Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Development of Thermal Tomography Imaging System for In-Service Nondestructive Evaluation of Additively Manufactured Components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. We investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin. MIT research reactor (MITR) has been identified as a representative environment to perform investigation of feasibility of in-service NDE during shutdown. Preliminary study of radiation level in the MITR viewport, with geometric parameters potentially compatible with compact TT system, has been conducted.

36 MATERIALS SCIENCE↗

Design and Implementation of an In?Cache Archival Entropy Coder for the Sonoma Persistent Surveillance System

The Sonoma sensor, developed at Lawrence Livermore National Laboratory, is an electro-optical (EO) sensor composed of a tiled arrangement of cameras, where each camera sends 20 megabytes (MB) of raw data per frame. Depending on the sensor configuration, each sensor image, in aggregate, can total up to 320 MB. I discuss here the design and implementation of a high-speed entropy coder utilizing the Lead-1 encoding method, intended to quickly and losslessly compress sensor data before it is written to storage. More sophisticated (and slower) compression techniques may be performed off-line. The coder, favoring speed over coding efficiency, is simple in principle and tiny in practice: the amount of allocated memory required by the coder can be as small as 26 bytes. On a 2.7 GHz PowerMac G5 this coder is capable of encoding sensor data at a rate of 163 megabytes per second. The overall compression rate is better than that of BZIP2, GZIP, and a range coder, and the total execution speed is superior.

99 GENERAL AND MISCELLANEOUS↗

Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams

In this study, the authors investigated the feasibility of using a 3D liquid scintillator (LS) detector system for the verification and characterization of proton beams in real time for intensity and energy-modulated proton therapy. A plastic tank filled with liquid scintillator was irradiated with pristine proton Bragg peaks. Scintillation light produced during the irradiation was measured with a CCD camera. Acquisition rates of 20 and 10 frames per second (fps) were used to image consecutive frame sequences. These measurements were then compared to ion chamber measurements and Monte Carlo simulations. The light distribution measured from the images acquired at rates of 20 and 10 fps have standard deviations of 1.1% and 0.7%, respectively, in the plateau region of the Bragg curve. Differences were seen between the raw LS signal and the ion chamber due to the quenching effects of the LS and due to the optical properties of the imaging system. The authors showed that this effect can be accounted for and corrected by Monte Carlo simulations. The liquid scintillator detector system has a good potential for performing fast proton beam verification and characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Room PET Scanner for Natural Environment Neuroscience Research

A room size PET scanner for neuroscience research is proposed in which subjects can move about freely in a natural environment. This scanner, termed RoomPET, would open new frontiers in the study of dynamic brain function. The key to a feasible system is PET detectors with a limited vertical dimension that may translate up and down to keep the brain in the field of view. Head position can be tracked by an array of video cameras, providing real-time data to guide detector motion and for motion-corrected image reconstruction. For a point in the center of the room and centered within the vertical field of view of the detectors, geometric sensitivity ranges between 4 and 18% for room widths of 2 to 3 m and detectors with vertical dimensions of 15 to 40 cm. Spatial resolution is dominated by annihilation photon non-colinearity due to the large detector separation. This non-colinearity contribution for F-18 is 4.4 and 6.6 mm full width at half maximum (FWHM) at the center of 2 ×2 and 3×3m 2 rooms, respectively, for a line of response orthogonal to the opposite walls. With pixelated scintillation crystal elements 2 mm on a side the system resolution for F-18 radiotracers is estimated at 4.5 and 6.7 mm FWHM for room widths of 2 and 3 m, respectively. A RoomPET system would advance the understanding of brain function in healthy humans and in those with neurological diseases, disorders and brain injury.

Smith, Mark F.↗

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

NucD-23 Nuclear Diagnostics Development: The future of neutron imaging and gamma reaction history

The Neutron Imaging team has deployed novel, active detection systems along two lines of sight at NIF. Studies aimed to characterize NIS sensitivity to implosion shape will be carried out to further extend reconstruction capabilities. Additionally, an improved camera timing system that will reduce uncertainties stemming from bang time jitter will also be fielded. The NIF GRH data recording system is more then 10 years old needs to be updated. Bandwidth and noise are a key limiting factor for improving data quality. New high bandwidth and low noise components will be tested at OMEGA in advance before fielding the components at NIF.

42 ENGINEERING↗

Development of an IAEA Training Course for Future U.S. Inspectors

U.S. citizens currently make up only 12% of the positions held in the IAEA’s Department of Safeguards. While the United States has maintained a high level of support for the Agency over the duration of its history, the number of American inspectors currently in the field does not reflect this level of involvement. As a result, the National Nuclear Security Administration’s Office of International Relations, as part of the Next Generation Safeguards Initiative (NGSI) mission, has tasked Idaho National Laboratory (INL) to develop a rigorous two week hands-on training program to encourage and operationally acclimatize U.S. Citizens who are interested in applying for IAEA inspector positions using IAEA authorized equipment at INL. Idaho National Laboratory is one-of-a-kind in its ability to train IAEA inspectors by including training at nuclear facilities on site and includes, for example, direct measurement of an active spent fuel storage cooling pond. This accredited course will introduce and train attendees on the major IAEA systems used in collecting nuclear safeguards data and performing safeguards inspections. Unique in the United States, these classes will give attendees direct hands-on training and will address equipment purpose, function, operating principles, application, and troubleshooting, based upon what would be expected of an IAEA Safeguards Inspector in the field and in the office. Upon completion, U.S. applicants will be better qualified to pursue a position in the IAEA Department of Safeguards Operational Divisions. In support, INL has recently established a new laboratory space to house state of the art nuclear safeguards instrumentation. Currently, equipment installed in the laboratory space includes attended systems: 3DLR (3-D Imaging Laser) for design information verification, a Digital Cerenkov Viewing Device for measurement of spent fuel, HM-5 handheld radiation detectors, quantitative neutron and gamma systems; unattended monitoring systems including: NGAM and MiniGRAND radiation systems and a DMOS camera system, and VACOSS/EOSS Optical Sealing Systems..

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Assessment of neutron radiation damage and shielding for operational good practice of the video systems at Jet - 25426

High neutron and gamma ray yields in fusion reactors like JET can be detrimental to the applied diagnostic equipment such as video imaging systems. For instance, defects induced in semiconductors by neutrons via displacement damage effects degrade the performance of CCD image sensors. Actions to minimize and/or mitigate these effects need to be considered during operation and maintenance of the video system at JET. A preliminary study on the setting up of a neutron/gamma shield around the cameras has been pursued. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrinsic Feature Pose Measurement for Awake Animal SPECT Imaging

New developments have been made in optical motion tracking for awake animal imaging that measures 3D position and orientation (pose) for a single photon emission computed tomography (SPECT) imaging system. Ongoing SPECT imaging research has been directed towards head motion measurement for brain studies in awake, unrestrained mice. In contrast to previous results using external markers, this work extracts and tracks intrinsic features from multiple camera images and computes relative pose from the tracked features over time. Motion tracking thus far has been limited to measuring extrinsic features such as retro-reflective markers applied to the mouse s head. While this approach has been proven to be accurate, the additional animal handling required to attach the markers is undesirable. A significant improvement in the procedure is achieved by measuring the pose of the head without extrinsic markers using only the external surface appearance. This approach is currently being developed with initial results presented here. The intrinsic features measurement extracts discrete, sparse natural features from 2D images such as eyes, nose, mouth and other visible structures. Stereo correspondence between features for a camera pair is determined for calculation of 3D positions. These features are also tracked over time to provide continuity for surface model fitting. Experimental results from live images are presented.

59 BASIC BIOLOGICAL SCIENCES↗

Assembly of the Dark Energy Survey CCD Imager

The Dark Energy Camera (DECam) is the new wide field prime-focus imager for the Blanco 4m telescope at CTIO.This instrument is a 2.2 sq. deg. camera with a 45 cm diameter focal plane consisting of 62 2k × 4k CCDs and 12 2k × 2kCCDs and was developed for the Dark Energy Survey that will start operations at CTIO in 2011. DECam includes thevessel shell, the optical window cell, the CCDs with their readout electronics and vacuum interface, the focal planesupport plate and its mounts, and the cooling system and thermal controls. Assembly of the imager, alignment of thefocal plane and installation of the CCDs are described. During DECam development a full scale prototype was used formulti-CCD readout tests. This test vessel went through several stages as the CCDs and related hardware progressedfrom early prototypes to final production designs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Strain Rate Mechanical Characterization of Carbon Fiber Reinforced Polymer Composites Using Digital Image Correlations

We present that the introduction of carbon fiber reinforced polymer (CFRP) composites to structural components in lightweight automotive structures necessitates an assessment to evaluate that their crashworthiness dynamic response provides similar or higher levels of safety compared to conventional metallic structures. In order to develop, integrate and implement predictive computational models for CFRP composites that link the materials design, molding process and final performance requirements to enable optimal design and manufacturing vehicle systems for this study, the dynamic mechanical response of unidirectional (UD) and 2x2 twill weave CRFP composites was characterized at deformation rates applicable to crashworthiness performance. Non-standardized specimen geometries were tested on a standard uniaxial frame and an intermediate-to-high speed dynamic testing frame, equipped with high speed cameras for 3D digital image correlation (DIC). Specimen cross-sections, according to each fiber orientation tested, were consistent across strain rates to ensure results were comparable. Tensile strength and modulus were experimentally investigated over a wide range of strain rates (0.0001 to 200 s -1 ). DIC was used to estimate strain profiles on composites surfaces, and the modulus was calculated from those strain measurements. Experimental results demonstrated an increase in the tensile strength of UD CFRP composites in the longitudinal (0°) and transverse (90°) direction with increasing strain rates. In contrast, the tensile strength of 2x2 woven composites and the tensile modulus of the UD material were insensitive to increasing strain rates. Finally, comparison of failure modes provided insights on how loading rates influenced failure mechanisms.

36 MATERIALS SCIENCE↗

Angular-resolution and material-characterization measurements for a dual-particle imaging system with mixed-oxide fuel

A dual-particle imaging (DPI) system, capable of simultaneously imaging fast neutrons and gamma rays, has been operated in the presence of mixed-oxide (MOX) fuel to assess the system's angular resolution and material-characterization capabilities. The detection principle is based on the scattering physics of neutrons (elastic scattering) and gamma rays (Compton scattering) in organic and inorganic scintillators. The detection system is designed as a combination of a two-plane Compton camera and a neutron-scatter camera. The front plane consists of EJ-309 liquid scintillators and the back plane consists of interleaved EJ-309 and NaI(Tl) scintillators. MCNPX-PoliMi was used to optimize the geometry of the system and the resulting prototype was built and tested using a Cf-252 source as an SNM surrogate. A software package was developed to acquire and process data in real time. The software was used for a measurement campaign to assess the angular resolution of the imaging system with MOX samples. Measurements of two MOX canisters of similar isotopics and intensity were performed for 6 different canister separations (from 5° to 30°, corresponding to distances of 21 cm and 131 cm, respectively). The measurements yielded a minimum separation of 20° at 2.5 m (86-cm separation) required to see 2 separate hot spots. Additionally, the results displayed good agreement with MCNPX-PoliMi simulations. These results indicate an angular resolution between 15° and 20°, given the 5° step. Coupled with its large field of view, and its capability to differentiate between spontaneous fission and (α,n) sources, the DPI system shows its potential for nuclear-nonproliferation applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Regularization of soft-X-ray imaging in the DIII-D tokamak

We developed an image inversion scheme for the soft X-ray imaging system (SXRIS) diagnostic at the DIII-D tokamak in order to obtain the local soft X-ray emission at a poloidal cross-section from the spatially line-integrated image taken by the SXRIS camera. The scheme uses the Tikhonov regularization method since the inversion problem is generally ill-posed. The regularization technique uses the generalized singular value decomposition to determine a solution that depends on a free regularization parameter. The latter has to be chosen carefully, and the so called {\it L-curve} method to find the optimum regularization parameter is outlined. A representative test image is used to study the properties of the inversion scheme with respect to inversion accuracy, amount/strength of regularization, image noise and image resolution. Moreover, the optimum inversion parameters are identified, while the L-curve method successfully computes the optimum regularization parameter. Noise is found to be the most limiting issue, but sufficient regularization is still possible at noise to signal ratios up to 10%-15%. Finally, the inversion scheme is applied to measured SXRIS data and the line-integrated SXRIS image is successfully inverted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research and Development Toward Massive Liquid Argon Time Projection Chambers for Neutrino Detection

Liquid argon (LAr) time projection chambers (TPC) have rapidly increased in importance as particle detectors throughout the past four decades. While much research has been completed, there are still many areas which require further development to build and operate the next generation LAr TPC experiment, such as the Deep Underground Neutrino Experiment (DUNE). These include high voltage breakdown, argon purification and purity monitoring, and vacuum ultraviolet (VUV) scintillation light measurement. Visual monitoring of high voltage breakdown is helpful in allowing assessment of the performance of high voltage component design. Thus, a system of cryogenic cameras, the first of its kind, was developed for use in a large LAr cryostat, without the need for additional electronics heating. The system functioned without problem for 50 days at cryogenic temperature, with some degradation of image quality, and provided a useful monitor for the DUNE 35-ton cryogenics systems. The system did not observe any high voltage breakdowns during the run. Further development of the concept is ongoing for future installation in other experiments. The monitoring of LAr purity using TPC data is a fundamental study for LAr TPC experiments. However, the study has not been performed for a large LAr TPC in the presence of high electronic noise. Custom software was developed and validated for the accurate reconstruction of signals in noisy TPC data. The results of the reconstruction were used to successfully measure the LAr electron lifetime with an uncertainty comparable to alternate methods of measurement. The electron lifetime of the 35-ton Phase II run is determined to be 4.12 ± 0.17 (stat.) ±0.40 (syst.) ms. For general purpose research and development of high purity LAr as a particle detection medium, a dedicated test stand was designed, constructed, and commissioned. The system is used to test the gaseous photomultiplier (GPM) performance at cryogenic temperatures. The GPM functions with photoelectron multiplication at 77 K, at a reduced gain. Further study is required to show the detector’s direct sensitivity to LAr VUV scintillation light.

Thiesse, Matthew↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver (2 nd Ed)

High - temperature particle receivers are being pursued to enable next - generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 C) to enable more efficient power cycles, lower overall system costs, and emerging CSP - based process - heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera - based imaging methods were developed and applied to both laboratory - scale and larger 1 MW t on - sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle - sampling methods using volumetric particle - air samplers were applied to the on - sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3 - D printed tipping buckets and tethered balloons were also developed and applied to the on - sun particle - receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera - based imaging methods correlated well with measured values during the on - sun tests.

14 SOLAR ENERGY↗

Influencing Activity of Bats by Dimly Lighting Wind Turbine Surfaces with Ultraviolet Light

Wind energy producers need deployable devices for wind turbines that prevent bat fatalities. Based on the speculation that bats approach turbines after visually mistaking them for trees, we tested a potential light-based deterrence method. It is likely that the affected bats see ultraviolet (UV) light at low intensities. Here, we present the results of a multi-month experiment to cast dim, flickering UV light across wind turbine surfaces at night. Our objectives were to refine and test a practical system for dimly UV-illuminating turbines while testing whether the experimental UV treatment influenced the activity of bats, birds, and insects. We mounted upward-facing UV light arrays on turbines and used thermal-imaging cameras to quantify the presence and activity of night-flying animals. The results demonstrated that the turbines can be lit to the highest reaches of the blades with “invisible” UV light, and the animal responses to such experimental treatment can be concurrently monitored. The UV treatment did not significantly change nighttime bat, insect, or bird activity at the wind turbine. Our findings show how observing flying animals with thermal cameras at night can help test emerging technologies intended to variably affect their behaviors around wind turbines.

17 WIND ENERGY↗

Correcting Turbulence-induced Errors in Fiber Positioning for the Dark Energy Spectroscopic Instrument

Highly multiplexed, robotic, fiber-fed spectroscopic surveys are observing tens of millions of stars and galaxies. For many systems, accurate positioning relies on imaging the fibers in the focal plane and feeding that information back to the robotic positioners to correct their positions. Inhomogeneities and turbulence in the air between the focal plane and the imaging camera can affect the measured positions of fibers, limiting the accuracy with which fibers can be placed on targets. For the Dark Energy Spectroscopic Instrument, we dramatically reduced the effect of turbulence on measurements of positioner locations in the focal plane by taking advantage of stationary positioners and the correlation function of the turbulence. We were able to reduce positioning errors from 7.3 to 3.5 μm, speeding the survey by 1.6% under typical conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-color pyrometry imaging system and method of operating the same

A multi-color pyrometry imaging system for a high-temperature asset includes at least one viewing port in optical communication with at least one high-temperature component of the high-temperature asset. The system also includes at least one camera device in optical communication with the at least one viewing port. The at least one camera device includes a camera enclosure and at least one camera aperture defined in the camera enclosure, The at least one camera aperture is in optical communication with the at least one viewing port. The at least one camera device also includes a multi-color filtering mechanism coupled to the enclosure. The multi-color filtering mechanism is configured to sequentially transmit photons within a first predetermined wavelength band and transmit photons within a second predetermined wavelength band that is different than the first predetermined wavelength band.

42 ENGINEERING↗