Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Ion beams 12, Legnaro 6-8 June 2012, the 50 years (1961-2011) of the Legnaro Laboratory

A short review of the history of the Legnaro Laboratory is presented since its foundation 50 years ago by Prof. A. Rostagni of the University of Padova. The evolution of the Laboratory as a national reference center for fundamental and applied nuclear physics researches is outlined, pointing out its transformation into the INFN National Laboratories in 1968. After the first CN VdG Accelerator of 5.5 MV operating in 1961 and the AN2000 devoted to interdisciplinary researches (1971), i.e. 40 years ago, ten years later the advent of the first heavy ion facility in Italy, the XTU Tandem accelerator, and later on of the ALPI superconducting linear accelerator, was crucial for any future developments, not only in the field of nuclear physics but also for the evolution of interdisciplinary programmes with ion beams.

43 PARTICLE ACCELERATORS↗

Simulations of Bunch Precompression at High Currents in the SLC Damping Rings

In the Stanford Linear Collider (SLC) each beam, after leaving a damping ring, is compressed in the Ring-to-Linac (RTL) transfer line before entering the linear accelerator. At a bunch population of 4.0 x 10{sup 10} particles, due to the limited energy acceptance of the RTL, approximately 15% of the beam has normally been lost. During the 1996 run, however, to eliminate this loss the bunch was partially precompressed in the damping ring, just before extraction; the beam loss in the RTL was reduced to almost zero. The operation and performance of precompression are presented by Minty et al. (1999). Also given is an analysis which, however, does not include the effects of the longitudinal wakefield on the beam dynamics. In this report we extend that analysis to include these effects.

43 PARTICLE ACCELERATORS↗

Tilt and Translation Motion Perception during Off Vertical Axis Rotation

The effect of stimulus frequency on tilt and translation motion perception was studied during constant velocity off-vertical axis rotation (OVAR), and compared to the effect of stimulus frequency on eye movements. Fourteen healthy subjects were rotated in darkness about their longitudinal axis 10deg and 20deg off-vertical at 0.125 Hz, and 20deg offvertical at 0.5 Hz. Oculomotor responses were recorded using videography, and perceived motion was evaluated using verbal reports and a joystick with four degrees of freedom (pitch and roll tilt, mediallateral and anteriorposterior translation). During the lower frequency OVAR, subjects reported the perception of progressing along the edge of a cone. During higher frequency OVAR, subjects reported the perception of progressing along the edge of an upright cylinder. The modulation of both tilt recorded from the joystick and ocular torsion significantly increased as the tilt angle increased from 10deg to 20deg at 0.125 Hz, and then decreased at 0.5 Hz. Both tilt perception and torsion slightly lagged head orientation at 0.125 Hz. The phase lag of torsion increased at 0.5 Hz, while the phase of tilt perception did not change as a function of frequency. The amplitude of both translation perception recorded from the joystick and horizontal eye movements was negligible at 0.125 Hz and increased as a function of stimulus frequency. While the phase lead of horizontal eye movements decreased at 0.5 Hz, the phase of translation perception did not vary with stimulus frequency and was similar to the phase of tilt perception during all conditions. During dynamic linear acceleration in the absence of other sensory input (canal, vision) a change in stimulus frequency alone elicits similar changes in the amplitude of both self motion perception and eye movements. However, in contrast to the eye movements, the phase of both perceived tilt and translation motion is not altered by stimulus frequency. We conclude that the neural processing to distinguish tilt and translation linear acceleration stimuli differs between eye movements and motion perception.

Wood, Scott J.↗

Medical Application of the SARAF-Proton/Deuteron 40 MeV Superconducting Linac

The Soreq Applied Research Accelerator Facility (SARAF) is based on a superconducting linear accelerator currently being built at the Soreq research center (Israel). The SARAF is planned to generate a 2 mA 4 MeV proton beam during its first year of operation and up to 40 MeV proton or deuteron beam in 2012. The high intensity beam, together with the linac ability to adjust the ion energy provides opportunities for medical research, such as Boron Neutron Capture Therapy (BNCT) and the production of medical radioisotopes, for instance {sup 103}Pd for prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oculomotor control of primary eye position discriminates between translation and tilt

We have previously shown that fast phase axis orientation and primary eye position in rhesus monkeys are dynamically controlled by otolith signals during head rotations that involve a reorientation of the head relative to gravity. Because of the inherent ambiguity associated with primary otolith afferent coding of linear accelerations during head translation and tilts, a similar organization might also underlie the vestibulo-ocular reflex (VOR) during translation. The ability of the oculomotor system to correctly distinguish translational accelerations from gravity in the dynamic control of primary eye position has been investigated here by comparing the eye movements elicited by sinusoidal lateral and fore-aft oscillations (0.5 Hz +/- 40 cm, equivalent to +/- 0.4 g) with those during yaw rotations (180 degrees/s) about a vertically tilted axis (23.6 degrees). We found a significant modulation of primary eye position as a function of linear acceleration (gravity) during rotation but not during lateral and fore-aft translation. This modulation was enhanced during the initial phase of rotation when there was concomitant semicircular canal input. These findings suggest that control of primary eye position and fast phase axis orientation in the VOR are based on central vestibular mechanisms that discriminate between gravity and translational head acceleration.

NASA Discipline Neuroscience↗

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of a flat substrate is changed by placing torques (couples) at each end. Depending on the applied couples, one can tune the shape close to a desired tangential cylinder, ellipse or parabola. We review the nature of the bending, requirements and approaches to the mechanical design, describe original optical and at-wavelength techniques for optimal tuning of bendable optics and alignment on the beamline, and provide beamline performance of the bendable optics used for sub-micro and nano focusing of soft x-rays.

42 ENGINEERING↗

Treatment Planning System Calculation Errors Are Present in Most Imaging and Radiation Oncology Core-Houston Phantom Failures

Purpose: The anthropomorphic phantom program at the Houston branch of the Imaging and Radiation Oncology Core (IROC-Houston) is an end-to-end test that can be used to determine whether an institution can accurately model, calculate, and deliver an intensity modulated radiation therapy dose distribution. Currently, institutions that do not meet IROC-Houston's criteria have no specific information with which to identify and correct problems. In the present study, an independent recalculation system was developed to identify treatment planning system (TPS) calculation errors. Methods and Materials: A recalculation system was commissioned and customized using IROC-Houston measurement reference dosimetry data for common linear accelerator classes. Using this system, 259 head and neck phantom irradiations were recalculated. Both the recalculation and the institution's TPS calculation were compared with the delivered dose that was measured. In cases in which the recalculation was statistically more accurate by 2% on average or 3% at a single measurement location than was the institution's TPS, the irradiation was flagged as having a “considerable” institutional calculation error. The error rates were also examined according to the linear accelerator vendor and delivery technique. Results: Surprisingly, on average, the reference recalculation system had better accuracy than the institution's TPS. Considerable TPS errors were found in 17% (n=45) of the head and neck irradiations. Also, 68% (n=13) of the irradiations that failed to meet the IROC-Houston criteria were found to have calculation errors. Conclusions: Nearly 1 in 5 institutions were found to have TPS errors in their intensity modulated radiation therapy calculations, highlighting the need for careful beam modeling and calculation in the TPS. An independent recalculation system can help identify the presence of TPS errors and pass on the knowledge to the institution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design of the injection beamline for the Californium Rare Isotope Breeder Upgrade electron beam ion source charge breeder

The design of the ion injection line connecting the electron beam ion source (EBIS) charge breeder and the Californium Rare Isotope Breeder Upgrade radio frequency quadrupole cooler-buncher at the Argonne Tandem Linear Accelerator System was investigated with particle tracking simulations. The injection line was configured to accommodate several differential pumping sections, individual optical components were optimized to minimize emittance growth, and the ion beam parameters were matched with the EBIS electron beam acceptance to minimize losses upon injection.

43 PARTICLE ACCELERATORS↗

FLASH2: Operation, beamlines, and photon diagnostics

FLASH2, a major extension of the soft X-ray free-electron laser FLASH at DESY, turns FLASH into a multi-user FEL facility. A new undulator line is located in a separate accelerator tunnel and driven additionally by the FLASH linear accelerator. First lasing of FLASH2 was achieved in August 2014 with simultaneous user operation at FLASH1. The new FLASH2 experimental hall offers space for up to six experimental end stations, some of which will be installed permanently. The wide wavelength range spans from 4-60 nm and 0.8 nm in the 5{sup th} harmonic and in the future deep into the water window in the fundamental. While this is of high interest to users, it is challenging from the beamline instrumentation point of view. Online diagnostics - which are mostly pulse resolved - for beam intensity, position, wavelength, wave front, and pulse length have been to a large extent developed at FLASH(1) and have now been optimized for FLASH2. Pump-probe facilities for XUV-XUV, XUV optical and XUV-THz experiments will complete the FLASH2 user facility.

43 PARTICLE ACCELERATORS↗

Quasi-linear heating and acceleration in bi-Maxwellian plasmas

Quasi-linear acceleration and heating rates are derived for drifting bi-Maxwellian distribution functions in a general nonrelativistic case for arbitrary wave vectors, propagation angles, and growth/damping rates. The heating rates in a proton-electron plasma due to ion-cyclotron/kinetic Alfvén and mirror waves for a wide range of wavelengths, directions of propagation, and growth or damping rates are explicitly computed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative transduction mechanisms of hair cells in the bullfrog utriculus. 1: Responses to intracellular current

Hair cells in the bullfrog sacculus are specifically adapted to sense small-amplitude, high-frequency linear accelerations. These hair cells display many properties that are undesirable or inappropriate for hair cells that must provide static gravity sensitivity. This study resulted in part due to an interest in seeing how the transduction mechanisms of hair cells in a gravity-sensing otolith endorgan would differ from those in the bullfrog sacculus. The bullfrog utriculus is an appropriate model for these studies, because its structure is representative of higher vertebrates in general and its function as a sensor of static gravity and dynamic linear acceleration is well known. Hair cells in the bullfrog utriculus, classifiable as Type 2 by cell body and synapse morphology, differ markedly in hair bundle morphology from those in the bullfrog sacculus. Moreover, the hair bundle morphologies of utricular hair cells, unlike those in the sacculus, differ in different membrane regions.

Baird, Richard A.↗

Properties of cerebellar fastigial neurons during translation, rotation, and eye movements

The most medial of the deep cerebellar nuclei, the fastigial nucleus (FN), receives sensory vestibular information and direct inhibition from the cerebellar vermis. We investigated the signal processing in the primate FN by recording single-unit activities during translational motion, rotational motion, and eye movements. Firing rate modulation during horizontal plane translation in the absence of eye movements was observed in all non-eye-movement-sensitive cells and 26% of the pursuit eye-movement-sensitive neurons in the caudal FN. Many non-eye-movement-sensitive cells recorded in the rostral FN of three fascicularis monkeys exhibited convergence of signals from both the otolith organs and the semicircular canals. At low frequencies of translation, the majority of these rostral FN cells changed their firing rates in phase with head velocity rather than linear acceleration. As frequency increased, FN vestibular neurons exhibited a wide range of response dynamics with most cells being characterized by increasing phase leads as a function of frequency. Unlike cells in the vestibular nuclei, none of the rostral FN cells responded to rotational motion alone, without simultaneously exhibiting sensitivity to translational motion. Modulation during earth-horizontal axis rotation was observed in more than half (77%) of the neurons, although with smaller gains than during translation. In contrast, only 47% of the cells changed their firing rates during earth-vertical axis rotations in the absence of a dynamic linear acceleration stimulus. These response properties suggest that the rostral FN represents a main processing center of otolith-driven information for inertial motion detection and spatial orientation.

Non-NASA Center↗

Radiation hardness characterization of LKH-5 scintillating glass

Radiation hardness is an important property to examine in scintillators to help determine their expected lifetime in application cases where significant radiation dose is expected. Industrial imaging systems using 9 MV linear accelerators for x-ray radiography are one such application where significant radiation doses are expected to the scintillators used. Cadmium tungstate scintillators (CWO) and Thallium doped Cesium Iodide scintillators (CsI(Tl)) are used in some high energy cargo x-ray radiography systems. However, CWO has a high manufacturing cost for adequately uniform crystals and CsI(Tl) does not have sufficient radiation hardness. LKH-5 glass is being investigated as a potential low cost replacement for CWO and CsI(Tl). In this experiment 36 samples of a terbium doped silicate glass called LKH-5 were irradiated at doses up to 5 MRad using a 9 MV linear accelerator, and the change in their transmission properties was observed. Additionally, the glass was discovered to be a radiation hard glass due to the relatively small change in the transmission of the glass: less than 3% per cm at its emission peak of 550 nm and 5 MRad. This is similar to CWO which has a reported reduction in transmitted light of 2% per cm at 5 MRad and the emission peak of 475 nm and better than CsI(Tl) which is reported to have a reduction in transmitted light of 5% per cm at the emission peak of 550 nm and 4.2 MRad dose. Furthermore, an annealing procedure is described that returned the transmission of the glass to pre-irradiation values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Vestibulo-spinal reflex mechanisms

The specific objectives of experiments designed to investigate postural reflex behavior during sustained weightlessness are discussed. The first is to investigate, during prolonged weightlessness with Hoffmann response (H-reflex) measurement procedures, vestibulo-spinal reflexes associated with vestibular (otolith) responses evoked during an applied linear acceleration. This objective includes not only an evaluation of otolith-induced changes in a major postural muscle but also an investigation with this technique of the adaptive process of the vestibular system and spinal reflex mechanisms to this unique environment. The second objective is to relate space motion sickness to the results of this investigation. Finally, a return to the vestibulo-spinal and postural reflexes to normal values following the flight will be examined. The flight experiment involves activation of nerve tissue (tibial N) with electrical shock and the recording of resulting muscle activity (soleus) with surface electrodes. Soleus/spinal H-reflex testing procedures will be used in conjuction with linear acceleration through the subject's X-axis.

Reschke, M. F.↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Photonuclear Physics in SCALE

Radiation shielding modeling involves a wide range of applications, such as power reactors, critical experiments, portable sources, linear accelerators, and fusion systems. Particle energy ranges vary from thermal energies to fast energy spectra. MAVRIC, as the radiation shielding sequence of the SCALE code system [1] developed and maintained by Oak Ridge National Laboratory, is capable of modeling both neutron and photon interactions in matter and is widely used by the US Nuclear Regulatory Commission, Department of Energy, the National Nuclear Security Administration, and radiation shielding practitioners all around the world. Although most applications don’t involve highly energetic photons that can cause photonuclear reactions and create coupled chains of high energy, ionized electrons and bremsstrahlung radiation within a material medium, when present, these reactions can have a significant impact upon the downstream particle fluxes from incident photons above 20 MeV. For example, linear accelerators used for medical isotope production are examples of applications in which high-energetic photons are generated and used for driving or controlling other components of a complex facility. Radiation shielding analyses of such a facility would require accounting for any and all significant sources of radiation. Unfortunately, MAVRIC included no data and methods to model either photonuclear reactions or the bremsstrahlung photons until this work, which enabled accounting for both. Photonuclear reaction cross sections were imported from the Evaluated Nuclear Data File libraries, and corresponding methods were implemented in the SCALE code system; see Section 2 for how the nuclear data are imported and used. Bremsstrahlung photons were modeled by assuming thick-target approximation whereby all generated electrons and positrons due to photon interactions are assumed to be absorbed within the same material in which they were born, yielding a quick particle transport simulation method by using fast lookup tables for generating subsequent gammas; see Section 4 for details. A suite of verification models was used to test implemented methods and associated data. Tests yielded satisfactory results for the new features. Enhancements will be released as part of the next major SCALE release (v7.0), which is anticipated to be deployed in 2025, with beta releases available in the interim.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is a free electron laser facility in construction at Stanford Linear Accelerator Center. It is designed to operate in the wavelength range 0.15-1.5 nanometers. At the time of this conference, civil construction of new tunnels and buildings is complete, the necessary modifications to the SLAC linac are complete, and the undulator system and x-ray optics/diagnostics are being installed. The electron gun, 135 MeV injector linac and 250 MeV bunch compressor were commissioned in 2007. Accelerator commissioning activities are presently devoted to the achievement of performance goals for the completed 14 GeV linac.

43 PARTICLE ACCELERATORS↗

Collaborative Visualization for Large-Scale Accelerator Electromagnetic Modeling (Final Report)

This report contains the comprehensive summary of the work performed on the SBIR Phase II, Collaborative Visualization for Large-Scale Accelerator Electromagnetic Modeling at Kitware Inc. in collaboration with Stanford Linear Accelerator Center (SLAC). The goal of the work was to develop collaborative visualization tools for large-scale data as illustrated in the figure below. The solutions we proposed address the typical problems faced by geographicallyand organizationally-separated research and engineering teams, who produce large data (either through simulation or experimental measurement) and wish to work together to analyze and understand their data. Because the data is large, we expect that it cannot be easily transported to each team member's work site, and that the visualization server must reside near the data. Further, we also expect that each work site has heterogeneous resources: some with large computing clients, tiled (or large) displays and high bandwidth; others sites as simple as a team member on a laptop computer. Our solution is based on the open-source, widely used ParaView large-data visualization application. We extended this tool to support multiple collaborative clients who may locally visualize data, and then periodically rejoin and synchronize with the group to discuss their findings. Options for managing session control, adding annotation, and defining the visualization pipeline, among others, were incorporated. We also developed and deployed a Web visualization framework based on ParaView that enables the Web browser to act as a participating client in a collaborative session. The ParaView Web Visualization framework leverages various Web technologies including WebGL, JavaScript, Java and Flash to enable interactive 3D visualization over the web using ParaView as the visualization server. We steered the development of this technology by teaming with the SLAC National Accelerator Laboratory. SLAC has a computationally-intensive problem important to the nations scientific progress as described shortly. Further, SLAC researchers routinely generate massive amounts of data, and frequently collaborate with other researchers located around the world. Thus SLAC is an ideal teammate through which to develop, test and deploy this technology. The nature of the datasets generated by simulations performed at SLAC presented unique visualization challenges especially when dealing with higher-order elements that were addressed during this Phase II. During this Phase II, we have developed a strong platform for collaborative visualization based on ParaView. We have developed and deployed a ParaView Web Visualization framework that can be used for effective collaboration over the Web. Collaborating and visualizing over the Web presents the community with unique opportunities for sharing and accessing visualization and HPC resources that hitherto with either inaccessible or difficult to use. The technology we developed in here will alleviate both these issues as it becomes widely deployed and adopted.

43 PARTICLE ACCELERATORS↗