Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

High-temperature nuclear magnetic resonance study of phase transition kinetics in LiNaSO{sub 4}

A new high-temperature NMR technique for measurements of the phase transition kinetics in solids has been developed. The technique allows measuring the time evolution of the volume of the appearing phase at controlled cooling rates. Developed method was applied to study the phase transition kinetics in the superionic conductor LiNaSO{sub 4}. It was revealed that the phase transition in LiNaSO{sub 4} is governed by the diffusion-controlled growth of nuclei (“germs”). An effect of the crystallite rearrangement in the LiNaSO{sub 4} powder after cooling through the phase transition was also revealed. This effect was studied by means of high-temperature XRD and NMR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Difference between healthy children and ADHD based on wavelet spectral analysis of nuclear magnetic resonance images

The main goal of this project was to create a computer algorithm based on wavelet analysis of region of homogeneity images obtained during resting state studies. Ideally it would automatically diagnose ADHD. Because the cerebellum is an area known to be affected by ADHD, this study specifically analysed this region. Male right handed volunteers (infants with ages between 7 and 11 years old) were studied and compared with age matched controls. Statistical differences between the values of the absolute integrated wavelet spectrum were found and showed significant differences (p<0.0015) between groups. This difference might help in the future to distinguish healthy from ADHD patients and therefore diagnose ADHD. Even if results were statistically significant, the small size of the sample limits the applicability of this methods as it is presented here, and further work with larger samples and using freely available datasets must be done.

60 APPLIED LIFE SCIENCES↗

Evaluating Mesorectal Lymph Nodes in Rectal Cancer Before and After Neoadjuvant Chemoradiation Using Thin-Section T2-Weighted Magnetic Resonance Imaging

Purpose: To apply thin-section T2-weighted magnetic resoance imaging (MRI) to evaluate the number, size, distribution, and morphology of benign and malignant mesorectal lymph nodes before and after chemoradiation treatment compared with histopathologic findings. Methods and Materials: Twenty-five patients with poor-risk adenocarcinoma of the rectum treated with neoadjuvant chemoradiation were evaluated prospectively. Thin-section T2-weighted MR images obtained before and after chemoradiation treatment were independently reviewed in consensus by 2 expert radiologists to determine the tumor stage, nodal size, nodal distribution, and nodal stage. Total mesorectal excision surgery after chemoradiation allowed MR nodal stage to be compared with histopathology using {kappa} statistics. Nodal downstaging was compared using the Chi-square test. Results: Before chemoradiation, 152 mesorectal nodes were visible (mean, 6.2 mm; 100 benign, 52 malignant) and 4 of 52 malignant nodes were in contact with the mesorectal fascia. The nodal staging was 7/25 N0, 10/25 N1, and 7/25 N2. After chemoradiation, only 29 nodes (mean, 4.1 mm; 24 benign, 5 malignant) were visible, and none were in contact with the mesorectal fascia. Nodal downstaging was observed: 20/25 N0 and 5/25 N1 (p < 0.01, Chi-square test). There was good agreement between MRI and pathologic T-staging ({kappa} = 0.64) and N-staging ({kappa} = 0.65) after chemoradiation. Conclusions: Neoadjuvant chemoradiation treatment resulted in a decrease in size and number of malignant- and benign-appearing mesorectal nodes on MRI. Nodal downstaging and nodal regression from the mesorectal fascia were observed after treatment. MRI is a useful tool for assessing nodal response to neoadjuvant treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification of breast calcification using magnetic resonance imaging

MRI phase and magnitude images provide information about local magnetic field variation ({Delta}B{sub 0}), which can consequently be used to understand tissue properties. Often, phase information is discarded. However, corrected phase images are able to produce contrast as a result of magnetic susceptibility differences and local field inhomogeneities due to the presence of diamagnetic and paramagnetic substances. Three-dimensional (3D) susceptibility weighted imaging (SWI) can be used to probe changes in MRI phase evolution and, subsequently, result in an alternate form of contrast between tissues. For example, SWI has been useful in the assessment of negative phase induced {Delta}B{sub 0} modulation due to the presence of paramagnetic substances such as iron. Very little, however, has been done to assess positive phase induced contrast changes resulting from the presence of diamagnetic substances such as precipitated calcium. As ductal carcinoma in situ, which is the precursor of invasive ductal cancer, is often associated with breast microcalcification, the authors proposed using SWI as a possible visualization technique. In this study, breast phantoms containing calcifications (0.4-1.5 mm) were imaged using mammography, computed tomography (CT), and SWI. Corrected phase and magnitude images acquired using SWI allowed identification and correlation of all calcifications seen on CT. As the approach is a 3D technique, it could potentially allow for more accurate localization and biopsy and maybe even reduce the use of gadolinium contrast. Furthermore, the approach may be beneficial to women with dense breast tissue where the ability to detect microcalcification with mammography is reduced.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observing the Surface Termination of LaScO 3 Perovskite Using Solid-State Nuclear Magnetic Resonance

Materials with well-defined surfaces are drawing increased attention for the design of bespoke catalysts and nanomaterials. Gaining a detailed understanding of the surfaces of these materials is an important challenge, which is often complicated by surface polymorphism and dynamic restructuring. We introduce the use of surface-enhanced NMR spectroscopy for the observation of such surfaces, focusing on LaScO 3 as an example. Here, we show that double-resonance NMR experiments correlating surface oxygen and probe molecules to the 139 La and 45 Sc nuclei at the surface reveal the material to be terminated by a ScO x monolayer. Surface-selective 17 O and 45 Sc NMR experiments further showed the material to be hydroxyl terminated and that the surface may be prone to dynamic restructuring as a result of moisture exposure. Perhaps most interestingly, surface-selective 139 La NMR experiments revealed the existence of previously undetected surface lanthanum defects, suggesting that surface-enhanced NMR may be useful as a guide in the synthesis of defect-free surfaces in the design of various nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring the Crystallinity Index of Cellulose by Solid State 13C Nuclear Magnetic Resonance

The crystallinity index of cellulose is an important parameter to establish because of the effect this property has on the utilization of cellulose as a material and as a feedstock for biofuels production. However, it has been found that the crystallinity index varies significantly depending on the choice of instrument and data analysis technique applied to the measurement. We introduce in this study a simple and straightforward method to evaluate the crystallinity index of cellulose. This novel method was developed using solid state {sup 13}C NMR and subtraction of the spectrum of a standard amorphous cellulose. The crystallinity indexes of twelve different celluloses were measured and the values from this method were compared with the values obtained by other existing methods, including methods based on X-ray diffraction. An interesting observation was that the hydration of the celluloses increased their crystallinity indexes by about 5%, suggesting that addition of water increased cellulose order for all the cellulose samples studied.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗

Correcting magnetic resonance k-space data for in-plane motion using an optical position tracking system

Purpose: Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. Methods: In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion data that were used subsequently to correct the position and phase of recorded k-space samples. Motion data can be acquired with a temporal resolution of 60 Hz and spatial accuracy of 0.1 mm for translations and 0.2 deg. for rotations. Results: Significant improvements of image quality are demonstrated. Conclusions: The key advantages of the technique are that it is easy to implement, does not interfere with or complicate MR data acquisition, and is capable of correcting distortions within a single slice. Therefore, the technique has the potential to improve upon approaches that rely on the registration or realignment of successive imaging slices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probing the Dynamics of a Protein Hydrophobic Core by Deutron Solid-State Nuclear Magnetic Resonance Spectroscopy

With the goal of investigating dynamical features of hydrophobic cores of proteins over a wide range of temperatures, the villin headpiece subdomain protein (HP36) was labeled at a "single" site corresponding to any one of the two -C5D3 groups of Leucine-69, which is located in a key position of the core. The main techniques employed are deuteron NMR quadrupolar echo line shape analysis, and T1Z (Zeeman) and T1Q (Quadrupolar order) relaxation experiments performed at 11.7 and 17.6T over the temperature range of 112 to 298K. The experimental data are compared with computer simulations. The deuteron line shapes give an excellent fit to a three-mode motional model that consists of a) fast 3-site rotational jumps about the pseudo C3 methyl spinning axis, b) slower reorientation of the spinning axis, described by diffusion along a restricted arc and c) large angle jumps between traces of rotameric conformers. Relaxation behavior is described by a phenomenological distribution of activation energies for 3-site hops at high temperatures that collapses to a single, distinctly smaller value for lower temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Fragment-based {sup 13}C nuclear magnetic resonance chemical shift predictions in molecular crystals: An alternative to planewave methods

We assess the quality of fragment-based ab initio isotropic {sup 13}C chemical shift predictions for a collection of 25 molecular crystals with eight different density functionals. We explore the relative performance of cluster, two-body fragment, combined cluster/fragment, and the planewave gauge-including projector augmented wave (GIPAW) models relative to experiment. When electrostatic embedding is employed to capture many-body polarization effects, the simple and computationally inexpensive two-body fragment model predicts both isotropic {sup 13}C chemical shifts and the chemical shielding tensors as well as both cluster models and the GIPAW approach. Unlike the GIPAW approach, hybrid density functionals can be used readily in a fragment model, and all four hybrid functionals tested here (PBE0, B3LYP, B3PW91, and B97-2) predict chemical shifts in noticeably better agreement with experiment than the four generalized gradient approximation (GGA) functionals considered (PBE, OPBE, BLYP, and BP86). A set of recommended linear regression parameters for mapping between calculated chemical shieldings and observed chemical shifts are provided based on these benchmark calculations. Statistical cross-validation procedures are used to demonstrate the robustness of these fits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-photon Lee-Goldburg nuclear magnetic resonance: Simultaneous homonuclear decoupling and signal acquisition

We present NMR signals from a strongly coupled homonuclear spin system, {sup 1}H nuclei in adamantane, acquired with simultaneous two-photon excitation under conditions of the Lee-Goldburg experiment. Small coils, having inside diameters of 0.36 mm, are used to achieve two-photon nutation frequencies of {approx}20 kHz. The very large rf field strengths required give rise to large Bloch-Siegert shifts that cannot be neglected. These experiments are found to be extremely sensitive to inhomogeneity of the applied rf field, and due to the Bloch-Siegert shift, exhibit a large asymmetry in response between the upper and lower Lee-Goldburg offsets. Two-photon excitation has the potential to enhance both the sensitivity and performance of homonuclear dipolar decoupling, but is made challenging by the high rf power required and the difficulties introduced by the inhomogeneous Bloch-Siegert shift. We briefly discuss a variation of the frequency-switched Lee-Goldburg technique, called four-quadrant Lee-Goldburg (4QLG) that produces net precession in the x-y plane, with a reduced chemical shift scaling factor of 1/3.

36 MATERIALS SCIENCE↗

Emphysema Quantification in Inflation-Fixed Lungs Using Low-Dose Computed Tomography and 3He Magnetic Resonance Imaging

Abstract: Objective: To evaluate the use of inflation-fixed lung tissue for emphysema quantification with CT and 3He MR diffusion imaging. Methods: Fourteen subjects representing a range of chronic obstructive pulmonary disease severity who underwent complete or lobar lung resection were studied. CT measurements of lung attenuation and MR measurements of the hyperpolarized 3He apparent diffusion coefficient (ADC) in resected specimens fixed in inflation with heated formalin vapor were compared with measurements obtained before fixation. Results: The mean CT emphysema index was 56% ± 17% before and 58% ± 19% after fixation (P=0.77;R=0.76). Index differences correlated with differences in lung volume (R2=0.47). The mean 3He ADC was 0.40 ± 0.15 cm2/sec before and 0.39 ± 0.14 cm2/sec after fixation (P=0.03, R=0.98). The CT emphysema index and the 3He ADC were correlated before (R=0.89) and after fixation (R=0.79). Conclusion: Concordance of CT and 3He MR imaging measurements in unfixed and inflation-fixed lungs supports the use of inflation-fixed lungs for quantitative imaging studies in emphysema.

60 APPLIED LIFE SCIENCES↗

Electron density distribution in BaPb{sub 1-x}Sb{sub x}O{sub 3} superconducting oxides studied by double nuclear magnetic resonance methods

The effect of charge disorder on the formation of an inhomogeneous state of the electron system in the conduction band in BaPb{sub 1-x}Sb{sub x}O{sub 3} superconducting oxides is investigated experimentally by NMR methods. The NMR spectra of {sup 17}O are measured systematically, and the contributions from {sup 17}O atoms with different cation nearest surroundings are identified. It is found that microscopic regions with an elevated spin density of charge carriers are formed within two coordination spheres near antimony ions. Nuclei of the superconducting phase of the oxide (regions with an elevated antimony concentration) microscopically distributed over the sample are detected in compounds with x = 0.25 and 0.33. Experiments in which a double resonance signal of the spin echo of {sup 17}O-{sup 207}Pb and {sup 17}O-{sup 121}Sb are measured in the metal phase of BaPb{sub 1-x}Sb{sub x}O{sub 3} oxides are carried out for the first time. The constants of indirect heteronuclear spin-spin {sup 17}O-{sup 207}Pb interaction are determined as functions of the local Knight shift {sub 207}Ks. The estimates of the constants of the indirect interaction between the nuclei of the nearest neighbors (O-Pb and Pb-Pb atoms) and analysis of evolution of the NMR spectra of {sup 17}O upon a change in the antimony concentration are convincing evidence in favor of the development of a microscopically inhomogeneous state of the electron system in the metal phase of BaPb{sub 1-x}Sb{sub x}O{sub 3} oxides.

36 MATERIALS SCIENCE↗

Site-specific solvent exposure analysis of a membrane protein using unnatural amino acids and {sup 19}F nuclear magnetic resonance

Highlights: {yields} Solvent isotope shift analysis of {sup 19}F-tfmF in different H{sub 2}O/D{sub 2}O molar ratio. {yields} Correlation between solvent isotope shift of {sup 19}F-spins and solvent exposure analysis. {yields} Solvent exposure analysis of membrane proteins. -- Abstract: Membrane proteins play an essential role in cellular metabolism, transportation and signal transduction across cell membranes. The scarcity of membrane protein structures has thus far prevented a full understanding of their molecular mechanisms. Preliminary topology studies and residue solvent exposure analysis have the potential to provide valuable information on membrane proteins of unknown structure. Here, a {sup 19}F-containing unnatural amino acid (trimethylfluoro-phenylalanine, tfmF) was applied to accomplish site-specific {sup 19}F spin incorporation at different sites in diacylglycerol kinase (DAGK, an Escherichia coli membrane protein) for site-specific solvent exposure analysis. Due to isotope effect on {sup 19}F spins, a standard curve for {sup 19}F-tfmF chemical shifts was drawn for varying solvent H{sub 2}O/D{sub 2}O ratios. Further site-specific {sup 19}F solvent isotope shift analysis was conducted for DAGK to distinguish residues in water-soluble loops, interfacial areas or hydrophobic membrane regions. This site-specific solvent exposure analysis method could be applied for further topological analysis of other membrane proteins.

60 APPLIED LIFE SCIENCES↗

High-pressure magic angle spinning nuclear magnetic resonance

A high-pressure magic angle spinning (MAS) NMR capability, consisting of a reusable high-pressure MAS rotor, a high-pressure rotor loading/reaction chamber for in situ sealing and re-opening of the high-pressure MAS rotor, and a MAS probe with a localized RF coil for background signal suppression, is reported. The unusual technical challenges associated with development of a reusable high-pressure MAS rotor are addressed in part by modifying standard ceramics for the rotor sleeve by abrading the internal surface at both ends of the cylinder. In this way, not only is the advantage of ceramic cylinders for withstanding very high-pressure utilized, but also plastic bushings can be glued tightly in place so that other removable plastic sealing mechanisms/components and O-rings can be mounted to create the desired high-pressure seal. Using this strategy, sealed internal pressures exceeding 150 bars have been achieved and sustained under ambient external pressure with minimal loss of pressure for 72 h. Finally, as an application example, in situ 13 C MAS NMR studies of mineral carbonation reaction intermediates and final products of forsterite (Mg 2 SiO 4 ) reacted with supercritical CO 2 and H 2 O at 150 bar and 50 °C are reported, with relevance to geological sequestration of carbon dioxide.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic resonance imaging findings of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion in adults: a pilot study

Purpose: The purpose of the study was to retrospectively analyze MRI findings of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion (Xp11.2/TFE RCC) in adults. Methods: Sixteen patients with Xp11.2/TFE RCC were reviewed retrospectively. The clinical characteristics and imaging features were assessed and then compared between metastatic and non-metastatic subgroups. Results: The mean age at diagnosis was 47.4 (20–76) years. Seven (44 %) patients were men, and nine (56 %) patients were women. The lesions predominantly exhibited an endophytic distribution (n = 14, 88 %) with a capsule (n = 16, 100 %), accompanied by solid and cystic patterns (n = 12, 75%) and hemorrhage (n = 11, 69 %). The tumors prevalently appeared hyper- to isointense on T1WI (n = 14, 88 %), hypointense on T2WI (n = 13, 81 %), and hyperintense on DWI (n = 16, 100 %) with a lower ADC (P < 0.001) than that of the surrounding tissue. The tumors were less enhanced than the normal renal cortex in all phases with a prolonged enhancement pattern (P ≤ 0.001). In addition, six patients (38 %) developed recurrence or metastases. The RCCs with metastases showed an irregular shape (P = 0.013), an incomplete capsule (P = 0.018), heterogeneous solid-cystic patterns (P = 0.034), and hemorrhage (P = 0.037) than non-metastatic subgroups. Conclusions: MRI provides valuable information for the diagnosis of adult Xp11.2/TFE RCCs. Features including irregular shape, incomplete capsule, mixed solid-cystic pattern, and hemorrhage may indicate the occurrence of recurrence or metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic resonance elastography SE-EPI vs GRE sequences at 3T in a pediatric population with liver disease

Purpose: The goal of our study is to compare hepatic stiffness measures using gradient-recalled echo (GRE) versus spin-echo echo planar imaging (SE-EPI)-based MR Elastography (MRE) at 3T used to measure hepatic stiffness in a patients with suspected liver diseases. Materials and methods: This retrospective study included 52 patients with liver disease who underwent a 3T MRE exam including both an investigational SE-EPI-based technique and a product GRE-based technique. Regions of interest (ROI) were placed on the elastograms to measure elastography-derived liver stiffness as well as the area included within the ROIs. The mean liver stiffness values and area of ROIs were compared. Results: The mean liver stiffness was 3.72 kilopascal (kPa) ± 1.29 using GRE MRE and 3.78 kPa ± 1.13 using SE-EPI MRE. Measurement of liver stiffness showed excellent agreement between the two pulse sequences with a mean bias of − 0.1 kPa (range − 1.8 to 1.7 kPa) between sequences. The mean measurable ROI area was higher with SE-EPI (313.8 cm{sup 2} ± 213.8) than with the GRE technique (208.6 cm{sup 2} ± 114.8), and the difference was statistically significant (P < 0.05). Conclusions: Our data shows excellent agreement of measured liver stiffness between GRE and SE-EPI-based sequences at 3T. Our results show the advantage of a SE-EPI MRE sequence in terms of image quality, ROI size and acquisition time with equivalent liver stiffness measurements as compared to GRE-MRE sequence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficiency Improvement in a Busy Radiology Practice: Determination of Musculoskeletal Magnetic Resonance Imaging Protocol Using Deep-Learning Convolutional Neural Networks

The purposes of this study are to evaluate the feasibility of protocol determination with a convolutional neural networks (CNN) classifier based on short-text classification and to evaluate the agreements by comparing protocols determined by CNN with those determined by musculoskeletal radiologists. Following institutional review board approval, the database of a hospital information system (HIS) was queried for lists of MRI examinations, referring department, patient age, and patient gender. These were exported to a local workstation for analyses: 5258 and 1018 consecutive musculoskeletal MRI examinations were used for the training and test datasets, respectively. The subjects for pre-processing were routine or tumor protocols and the contents were word combinations of the referring department, region, contrast media (or not), gender, and age. The CNN Embedded vector classifier was used with Word2Vec Google news vectors. The test set was tested with each classification model and results were output as routine or tumor protocols. The CNN determinations were evaluated using the receiver operating characteristic (ROC) curves. The accuracies were evaluated by a radiologist-confirmed protocol as the reference protocols. The optimal cut-off values for protocol determination between routine protocols and tumor protocols was 0.5067 with a sensitivity of 92.10%, a specificity of 95.76%, and an area under curve (AUC) of 0.977. The overall accuracy was 94.2% for the ConvNet model. All MRI protocols were correct in the pelvic bone, upper arm, wrist, and lower leg MRIs. Deep-learning-based convolutional neural networks were clinically utilized to determine musculoskeletal MRI protocols. CNN-based text learning and applications could be extended to other radiologic tasks besides image interpretations, improving the work performance of the radiologist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed tomographic perfusion with 160-mm coverage: comparative analysis of hepatocellular carcinoma treated by two transarterial chemoembolization courses relative to magnetic resonance imaging findings

Purpose: The aim of this study was to assess hepatocellular carcinoma (HCC) response with CT perfusion parameters before and after two transarterial chemo embolization (TACE) courses compared with MRI, and to search for predictive factors of response. Methods: 37 lesions (19 patients) were included between October 2015 and September 2017, based on the Barcelona Clinic Liver Cancer guidelines. CT perfusion with 160-mm coverage and MRI were performed before and after the first TACE course, and after the second TACE course. Quantitative perfusion parameters were compared to the response assessed with MRI using mRECIST criteria, defining response groups: complete response (CR), partial response (PR), no response (NR), response (including CR and PR), no complete response (NCR, including PR and NR). Results: Pre-TACE blood flow (BF) and hepatic arterial blood flow (HABF) were significantly higher in lesions with post-TACE 1 CR than in those with NCR (BF: 118.8 vs. 76.3 mL/100 g/min, p = 0.0231; HABF: 76 vs. 44.2 mL/100 g/min, p = 0.0112). Pre-TACE time to peak (TTP) and mean transit time (MTT) were significantly lower in lesions with post-TACE 2 response than in those with NR (TTP: 31.5 vs. 46.1 s, p = 0.0313; MTT: 15.8 vs. 22.8 s, p = 0.0204). Post-TACE 1 and post-TACE 2 perfusion parameters did not exhibit any statistically significant differences relative to MRI response. Conclusion: Our study did not find, after a first TACE course, perfusion parameters associated with a response to a second TACE course. However, baseline perfusion parameters analysis could lead to better therapeutic management of HCC by targeting lesions likely to respond well to TACE courses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗