Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Field Evaluation of the High Efficiency Dehumidification System (HEDS) at the Timken Museum of Art - Measurement and Verification (M&V) Results from Summer, Winter and Spring Evaluation Periods

The High Efficiency Dehumidification System (HEDS) technology from Conservant Systems Inc., installed at the Timken Museum of Art in San Diego, California, was evaluated to determine its performance relative to appropriate baseline operation. Data was collected for measurement and verification for several weeks during three evaluation periods: Summer (Aug-Sep 2023), Winter (Dec 2023-Feb 2024) and Spring (May-Jun 2024). The evaluation included operating the heating, ventilation and air conditioning (HVAC) system in both constant air volume (CAV) and variable air volume (VAV) modes, with and without the HEDS energy recovery and HVAC system optimization technology enabled. The electricity consumption of the chiller and the gas-supplied reheat energy were measured to characterize savings achieved by the HEDS operation. Based on these measurements, the HEDS was responsible for chiller electrical load savings during the summer evaluation period of 39% and 42% for the CAV and VAV operating modes, respectively; 97% and 100% chiller electrical load reductions were observed during the winter evaluation for the CAV and VAV operating modes, respectively; and the corresponding reductions during the spring evaluation were 42% and 52% for CAV and VAV operation, respectively. The measured reheat energy reductions, which are typically provided by natural gas, due to the HEDS during summer were 64% and 97% in CAV and VAV operating modes, respectively, while the corresponding values were 99% and 78% during the winter evaluation, and 59% and 56% during the spring evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Analysis of Wind Turbine Wake Vortex Evolution Due to Time-Constant Spatial Variations in Atmospheric Flow

Modern utility-scale wind turbines are evolving toward larger, lighter, and more flexible designs to meet the growing demand for renewable energy while minimizing logistical costs. However, these advancements in lightweight design result in heightened aeroelastic sensitivity, leading to complex interactions which affect the rotor’s capacity to withstand aerodynamic loading and the cascading effects that manifest in the wake’s vortex-structure evolution under variable atmospheric conditions. In this paper, we analyze the influence of stream-wise fluctuating atmospheric flow conditions on wind turbines with large, flexible rotors through simulations of the National Rotor Testbed (NRT) turbine, located at Sandia National Labs’ Scaled Wind Farm Technology (SWiFT) facility in Lubbock, Texas. The Common Ordinary Differential Equation Framework (CODEF) modeling suite is used to simulate wind turbine aeroelastic oscillatory behavior and wind farm vortex–wake interactions for a range of conditions with spatially variant atmospheric flow. CODEF solutions for turbine operation in wind conditions featuring only one parameter fluctuation are compared to wind conditions with several wind parameter variations in combination. By isolating individual inflow variations and comparing them to multi-parameter scenarios, we determine the contributions of each atmospheric factor to rotor dynamics, wake evolution, and downstream wind farm interactions. The purpose of this paper is to analyze the effects of spatial variations in atmospheric flow on the topological evolution of wind turbine vortex wakes, which constitutes a gap in the current understanding of wind turbine wake dynamics. The insights gained from this study are particularly valuable for the development of wind farm control strategies aimed at mitigating the adverse effects of wake interactions, enhancing energy capture, and improving the overall stability of wind farm operations. With these insights, we aim to contribute to the development of modeling and simulation tools to optimize utility-scale wind power plants operating in diverse atmospheric environments.

Farrell, Alayna (ORCID:000000023555720X)↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Estimation of cutting tool wear using an elastomeric tactile sensor

Machining performance of cutting tools and part quality are affected by the geometric condition of the cutting edge, which is influenced by thermomechanical loads experienced during the process. Tool condition monitoring (TCM) systems provide insight for timely replacement of cutting tools. However, existing TCM systems are expensive and require specialized equipment or sensors, hindering widespread adoption. A novel TCM system is developed herein using an elastomeric tactile sensor. Sensor images of the cutting edge are used to quantify wear using two distinct algorithms. In the first algorithm, the unworn and worn edges are identified based on Canny edge detect. In the second, the unworn edge is identified using edge detection while the region of wear is identified using a relative intensity method. In both cases, the maximum wear width is calculated based on an experimentally determined pixel to-physical distance scale. The TCM system is first used to estimate flank wear on a solid carbide helical end mill before evaluating its robustness by employing it to estimate insert wear of an indexable helical end mill. Measurements are also performed manually using an optical microscope and a high-resolution focus variation microscope for verification. The novel technique estimates flank wear in the solid carbide tool with a high accuracy of 98%. Larger discrepancies are observed for the inserts, however, with overlapping uncertainties. In conclusion, the technique shows promise in adaptability, automation, and closed loop control of machine tools.

Machining↗

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗

Quantum limits of superconducting-photonic links and their extension to millimeter waves

Photonic addressing of superconducting circuits has been proposed to overcome wiring complexity and heat-load challenges. However, such superconducting-photonic links suffer from an efficiency-noise trade-off that limits scalability. This trade-off arises because increasing power conversion efficiency entails reducing optical power, which makes the converted signal susceptible to shot noise. We analyze this trade-off and find that the laser-driven qubit gate infidelity scales inversely with the number of photons used. While methods such as nonlinear detection or squeezed light could mitigate this effect, we consider generating higher-frequency electrical signals, such as millimeter waves (100 GHz), using laser light. At these higher frequencies, circuits have higher operating temperatures and cooling power budgets and alleviate constraints posed by the trade-off. Therefore, we demonstrate an optically driven cryogenic millimeter-wave source with a maximum power efficiency of 8 ×10 −5 that can generate a maximum of 0.7 μ⁢W of 80 GHz power, with a 1200-thermal-photon equivalent of added noise at 4K. Using this source, we perform frequency-domain spectroscopy of superconducting NbTiN resonators at 80–90 GHz. Our results show a promising approach to lessen the efficiency-noise constraints on superconducting-photonic links, while leveraging the benefits of photonic signal delivery. Further optimization of power efficiency and noise at high frequencies could make scalable photonic control of superconducting qubits viable at temperatures exceeding 1K.

Optoelectronics↗

Improving Efficiency of Off-Road Vehicles by Novel Integration of Electric Machines and Advanced Combustion Engines

Modern off-road equipment will increasingly rely on electrified implements that will deliver precision control with a smaller footprint than hydraulics. The primary energy converter, however, will be an onboard reciprocating internal combustion engine because of the power density of hydrocarbon fuels in comparison to electrical energy storage and the remote locations where much of this equipment is deployed. Adding energy storage and electric machines creates opportunities to improve efficiency while reducing emissions. This program investigated approaches to take advantage of the extra flexibility that an enhanced electrical system to enable high-efficiency, low-emissions combustion technologies. The current program evaluated hybridization of both the torque application and air-handling systems to maximize efficiency while minimizing cost. This program designed, analyzed and tested a hybrid off-road vehicle consisting of a series electric powertrain with energy storage, an electrified air system, and a 33% downsized diesel engine. Detailed comparisons were made between the base powertrain and the developed powertrain using powertrain simulations, engine testing, and vehicle testing. The key results of the study are: • The resulting vehicle reduces fuel consumption by 5% to 15% at equal productivity. The primary improvements were due to recovery of regenerative braking losses for cycles where large transients are encountered. • The electrified air system was an enabler to allow engine downsizing. This was most important for duty-cycles where the engine primarily operated at moderate loads and had few low speed high torque conditions. • Engine level improvements showed re-optimization of the powertrain is possible when electrified air handing is available. Increased exhaust gas recirculation and advanced injection timing allowed up to a 15% reduction in brake specific fuel consumption at equal NOx and transient response. Compared to the larger engine, the downsized engine achieves up to an 18% reduction in brake specific fuel consumption over the non-road transient cycle. • The life cycle analysis and total cost of ownership study showed that the hybrid powertrain has the potential to reduce 5-year CO2 and total cost of ownership by ~6% over the baseline vehicle. The results also indicated that a pure battery electric vehicle is not feasible in this application and is likely to increase the CO2 emissions due to the CO2 from battery production. A hybrid powertrain with low carbon fuels shows the potential to substantially reduce CO2 and total cost of ownership.

02 PETROLEUM↗

Integrated Hydrogen Energy System Testing/Validation: Cooperative Research and Development Final Report, CRADA Number CRD-21-18272

Through the ARIES platform, this proposed project aims to bridge a gap and utilize the power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments and create open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid forming fuel cell inverters.

08 HYDROGEN↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

End-Use Savings Shapes Measure Documentation: Window Film

This documentation focuses on a single end-use savings shape measure - window film. The window film studied in this analysis, called solar control film, is a passive retrofit solution for windows that does not involve window replacement. This type of film is composed of transparent, tinted, or metalized laminated polyester layers and can be attached to an existing window surface (either on the exterior or interior side of the window). The properties of the window film are designed to shift the thermal and optical performances of the overall glazing system in order to serve various needs the customer would have (e.g., heat, glare). While the practical goal of purchasing and installing a window film varies widely in the real market, this study only focuses on the goal of energy savings, and highlighting the corresponding emissions. Other important aspects that customers typically consider include visual comfort, privacy, aesthetics, ultraviolet protection, etc. Thus, in practice, customers often choose a window film product not only to save energy (or cost) but also to mitigate issues around glare, excessive light, daytime privacy, or inconsistent appearance of the building. Window film products that were modeled in this analysis significantly reduced the solar heat gain coefficient of the overall glazing system, resulting in better energy savings for buildings in hot climate regions. However, significantly reducing the solar heat gain coefficient that can block unfavorable heat during the summer can actually harm blocking favorable heat during the winter. By applying window films on a stock of buildings covering various load and weather conditions, this analysis highlights when (e.g., time of day) and where (e.g., geospacial location) we can save energy with window films.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ducted Fuel Injection And Cooled Spray Technologies For Particulate Control In Heavy-duty Diesel Engines (Final Report)

Cooled Spray (CS) and Ducted Fuel Injection (DFI) are in-cylinder technologies for diesel engines that can reduce particulate matter and soot emissions and data has been published showing that these technologies can reduce soot emissions by 75-100% for some engines at some operating conditions. However, little is known about scaling the devices for engine size. Additionally, the performance of either technology over the engine duty cycle has not been explored. This project addresses both of these points through single-cylinder engine investigations. The objectives of this project are to provide details about dimensional scaling of these devices and to demonstrate 75% PM reduction over a range of operating conditions on a single-cylinder engine. Two engines were used for this project: a 125mm bore optically accessible engine at Sandia National Laboratories and a 168mm bore metal engine at Southwest Research Institute. The optical engine was used to study the performance of DFI and CS inserts for a large injector orifice diameter injector that is characteristic of a locomotive engine and to perform scaling studies for DFI. The metal engine was used to perform scaling and alignment studies for CS and to evaluate the technology for both EGR and non-EGR engines over the engine operating map. Modifications were required for both engines to accept the prototype inserts being tested. The optical engine required a new fuel injector, cylinder head and piston so that tests could be run at the pressures and engine speeds required. Additionally, a novel rotating stage was designed for the optical engine to simplify alignment of the modules. The metal engine required a modified cylinder head to accept CS inserts and a modified piston to provide additional space around the fuel injector for the CS inserts. Tests on the optical engine showed that DFI reduces PM emissions for both small injector orifices (0.170mm diameter) and large injector orifices (0.290mm). For high load testing, the DFI modules were not as effective as at low load testing, but it was acknowledged that minimal geometric optimization was performed and more improvements may be possible. Comparing DFI to CS and conventional diesel combustion (CDC), DFI performed better than CS or CDC. The CS geometries used in these studies may not be ideal for that engine and additional modifications likely would improve performance. Tests on the metal engine showed PM reductions as high has 80% at some operating conditions with duty-cycle PM reductions of ~50% for EGR and non-EGR configurations. The CS testing on the metal engine showed that chamfering of the fuel passage inlet either through hydro-erosion or mechanical grinding provided significant improvements in the PM reduction capabilities of the insert. Additionally, alignment sensitivities were explored and the data show that the tolerance to misalignment is approximately 0.05 to 0.1mm for the inserts that were studied here. Air-fuel ratio was shown to be important in the effectiveness of the CS inserts. In several tests, it was shown that the CS inserts are more effective at reducing the PM for high-AFR operating conditions compared to low AFR conditions. In summary, multiple designs were evaluated on both engines. It was found that for the conditions and configurations studied here, a fuel passage diameter of ~2.5mm performed best overall. Significant duty-cycle PM reductions are possible using these technologies and sensitivities to AFR, alignment fuel passage diameter and inlet fuel passage shaping were explored and are reported here. More PM reduction may be possible with improved geometric design and attention to alignment practices.

02 PETROLEUM↗

Final Report on Predictive Analyses of PRD as Function of Anomalies

This report summarizes the work completed in FY-2024 to analyze the power reactivity decrement (PRD) concepts of the ARC-100 core. The PRD has been traditionally defined by the reactivity change from a hot zero power (HZP) to a particular power. Consequently, the PRD accounts for the core reactivity changes due to increase coolant temperature gradient axially and radially across the core, and increased fuel temperature. The coolant temperature gradient leads to sodium and structure density changes, to radial core expansion from assembly flowering and bowing (due to axial and radial temperature gradients within the assemblies), and to control rod driveline thermal expansion. The fuel temperature increase associated with coolant temperature and power increases leads to Doppler effect and axial thermal expansion. In this work, the normal operating Hot Full Power (HFP) state is the only power level of interest, so analyses focus on the PRD calculated from HZP to HFP. The PRD has been used to assess the reactor safety features asymptotically in unprotected accident scenarios, including the loss of heat sink (LOHS), loss of flow (LOF), and transient overpower (TOP) without scram. The PRD concept relies on the “global” reactivity coefficients A, B, and C that are estimated based on “individual” reactivity effects (Doppler, sodium density, etc.). The objectives of this work are: 1) to improve and verify the methodology used to calculate the ABC coefficients used in the PRD, 2) to assess if the PRD can be used to reliably identify abnormal events. This report fulfills the FY-2024 scope of WBS#1.15.8.3 activity, “ANL0120 – Predictive Analyses of PRD as function of deformation”. The PRD concept is described in Sections 2. Additional effort in refining the methodology for core bowing modeling is performed in Sections 3. Then, two verification exercises are proposed in Section 4 to benchmark these coefficients based on direct neutronic-only calculations and on dynamic core transient simulations. Finally, the PRD approach is assessed for the detection of several unexpected events, such as primary flow perturbation or improper fuel loading, in Section 5.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data collected using small uncrewed aircraft systems during the TRacking Aerosol Convection interactions ExpeRiment (TRACER)

Abstract. The main goal of the TRacking Aerosol Convection interactions ExpeRiment (TRACER) project was to further understand the role that regional circulations and aerosol loading play in the convective cloud life cycle across the greater Houston, Texas, area. To accomplish this goal, the United States Department of Energy and research partners collaborated to deploy atmospheric observing systems across the region. Cloud and precipitation radars, radiosondes, and air quality sensors captured atmospheric and cloud characteristics. A dense lower-atmospheric dataset was developed using ground-based remote sensors, a tethersonde, and uncrewed aerial systems (UASs). TRACER-UAS is a subproject that deployed two UAS platforms to gather high-resolution observations in the lower atmosphere between 1 June and 30 September 2022. The University of Oklahoma CopterSonde and the University of Colorado Boulder RAAVEN (Robust Autonomous Aerial Vehicle – Endurant Nimble) were flown at two coastal locations between the Gulf of Mexico and Houston. The University of Colorado Boulder RAAVEN gathered measurements of atmospheric thermodynamic state, winds and turbulence, and aerosol size distribution. Meanwhile, the University of Oklahoma CopterSonde system operated on a regular basis to resolve the vertical structure of the thermodynamic and kinematic state. Together, a complementary dataset of over 200 flight hours across 61 d was generated, and data from each platform proved to be in strong agreement. In this paper, the platforms and respective data collection and processing are described. The dataset described herein provides information on boundary layer evolution, the sea breeze circulation, conditions prior to and nearby deep convection, and the vertical structure and evolution of aerosols. The quality-controlled TRACER-UAS observations from the CopterSonde and RAAVEN can be found at https://doi.org/10.5439/1969004 (Lappin, 2023) and https://doi.org/10.5439/1985470 (de Boer, 2023), respectively.

54 ENVIRONMENTAL SCIENCES↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Geographically Distributed Co-Simulation for the Interplay of Integrated Energy Systems and Power Grid

The increased penetration of renewable generation induces unbalanced demand-supply on a power grid, while integrated energy systems (IES) can provide high part-load efficiency and high flexibility to support grid resilience. To study the transients and improve dynamic operability, it’s important to investigate the interplay between IES and power grid concurrently using real-time co-simulation approaches. In this presentation, we showed the previous co-simulation test between NETL and INL and discussed how this co-simulation can be beneficial for both IES and power grid research. In addition, we gave an overview about the SuperLab2.0 project, which was a federated national platform to address future power grid challenges. (Virtual presentation to the MILLENNIUM CLEAN and SUSTAINABLE POWER workshop 2025).

Co-simulation↗