Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic superconductivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Machine learning study of magnetism in uranium-based compounds

Actinide and lanthanide-based materials display exotic properties that originate from the presence of itinerant or localized f electrons and include unconventional superconductivity and magnetism, hidden order, and heavy-fermion behavior. Due to the strongly correlated nature of the 5f electrons, magnetic properties of these compounds depend sensitively on applied magnetic field and pressure, as well as on chemical doping. However, precise connection between the structure and magnetism in actinide-based materials is currently unclear. In this investigation, we established such structure-property links by assembling and mining two datasets that aggregate, respectively, the results of high-throughput density functional theory simulations and experimental measurements for the families of uranium- and neptunium-based binary compounds. Various regression algorithms were utilized to identify correlations among accessible attributes (features or descriptors) of the material systems and predict their cation magnetic moments and general forms of magnetic ordering. Descriptors representing compound structural parameters and cation f-subshell occupation numbers were identified as most important for accurate predictions. The best machine learning model developed employs the random forest regression algorithm. It can predict both spin and orbit moment size with root-mean-square error of 0.17 μ B and 0.19 μ B , respectively. Lastly, the random forest classification algorithm is used to predict the ordering (paramagnetic, ferromagnetic, and antiferromagnetic) of such systems with 76% accuracy.

36 MATERIALS SCIENCE↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Development and performance of a 2.9 Tesla dipole magnet using high-temperature superconducting CORC® wires

Although the high-temperature superconducting (HTS) REBa 2 Cu 3 O x (REBCO, RE-rare earth elements) material has a strong potential to enable dipole magnetic fields above 20 T in future circular particle colliders, the magnet and conductor technology needs to be developed. As part of an ongoing development to address this need, here we report on our CORC® canted cosθ magnet called C2 with a target dipole field of 3 T in a 65 mm aperture. The magnet was wound with 70 m of 3.8 mm diameter CORC® wire on machined metal mandrels. The wire had 30 commercial REBCO tapes from SuperPower Inc. each 2 mm wide with a 30 µm thick substrate. The magnet generated a peak dipole field of 2.91 T at 6.290 kA, 4.2 K. The magnet could be consistently driven into the flux-flow regime with reproducible voltage rise at an engineering current density between 400-550 A mm -2 , allowing reliable quench detection and magnet protection. The C2 magnet represents another successful step towards the development of high-field accelerator magnet and CORC® conductor technologies. The test results highlighted two development needs: continue improving the performance and flexibility of CORC® wires and develop the capability to identify locations of first onset of flux-flow voltage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical Performance of the First Two Prototype 4.5 m Long Nb$_3$Sn Low-$β$ Quadrupole Magnets for the Hi-Lumi LHC Upgrade

The U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) team is collaborating with CERN in the design and fabrication of the first 4.5 m long MQXFA magnets, a 150 mm aperture high-field Nb$_3$Sn quadrupole magnet that uses the aluminum shell-based bladder-and-key technology. The first two prototype magnets, MQXFAP1 and MQXFAP2, were assem-bled and tested while the first pre-series structure (MQXFA03) was in fabrication. This paper summarizes the mechanical perfor-mance of these prototype structures based on the comparison of measured strain gauge data with finite element model analyses from all load steps to powering. The MQXFAP1 magnet almost reached ultimate current before a short to ground was detected and the test was stopped. The MQXFAP2 magnet experienced a low training performance due to a fractured aluminum shell. MQXFAP1b was rebuilt with a new replacement coil, but an old coil limited the magnet from achieving the ultimate current. The mitigations and analyses of these prototype magnets are discussed in the context of the transition to pre-series production.

43 PARTICLE ACCELERATORS↗

Superconducting rock magnetometer system

A three axis magnetometer system intended for use in the magnetic measurement of lunar rock samples was designed, fabricated and delivered to NASA Manned Spacecraft Center. The system has a four inch diameter room temperature sample access region and is fitted with three orthogonal magnetic field sensors enclosing this region. Two superconducting magnetic shields are incorporated, which are designed to eliminate external magnetic noise from the sense coils. A superconducting solenoid is mounted coaxially with the sample region and this provides axial magnetic fields up to 1,000 gauss. The system was designed for measuring magnetic moments of geophysical samples, especially remanent moments of lunar samples. The sensitivity of the system in all three axes is about 2 x 10 to the -7th power EMU square root HZ peak to peak, measured in the 0 to 1 Hz bandwidth.

Source record↗

Development of a second COMB dipole magnet with STAR wires

Rare-Earth Barium Copper Oxide (REBCO) coated conductors are an attractive option for application in high-field accelerator magnets due to their high critical field and the convenience of fabrication without heat treatment compared to some other superconductors. Fermilab plays a vital role in superconducting accelerator magnet R&D under the framework of the U.S. Magnet Development Program. An integral part of that program is the accelerator magnet development based on REBCO conductors to demonstrate self-fields of 5 T or greater compatible with operation in hybrid configurations to generate fields beyond 16 T for future High Energy Physics (HEP) applications. A small, two-layer REBCO dipole magnet based on the Conductor on Molded Barrel (COMB) magnet technology, developed at Fermilab with Symmetric Tape Round (STAR®) wires from AMPeers LLC was recently fabricated and tested in liquid helium, demonstrating the design feasibility. A second dipole magnet based on the same technology is currently under development at Fermilab. The coil has a 60-mm clear bore and a 120-mm OD and consists of six layers of STAR® conductor, which allows to significantly increase the magnetic field compared to the previous design, and potentially probe the 5 T self-field target. This presentation reports the progress in the magnet development.

Kashikhin, Vadim [Fermilab]↗

Magnetic properties of the 110K superconducting phase in Pb-doped Bi-Sr-Ca-Cu-O thin films

The relaxation of the remnant moment induced in a nearly single phase high T(sub c) thin film of Pd-doped Bi-Sr-Ca-Cu-O was investigated. Measurements reveal that the relaxation obeys a logarithmic time dependence for observation times up to 2000 seconds. The temperature dependence of the initial magnetization of the film and its decay rate are obtained. The initial magnetization monotonically decreases. However, the decay rate normalized by initial magnetization has a peak at approximately 14 K for an applied field of 500 gauss. The peak shifts to lower temperature for a stronger magnetic field. These data are compared with existing data on other high T(sub c) superconducting materials.

Tanaka, Atsushi↗

Quench Detection and Protection for High-Temperature Superconductor Accelerator Magnets

High-temperature superconductors (HTS) are being increasingly used for magnet applications. One of the known challenges of practical conductors made with high-temperature superconductor materials is a slow normal zone propagation velocity resulting from a large superconducting temperature margin in combination with a higher heat capacity compared to conventional low-temperature superconductors (LTS). As a result, traditional voltage-based quench detection schemes may be ineffective for detecting normal zone formation in superconducting accelerator magnet windings. A developing hot spot may reach high temperatures and destroy the conductor before a practically measurable resistive voltage is detected. The present paper discusses various approaches to mitigating this problem, specifically focusing on recently developed non-voltage techniques for quench detection.

Marchevsky, Maxim (ORCID:0000000172839305)↗

Spin correlations in the nematic quantum disordered state of FeSe

The quantum-disordered state in FeSe, intertwined with superconductivity and nematicity, has been a research focus in iron-based superconductors. However, the intrinsic spin excitations across the entire Brillouin zone in detwinned FeSe, crucial for understanding its magnetism and superconductivity, have remained unresolved. Using inelastic neutron scattering, we reveal that stripe spin excitations (Q = (1, 0)/(0, 1)) exhibit the C 2 symmetry, while Néel spin excitations (Q = (1, 1)) retain C 4 symmetry within the nematic state. Temperature-dependent differences between Q = (1, 0) and (0, 1) spin excitations above the structural transition unambiguously reveals the nematic quantum disordered state. Comparison with NaFeAs suggests the Néel excitations originate from enhanced 3d xy orbital correlations. Modeling the stripe dispersions using a J 1 -K-J 2 Heisenberg Hamiltonian, we establish a spin-interaction phase diagram, positioning FeSe near a crossover regime between the antiferroquadrupolar, Néel, and stripe orders. Our results provide key insights into the microscopic spin interactions and their role in the intertwined orders in iron-based superconductors.

Electronic properties and materials↗

Scaling behavior of low-temperature orthorhombic domains in the prototypical high-temperature superconductor La 1.875 Ba 0.125 CuO 4

Structural symmetry breaking and recovery in condensed-matter systems are closely related to exotic physical properties such as superconductivity (SC), magnetism, spin density waves, and charge density waves (CDWs). The interplay between different order parameters is intricate and often subject to intense debate, as in the case of CDW order and superconductivity. In La 1.875 Ba 0.125 CuO 4 (LBCO), the low-temperature structural domain walls are hypothesized as nanometer-scale pinning sites for the CDWs. Coherent x-ray diffraction techniques have been employed here to visualize the domain structures associated with these symmetry changes directly during phase transition. We have pushed Bragg coherent diffractive imaging (BCDI) into the cryogenic regime where most phase transitions in quantum materials reside. Utilizing BCDI, we image the structural evolution of LBCO microcrystal samples during the high-temperature tetragonal to low-temperature orthorhombic (LTO) phase transition. Our results show the formation of LTO domains close to the transition temperature and how the domain size decreases with temperature. In conclusion, the number of domains follows the secondary order parameter (or orthorhombic strain) measurement with a critical exponent that is consistent with the three-dimensional universality class.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical Design of the MARCO Solenoid Detector Magnet

MARCO is the superconducting solenoid for ePIC, the new particle physics detector of the upcoming Electron Ion Collider (EIC) at the Brookhaven National Laboratory (NY, USA). The magnet has a 2.84 m warm bore diameter and is 3.85 m long. This 15 tons magnet provides a 2.0 T central field at the interaction point with a nominal current of about 4 kA at 4.5 K. The coil is composed of 6 layers of copper stabilized NbTi Rutherford in channel conductor (RIC) and it is wound internally to the brass mandrel. Here, this paper presents the detailed mechanical design of the magnet, starting with the magnet description, the material properties and the acceptance criteria considered. Then, the coil pack properties homogenization process is described. Subsequently, the 2D and 3D calculation models and their assumptions are described. At last, the computational results for the cool down and the energization are discussed. Index Terms—Superconducting Detector Magnet, material properties, homogenization, detector, EIC.

Reymond, Hugo [Commissariat a l'Energie Atomique e↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Software Architecture and Hardware Organization in Mu2e Solenoid Field Mapping System

Herein, the Mu2e field mapping system is designed to produce high accuracy field maps of the detector solenoid used in the experiment. The data acquisition system is mobile and uses a self-propelled mapper with rotating arms equipped with 3D Hall probes. The measurements require not only accurate magnetic field readouts, but also accurate locations of all Hall probes while measuring data. The latter is accomplished by using the laser tracker to measure positions of several retroreflectors on the field mapper during data acquisition. The measurement process requires scanning the whole space inside the large solenoid and takes many hours to complete, which necessitates its full automation. The automation software includes control of the mapper, readout of Hall and NMR probes and control of a laser tracker, including prediction of retroreflector positions and execution of quality control checks. The software architecture and data acquisition hardware of the field mapping system are described, with special attention given to control of the laser tracker and its integration with the rest of the system.

3d hall probes↗

Probing and manipulating magnetic and 2D quantum materials using ultrafast laser and high harmonic sources

The ability to probe the full dynamic response of quantum materials on the length- and time-scales (Å to attoseconds on up) fundamental to charge, spin and phonon interactions is leading to a host of new discoveries. The coupled interactions between charges, spins, orbital and lattice degrees of freedom are key to determining the state of a material, whether metallic, insulating, superconducting or magnetic. Under thermal equilibrium conditions these states can be tuned by varying the temperature, pressure, chemical doping or dimensionality. However, their inherent complexity and rich phase landscape make them challenging to understand or manipulate deterministically. Fortunately, ultrafast light sources have undergone remarkable advances in recent years, achieving what was merely a dream three decades ago, i.e., full coherent control of light fields spanning the THz to the X-ray regions. Here, these new capabilities are providing powerful new tools for coherently manipulating and probing quantum materials using light. Recent advances in high harmonic generation (HHG) have provided new techniques for uncovering new phases and couplings in 2D and magnetic materials, using femtosecond lasers to coherently manipulate and tune the properties and interactions in the material, and HHG as a probe to map out these new phases and couplings. There are several beautiful recent observations of exciting new states in materials using light, but in some cases, the limited experimental data points made it challenging to validate an interpretation. The new ability of ultrafast HHG-based photoemission and magneto-optic spectroscopies to precisely probe multiple phases, electronic and magnetic order parameters, when combined with scanning the laser excitation fluence, is allowing us to map how material phases, magnetic states, and electron-phonon-spin couplings in these delicate materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superconducting Effects in Optimization of Magnetic Penetration Thermometers for X-ray Microcalorimeters

Like MMCs, MPTs enable high energy microcalorimeters with zero bias power dissipation and potential resolution < 1 eV. MPTs can provide d(phi)/dT as large as 1000 (Phi)(sub 0)/K, with no excess noise, thereby reducing the importance of SQUID noise. Long coherence length in a Type-I superconducting MoAu film offers multiple advantages for efficient flux expulsion in MPT. Region of steepest d(phi)/dT is the Meissner effect in the small device; flux is expelled/penetrates to minimize free energy. Steepness of transition can be engineered with choice of film thickness and coil pitch relative to lambda(sub eff)(0), ratio of T/T(sub c), and bias circuit inductance.

Stevenson, T. R.↗