observation and Analysis of Low-Energy Magnons with Raman Spectroscopy in Atomically Thin NiPS 3

van der Waals (vdW) magnets have rapidly emerged as a fertile playground for fundamental physics and exciting applications. Despite the impressive developments over the past few years, technical limitations pose a severe challenge to many other potential breakthroughs. High on the list is the lack of suitable experimental tools for studying spin dynamics on atomically thin samples. Here, Raman scattering techniques are employed to directly observe the low-lying magnon (~1 meV) even in bilayer NiPS 3 . Further, the advantage is that it offers excellent energy resolutions far better on low-energy sides than most inelastic neutron spectrometers can offer. More importantly, with appropriate theoretical analysis, the polarization dependence of the Raman scattering by those low-lying magnons also provides otherwise hidden information on the dominant spin-exchange scattering paths for different magnons. By comparing with high-resolution inelastic neutron scattering data, these low-energy Raman modes are confirmed to be indeed of magnon origin. Because of the different scattering mechanisms involved in inelastic neutron and Raman scattering, this information is fundamental in pinning down the final spin Hamiltonian. This work demonstrates the capability of Raman spectroscopy to probe the genuine two-dimensional spin dynamics in atomically thin vdW magnets, which can provide insights that are obscured in bulk spin dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A spectroscopic census in young stellar regions: the σ Orionis cluster

We present a spectroscopic survey of the stellar population of the σ Orionis cluster. We have obtained spectral types for 340 stars. Spectroscopic data for spectral typing come from several spectrographs with similar spectroscopic coverage and resolution. More than half of the stars in our sample are members confirmed by the presence of lithium in absorption, strong Hα in emission or weak gravity-sensitive features. In addition, we have obtained high-resolution (R ∼ 34,000) spectra in the Hα region for 169 stars in the region. Radial velocities were calculated from this data set. The radial velocity distribution for members of the cluster is in agreement with previous work. Analysis of the profile of the Hα line and infrared observations reveals two binary systems or fast rotators that mimic the Hα width expected in stars with accretion disks. On the other hand, there are stars with optically thick disks and narrow Hα profiles not expected in stars with accretion disks. This contribution constitutes the largest homogeneous spectroscopic data set of the σ Orionis cluster to date.

79 ASTRONOMY AND ASTROPHYSICS↗

A gradient based method for modeling baryons and matter in halos of fast simulations

Fast N-body PM simulations with a small number of time steps such as FastPM or COLA have been remarkably successful in modeling the galaxy statistics, but their lack of small scale force resolution and long time steps cannot give accurate halo matter profiles or matter power spectrum. High resolution N-body simulations can improve on this, but lack baryonic effects, which can only be properly included in hydro simulations. Here we present a scheme to calibrate the fast simulations to mimic the precision of the hydrodynamic simulations or high resolution N-body simulations. The scheme is based on a gradient descent of either effective gravitational potential, which mimics the short range force, or of effective enthalpy, which mimics gas hydrodynamics and feedback. The scheme is fast and differentiable, and can be incorporated as a post-processing step into any simulation. It gives very good results for the matter power spectrum for several of the baryonic feedback and dark matter simulations, and also gives improved dark matter halo profiles. The scheme is even able to find the large subhalos, and increase the correlation coefficient between the fast simulations and the high resolution N-body or hydro simulations. It can also be used to add baryonic effects to the high resolution N-body simulations. While the method has free parameters that can be calibrated on various simulations, they can also be viewed as astrophysical nuisance parameters describing baryonic effects that can be marginalized over during the data analysis. In this view these parameters can be viewed as an efficient parametrization of baryonic effects.