Sparse Superpixel Unmixing for Exploratory Analysis of CRISM Hyperspectral Images

Fast automated analysis of hyperspectral imagery can inform observation planning and tactical decisions during planetary exploration. Products such as mineralogical maps can focus analysts' attention on areas of interest and assist data mining in large hyperspectral catalogs. In this work, sparse spectral unmixing drafts mineral abundance maps with Compact Reconnaissance Imaging Spectrometer (CRISM) images from the Mars Reconnaissance Orbiter. We demonstrate a novel "superpixel" segmentation strategy enabling efficient unmixing in an interactive session. Tests correlate automatic unmixing results based on redundant spectral libraries against hand-tuned summary products currently in use by CRISM researchers.

Image Segmentation↗

Smart Cameras for Remote Science Survey

Communication with remote exploration spacecraft is often intermittent and bandwidth is highly constrained. Future missions could use onboard science data understanding to prioritize downlink of critical features [1], draft summary maps of visited terrain [2], or identify targets of opportunity for followup measurements [3]. We describe a generic approach to classify geologic surfaces for autonomous science operations, suitable for parallelized implementations in FPGA hardware. We map these surfaces with texture channels - distinctive numerical signatures that differentiate properties such as roughness, pavement coatings, regolith characteristics, sedimentary fabrics and differential outcrop weathering. This work describes our basic image analysis approach and reports an initial performance evaluation using surface images from the Mars Exploration Rovers. Future work will incorporate these methods into camera hardware for real-time processing.

robotics↗

Image registration with uncertainty analysis

In an image registration method, edges are detected in a first image and a second image. A percentage of edge pixels in a subset of the second image that are also edges in the first image shifted by a translation is calculated. A best registration point is calculated based on a maximum percentage of edges matched. In a predefined search region, all registration points other than the best registration point are identified that are not significantly worse than the best registration point according to a predetermined statistical criterion.

97 MATHEMATICS AND COMPUTING↗

Kernels for scalable data analysis in science: Towards an architecture-portable future

In this paper, we pose and address some of the unique challenges in the analysis of scientific Big Data on supercomputing platforms. Our approach identifies, implements and scales numerical kernels that are critical to the instantiation of theory-inspired analytic workflows on modern computing architectures. We present the benefits of scalable kernels towards constructing algorithms such as principal component analysis and non-negative matrix factorization on an image-analysis use case at the Oak Ridge Leadership Computing Facility (OLCF). Based on experience with the use-case, we conclude that piecing scalable analytic kernels into user-defined analytic workflows are a flexible, modular and agile way to enable architecture-portable productivity for the data-intensive sciences.

Sukumar, Sreenivas R.↗

SU-E-J-209: Verification of 3D Surface Registration Between Stereograms and CT Images

Purpose: Stereography can provide a visualization of the skin surface for radiation therapy patients. The aim of this study was to verify the registration algorithm in a commercial image analysis software, 3dMDVultus, for the fusion of stereograms and CT images. Methods: CT and stereographic scans were acquired of a head phantom and a deformable phantom. CT images were imported in 3dMDVultus and the surface contours were generated by threshold segmentation. Stereograms were reconstructed in 3dMDVultus. The resulting surfaces were registered with Vultus algorithm and then exported to in-house registration software and compared with four algorithms: rigid, affine, non-rigid iterative closest point (ICP) and b-spline algorithm. RMS (root-mean-square residuals of the surface point distances) error between the registered CT and stereogram surfaces was calculated and analyzed. Results: For the head phantom, the maximum RMS error between registered CT surfaces to stereogram was 6.6 mm for Vultus algorithm, whereas the mean RMS error was 0.7 mm. For the deformable phantom, the maximum RMS error was 16.2 mm for Vultus algorithm, whereas the mean RMS error was 4.4 mm. Non-rigid ICP demonstrated the best registration accuracy, as the mean of RMS errors were both within 1 mm. Conclusion: The accuracy of registration algorithm in 3dMDVultus was verified and exceeded RMS of 2 mm for deformable cases. Non-rigid ICP and b-spline algorithms improve the registration accuracy for both phantoms, especially in deformable one. For those patients whose body habitus deforms during radiation therapy, more advanced nonrigid algorithms need to be used.

60 APPLIED LIFE SCIENCES↗

SU-E-T-04: 3D Printed Patient-Specific Surface Mould Applicators for Brachytherapy Treatment of Superficial Lesions

Purpose: Evaluate the feasibility of constructing 3D-printed patient-specific surface mould applicators for HDR brachytherapy treatment of superficial lesions. Methods: We propose using computer-aided design software to create 3D printed surface mould applicators for brachytherapy. A mould generation module was developed in the open-source 3D Slicer ( http://www.slicer.org ) medical image analysis platform. The system extracts the skin surface from CT images, and generates smooth catheter paths over the region of interest based on user-defined start and end points at a specified stand-off distance from the skin surface. The catheter paths are radially extended to create catheter channels that are sufficiently wide to ensure smooth insertion of catheters for a safe source travel. An outer mould surface is generated to encompass the channels. The mould is also equipped with fiducial markers to ensure its reproducible placement. A surface mould applicator with eight parallel catheter channels of 4mm diameters was fabricated for the nose region of a head phantom; flexible plastic catheters of 2mm diameter were threaded through these channels maintaining 10mm catheter separations and a 5mm stand-off distance from the skin surface. The apparatus yielded 3mm thickness of mould material between channels and the skin. The mould design was exported as a stereolithography file to a Dimension SST1200es 3D printer and printed using ABS Plus plastic material. Results: The applicator closely matched its design and was found to be sufficiently rigid without deformation during repeated application on the head phantom. Catheters were easily threaded into channels carved along catheter paths. Further tests are required to evaluate feasibility of channel diameters smaller than 4mm. Conclusion: Construction of 3D-printed mould applicators show promise for use in patient specific brachytherapy of superficial lesions. Further evaluation of 3D printing techniques and materials is required for constructing sufficiently thin, rigid and durable surface moulds suitable for clinical deployment.

60 APPLIED LIFE SCIENCES↗

Poster - 10: QA of Ultrasound Images for Prostate Brachytherapy

Purpose: The current QA protocol of ultrasound systems used in prostate brachytherapy (TG128) addresses geometrical verifications, but the scope of evaluation of image quality is limited. We recognized importance of the latter in routine practice, and designed a protocol for QA of the images. Methods: Images of an ultrasound prostate phantom (CIRS053) were collected with BK Flex Focus 400. The images were saved as bmp after adjusting the gain to 50% for consistent results. Mean pixel values and signal to noise ratio were inspected in the representative sections of the phantom, including the mock prostate and the unechoic medium. Constancy of these numbers over a one year period was looked at. Results: The typical intensity in the mock prostate region in the transverse images ranged between 95 and 118 (out of 256), and the signal to noise was about 10. The intensity in the urethra region was about 170±40, and the unechoic medium was 2±2. The mean and the signal to noise ratio remained almost unchanged after a year, while the signal in the unechoic medium increased to about 7±4. Similar values were obtained in the sagittal images. Conclusions: The image analysis discussed above allows quick evaluation of constancy of the image quality. This may be also useful in troubleshooting image-quality problems during routine exams, which might not be due to deterioration of the US system, but other reasons, e.g. variations in tissue properties or air being trapped between the probe and the anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localization of polyhydroxybutyrate in sugarcane using Fourier-transform infrared microspectroscopy and multivariate imaging

Background: Slow-degrading, fossil fuel-derived plastics can have deleterious effects on the environment, especially marine ecosystems. The production of bio-based, biodegradable plastics from or in plants can assist in supplanting those manufactured using fossil fuels. Polyhydroxybutyrate (PHB) is one such biodegradable polyester that has been evaluated as a possible candidate for relinquishing the use of environmentally harmful plastics. Results: PHB, possessing similar properties to polyesters produced from non-renewable sources, has been previously engineered in sugarcane, thereby creating a high-value co-product in addition to the high biomass yield. This manuscript illustrates the coupling of a Fourier-transform infrared microspectrometer, equipped with a focal plane array (FPA) detector, with multivariate imaging to successfully identify and localize PHB aggregates. Principal component analysis imaging facilitated the mining of the abundant quantity of spectral data acquired using the FPA for distinct PHB vibrational modes. PHB was measured in the chloroplasts of mesophyll and bundle sheath cells, acquiescent with previously evaluated plant samples. Conclusion: This study demonstrates the power of IR microspectroscopy to rapidly image plant sections to provide a snapshot of the chemical composition of the cell. While PHB was localized in sugarcane, this method is readily transferable to other value-added co-products in different plants.

36 MATERIALS SCIENCE↗

Drag Reducing and Cavitation Resistant Coatings

Client, Green Building Systems (GBS), presented PNNL a coating reported to reduce drag and prevent cavitation damage on marine vessels, turbines and pumps. The composition of the coating remains proprietary but has as constituents including silicon oxides, aliphatic carbon chains, and fluorine rich particles. The coating is spray applied to surfaces. Prior GBS testing and experiments suggest reduction of both drag and cavitation on industrial scale propellers, but the underlying mechanism for these effects remains unclear. Yet, the application is compelling because even modest reductions in drag to marine vessels and cavitation to propellers and turbines present a significant economic and environmental opportunity. To discern among possible mechanisms, PNNL considered possible mechanisms with the client, executed multiple experiments, and completed one theoretical analysis (see appendix). The remainder of this report first considers image analysis to gain insight into drag reduction mechanisms and then exposes the coating to cavitation to explore its response to an intensely cavitating environment. Although further efforts may be warranted to confirm mechanisms, this report presents a first investigation into these coatings within the scope and resources of the technology assistance program (TAP).

36 MATERIALS SCIENCE↗

Quality Control Methods for Measurement of UCO Kernel Composition and SiC Microstructure

Quality control (QC) is critically important to tristructural-isotropic (TRISO) particle fuels owing to the complexity of and reliance on the fuel form to contain fission products during irradiation. Characterization methods for particle fuel QC have decades of history and have continued to develop as new insights into fuel performance inform revised fuel specifications and as advances in underlying technologies expand the possibilities of what may be characterized. Two relatively new methods for characterization of TRISO fuels have been published in open literature: optical microscopy image analysis for mixed uranium carbide/uranium oxide (UCO) kernel composition analysis and automated grain boundary detection in backscattered electron (BSE) images of the silicon carbide (SiC) layer in TRISO particles for grain size characterization. Suggestions and guidelines for the application of these methods to TRISO fuel qualification are provided in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Land image data processing requirements for the EOS era

Requirements are proposed for a hybrid approach to image analysis that combines the functionality of a general-purpose image processing system with the knowledge representation and manipulation capabilities associated with expert systems to improve the productivity of scientists in extracting information from remotely sensed image data. The overall functional objectives of the proposed system are to: (1) reduce the level of human interaction required on a scene-by-scene basis to perform repetitive image processing tasks; (2) allow the user to experiment with ad hoc rules and procedures for the extraction, description, and identification of the features of interest; and (3) facilitate the derivation, application, and dissemination of expert knowledge for target recognition whose scope of application is not necessarily limited to the image(s) from which it was derived.

Wharton, Stephen W.↗

Statistical characterization of experimental magnetized liner inertial fusion stagnation images using deep-learning-based fuel–background segmentation

Significant variety is observed in spherical crystal x-ray imager (SCXI) data for the stagnated fuel–liner system created in Magnetized Liner Inertial Fusion (MagLIF) experiments conducted at the Sandia National Laboratories Z-facility. As a result, image analysis tasks involving, e.g., region-of-interest selection (i.e. segmentation), background subtraction and image registration have generally required tedious manual treatment leading to increased risk of irreproducibility, lack of uncertainty quantification and smaller-scale studies using only a fraction of available data. We present a convolutional neural network (CNN)-based pipeline to automate much of the image processing workflow. This tool enabled batch preprocessing of an ensemble of N scans = 139 SCXI images across N exp = 67 different experiments for subsequent study. The pipeline begins by segmenting images into the stagnated fuel and background using a CNN trained on synthetic images generated from a geometric model of a physical three-dimensional plasma. The resulting segmentation allows for a rules-based registration. Our approach flexibly handles rarely occurring artifacts through minimal user input and avoids the need for extensive hand labelling and augmentation of our experimental dataset that would be needed to train an end-to-end pipeline. Here we also fit background pixels using low-degree polynomials, and perform a statistical assessment of the background and noise properties over the entire image database. Our results provide a guide for choices made in statistical inference models using stagnation image data and can be applied in the generation of synthetic datasets with realistic choices of noise statistics and background models used for machine learning tasks in MagLIF data analysis. We anticipate that the method may be readily extended to automate other MagLIF stagnation imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoabsorption Imaging at Nanometer Scales Using Secondary Electron Analysis

Optical imaging with nanometer resolution offers fundamental insights into light–matter interactions. Traditional optical techniques are diffraction limited with a spatial resolution >100 nm. Optical super-resolution and cathodoluminescence techniques have higher spatial resolutions, but these approaches require the sample to fluoresce, which many materials lack. Here, we introduce photoabsorption microscopy using electron analysis, which involves spectrally specific photoabsorption that is locally probed using a scanning electron microscope, whereby a photoabsorption-induced surface photovoltage modulates the secondary electron emission. We demonstrate spectrally specific photoabsorption imaging with sub-20 nm spatial resolution using silicon, germanium, and gold nanoparticles. Theoretical analysis and Monte Carlo simulations are used to explain the basic trends of the photoabsorption-induced secondary electron signal. Based on our current experiments and this analysis, we expect that the spatial resolution can be further improved to a few nanometers, thereby offering a general approach for nanometer-scale optical spectroscopic imaging and material characterization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterizing Detailed Grain Shape and Size Distribution Properties of Lunar Regolith

Introduction: As the nation prepares to return to the Moon, there is an increasing need for testing tools, instruments, and equipment in simulated environments on Earth to ensure successful operations during lunar missions. Regolith will affect all aspects of future lunar missions, from plume interactions during landing to space suit and tool design [1]. Because of this, it is important to understand the grain shape and size properties of lunar regolith and how those influence regolith behavior in order to prepare for these missions. This knowledge is also vital to create more accurate lunar regolith simulants for testing equipment in a lunar environment. While particle size analyses have been performed on most Apollo soils using simple sieving, shape has only been crudely addressed [2]. This work analyzes 4 lunar regolith samples to provide a better understanding of these size and shape parameters and will provide a more accurate baseline of data to create high-fidelity lunar regolith simulants. Methods: New technologies exist today that are capable of measuring size and shape simultaneously for hundreds of thousands of particles in a single measurement. We conducted a rigorous analysis of the particle size distribution (PSD) as well as the size-dependent 2D and 3D shape parameters of lunar regolith samples of different compositions and maturity levels. This analysis was done using a Microtrac SYNC which provides a unique combination of tri-laser diffraction and Dynamic Image Analysis (DIA). Sample Selection. Four regolith samples were selected for analysis based on maturity level and lunar terrain type: • 10084 – Mature high-Ti mare regolith • 15601 – Immature low-Ti mare regolith • 64501 – Mature highland regolith • 67461 – Immature highland regolith Sample Analysis. After receiving the samples, each sample was imaged with an optical microscope (Figure 1). To obtain 2D and 3D particle size and shape, 0.1 g of each sample was then added to the SYNC for analysis, which outputs more than 30 size and shape parameters for each individual grain as well as the complete size distribution from 0.01-2000 μm by blending laser diffraction and DIA together. For the 0.1 g sample masses requested, ~100,000 grains per sample were captured by DIA. Results: From the PSD analysis, it can be seen that the average particle size of 10084 is ~24.5 µm which is much smaller than the average particle size of the Apollo sample collection (~72 µm) [3], while the average particle size of samples 15601, 64501, and 67461 are larger than the Apollo sample average at ~106 µm, ~103 µm, and ~118.5 µm respectively. The size and shape measurements for the samples output ~30 parameters, four of which were focused on for this study: sphericity, aspect ratio, roundness, and concavity (Figure 3). However, after analyzing the plots it was found that only sphericity and aspect ratio showed differences between the samples. These two parameters are measured on a scale from 0 to 1, with 1 being a perfect sphere with equal dimensions. The results show that the sphericity values are slightly high-er for the mature samples 10084 and 64501 (~0.96) than they are for samples 15601 and 67461 (~0.95) (Figure 4). The aspect ratio values are slightly lower for samples 64501 (~0.7) and 67461 (~0.74) than they are for samples 10084 (~0.76) and 15601 (~0.8) (Figure 5). Discussion: Mature regoliths are those that have been exposed to micrometeorite and solar wind bombardment for long periods of time, breaking up particles and causing them to become more rounded [4]. Therefore, the smaller particle sizes and higher sphericity values for samples 10084 and 64501 are expected due to their higher maturity level compared to 15601 and 67461. However, the aspect ratio values are not dependent on maturity and are instead dependent on terrain type. The lower aspect ratio values for the high-land samples is potentially due to the higher plagioclase content, which occurs in elongated particles and does not break down as easily as the pyroxenes or olivines that are present in the mare. Conclusion and Future Work: The results of this work provide a baseline of high-quality data that will contribute to the creation of high-fidelity lunar simulants and will greatly benefit NASA’s efforts of establishing a human presence on the Moon. Future work includes performing unsupervised image classification on the ~105 particle images per sample in order to identify different classes of grains. These grain classes can then be linked to detailed shape properties, and the relative abundance of each class in the samples can be compared. Acknowledgments: We would like to thank the Extraterrestrial Materials Analysis Group (ExMAG) and the Astromaterials Allocation Review Board (AARB) for allocating lunar regolith samples 10084,9010, 15601,365, 64501,249, and 67461,171 for this work. References: [1] Taylor, L. A. et al. (2005) AIAA #2510. [2] Katagiri et al. (2015) ASCE. [3] Carrier III, W. D. (2005) Lunar Geotech Institute Tech Report. [4] McKay, D. S. et al. (1991) The Lunar Sourcebook, Chapter 7.

S R Deitrick↗

Helium Ion Microscopy

Nanotechnology research led to the development of various instruments to be used for imaging or fabrication. The helium ion microscope (HIM) became available in 2006 but quickly gained popularity. Its unique gas field ion source enables high-resolution imaging, nanofabrication, direct write, and the recent combination with a secondary ion mass spectrometer offers chemical imaging with ~15 nm resolution. Particularly attractive are the small interaction volume of He and Ne (the two gases offered), small beam spot size, and a moderate sputtering rate. Additionally, the HIM is an excellent imaging tool for insulating samples in soft, polymeric, and biological materials. It can be expected that helium ion microscopy will continue to have a strong influence on broad range of scientific disciplines, including chemistry, materials science, and biology.This chapter aims at providing an overview of the current status of HIM for imaging, analysis, and nanofabrication. It introduces the reader to key components of the instrument, theoretical background, and latest results in the areas of imaging, material fabrication, and chemical analysis capabilities of helium ion microscopy.

Belianinov, Alex↗

Spectral analysis of mammographic images using a multitaper method

Purpose: Power spectral analysis in radiographic images is conventionally performed using a windowed overlapping averaging periodogram. This study describes an alternative approach using a multitaper technique and compares its performance with that of the standard method. This tool will be valuable in power spectrum estimation of images, whose content deviates significantly from uniform white noise. The performance of the multitaper approach will be evaluated in terms of spectral stability, variance reduction, bias, and frequency precision. The ultimate goal is the development of a useful tool for image quality assurance. Methods: A multitaper approach uses successive data windows of increasing order. This mitigates spectral leakage allowing one to calculate a reduced-variance power spectrum. The multitaper approach will be compared with the conventional power spectrum method in several typical situations, including the noise power spectra (NPS) measurements of simulated projection images of a uniform phantom, NPS measurement of real detector images of a uniform phantom for two clinical digital mammography systems, and the estimation of the anatomic noise in mammographic images (simulated images and clinical mammograms). Results: Examination of spectrum variance versus frequency resolution and bias indicates that the multitaper approach is superior to the conventional single taper methods in the prevention of spectrum leakage and variance reduction. More than four times finer frequency precision can be achieved with equivalent or less variance and bias. Conclusions: Without any shortening of the image data length, the bias is smaller and the frequency resolution is higher with the multitaper method, and the need to compromise in the choice of regions of interest size to balance between the reduction of variance and the loss of frequency resolution is largely eliminated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Significance of operator variation and the angle of illumination in lineament analysis on synoptic images

The significance of operator variation and the angle of illumination in acquired imagery is analyzed for lineament analysis. Five operators analyzed a LANDSAT image and four photographs of a plastic relief map illuminated at a low angle from varying directions of the Prescott, Arizona region. Significant differences were found in both number and length of the lineaments recognized by the different investigators for the images. The actual coincidence of lineaments recognized by the investigators for the same image is exceptionally low. Even the directional data on lineament orientation is significantly different from operator to operator and from image to image. Cluster analysis of the orientation data displays a clustering by operators rather than by images. It is recommended that extreme caution be taken before attempting to compare different investigators' results in lineament analysis.

Siegal, B. S.↗

A novel computer-aided lung nodule detection system for CT images

Purpose: The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. Methods: The CAD system was trained and tested on images from the publicly available Lung Image Database Consortium (LIDC) on the National Cancer Institute website. The detection stage of the system consists of a nodule segmentation method based on nodule and vessel enhancement filters and a computed divergence feature to locate the centers of the nodule clusters. In the subsequent classification stage, invariant features, defined on a gauge coordinates system, are used to differentiate between real nodules and some forms of blood vessels that are easily generating false positive detections. The performance of the novel feature-selective classifier based on genetic algorithms and artificial neural networks (ANNs) is compared with that of two other established classifiers, namely, support vector machines (SVMs) and fixed-topology neural networks. A set of 235 randomly selected cases from the LIDC database was used to train the CAD system. The system has been tested on 125 independent cases from the LIDC database. Results: The overall performance of the fixed-topology ANN classifier slightly exceeds that of the other classifiers, provided the number of internal ANN nodes is chosen well. Making educated guesses about the number of internal ANN nodes is not needed in the new feature-selective classifier, and therefore this classifier remains interesting due to its flexibility and adaptability to the complexity of the classification problem to be solved. Our fixed-topology ANN classifier with 11 hidden nodes reaches a detection sensitivity of 87.5% with an average of four false positives per scan, for nodules with diameter greater than or equal to 3 mm. Analysis of the false positive items reveals that a considerable proportion (18%) of them are smaller nodules, less than 3 mm in diameter. Conclusions: A complete CAD system incorporating novel features is presented, and its performance with three separate classifiers is compared and analyzed. The overall performance of our CAD system equipped with any of the three classifiers is well with respect to other methods described in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗