Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Does UV disinfection compromise sutures? An evaluation of tissue response and suture retention in salmon surgically implanted with transmitters

Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiation (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.

disinfection↗

Proton Beam Therapy Interference With Implanted Cardiac Pacemakers

Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined before and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conformal Arc Radiotherapy for Prostate Cancer: Increased Biochemical Failure in Patients With Distended Rectum on the Planning Computed Tomogram Despite Image Guidance by Implanted Markers

Purpose: To evaluate the effect of rectal distention on the planning computed tomogram on freedom from biochemical failure (FFBF) of prostate cancer patients treated with image-guided conformal arc radiotherapy. Methods and Materials: The outcomes of 238 patients with T1-T3N0M0 tumors were analyzed, with a median follow-up of 53 months (range, 24-93 months). In 213 patients, daily co-registration of X-rays and digitally reconstructed radiographs was used for positioning, whereas in 25 patients positioning was done using direct prostate visualization with implanted markers. The rectal average cross-sectional area was determined on the planning computed tomogram. Results: The 5-year freedom from Grade 3 to 4 late gastrointestinal and urinary side effect, according to the Radiation Therapy Oncology Group criteria, was 100% and 99.4% respectively. The 5-year FFBF was 88.4%. On multivariate analysis the following variables were significantly related to worse FFBF: risk group according to the National Comprehensive Cancer Network (high- to very high risk vs. intermediate- to low-risk), dose (70 vs. 78 Gy), average cross-sectional area ({>=}16 vs. <16 cm{sup 2}) and, unexpectedly, the use of implanted markers as opposed to bony structures for patient positioning. In retrospect, the margins around the clinical target volume appeared to be inadequate in the cases in which markers were used. Conclusion: Overall, the outcome of patients treated with image-guided conformal arc radiotherapy is excellent. We were able to confirm the negative prognostic impact of a distended rectum on the planning computed tomogram described by others. The study illustrates the potential danger of image guidance techniques as to margin reduction around the clinical target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effectiveness of Using Fewer Implanted Fiducial Markers for Prostate Target Alignment

Purpose: To evaluate the impact of the number and location of intraprostatic fiducial markers on the accuracy and reproducibility of daily prostate target alignment and to evaluate the migration of such markers. Methods and Materials: Three gold fiducial markers were implanted transrectally under ultrasound guidance near the apex, middle, and base of the prostate in 10 prostate cancer patients. The patients had pretreatment in-room computed tomography (CT) scans three times a week, for approximately 25 CT scans per patient during the 8-week treatment course. A total of 1280 alignments were performed using different alignment scenarios: whole-prostate soft tissue alignment (the gold standard), bone alignment, and seven permutations of alignments using one, two, or three fiducial markers. The results of bone alignment and fiducial alignment were compared with the results of whole-prostate alignment. Fiducial migration was also evaluated. Results: Single-fiducial-marker alignment was more accurate and reproducible than bone alignment. However, due to organ deformation, single fiducial markers did not always reliably represent the position of the entire prostate. The use of two-fiducial combinations was more accurate and reproducible than single-fiducial alignment, and use of all three fiducials was the best. Use of an apex fiducial together with a base fiducial rivaled the use of all three fiducials markers together. Fiducial migration was minimal. Conclusions: The number and the location of implanted fiducial markers affect the accuracy and reliability of daily prostate target alignment. The use of two or more fiducial markers is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of a Phase II Trial of Ultrasound-Guided Radioactive Implantation of the Prostate for Definitive Management of Localized Adenocarcinoma of the Prostate (RTOG 98-05)

Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I{sup 125} implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of {<=}10 ng/ml; and a Gleason score of {<=}6. All patients underwent transrectal ultrasound-guided radioactive I{sup 125} seed implantation into the prostate. The prescribed dose was 145 Gy to the prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design highlights the probable generalizability of the outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of the Effects of High-Energy Photon Beam Irradiation (10 and 18 MV) on 2 Types of Implantable Cardioverter-Defibrillators

Purpose: Radiation therapy for cancer may be required for patients with implantable cardiac devices. However, the influence of secondary neutrons or scattered irradiation from high-energy photons (≥10 MV) on implantable cardioverter-defibrillators (ICDs) is unclear. This study was performed to examine this issue in 2 ICD models. Methods and Materials: ICDs were positioned around a water phantom under conditions simulating clinical radiation therapy. The ICDs were not irradiated directly. A control ICD was positioned 140 cm from the irradiation isocenter. Fractional irradiation was performed with 18-MV and 10-MV photon beams to give cumulative in-field doses of 600 Gy and 1600 Gy, respectively. Errors were checked after each fraction. Soft errors were defined as severe (change to safety back-up mode), moderate (memory interference, no changes in device parameters), and minor (slight memory change, undetectable by computer). Results: Hard errors were not observed. For the older ICD model, the incidences of severe, moderate, and minor soft errors at 18 MV were 0.75, 0.5, and 0.83/50 Gy at the isocenter. The corresponding data for 10 MV were 0.094, 0.063, and 0 /50 Gy. For the newer ICD model at 18 MV, these data were 0.083, 2.3, and 5.8 /50 Gy. Moderate and minor errors occurred at 18 MV in control ICDs placed 140 cm from the isocenter. The error incidences were 0, 1, and 0 /600 Gy at the isocenter for the newer model, and 0, 1, and 6 /600Gy for the older model. At 10 MV, no errors occurred in control ICDs. Conclusions: ICD errors occurred more frequently at 18 MV irradiation, which suggests that the errors were mainly caused by secondary neutrons. Soft errors of ICDs were observed with high energy photon beams, but most were not critical in the newer model. These errors may occur even when the device is far from the irradiation field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Curie–Da Vinci Connection: 5-Years' Experience With Laparoscopic (Robot-Assisted) Implantation for High-Dose-Rate Brachytherapy of Solitary T2 Bladder Tumors

Purpose: To report experience and early results of laparoscopic implantation for interstitial brachytherapy (BT) of solitary bladder tumors and the feasibility of a high-dose-rate (HDR) schedule. Methods and Materials: From December 2009 to April 2015, 57 patients with a T2 solitary bladder tumor were treated in Arnhem with transurethral bladder resection followed by external beam irradiation, applied to the bladder and regional iliac lymph nodes, 40 Gy in 20 fractions, 5 fractions per week, and within 1 week interstitial HDR BT, in selected cases combined with partial cystectomy and lymph node dissection. The BT catheters were placed via a transabdominal approach with robotic assistance from a Da Vinci robot after a successful initial experience with a nonrobotic laparoscopic approach. The fraction schedule for HDR was 10 fractions of 2.5 Gy, 3 fractions per day. This was calculated to be equivalent to a reference low-dose-rate schedule of 30 Gy in 60 hours. Data for oncologic outcomes and toxicity (Common Toxicity Criteria version 4) were prospectively collected. Results: These modifications resulted in an average postoperative hospitalization of 6 days, minimal blood loss, and no wound healing problems. Two patients had severe acute toxicity: 1 pulmonary embolism grade 4 and 1 cardiac death. Late toxicity was mild (n=2 urogenital grade 3 toxicity). The median follow-up was 2 years. Using cumulative incidence competing risk analysis, the 2-year overall, disease-free, and disease-specific survival and local control rates were 59%, 71%, 87%, and 82%, respectively. Conclusions: The benefits of minimally invasive surgery for implantation of BT catheters and the feasibility of HDR BT in bladder cancer are documented. The patient outcome and adverse events are comparable to the best results published for a bladder-sparing approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helium bubble nucleation and growth in alloy HT9 through the use of in situ TEM: Sequential he-implantation and heavy-ion irradiation versus dual-beam irradiation

The formation of He bubbles in Ferritic/Martensitic steel HT9 is investigated through the use of in situ Transmission Electron Microscopy coupled with He implantation and heavy ion irradiation. Of particular interest is the effect of increasing He appm/dpa ratio on the formation and growth of the bubbles, as well as the effect of the sequential order of ion irradiation i.e. He-pre-implantation followed by heavy-ion irradiation versus true dual-beam irradiation. Finally, the role of He is discussed.

Duemmler, Kai↗

In situ transmission electron microscopy with dual ion beam irradiation and implantation

To study the helium effects and their interactions with displacement damage in irradiated materials, an in situ dual-ion beam irradiation capability with transmission electron microscopy was recently established at the IVEM-Tandem Facility at Argonne National Laboratory. Pure nickel was irradiated in situ individually with 1 MeV Kr ions for displacement damage study, 16 keV He ions for helium implantation, and simultaneously with 1 MeV Kr ions and 16 keV He ions at the rate of 1 at.% He/dpa to study the interaction of helium and displacement damage at 500 degrees C. Helium bubbles were formed and segregated within dislocation loops during the He implantation experiment and no bubbles were observed outside the loops. The loop size increased with increasing helium concentration. In contrast, helium bubbles were formed uniformly in the matrix when nickel was irradiated simultaneously with 1 MeV Kr ions and 16 keV He ions. Overall, it is suggested that the uniformly-distributed defect clusters formed under 1 MeV Kr ion irradiation serve as trapping sites of helium atoms resulting in homogeneous nucleation of helium bubbles under the dualion beam irradiation in nickel.

36 MATERIALS SCIENCE↗

Activation of ion-implanted polycrystalline silicon thin films prepared on glass substrates

Phosphorous-implanted polycrystalline Si thin films were subjected to thermal annealing between 300 °C and 650 °C. The thermal activation was monitored electrically and structurally using Hall measurements, Raman spectroscopy, UV–visible spectrophotometry, and transmission electron microscopy. Charge transport information was correlated to the corresponding structural evolution in thermal activation. Phosphorous-implanted activation is divided into short-range ordering at low temperatures and long-range ordering at high temperatures, with the boundary between low and high temperatures set at 425 °C. Short-range ordering allows for significant increase in electronic concentration through substitution of P for Si. Higher temperatures are attributed to long-range ordering, thereby increasing electronic mobility.

36 MATERIALS SCIENCE↗

Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to planning target volume (PTV) margins for planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploration of methods to remove implanted 210 Pb and 210 Po contamination from silicon surfaces

Radioactive contaminants on the surfaces of detector components can be a problematic source of background events for physics experiments searching for rare processes. Exposure to radon is a specific concern because it can result in the relatively long-lived 210 Pb (and progeny) being implanted to significant subsurface depths such that removal is challenging. Here, in this article, we present results from a broad exploration of cleaning treatments to remove implanted 210 Pb and 210 Po contamination from silicon, which is a material frequently used in rare-events searches. We demonstrate for the first time that heat treatments (“baking”) can effectively mitigate such surface contamination, with a 1200 °C bake resulting in a 97$^{+2}_{-3}$% reduction. We also report results using wet-chemistry and plasma-based methods, which show that etching can be highly effective provided the etch depth is sufficiently aggressive. Our survey of cleaning methods suggests consideration of multiple approaches during the different phases of detector construction to enable greater flexibility for efficient removal of 210 Pb and 210 Po surface contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of zirconium implantation on the structure of sapphire

The effect of zirconium implantation on the structure of sapphire was investigated by 175 keV Zr implantation at room temperature to a fluence of 4 1016 ions/cm2 into sapphire single crystals. Samples were examined by several experimental techniques: Rutherford backscattering spectroscopy along a channeling direction (RBS-C), electron-energy loss spectroscopy (EELS), and Z-contrast images obtained in an aberration-corrected scanning transmission electron microscope. Range and deposited energy were simulated with SRIM-2008.04. The Z-contrast images from transmission electron microscope indicated: a near surface damaged layer ~30 nm thick, a subsurface region exhibiting "random" de-channeling ~52 nm thick, and a deeper damaged, crystalline zone ~64 nm thick. The RBS-C spectra confirmed the presence of these three regions. The two damaged regions contained high concentrations of as yet unresolved defect clusters. The intermediate region contained Zr-clusters embedded in an "amorphous" matrix that exhibited short-range order corresponding to -Al2O3, i.e., a defective spinel structure. The EELS measurements show that the amorphous region is deficient in oxygen.

Sina, Younes↗

Orientation and morphology of Pt nanoparticles in γ-alumina processed via ion implantation and thermal annealing

Structure and chemistry of metal/metal-oxide interfaces are critical for many catalytic processes and sensing. Pristine interfaces of Pt and γ-Al 2 O 3 were fabricated using high-energy ion implantation and thermal processing. Amorphous regions of alumina develop in single crystal α-alumina during Pt+ implantation and an 800 °C thermal treatment crystalizes amorphized alumina to γ-Al 2 O 3 and allows Pt ions to precipitate within the developing γ-alumina, yielding Pt nanoparticle tetrahedra terminated by {111} surfaces. The phase of alumina that developed and the distribution, morphology, and orientation of Pt nanoparticles was determined using x-ray diffraction, Rutherford backscattering spectrometry, transmission electron microscopy and scanning transmission electron microscopy.

36 MATERIALS SCIENCE↗

Expression of membrane protein disulphide isomerase A1 (PDIA1) disrupt a reducing microenvironment in endometrial epithelium for embryo implantation

Various proteins in the endometrial epithelium are differentially expressed in the receptive phase and play a pivotal role in embryo implantation. The Protein Disulphide Isomerase (PDI) family contains 21 members that function as chaperone proteins through their redox activities. Although total PDIA1 protein expression was high in four common receptive (Ishikawa and RL95-2) and non-receptive (HEC1-B and AN3CA) endometrial epithelial cell lines, significantly higher membrane PDIA1 expression was found in non-receptive AN3CA cells. In Ishikawa cells, oestrogen up-regulated while progesterone down-regulated membrane PDIA1 expression. Moreover, mid-luteal phase hormone treatment down-regulated membrane PDIA1 expression. Furthermore, oestrogen at 10 nM reduced spheroid attachment on Ishikawa cells. Interestingly, inhibition of PDIA1 function by bacitracin or 16F16 increased the spheroid attachment rate onto non-receptive AN3CA cells. Over-expression of PDIA1 in receptive Ishikawa cells reduced the spheroid attachment rate and significantly down-regulated integrin β3 levels, but not integrin αV and E-cadherin. Addition of reducing agent TCEP induced a sulphydryl-rich microenvironment and increased spheroid attachment onto AN3CA cells and human primary endometrial epithelial cells collected at LH+7/8 days. The luminal epithelial cells from human endometrial biopsies had higher PDIA1 protein expression in the proliferative phase than in the secretory phase. Our findings suggest oestrogen and progesterone regulate PDIA1 expression, resulting in the differential expressions of membrane PDIA1 protein to modulate endometrial receptivity. This suggests that membrane PDIA1 expression prior to embryo transfer could be used to predict endometrial receptivity and embryo implantation in women undergoing assisted reproduction treatment.

60 APPLIED LIFE SCIENCES↗

A Transmission Electron Microscopy Study of the Effect of Interfaces on Bubble Formation in He-Implanted Cu-Nb Multilayers

Magnetron sputtered thin films of Cu, Nb, and Cu-Nb multilayers with 2.5 and 5 nm nominal layer thickness were deposited on Si and implanted with 4He+ and 3He+ ions. Secondary ion mass spectroscopy and nuclear reaction analysis, respectively, were used to measure the 4He+ and 3He+ concentration profile with depth inside the films. Cross-sectional transmission electron microscopy was used to characterize the helium bubbles. Analysis of the contrast from helium bubbles in defocused transmission electron microscope images showed a minimum bubble diameter of 1.25 nm. While pure Cu and Nb films showed bubble contrast over the entire range of helium implantation, the multilayers exhibited bubbles only above a critical He concentration that increased almost linearly with decreasing layer thickness. The work shows that large amounts of helium can be trapped at incoherent interfaces in the form of stable, nanometer-size bubbles.

36 MATERIALS SCIENCE↗

Generation of Tin-Vacancy Centers in Diamond via Shallow Ion Implantation and Subsequent Diamond Overgrowth

Group IV color centers in diamond have garnered great interest for their potential as optically active solid-state spin qubits. The future utilization of such emitters requires the development of precise site-controlled emitter generation techniques that are compatible with high-quality nanophotonic devices. This task is more challenging for color centers with large group IV impurity atoms, which are otherwise promising because of their predicted long spin coherence times without a dilution refrigerator. For example, when applied to the negatively charged tin-vacancy (SnV – ) center, conventional site-controlled color center generation methods either damage the diamond surface or yield bulk spectra with unexplained features. Here we demonstrate a novel method to generate site-controlled SnV – centers with clean bulk spectra. We shallowly implant Sn ions through a thin implantation mask and subsequently grow a layer of diamond via chemical vapor deposition. This method can be extended to other color centers and integrated with quantum nanophotonic device fabrication.

36 MATERIALS SCIENCE↗

Beyond Epitaxy: Ion Implantation as a Tool for Orbital Engineering

Manipulating electronic orbital states in quantum materials provides a powerful means of controlling their physical properties and technological functionality. Here, we demonstrate that orbital populations in strongly correlated oxide thin films can be continuously and reversibly tuned through postsynthesis He ion implantation. Using LaNiO 3 as a model system, we show that the orbital preference can be systematically adjusted from favoring in-plane d x 2 –y 2 occupation toward out-of-plane d z 2 states through precise control of ion fluence. Unlike conventional heteroepitaxial approaches that lock in orbital configurations during growth, this strain-doping technique enables continuous orbital tuning and the selective modification of specific film regions after device fabrication. We demonstrate the practical impact of this control by achieving a 7-fold enhancement in oxygen reduction reaction catalysis. This work establishes ion implantation as a powerful approach for orbital engineering that complements existing synthesis-based strategies while offering unique advantages for both basic research and device development.

Doping↗