At least 775 records · Page 43

Active control of vaneless diffuser rotating stall

Experiments were carried out to study the feasibility of active stabilization of vaneless diffuser rotating stalls. Pressure fluctuation at the diffuser inlet was monitored and used to control the rotating stall. AC control flow, which is produced by a load speaker, was introduced into the diffuser at the inlet. It is shown that the rotating stall can be suppressed when the phase of the control flow has a certain relation with the phase of the rotating stall. By considering the energy flux due to the AC control flow, it is shown that the rotating stall is suppressed when the control flow has the phase such that the energy is subtracted out from the diffuser flow. Discussions are made on the relations between the energy flux and the amplitude of the pressure fluctuation due to the rotating stalls.

Yoshida, Yoshiki↗

Analysis and Design of Crew Sleep Station for ISS

This paper details the analysis and design of the Temporary Sleep Station (TeSS) environmental control system for International Space Station (ISS). The TeSS will provide crewmembers with a private and personal space, to accommodate sleeping, donning and doffing of clothing, personal communication and performance of recreational activities. The need for privacy to accommodate these activities requires adequate ventilation inside the TeSS. This study considers whether temperature, carbon dioxide, and humidity within the TeSS remain within crew comfort and safety levels for various expected operating scenarios. Evaluation of these scenarios required the use and integration of various simulation codes. An approach was adapted for this study, whereby results from a particular code were integrated with other codes when necessary. Computational Fluid Dynamics (CFD) methods were used to evaluate the flow field inside the TeSS, from which local gradients for temperature, velocity, and species concentration such as CO (sub 2) could be determined. A model of the TeSS, containing a human, as well as equipment such as a laptop computer, was developed in FLUENT, a finite-volume code. Other factors, such as detailed analysis of the heat transfer through the structure, radiation, and air circulation from the TeSS to the US Laboratory Aisle, where the TeSS is housed, were considered in the model. A complementary model was developed in G189A, a code which has been used by NASA/JSC for environmental control systems analyses since the Apollo program. Boundary conditions were exchanged between the FLUENT and G189A TeSS models. G189A provides human respiration rates to the FLUENT model, while the FLUENT model provides local convective heat transfer coefficients to G189A model. An additional benefit from using an approach with both a systems simulation and CFD model, is the capability to verify the results of each model by comparison to the results of the other model. The G189A and FLUENT models were used to evaluate various ventilation designs for the TeSS over a range of operating conditions with varying crew metabolic load, equipment operating modes, ventilation flow rates, and with the TeSS doors open and closed. Results from the study were instrumental in the optimization of a design for the TeSS ventilation hardware. A special case was considered where failure of the TeSS ventilation system occurred. In this case, a study was conducted in order to determine the time required for the CO (sub 2) concentration inside the TeSS to increase to ISS limit values under transient conditions. A lumped-capacitance code, SINDA-FLUINT was used in this case to provide accurate predictions of the human reaction to the TeSS cabin conditions including core and skin temperatures and body heat storage. A simple two-dimensional CFD model of a crewmember inside the TeSS was developed in FLUENT in order to determine the volume envelope of the respired air from the human, which maintained a minimum velocity profile. This volume was then used in the SINDA-FLUINT model to facilitate the calculations of CO (sub 2) concentrations, dry bulb temperatures and humidity levels inside the TeSS.

Keener, John F.↗

Unsteady loads due to propulsive lift configurations

The flow of a jet over an airfoil representative of upper surface blowing was studied using laser techniques. Experimental techniques were developed for the investigation of unsteady pressures behind a cold model jet. Construction of a 1/4 scale model of the 'Beach' test configuration was completed along with construction of a portable detector. The portable detector is used in conjunction with a laser to measure jet flows during tests on the 'Beach' facility. The detector incorporates both optical and electronic components.

Morton, J. B.↗

Subsonic steady and unsteady aerodynamic loads on missiles and aircraft

Steady lifting flows over highly swept delta wings at large incidence were studied. After an exhaustive literature review, development of a vortex-lattice method was attempted. To demonstrate the feasibility of using such a method, an existing code was modified. A system of vortex lines to simulate the leading-edge wake was added. The coefficients predicted by the modified code were in good agreement with experimental data.

Source record↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration: Preprint

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Theoretical and Experimental Investigation of Random Gust Loads Part I : Aerodynamic Transfer Function of a Simple Wing Configuration in Incompressible Flow

Sinusoidally oscillating downwash and lift produced on a simple rigid airfoil were measured and compared with calculated values. Statistically stationary random downwash and the corresponding lift on a simple rigid airfoil were also measured and the transfer functions between their power spectra determined. The random experimental values are compared with theoretically approximated values. Limitations of the experimental technique and the need for more extensive experimental data are discussed.

RESEARCH TECHNIQUE, AERODYNAMIC↗

Stress-Induced Anomalous Transport in Natural Fracture Networks

In this work we investigate the effects of geological stress on fluid flow and tracer transport in natural fracture networks. We show the emergence of non-Fickian (anomalous) transport from the interplay among fracture network geometry, aperture heterogeneity, and geological stress. In this study, we extract the fracture network geometry from the geological map of an actual rock outcrop, and we simulate the geomechanical behavior of fractured rock using a hybrid finite-discrete element method. We analyze the impact of stress on the aperture distribution, fluid flow field, and tracer transport properties. Both stress magnitude and orientation have strong effects on the fracture aperture field, which in turn affects fluid flow and tracer transport through the system. We observe that stress anisotropy may cause significant shear dilation along long, curved fractures that are preferentially oriented to the stress loading. This, in turn, induces preferential flow paths and anomalous early arrival of tracers. An increase in stress magnitude enhances aperture heterogeneity by introducing more small apertures, which exacerbates late-time tailing. This effect is stronger when there is higher heterogeneity in the initial aperture field. To honor the flow field with strong preferential flow paths, we extend the Bernoulli Continuous Time Random Walk model to incorporate dual velocity correlation length scales. The proposed upscaled transport model captures anomalous transport through stressed fracture networks and agrees quantitatively with the high-fidelity numerical simulations.

54 ENVIRONMENTAL SCIENCES↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zoned results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space environment Simulator (SES). The flight external radiators are not available during ISIM-level thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided by specially designed test hardware which also measures the heat flow within each of the five heat straps to an accuracy of less than 2 mW, which is less than 5% of the minimum predicted heat flow values. Measurement of the heat loads to this accuracy is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. It also provides direct verification by test of several high-level thermal requirements. Devices that measure heat flow in this manner have historically been referred to a "Q-meters". Perhaps the most important feature of the design of the JWST Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on knowledge of precise heater power required to maintain a constant temperature difference between sensors on two stages, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper provides a brief review of Q-meter design, and discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

Theoretical prediction of interference loading on aircraft stores. Part 2: Supersonic speeds

A method is developed for theoretically predicting the loading on pylon-mounted stores in supersonic flow. Linear theory is used, without two dimensional or slender body assumptions, to predict the flow field produced by the aircraft wing, nose, inlet, and pylons. Aircraft shock wave locations are predicted, and their effect on the flow field is included through a transformation of the aircraft geometry. The interference loading is integrated over the store length by considering the local crossflow, its axial and radial derivatives, and buoyancy. Store moment calculations under an F-4 aircraft at Mach 1.2 are compared to wind tunnel data. The method is computerized, and program user information is included.

Danfernandes, F.↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

A Wave Energy Converter Design Load Case Study

This article presents an example by which design loads for a wave energy converter (WEC) might be estimated through the various stages of the WEC design process. Unlike previous studies, this study considers structural loads, for which, an accurate assessment is crucial to the optimization and survival of a WEC. Three levels of computational fidelity are considered. The first set of design load approximations are made using a potential flow frequency-domain boundary-element method with generalized body modes. The second set of design load approximations are made using a modified version of the linear-based time-domain code WEC-Sim. The final set of design load simulations are realized using computational fluid dynamics coupled with finite element analysis to evaluate the WEC’s loads in response to both regular and focused waves. This study demonstrates an efficient framework for evaluating loads through each of the design stages. In comparison with experimental and high-fidelity simulation results, the linear-based methods can roughly approximate the design loads and the sea states at which they occur. The high-fidelity simulations for regular wave responses correspond well with experimental data and appear to provide reliable design load data. The high-fidelity simulations of focused waves, however, result in highly nonlinear interactions that are not predicted by the linear-based most-likely extreme response design load method.

16 TIDAL AND WAVE POWER↗

Towing Tank and Flume Testing of Passively Adaptive Composite Tidal Turbine Blades: Preprint

Composite tidal turbine blades with bend-twist (BT) coupled layups allow the blade to self-adapt to local site conditions by passively twisting. Passive feathering has the potential to increase annual energy production and shed thrust loads and power under extreme tidal flows. Decreased hydrodynamic thrust and power during extreme conditions meann that the turbine support structure, generator, and other components can be sized more appropriately, resulting in a higher utilization factor and increased cost effectiveness. This paper presents new experimental data for a small-scale turbine with BT composite blades. The research team tested the turbine in the Kelvin Hydrodynamics Laboratory towing tank at the University of Strathclyde in Glasgow, United Kingdom, and in the recirculating current flume at the l Institut Francais de Recherche pour l Exploitation de la Mer Centre in Boulogne-sur-Mer, France. Tests were also performed on rigid aluminum blades with identical geometry, which yielded baseline test sets for comparison. The results from both facilities agreed closely, supporting the hypothesis that increased blade flexibility can induce load reductions. Under the most extreme conditions tested the turbine with BT blades had up to 11 percent lower peak thrust loads and a 15 percent reduction in peak power compared to the turbine with rigid blades. The load reductions varied as a function of turbine rotational velocity and ambient flow velocity.

17 WIND ENERGY↗

Poly(3,4-ethylenedioxypyrrole) Modified Emitter Electrode for Substitution of Homogeneous Redox Buffer Agent Hydroquinone in Electrospray Ionization Mass Spectrometry

The electrolysis inherent to the operation of the electrospray ionization (ESI) source used with mass spectrometry (MS) is a well-known attendant effect of generating unipolar spray droplets and may affect the analysis of the analyte of interest. Undesirable electrolysis of an analyte may be prevented by limiting the emitter electrode current and/or the mass transport characteristics of the system. However, these ways to avoid analyte electrolysis may not be applcable in all ESI-MS experiments. For example, in the case of specific nanospray systems (e.g. the wire-in-a-capillary bulk-loaded or chip-based tip-loaded nanospray configurations), the solution flow rate is fixed in the 50-500 nL/min range and the electrode surface to volume ratio is large presenting a very effcient analyte to electrode mass transport configuration. In these situations, control over the interfacial potential of the working electrode via homogeneous or traditional heterogeneous (sacrificial metal) redox buffering is a possible way to prevent analyte electrolysis. However, byproducts of these redox buffering approaches can appear in the mass spectra and/or they can chemically alter the analyte. For example, the main reason for using hydroquinone as a homogeneous redox buffer, in addition to its relatively low oxidation potential, is that neither the original compound nor its oxidation product benzoquinone can be detected directly by ESI-MS. However, benzoquinone can alter analytes with thiol functional groups by reacting with those groups via a 1,4-Michael addition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control methods for mitigating flow oscillations in a supercritical CO 2 recompression closed Brayton cycle

A dynamic model of a 10 MWe supercritical CO 2 (sCO 2 ) recompression closed Brayton power generation cycle is used to investigate control methods for mitigating oscillations in flow conditions and power demand load, especially as the load ramp rate is increased and the load setpoint is more closely tracked. The focus is on control of the main compressor inlet temperature (MCIT) since oscillations are prompted by the strong nonlinearities in sCO 2 fluid properties near the critical point and by changes in system inventory for efficient load management. In this study, the oscillatory behavior during load ramping is first shown and then two potential control solutions for substantially reducing oscillations are given: 1) the use of the main compressor inlet guide vanes (IGV) and 2) bypassing a portion of the sCO 2 around the cooler to maintain the MCIT. These control methods reduce the effect of cycle feedback from interactions between the MCIT and load. When implementing either control method, a load setpoint ramp of 7.5%/min was maintainable while achieving closer load setpoint tracking with limited oscillations. Finally, the impact of sensor noise on the control was examined since derivative action was used in the IGV and cooler sCO 2 bypass control. Finally, while some effect was evident, signal noise was not problematic to the control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of end-of-shift respirable crystalline silica monitoring to construction

A pilot project was conducted to determine the effect of common construction dusts as interferences in a new portable end-of-shift (EoS), direct-on-filter (DoF) sampling and analysis method for respirable crystalline silica (RCS), in this case, quartz. Construction dusts were prepared from plaster, drywall, cement and brick by grinding, aerosolizing, and collecting respirable dust with high flow rate cyclones. Filters were loaded with different levels of commercial α-quartz powder Min-u-Sil 5, and different levels of interfering dusts, singly and in combination. Samples were analyzed by Fourier Transform Infrared Spectroscopy (FTIR). Good correlations were found between nominal quartz loading (0 µg, 25 µg, 50 µg, and 100 µg) adjusted for quartz in the interfering dust and FTIR absorbance alone and in the presence of all interfering dusts. The slopes of the correlations were similar whether the loading was quartz without interference, or with plaster, drywall, and cement dusts, regardless of quantity. The results show that (a) plaster and drywall dusts do not interfere substantially; (b) cement does not interfere, but a change in the intercept suggests an effect on the background absorbance of the filter; and (c) in addition to having a substantial quartz content, brick dust contains an additional material, probably a silicate mineral, which interferes with the quartz peak. Thus, the presence of cement leads to lower quartz values and brick leads to higher values, but overall, 83% of the quartz contents predicted from the calibration data agreed within 50% of the adjusted nominal loadings within the range 20–110 µg. This result is encouraging given the high levels of interfering dusts. Nine samples loaded with smaller amounts of all four dusts together gave results within 25% of the adjusted nominal loadings. A single mixture addition of the dusts to the filter gave tighter variance in results than sequential additions. Unexpectedly, the two Certified Reference Materials (CRMs) 1878a and 1878b, gave different results when used to calibrate XRD analysis of Min-u-Sil 5.

42 ENGINEERING↗