Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Holographic Airborne Rotating Lidar Instrument Experiment (HARLIE)

Scanning holographic lidar receivers are currently in use in two operational lidar systems, PHASERS (Prototype Holographic Atmospheric Scanner for Environmental Remote Sensing) and now HARLIE (Holographic Airborne Rotating Lidar Instrument Experiment). These systems are based on volume phase holograms made in dichromated gelatin (DCG) sandwiched between 2 layers of high quality float glass. They have demonstrated the practical application of this technology to compact scanning lidar systems at 532 and 1064 nm wavelengths, the ability to withstand moderately high laser power and energy loading, sufficient optical quality for most direct detection systems, overall efficiencies rivaling conventional receivers, and the stability to last several years under typical lidar system environments. Their size and weight are approximately half of similar performing scanning systems using reflective optics. The cost of holographic systems will eventually be lower than the reflective optical systems depending on their degree of commercialization. There are a number of applications that require or can greatly benefit from a scanning capability. Several of these are airborne systems, which either use focal plane scanning, as in the Laser Vegetation Imaging System or use primary aperture scanning, as in the Airborne Oceanographic Lidar or the Large Aperture Scanning Airborne Lidar. The latter class requires a large clear aperture opening or window in the aircraft. This type of system can greatly benefit from the use of scanning transmission holograms of the HARLIE type because the clear aperture required is only about 25% larger than the collecting aperture as opposed to 200-300% larger for scan angles of 45 degrees off nadir.

Schwemmer, Geary K.↗

In situ monitoring of microstructure evolution during thermal processing of uranium-zirconium alloys using laser-generated ultrasound

In this study, laser-generated ultrasound was used to monitor microstructure evolution during thermal processing of as-cast, polycrystalline binary uranium-zirconium metallic fuel alloys with compositions of U-20wt.%Zr (U-20Zr), U-50wt.%Zr (U-50Zr) and U-80wt.%Zr (U-80Zr). Ultrasonic waveforms were recorded during heating and cooling the samples from room temperature to >973 K and back. A phase transition temperature for all three compositions was estimated from the temperature at which an abrupt and rapid reduction in ultrasonic velocities was observed. Microstructural features on the length scale of tens of micrometers were inferred from the observation of scattering of ultrasonic waves by elastic heterogeneities above ~823 K in U-20Zr, while a hysteresis in the ultrasonic velocities of U-80Zr upon cooling was attributed to a partial retention of the high temperature phase following thermal annealing. The U-50Zr alloy exhibited a reversible viscoelastic response above 933 K, as evidenced by the observation of high frequency attenuation of the shear component of the waveforms at high temperature. Ultrasonic measurements were supplemented by in situ transmission electron microscopy (TEM). The TEM images revealed that the δ-U-Zr matrix in the three compositions underwent a spinodal decomposition above ~823 K into nanoscale regions. The ultrasonic measurements revealed larger, micron-scale structure evolution in the U-20Zr alloy at the same temperature. This large-scale structure is associated with heterogeneous regions having different Zr content. Our findings show the potential heating rate dependence of microstructural evolution in U-Zr alloys and highlight differences in the thermomechanical response and associated length scales during thermal annealing between single- and dual-phase compositions. These results demonstrate the utility of laser ultrasonics to rapidly and efficiently scan phase boundaries and monitor micrometer-scale structure evolution in metallic fuel alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A coherent light scanner for optical processing of large format transparencies

A laser scanner is discussed in which the scanning beam is random-access addressable and perpendicular to the image input plane and the irradiance of the scanned beam is controlled so that a constant average irradiance is maintained after passage through the image plane. The scanner's optical system and design are described, and its performance is evaluated. It is noted that with this scanner, data in the form of large-format transparencies can be processed without the expense, space, maintenance, and precautions attendant to the operation of a high-power laser with large-aperture collimating optics. It is shown that the scanned format as well as the diameter of the scanning beam may be increased by simple design modifications and that higher scan rates can be achieved at the expense of resolution by employing acousto-optic deflectors with different relay optics.

Callen, W. R.↗

A 4 U Laser Heterodyne Radiometer for Methane (CH4) and Carbon Dioxide (CO2) Measurements from an Occultation-Viewing CubeSat

We present a design for a 4 U (20 cm 20 cm 10 cm) occultation-viewing laser heterodyne radiometer (LHR) that measures methane (CH4), carbon dioxide (CO2) and water vapor(H2O) in the limb that is designed for deployment on a 6 U CubeSat. The LHR design collects sunlight that has undergone absorption by the trace gas and mixes it with a distributive feedback (DFB) laser centered at 1640 nm that scans across CO2, CH4, and H2O absorption features. Upper troposphere lower stratosphere measurements of these gases provide key inputs to stratospheric circulation models: measuring stratospheric circulation and its variability is essential for projecting how climate change will affect stratospheric ozone.

occultation↗

A technique for breaking ice in the path of a ship

A technique is described for breaking ice in the path of a ship. A laser is placed on the bow of the ship with apparatus to scan the ice in the path of the ship with the laser beam. The beam cuts or shatters the ice, enabling the ship to break the ice in its path.

Saunders, A. R.↗

Quantitative measurement of oxygen in microgravity combustion

This research combines two innovations in an experimental system which should result in a new capability for quantitative, nonintrusive measurement of major combustion species. Using a newly available vertical cavity surface-emitting diode laser (VCSEL) and an improved spatial scanning method, we plan to measure the temporal and spatial profiles of the concentrations and temperatures of molecular oxygen in a candle flame and in a solid fuel (cellulose sheet) system. The required sensitivity for detecting oxygen is achieved by the use of high frequency wavelength modulation spectroscopy (WMS). Measurements will be performed in the NASA Lewis 2.2-second Drop Tower Facility. The objective of this research is twofold. First, we want to develop a better understanding of the relative roles of diffusion and reaction of oxygen in microgravity combustion. As the primary oxidizer species, oxygen plays a major role in controlling the observed properties of flames, including flame front speed (in solid or liquid flames), extinguishment characteristics, flame size, and flame temperature. The second objective is to develop better diagnostics based on diode laser absorption which can be of real value in microgravity combustion research. We will also demonstrate diode lasers' potential usefulness for compact, intrinsically-safe monitoring sensors aboard spacecraft. Such sensors could be used to monitor any of the major cabin gases as well as important pollutants.

Silver, Joel A.↗

Nitric Oxide PLIF Measurements in the Hypersonic Materials Environmental Test System (HYMETS)

A nonintrusive laser-based measurement system has been applied for the first time in the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. Planar laser-induced fluorescence of naturally occurring nitric oxide (NO) has been used to obtain instantaneous flow visualization images, and to make both radial and axial velocity measurements. Results are presented at selected facility run conditions, including some in simulated Earth atmosphere (75% nitrogen, 20% oxygen, 5% argon) and others in simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon), for bulk enthalpies ranging from 6.5 MJ/kg to 18.4 MJ/kg. Flow visualization images reveal the presence of large scale unsteady flow structures, and indicate nitric oxide fluorescence signal over more than 70% of the core flow for bulk enthalpies below about 11 MJ/kg, but over less than 10% of the core flow for bulk enthalpies above about 16 MJ/kg. Axial velocimetry was performed using molecular tagging velocimetry (MTV). Axial velocities of about 3 km/s were measured along the centerline. Radial velocimetry was performed by scanning the wavelength of the narrowband laser and analyzing the resulting Doppler shift. Radial velocities of 0.5km/s were measured.

Inman, Jennifer A.↗

Nitric Oxide PLIF Measurements in the Hypersonic Materials Environmental Test System (HYMETS)

Planar laser-induced fluorescence (PLIF) of naturally occurring nitric oxide (NO) has been used to obtain instantaneous flow visualization images, and to make both radial and axial velocity measurements in the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. This represents the first application of NO PLIF flow visualization in HYMETS. Results are presented at selected facility run conditions, including some in a simulated Earth atmosphere (75% nitrogen, 20% oxygen, 5% argon) and others in a simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon), for specific bulk enthalpies ranging from 6.5 MJ/kg to 18.4 MJ/kg. Flow visualization images reveal the presence of large scale unsteady flow structures, and indicate nitric oxide fluorescence signal over more than 70% of the core flow for specific bulk enthalpies below about 11 MJ/kg, but over less than 10% of the core flow for specific bulk enthalpies above about 16 MJ/kg. Axial velocimetry was performed using molecular tagging velocimetry (MTV). Axial velocities of about 3 km/s were measured along the centerline. Radial velocimetry was performed by scanning the wavelength of the narrowband laser and analyzing the resulting Doppler shift. Radial velocities of +/- 0.5 km/s were measured.

Inman, Jennifer A.↗

Determining processing behaviour of pure Cu in laser powder bed fusion using direct micro-calorimetry

We report copper is challenging to process by laser powder bed fusion (LPBF) given its high reflectivity at common infrared laser diode wavelengths and high thermal conductivity. Successful deposition of copper in a predictable and repeatable fashion relies on understanding the development of the keyhole melting regime, as well as heating, melting, boiling and vapour formation behaviour when interacting with a laser beam within an LPBF environment. In this study, in situ optical absorptivity measurements are used to clarify the complex physics of the laser material interaction. Absorptivity of laser energy is measured using direct micro-calorimetry and compared to melt pool depth in correlation to processing parameters. The measured absorptivity for a 100 μm layer thickness of powder was found to be approximately four times higher than that of the bare polished discs. It was also shown that high laser power above 500 W and scan speed up to 150 mm/s are appropriate for effective melting of the powder layer, with these parameters overcoming the threshold required to achieve keyhole melting. This is explained by multiple reflections withing the powder particles and the lower thermal conductivity of packed powder in comparison to bare discs. Melt pool formation was found to be highly unstable and an explosive behavior was observed when in the keyhole regime, caused by high fluctuations in absorptivity values. This work demonstrates calorimetry can be used to monitor melting behaviour in a real-time fashion during processing for this challenging to process material, thereby avoiding unnecessary parametric optimisation. In addition, the parametric window for optimum processing revealed here can inform future work.

36 MATERIALS SCIENCE↗

Vertically Aligned Single-Crystalline CoFe 2 O 4 Nanobrush Architectures with High Magnetization and Tailored Magnetic Anisotropy

Micrometer-tall vertically aligned single-crystalline CoFe 2 O 4 nanobrush architectures with extraordinarily large aspect ratio have been achieved by the precise control of a kinetic and thermodynamic non-equilibrium pulsed laser epitaxy process. Direct observations by scanning transmission electron microscopy reveal that the nanobrush crystal is mostly defect-free by nature, and epitaxially connected to the substrate through a continuous 2D interface layer. In contrast, periodic dislocations and lattice defects such as anti-phase boundaries and twin boundaries are frequently observed in the 2D interface layer, suggesting that interface misfit strain relaxation under a non-equilibrium growth condition plays a critical role in the self-assembly of such artificial architectures. Further, magnetic property measurements have found that the nanobrushes exhibit a saturation magnetization value of 6.16 μB/f.u., which is much higher than the bulk value. The discovery not only enables insights into an effective route for fabricating unconventional high-quality nanostructures, but also demonstrates a novel magnetic architecture with potential applications in nanomagnetic devices.

36 MATERIALS SCIENCE↗

Photodiode-based machine learning for optimization of laser powder bed fusion parameters in complex geometries

We report the quality of parts produced through laser powder bed fusion additive manufacturing can be irregular, with complex geometries sometimes exhibiting dimensional inaccuracies and defects. For optimal part quality, laser process parameters should be selected carefully prior to printing and adjusted during the print if necessary. This is challenging since approaches to control and optimize the build parameters need to take into account the part geometry, the material, and the complex physics of laser powder bed fusion. This work describes a data-driven approach using experimental diagnostics for the optimization of laser process parameters prior to printing. A training dataset is generated by collecting high speed photodiode signal data while printing simple parts containing key geometry features with various process parameter strategies. Supervised learning approaches are employed to train both a forward model and an inverse model. The forward model takes as inputs track-wise geometry features and laser parameters and outputs the photodiode signal along the scan path. The inverse model takes as inputs the geometry features and photodiode signal and predicts the laser parameters. Given the part geometry and a desired photodiode signal, the inverse model can thus determine the required laser parameters. Two test parts which contain defect-prone features are used to assess the validity of the inverse model. The use of the model leads to improved part quality (higher dimensional accuracy, reduced dross, reduced distortion) for both test geometries.

36 MATERIALS SCIENCE↗

Effective utilization of quantum-cascade distributed-feedback lasers in absorption spectroscopy

A variable duty cycle quasi-cw frequency scanning technique was applied to reduce thermal effects resulting from the high heat dissipation of type I quantum-cascade lasers. This technique was combined with a 100-m path-length multipass cell and a zero-air background-subtraction technique to enhance detection sensitivity to a parts-in-10(9) (ppb) concentration level for spectroscopic trace-gas detection of CH4, N2O, H2O, and C2H5OH in ambient air at 7.9 micrometers. A new technique for analysis of dense high resolution absorption spectra was applied to detection of ethanol in ambient air, yielding a 125-ppb detection limit.

NASA Discipline Environmental Health↗

High-Speed Laser Scanner Maps a Surface in Three Dimensions

A scanning optoelectronic instrument generates the digital equivalent of a threedimensional (X,Y,Z) map of a surface that spans an area with resolution on the order of 0.005 in. ( 0.125mm). Originally intended for characterizing surface flaws (e.g., pits) on space-shuttle thermal-insulation tiles, the instrument could just as well be used for similar purposes in other settings in which there are requirements to inspect the surfaces of many objects. While many commercial instruments can perform this surface-inspection function, the present instrument offers a unique combination of capabilities not available in commercial instruments. This instrument utilizes a laser triangulation method that has been described previously in NASA Tech Briefs in connection with simpler related instruments used for different purposes. The instrument includes a sensor head comprising a monochrome electronic camera and two lasers. The camera is a high-resolution

Lavelle, Joseph↗

Folding at the Microscale: Enabling Multifunctional 3D Origami‐Architected Metamaterials

Abstract Mechanical metamaterials inspired by the Japanese art of paper folding have gained considerable attention because of their potential to yield deployable and highly tunable assemblies. The inherent foldability of origami structures enlarges the material design space with remarkable properties such as auxeticity and high deformation recoverability and deployability, the latter being key in applications where spatial constraints are pivotal. This work integrates the results of the design, 3D direct laser writing fabrication, and in situ scanning electron microscopic mechanical characterization of microscale origami metamaterials, based on the multimodal assembly of Miura‐Ori tubes. The origami‐architected metamaterials, achieved by means of microfabrication, display remarkable mechanical properties: stiffness and Poisson’s ratio tunable anisotropy, large degree of shape recoverability, multistability, and even reversible auxeticity whereby the metamaterial switches Poisson’s ratio sign during deformation. The findings here reported underscore the scalable and multifunctional nature of origami designs, and pave the way toward harnessing the power of origami engineering at small scales.

Lin, Zhaowen↗

Characterization of Virgin, Re-used, and Oxygen-reduced Copper Powders processed by the Plasma Spheroidization Process

We report that fabrication of parts with high mechanical properties heavily depend on the quality of powder deployed in the fabrication process. Copper powder in three different powder types were spheroidized using radio-frequency inductively coupled plasma (ICP) spheroidization process (TekSphero-15 system). The characterized powders include virgin powder as purchased from the powder manufacturer, powder used in electron beam powder bed fusion (EB-PBF) process, and reconditioned powder, which was used powder that underwent an oxygen-reduction treatment. The goal of spheroidizing these powder types was to evaluate the change in powder morphology, the possibility of enhancing the powder properties back to their as-received conditions, and assess oxygen reduction of the powder lots given their initial oxygen contents. Also, to investigate the impact of re-spheroidization on powder properties, the second round of spheroidization was performed on the already used-spheroidized powder. The impact of powder type on powder sphericity and particle size distribution was evaluated using the image analysis of scanning electron microscope (SEM) micrographs and laser diffraction, respectively. The spheroidized powder showed higher sphericity and more uniform particle size distribution overall. Depending on the powder collection bin, second round of spheroidization affected the powder sphericity differently. The possibility of deploying the plasma spheroidization process as an alternative oxygen-reduction technique was also investigated through tracking the powders’ oxygen content using inert gas fusion method before and after the spheroidization. The plasma spheroidized powder showed less oxygen content than the hydrogen-treated powder. The second round of spheroidization caused no change in oxygen content. The correlation between oxygen-reduction and created cracks was discussed and compared between plasma spheroidization and hydrogen-treatment. The plasma spheroidization process created a powder with higher sphericity, uniform particle size, and less oxygen content.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing the ultrafast gain and refractive index dynamics of a VECSEL

Typically, strong gain saturation and gain dynamics play a crucial role in semiconductor laser mode-locking. While there have been several investigations of the ultrafast gain dynamics in vertical-external-cavity surface-emitting lasers (VECSELs), little is known about the associated refractive index changes. Yet, such refractive index changes do not only have a profound impact on the pulse formation process leading to self-phase modulation, which needs to be compensated by dispersion, but they are also of particular relevance for assessing the feasibility of Kerr-lens mode-locking of VECSELs. Here, we measure both refractive index as well as gain dynamics of a VECSEL chip using the ultrafast beam deflection method. We find that, in contrast to the gain dynamics, the refractive index dynamics is dominated by an instantaneous (100 fs) and a very slow component (100 ps). The time-resolved measurement of nonlinear refraction allows us to predict a pulse-length dependent, effective nonlinear refractive index n 2,eff , which is shown to be negative and on the order of 10 -16 m 2 =W for short pulse lengths (100 fs). It becomes positive for large excitation fluences and large pulse lengths (few ps). These results agree with some previous reports of self-mode-locked VECSELs for which the cavity design and pulse properties determine sign and strength of the nonlinear refractive index when assuming Kerr-lens mode-locking.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗