Search NASA⌕ Search

SEARCH · Search NASA

Results for “Joint Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Flaw Tolerance In Lap Shear Brazed Joints

This paper presents results of the second part of an on-going effort to gain better understanding of defect tolerance in braze joints. In the first part of this three-part series, we mechanically tested and modeled the strength of the lap joints as a function of the overlap distance. A failure criterion was established based on the zone damage theory, which predicts the dependence of the lap joint shear strength on the overlap distance, based on the critical size of a finite damage zone or an overloaded region in the joint. In this second part of the study, we experimentally verified the applicability of the damage zone criterion on prediction of the shear strength of the lap joint and introduced controlled flaws into the lap joints. The purpose of the study was to evaluate the lap joint strength as a function of flaw size and its location through mechanical testing and nonlinear finite element analysis (FEA) employing damage zone criterion for definition of failure. The results obtained from the second part of the investigation confirmed that the failure of the ductile lap shear brazed joints occurs when the damage zone reaches approximately 10% of the overlap width. The same failure criterion was applicable to the lap joints containing flaws.

Wang, Len↗

The effects of inherent flaws on the time and rate dependent failure of adhesively bonded joints

Inherent flaws, as well as the effects of rate and time, are shown by tests on viscoelastic adhesive-bonded single lap joints to be as critical in joint failure as environmental and stress concentration effects, with random inherent flaws and loading rate changes resulting in an up to 40% reduction in joint strength. It is also found that the asymptotic creep stress, below which no delayed failure may occur, may under creep loading be as much as 45% less than maximum adhesive strength. Attention is given to test results for the case of titanium-LARC-3 adhesive single-lap specimens.

Sancaktar, E.↗

Development of a full-scale transmission testing procedure to evaluate advanced lubricants

Experimental tests were performed on the OH-58A helicopter main rotor transmission in the NASA Lewis 500-hp Helicopter Transmission Test Stand. The testing was part of a joint Navy/NASA/Army lubrication program. The objective of the program was to develop a separate lubricant for gearboxes and demonstrate an improved performance in life and load-carrying capacity. The goal of the experiments was to develop a testing procedure to fail certain transmission components using a MIL-L-23699 base reference oil, then run identical tests with improved lubricants and demonstrate performance. The tests were directed at failing components that the Navy has had problems with due to marginal lubrication. These failures included mast shaft bearing micropitting, sun gear and planet bearing fatigue, and spiral bevel gear scoring. A variety of tests were performed and over 900 hours of total run time accumulated for these tests. Some success was achieved in developing a testing procedure to produce sun gear and planet bearing fatigue failures. Only marginal success was achieved in producing mast shaft bearing micropitting and spiral bevel gear scoring.

Lewicki, David G.↗

An instrumented fastener for shear force measurements in joints

Results are presented of a preliminary investigation of instrumented fasteners for use as sensors to measure the shear loads transmitted by individual fasteners installed in double splice joints. Calibration and load verification tests were conducted for instrumented fasteners installed at three fastener torque levels. Calibration test results show that the shear strains obtained from the instrumented fasteners vary linearly with the applied load and that the instrumented fasteners can be effectively used to measure shear loads transmitted by individual fasteners installed in double splice joints. The load distribution between individual fasteners is found to be dependent on the location of the fastener in the joint and the fastener torque level.

Sawyer, James W.↗

Corrosion Behavior of Laser-Brazed Surface Made by Joining of AA6082 and Galvanized Steel

In the present study, a galvanized steel and a AA6082 aluminum alloy sheet of 2 mm thick were weld-brazed by applying laser and using 2-mm-diameter solid Al-12% Si filler wire at 2.5 m/min wire feed rate and 2 m/min laser scan speed at varying laser power (4.0, 3.5, 3.0 kW) in flange configuration. The microstructural investigation of the laser weld-brazed joints revealed the presence of two-layered intermetallic compound at steel/braze seam interface. The corresponding x-ray diffraction analysis of the steel/braze seam interface showed the presence of Al-Fe-Si-based ternary intermetallic phases. SEM and EDS analysis of the braze seam revealed the presence of α-Al grains surrounded by Mg{sub 2}Si phase in the grain boundary region. Fine intermetallic layer was observed at lower heat-input condition. The corrosion performance of the brazed joints was studied with the help of immersion, salt spray, and electrochemical polarization tests in different electrolytes containing NaCl salt. Brazed joints experienced galvanic corrosion during immersed in corrosive media. From the salt spray test, it was revealed that galvanized steel was highly susceptible to corrosion compared to Al-rich phase. The polarization results showed a substantial change in corrosion resistance from steel interface to the brazed region due to the variation in microstructure. The samples brazed with low heat-input showed better corrosion resistance as compared to the joints made with high heat-input. Post-corrosion microstructure revealed intergranular corrosion at the brazed joint along with pit formation.

36 MATERIALS SCIENCE↗

Flight set 360T004 (STS-30)

The performance of 360T004, Forth Flight, Redesigned Solid Rocket Motors (RSRM) is assessed in respect to joint sealing issues as seen from post-test inspection of the seals and sealing surfaces. The factory joint disassembly inspections for this flight set were omitted. The decision was based on the rational that there is sufficient information in the present data base, and this would give H-7 refurbishment operations faster turn around time for this set of hardware. The factory joint disassembly inspections will resume for 360H005, Fifth Flight, through 360L007, Seventh Flight, due to a new grease application being in effect during the assembly process. The left hand nozzle was forced into the snubbed position upon splash down. This required unique tooling to be manufactured to perform the disassembly of the internal nozzle joints. This was completed on February 5 and 6, 1990 at the H-5 Clearfield, Utah facility. The RSRM consisting of capture feature, field joints with the J-joint insulation configuration is illustrated. The nozzle-to-case joint design, which includes 100, 7/8-inch radial bolts in conjunction with a wiper O-ring and modified insulation design is also illustrated, as is the ignition system seals and a cross section of the igniter. The configuration of all internal nozzle joints is shown.

Nelsen, Lowell V.↗

Proposed Development of NASA Glenn Research Center's Aeronautical Network Research Simulator

Accurate knowledge and understanding of data link traffic loads that will have an impact on the underlying communications infrastructure within the National Airspace System (NAS) is of paramount importance for planning, development and fielding of future airborne and ground-based communications systems. Attempting to better understand this impact, NASA Glenn Research Center (GRC), through its contractor Computer Networks & Software, Inc. (CNS, Inc.), has developed an emulation and test facility known as the Virtual Aircraft and Controller (VAC) to study data link interactions and the capacity of the NAS to support Controller Pilot Data Link Communications (CPDLC) traffic. The drawback of the current VAC test bed is that it does not allow the test personnel and researchers to present a real world RF environment to a complex airborne or ground system. Fortunately, the United States Air Force and Navy Avionics Test Commands, through its contractor ViaSat, Inc., have developed the Joint Communications Simulator (JCS) to provide communications band test and simulation capability for the RF spectrum through 18 GHz including Communications, Navigation, and Identification and Surveillance functions. In this paper, we are proposing the development of a new and robust test bed that will leverage on the existing NASA GRC's VAC and the Air Force and Navy Commands JCS systems capabilities and functionalities. The proposed NASA Glenn Research Center's Aeronautical Networks Research Simulator (ANRS) will combine current Air Traffic Control applications and physical RF stimulation into an integrated system capable of emulating data transmission behaviors including propagation delay, physical protocol delay, transmission failure and channel interference. The ANRS will provide a simulation/stimulation tool and test bed environment that allow the researcher to predict the performance of various aeronautical network protocol standards and their associated waveforms under varying density conditions. The system allows the user to define human-interactive and scripted aircraft and controller models of various standards, such as (but not limited to) Very High Frequency Digital Link (VDL) of various modes.

Nguyen, Thanh C.↗

Expanding the Capability of A Legacy Combustion Flametube to Test High Temperature Engine Materials in Relevant Environments

New materials and component designs are needed to advance gas turbine engine technology and provide the performance and efficiency needs for future applications. In order to advance these materials, testing in combustion environments is a critical step prior to engine testing. In this work, we detail the design and the fabrication of a materials test sector in a flametube combustor facility. The facility simulates a combustion environment similar to that experienced by components in gas turbine engines. The flow regime is characterized by a combination of high-temperature, high-velocity, high-heat flux, and high-velocity that components experience in gas turbine engines. Exposure of components in this facility allows for the study of combined environmental effects and the impact on both coating and substrate durability. The test facility may operate across a wide range of pressures from 275-400 psig (1,896-2,758 kPa) and an air flow rate of 5 lb/s (2.27 kg/s). While combustion gas temperature is expected in excess of 3,000°F (1,649°C), 900°F (482°C) cooling air may be supplied to the backside of components or test articles. The flametube combustor was previously used to evaluate fuel injectors and combustion products, and the new test configuration will also allow for materials exposure to complex, engine-like conditions. The interior of the Test Section was additively manufactured from GRCop-84 and cryogenically fit and brazed to a stainless steel 304 housing. The use of a copper liner minimizes welds and with active cooling, is expected to provide better durability over traditional hardware using stainless steel or Inconel with a ceramic liner. The Test Section has two opposing removable windows approximately 230 mm x 80 mm that can accommodate articles up to 85 mm tall. This modular design allows for custom platforms to hold coupons, panels, or airfoil shapes to be tested with minimal re-engineering or fabrication. The bolted joint and sealing remains consistent, so any new testing only needs to work within the existing design footprint. This paper will provide an overview of the facility capabilities, design considerations, as well as thermal and structural analysis of the hardware. Future testing of ceramic matrix composite (CMC) airfoils and advanced environmental barrier coatings (EBCs) will also be discussed.

Combustion↗

On-Wafer Testing of Circuits Through 220 GHz

We have jointly developed the capability to perform on-wafer s-parameter and noise figure measurements through 220 GHz. S-parameter test sets have been developed covering full waveguide bands of 90-140 GHz (WR-08) and 140-220 GHz (WR-05). The test sets have been integrated with coplanar probes to allow accurate measurements on-wafer. We present the design and performance of the test sets and wafer probes. We also present calibration data as well as measurements of active circuits at frequencies as high as 215 GHz.

Gaier, Todd↗

Technical Evaluation Motor no. 5 (TEM-5)

Technical Evaluation Motor No. 5 (TEM-5) was static test fired at the Thiokol Corporation Static Test Bay T-97. TEM-5 was a full scale, full duration static test fire of a high performance motor (HPM) configuration solid rocket motor (SRM). The primary purpose of TEM static tests is to recover SRM case and nozzle hardware for use in the redesigned solid rocket motor (RSRM) flight program. Inspection and instrumentation data indicate that the TEM-5 static test firing was successful. The ambient temperature during the test was 41 F and the propellant mean bulk temperature (PMBT) was 72 F. Ballistics performance values were within the specified requirements. The overall performance of the TEM-5 components and test equipment was nominal. Dissembly inspection revealed that joint putty was in contact with the inner groove of the inner primary seal of the ignitor adapter-to-forward dome (inner) joint gasket; this condition had not occurred on any previous static test motor or flight RSRM. While no qualification issues were addressed on TEM-5, two significant component changes were evaluated. Those changes were a new vented assembly process for the case-to-nozzle joint and the installation of two redesigned field joint protection systems. Performance of the vented case-to-nozzle joint assembly was successful, and the assembly/performance differences between the two field joint protection system (FJPS) configurations were compared.

Cook, M.↗

Flaw Tolerance in Lap Shear Brazed Joints

Furnace brazing is a joining process used in the aerospace and other industries to produce strong permanent and hermetic structural joints. As in any joining process, brazed joints have various imperfections and defects. At the present time, our understanding of the influence of the internal defects on the strength of the brazed joints is not adequate. The goal of this 3-part investigation is to better understand the properties and failure mechanisms of the brazed joints containing defects. This study focuses on the behavior of the brazed lap shear joints because of their importance in manufacturing aerospace structures. In Part 1, an average shear strength capability and failure modes of the single lap joints are explored. Stainless steel specimens brazed with pure silver are tested in accordance with the AWS C3.2 standard. Comparison of the failure loads and the ultimate shear strength with the Finite Element Analysis (FEA) of the same specimens as a function of the overlap widths shows excellent correlation between the experimental and calculated values for the defect-free lap joints. A damage zone criterion is shown to work quite well in understanding the failure of the braze joints. In Part 2, the findings of the Part 1 will be verified on the larger test specimens. Also, various flaws will be introduced in the test specimens to simulate lack of braze coverage in the lap joints. Mechanical testing and FEA will be performed on these joints to verify that behavior of the flawed ductile lap joints is similar to joints with a reduced braze area. Finally, in Part 3, the results obtained in Parts 1 and 2 will be applied to the actual brazed structure to evaluate the load-carrying capability of a structural lap joint containing discontinuities. In addition, a simplified engineering procedure will be offered for the laboratory testing of the lap shear specimens.

Flom, Yury↗

Corrosion behaviour of friction-bit-joined and weld-bonded AA7075-T6/galvannealed DP980

Joining of aluminium alloys 7075-T6 and galvannealed dual phase 980 steel was achieved by friction bit joining (FBJ) and weld-bonding (FBJ + adhesive) processes. Accelerated laboratory-scale corrosion tests were performed on both FBJ only and weld-bonded specimens to study joint strength under a corrosive environment. Static lap shear tests showed that both FBJ only and weld-bonded cases generally retained more than 80% of the joint strength of non-corroded specimens at the end of corrosion testing. The presence of Zn/Fe coating on the steel substrate resulted in improved corrosion resistance for FBJ specimens, compared to joints produced with bare steel. An optical microscopy was used for cross-sectional analysis of corroded specimens. Some corrosion on the joining bit was observed near the bit head. However, the joining bit was still intact on the steel substrate, indicating that the primary bond was sound.

36 MATERIALS SCIENCE↗

Experimental Investigation and Finite Element Analysis on Fatigue Behavior of Aluminum Alloy 7050 Single-Lap Joints

The fatigue behavior of single-lap four-riveted aluminum alloy 7050 joints was investigated by using high-frequency fatigue test and scanning electron microscope (SEM). Stress distributions obtained by finite element (FE) analysis help explain the fatigue performance. The fatigue test results showed that the fatigue lives of the joints depend on cold expansion and applied cyclic loads. FE analysis and fractography indicated that the improved fatigue lives can be attributed to the reduction in maximum stress and evolution of fatigue damage at the critical location. The beneficial effects of strengthening techniques result in tearing ridges or lamellar structure on fracture surface, decrease in fatigue striations spacing, delay of fatigue crack initiation, crack deflection in fatigue crack propagation and plasticity-induced crack closure.

36 MATERIALS SCIENCE↗

Optimization of pin bearing joint strength for segmented graphite/epoxy filament wound case in Space Shuttle

An attempt is made to demonstrate the feasibility of a composite joint in a segmented, graphite/epoxy filament-wound composite case for the Space Shuttle's Solid Rocket Motors. The joint's required ultimate line load is of the of 82,000 lb/in. By optimizing composite layup, and the ratios of pin diameter/specimen thickness, edge distance/pin diameter, and specimen width/pin diameter, a pin bearing joint strength of 85 ksi was obtained. Double pin testing disclosed that the pin close to the composite joint carries a higher load than the outboard pin. Pin bearing strength is noted to vary with matrix resin system.

Munjal, A. K.↗

Microstructure and mechanical properties of joints in sintered SiC fiber-bonded ceramics brazed with Ag Cu Ti alloy

Active metal brazing of a new high thermal conductivity sintered SiC-polycrystalline fiber-bonded ceramic (SA-Tyrannohexs) has been carried out using a Ti-containing Ag Cu active braze alloy (Cusil-ABAs). The brazed composite joints were characterized using scanning electron microscopy coupled with energy-dispersive X-ray spectrometry (SEM EDS). The results show that this material can be successfully joined using judiciously selected off-the shelf active braze alloys to yield metallurgically sound joints possessing high integrity. Uniform and continuous joints were obtained irrespective of differences in the fiber orientation in the substrate material. Detailed interfacial microanalysis showed that the titanium reacts with C and Si to form TiC layer and a Ti Si compound, respectively. Furthermore, the evaluation of shear strength of the joints was also conducted at ambient and elevated temperatures in air using the single-lap offset (SLO) shear test. The perpendicular-type SA-Tyrannohex joints exhibited apparent shear strengths of about 42 MPa and 25 MPa at 650 1C and 750 1C, respectively. The fracture at the higher temperature occurred at the interface between the reactionformed TiC layer and braze. This might be caused by generation of stress intensity when a shear stress was applied, according to m-FEA simulation results.

Singh, Mrityunjay↗