The impact of gas purity on observed reactivity with NO using inductively coupled plasma tandem mass spectrometry

Interference removal in inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is strongly dependent on the gas selected for use within the collision/reaction cell. There has been little investigation on the effects that reaction gas impurities may have on the resulting spectra. The reactivity of 60 elements was evaluated using nitric oxide (NO 99.5%) with and without a gas purifier to reduce H 2 O impurities to <100 pptV. Experiments were performed using V, Ce, Tl and Th to investigate the effects of purified NO at various flowrates (0.22–1.49 mL min -1 ). Purified NO was shown to significantly mitigate oxy-hydride interferences, improve total ion sensitivity (notable at high gas flows), and shift product distributions advantageously. The reduction in oxy-hydride species results in a product distribution favoring the major expected products, where signals were shown to increase by an order of magnitude. Reduced background and increased signal for the major expected products provides avenues for improving various analytical applications of ICP-MS/MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The balance of orbital overlap and orbital energy in the activation of methane by actinide cations: insights from inductively coupled plasma tandem mass spectrometry

The actinides present a unique challenge to chemical theory. The classical view of covalent bonding is driven by the extent of spatial overlap of valence orbitals. Modern theory has expanded assessments of covalency to include considerations of orbital energy degeneracy to assess orbital energy mixing between metal and ligand valence orbitals. Actinide–ligand (An–L) bonding has more recently been described as a balance between orbital overlap and orbital energy mixing, where 5f and L valence orbital overlap decreases while energy mixing between An 5f and L valence orbitals increases across the series. To test these existing views, we employed inductively coupled plasma tandem mass spectrometry to examine the kinetic energy dependences of reactions of actinide cations, Th + –Am + , with methane. Further, this is the first experimental report of the energy dependences of methane activation reactions involving the cations of Pa, Np, Pu, and Am and the first experimental determination of transuranic An + –D, An + –CD 2 , An + –CD 3 , and An + –CD bond dissociation energies. The correlation of the measured An + –CD 2 bond energies with E p (6d 2 ) indicates that An + 6d orbitals are the dominant contributors in the An + –CD 2 bonds. Close examination of the relative reactivities of An + offers additional support that the balance of classical and modern views of molecular bonding may lie between Np + and Pu + and that the increased reactivity of Th + –Np + may be attributed to the increased spatial extension of the 5f orbitals whereas covalent An + bond formation may be more driven by the decreasing energies of the 5f orbitals across the actinide series.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic insight into AnO 2 + bonding from ThH + /UH + reactions studied by inductively coupled plasma tandem mass spectrometry

The bonding mechanisms of actinides have been a focus of fundamental research over the past few decades. In the present study, reactions of the simplest actinide-containing species, ThH + and UH + , with O 2 and CO 2 are investigated by inductively coupled plasma tandem mass spectrometry. The reactions of ThH + and UH + with O 2 are efficient, and the reactions of ThH + and UH + with CO 2 display reduced reaction efficiencies. For both reactions involving CO 2 , ThO 2 + and UO 2 + are observed; however, there is a clear barrier to ThO 2 + formation whereas UO 2 + forms through an exothermic, barrierless process. The experimental observations and available thermodynamic information are used to predict the outcomes of reactions involving the later AnH + . The anticipated reaction enthalpies for Pa–Am display a clear correlation with the promotion energy of An + to a 6d 2 electronic configuration, E p (6d 2 ), although a shift in the slope of the correlation of reaction enthalpies and E p (6d 2 ) suggests that there is likely a change in bonding mechanism that starts with Np + . Similar shifts have also been noted in previous studies. Beginning with Np + , the 6d orbitals become less accessible than they are for the earlier An + as measured by E p (6d 2 ), and this accessibility of the 6d orbitals may drive actinide bonding.

5f orbitals↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Range Hood Use and Effectiveness in Reducing Indoor Air Pollution During Gas and Induction Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. The study installed electric induction stoves and repeated measurements over three 2-week intensive periods, at baseline and at the end of two consecutive 3-month study phases. Stove replacements occurred at the start of Phase 1 or Phase 2 by random assignment. There were 4184 cooking events identified by automated analysis of time-series data from temperature sensors mounted above the cooktops and 1038 related range hood usage events detected from data recorded by anemometers, smart plugs, or motor loggers. Analysis of 1-minute resolved PM2.5 and NO 2 data identified and quantified 2685 PM 2.5 events and 2606 NO 2 events. Range hood use was characterized as a binary variable (>3 min vs. <3 min use). Range hood use was more common during cooking events associated with particle emissions and longer cooking durations. PM 2.5 concentrations during events with range hood use were comparable to those without use, which could result from limited effectiveness or if range hoods were preferentially used during higher-emission cooking scenarios. In homes with gas cooking, integrated NO 2 concentrations were about 45 percent higher during cooking events with no range hood use compared to those range hood use. The lowest pollutant levels were observed when the range hood operated for more than half of the cooking duration. These findings show that operation of venting range hood during cooking can substantially reduce short-term indoor exposure NO 2 in homes with gas cooking.

Fang, Yi↗

High-energy negative ion beam obtained from pulsed inductively coupled plasma for charge-free etching process

Negative ions in conventional inductively coupled plasma are often more chemically active than positive ions (for example, in CF{sub 4} or SF{sub 6} plasmas), but inconveniently they are trapped inside the sheath and cannot be used for high-energy surface etching in sources with a grid-type acceleration system. In this work we describe a method of positive and negative ion extraction that allows the energy and flux of oppositely charged particles to be varied independently. Then by scattering the ions off from a metal surface, it is possible to form a high-energy beam of neutrals from the negative ions by using the low-energy positive component of the beam current for better charge compensation.

43 PARTICLE ACCELERATORS↗

Experimental investigation of the Boltzmann relation for a bi-Maxwellian distribution in inductively coupled plasmas

In plasma, the Boltzmann relation is often used to connect the electron density to the plasma potential because it is not easy to calculate electric potentials on the basis of the Poisson equation due to the quasineutrality. From the Boltzmann relation, the electric potential can be simply obtained from the electron density or vice versa. However, the Boltzmann relation assumes that electrons are in thermal equilibrium and have a Maxwellian distribution, so it cannot be applied to non-Maxwellian distributions. In this paper, the Boltzmann relation for bi-Maxwellian distributions was newly derived from fluid equations and the comparison with the experimental results was given by measuring electron energy probability functions in an inductively coupled plasma. It was found that the spatial distribution of the electron density in bulk plasma is governed by the effective electron temperature, while that of the cold and hot electrons are governed by each electron temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlocal collisionless power absorption using effective viscosity model in inductively coupled plasma discharges

Effective viscosity model for inductively coupled plasma (ICP) discharges has been used to calculate the power absorbed inside ICP discharges. It is found that it can be used to calculate collisionless heating, which is a warm plasma effect. The validity of effective viscosity model has been checked by comparing it with kinetic model for warm ICP discharges. For very small plasma lengths, the results of both models are the same. At intermediate lengths where bounce resonance heating is important, results of the two models are not the same. Bounce resonance length given by effective viscosity model does not match very well with that given by the kinetic model. It shows that bounce resonance heating cannot be taken care of accurately using the effective viscosity model. For large plasma length, when driving frequencies are low, power absorbed calculated using the kinetic model is more than that calculated by the effective viscosity model. For high driving frequencies, power absorbed calculated using the kinetic model is less than that calculated by the effective viscosity model. The best match between the results of two models (for large plasma length) is obtained if the combination of plasma density, electron temperature, driving frequency, and speed of light is such that the relation K={omega}{sub p}v{sub th}/{omega}c{approx_equal}1 holds. It is concluded that computationally less extensive effective viscosity model can be used to estimate power absorption in ICP discharges by calibrating it with the help of computationally intensive kinetic model. Once calibration is done a lot of computational effort can be avoided by using effective viscosity model instead of kinetic model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation and Experimental Study of a 13.56 MHz Planar Coil, Inductively Coupled Plasma Reactor

Hysteresis in a 13.56 MHz planar coil, inductively coupled plasma (ICP) reactor is modeled using the methods prescribed in El-Fayoumiet al. and Turneret al. The stable working points of the reactor are identified by determining the intersections between simulated absorbed electron power and electron loss power curves. From the plots, transition currents between stable working points are identified and compared with experimentally measured values. Study of hysteresis in ICPs provides better understanding of ICP formation which would be useful for reactor pressure and current optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison between experiment and simulation for argon inductively coupled plasma

In order to include the nonlocal characteristics of electrons and investigate the inductively coupled plasma (ICP) resources more completely, we have developed a hybrid Monte Carlo (MC)/fluid hybrid model and calculated the axial and radial distributions of electron density, electron temperature, plasma potential, and electron energy distribution functions (EEDFs) of Ar discharge in a planar ICP. Furthermore, to make the model more practical, we still incorporate the effects of metastable atoms, whose sets of rate coefficients and density are, respectively, calculated through the electron MC part and fluid module. Besides, the corresponding Langmuir probe measurements are used to compare these data to validate the simulated results. Under all the selected discharge powers and pressures, the theoretically simulated and experimentally measured quantity profiles agree reasonably with each other, embodied in the generally identical magnitude ranges and spatial distributions. Furthermore, the interpretations about their detailed differences are given, which are based on the designs of both experimental schematic and model configuration. The analysis implements that the inclusions of electron-electron collision and a neutral density distribution into the hybrid model are likely to improve the comparison between the model predictions and experiment diagnostics. Furthermore, the evolution of plasma parameters and EEDFs with discharge conditions is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A method for evaluations on the radiation trapping in an inductively coupled plasma in argon

One of the general challenges for the evaluation and interpretation of optical emission spectroscopy measurements is the occurrence of radiation trapping, which is also named self-absorption or opacity. A convenient technique to treat radiation trapping is the introduction of a parameter, which is called escape factor and gives a measure for the amount of radiation trapping. In this paper evaluations on the concept of escape factors are presented for an inductively coupled plasma in argon. Especially, the strong argon line at 811.53 nm, which arises from the transition of 2p{sub 9}-1s{sub 5}, is under consideration. To estimate escape factors for this line, a particular method is proposed and presented here. First experimental results are obtained under the restrictive assumptions that transitions into the resonant levels 1s{sub 2} and 1s{sub 4} are sufficiently optically thin and ratios of population densities are constant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of simultaneous source and bias pulsing in inductively coupled plasma etching

Pulsed rf plasmas show promise to overcome challenges for plasma etching at future technological nodes. In pulsed plasmas, it is important to characterize the transient phenomena to optimize plasma processing of materials. In particular, it is important to evaluate the effect of the ion energy and angular distribution (IEAD) functions during pulsing on etching of nanoscale features. In this work, the impact of simultaneous pulsing of both source and bias in an inductively coupled plasma on plasma characteristics and feature profile evolution is discussed using results from a two-dimensional reactor scale plasma model coupled to a Monte Carlo based feature profile model. Results are discussed for an Ar/Cl{sub 2} gas mixture which is typically used for poly-Si etching. The consequences of duty cycle, pulse shape, and the phase lag between source and bias power pulses on discharge characteristics, IEADs to the wafer, and feature profile evolution are discussed. The low plasma density during the initial period of the pulse was found to introduce a high energy tail component to the IEADs. This high energy tail component can be affected by modifying the pulse shape. The Si etching rate is found to increase with increasing duty cycle but is lower compared to continuous mode of operation due to lower time averaged power deposition. Pulsing the source and bias out of phase provides for increased ion energies and fluxes to the wafer for a given duty cycle.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Low energy electron heating and evolution of the electron energy distribution by diluted O{sub 2} in an inductive Ar/O{sub 2} mixture discharge

A remarkable increase in electron temperature with diluted O{sub 2} gas was observed in a low pressure Ar/O{sub 2} mixture inductive discharge from the measurement of the electron energy distribution function (EEDF). At a pure Ar gas discharge of 3 mTorr and 100 W, the measured EEDF had a bi-Maxwellian distribution with two electron temperature groups. However, as the O{sub 2} flow rate increased with fixing total gas pressure, a significant increase in the low energy electron temperature was observed. Finally, the EEDF evolved from a bi-Maxwellian to a Maxwellian distribution. These results can be understood by an efficient low energy electron heating from both an enhanced collisionless and a collisional heating mechanism because of increases of both skin depth and the elastic collision with the non-Ramsauer gas, O{sub 2}. These experiments were also studied with different ICP power and Ar/He mixture.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Input impedance of a powerful single-core ferromagnetic inductively coupled plasma source

An experimental study of the recently developed version of the ferromagnetic inductively coupled plasma source has shown that under certain circumstances its input impedance becomes almost independent of the delivered rf driving power and (therefore) of the produced plasma density. This plasma source consists of a large ferromagnetic core, which is fully immersed in plasma. This core is surrounded by a primary winding and plasma appears due to gas discharge driven by an rf voltage applied to this primary winding. We have found values of parameters which determine the input impedance in such an ''independent'' regime and derived a quantitative theory which is in good agreement with the measured impedance values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental observation of the transition from nonlocal to local electron kinetics in inductively coupled plasmas

The transition from nonlocal to local kinetics was observed through the spatially resolved measurements of electron energy distribution functions in inductively coupled plasmas. As gas pressures increase, the spatial profiles of the effective electron temperatures (T{sub eff}) from the electron energy distribution functions changed dramatically from hollow shapes to flat shapes. With further increases in gas pressures, the T{sub eff} had saddle-shaped profiles with the highest T{sub eff} in the vicinity of an antenna coil. These changes in the radial profiles of the T{sub eff} show a transition of the electron kinetics from nonlocal to local regimes. This transition occurred when the electron energy relaxation lengths became smaller than the antenna half size.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of the electron energy distribution and E-H mode transition in inductively coupled nitrogen plasma

Electron energy distribution function (EEDF) measurements were conducted in nitrogen gas inductively coupled plasma (ICP). At a low ICP power (capacitive mode) and a high gas pressure, the measured EEDF had an unusual distribution with a hole near this electron energy of 3 eV. This distribution is primarily due to vibrational excitation collisions because the vibrational cross section has a sharp peak at the electron energy in nitrogen gas. However, the EEDF evolved into a Maxwellian distribution and the hole disappeared, when the discharge mode transition from E mode to H mode occurred. This evolution of the EEPF can be understood by the electron-electron collision effect, and it occurs when the electron-electron collision time become shorter than the electron residence time.