Search NASA⌕ Search

SEARCH · Search NASA

Results for “Marginal Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Biological Ocean Margins Program: Active Microbes Responding to Inputs from the Orinoco River Plume (Final Report)

The overall goal of the proposed work is to identify the active members of the heterotrophic community involved in C and N cycling in the perimeter of the Orinoco River Plume (ORP), assess their spatial distribution, quantify their metabolic activity, and correlate these parameters to plume properties such as salinity, organic matter content and phytoplankton biomass.

59 BASIC BIOLOGICAL SCIENCES↗

Informed total-error-minimizing priors: Interpretable cosmological parameter constraints despite complex nuisance effects

While Bayesian inference techniques are standard in cosmological analyses, it is common to interpret resulting parameter constraints with a frequentist intuition. This intuition can fail, for example, when marginalizing high-dimensional parameter spaces onto subsets of parameters, because of what has come to be known as projection effects or prior volume effects. We present the method of informed total-error-minimizing (ITEM) priors to address this problem. An ITEM prior is a prior distribution on a set of nuisance parameters, such as those describing astrophysical or calibration systematics, intended to enforce the validity of a frequentist interpretation of the posterior constraints derived for a set of target parameters (e.g., cosmological parameters). Our method works as follows. For a set of plausible nuisance realizations, we generate target parameter posteriors using several different candidate priors for the nuisance parameters. We reject candidate priors that do not accomplish the minimum requirements of bias (of point estimates) and coverage (of confidence regions among a set of noisy realizations of the data) for the target parameters on one or more of the plausible nuisance realizations. Of the priors that survive this cut, we select the ITEM prior as the one that minimizes the total error of the marginalized posteriors of the target parameters. As a proof of concept, we applied our method to the density split statistics measured in Dark Energy Survey Year 1 data. We demonstrate that the ITEM priors substantially reduce prior volume effects that otherwise arise and that they allow for sharpened yet robust constraints on the parameters of interest.

79 ASTRONOMY AND ASTROPHYSICS↗

Long-run Marginal Emission Rates for Electricity - Workbooks for 2021 Cambium Data

These workbooks contain modeled estimates of long-run marginal emission rates (LRMER) for the contiguous United States. The LRMER is an estimate of the rate of emissions that would be either induced or avoided by a long-term (i.e., more than several years) change in electrical demand. It incorporates both the projected changes to the electric grid, as well as the potential for an incremental change in electrical demand to influence the structural evolution of the grid (i.e., the building and retiring of capital assets, such as generators and transmission lines). It is therefore distinct from the more-commonly-known short-run marginal, which treats grid assets as fixed. The Levelized LRMER worksheet within each workbook is set up to produce a levelized long-run marginal emission rate based on user-provided inputs. These levelized LRMER values are intended for analysts to use when estimating the emissions induced (or avoided) by a long-term change in end-use electricity demand. There are two workbooks that supply the data at two different geographic resolutions: states and GEA regions (20 regions that are similar to, but not exactly the same as, the US EPA's eGRID regions). For more data underlying these emissions factors, see the Cambium 2021 project at https://cambium.nrel.gov/. For more details on the inputs into the scenarios available in the workbooks, see the Standard Scenarios 2021 Report (https://www.nrel.gov/docs/fy22osti/80641.pdf). This data was produced as part of the Cambium project. For more details about the methodology, see the Cambium Documentation: Version 2021 (https://www.nrel.gov/docs/fy22osti/81611.pdf). This data is planned to be updated annually. Information on the latest versions can be found at https://www.nrel.gov/analysis/cambium.html.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evidence of galaxy assembly bias in SDSS DR7 galaxy samples from count statistics

We present observational constraints on the galaxy–halo connection, focusing particularly on galaxy assembly bias from a novel combination of counts-in-cylinders statistics, P(N CIC ), with the standard measurements of the projected two-point correlation function w p (r p ), and number density n gal of galaxies. We measure n gal , w p (r p ), and P(N CIC ) for volume-limited, luminosity-threshold samples of galaxies selected from SDSS DR7, and use them to constrain halo occupation distribution (HOD) models, including a model in which galaxy occupation depends upon a secondary halo property, namely halo concentration. We detect significant positive central assembly bias for the M r < -20.0 and M r <-19.5 samples. Central galaxies preferentially reside within haloes of high concentration at fixed mass. Positive central assembly bias is also favoured in the M r < -20.5 and M r < -19.0 samples. We find no evidence of central assembly bias in the M r < -21.0 sample. We observe only a marginal preference for negative satellite assembly bias in the M r < -20.0 and M r < -19.0 samples, and non-zero satellite assembly bias is not indicated in other samples. Our findings underscore the necessity of accounting for galaxy assembly bias when interpreting galaxy survey data, and demonstrate the potential of count statistics in extracting information from the spatial distribution of galaxies, which could be applied to both galaxy–halo connection studies and cosmological analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

SUBSTELLAR OBJECTS IN NEARBY YOUNG CLUSTERS. VII. THE SUBSTELLAR MASS FUNCTION REVISITED

The abundance of brown dwarfs (BDs) in young clusters is a diagnostic of star formation theory. Here we revisit the issue of determining the substellar initial mass function (IMF) based on a comparison between NGC 1333 and IC348, two clusters in the Perseus star-forming region. We derive their mass distributions for a range of model isochrones, varying distances, extinction laws, and ages with comprehensive assessments of the uncertainties. We find that the choice of isochrone and other parameters have significant effects on the results, thus we caution against comparing IMFs obtained using different approaches. For NGC 1333, we find that the star/BD ratio R is between 1.9 and 2.4 for all plausible scenarios, consistent with our previous work. For IC348, R is found to be between 2.9 and 4.0, suggesting that previous studies have overestimated this value. Thus the star-forming process generates about 2.5-5 substellar objects per 10 stars. The derived star/BD ratios correspond to a slope of the power-law mass function of α = 0.7-1.0 for the 0.03-1.0 M{sub ☉} mass range. The median mass in these clusters—the typical stellar mass—is between 0.13 and 0.30 M{sub ☉}. Assuming that NGC 1333 is at a shorter distance than IC348, we find a significant difference in the cumulative distribution of masses between the two clusters, resulting from an overabundance of very low mass objects in NGC 1333. Gaia astrometry will constrain the cluster distances better and will lead to a more definitive conclusion. Furthermore, the star/BD ratio is somewhat larger in IC348 compared with NGC 1333, although this difference is still within the margins of error. Our results indicate that environments with higher object density may produce a larger fraction of very low mass objects, in line with predictions for BD formation through gravitational fragmentation of filaments falling into a cluster potential.

79 ASTRONOMY AND ASTROPHYSICS↗

Retroperitoneal Sarcoma Target Volume and Organ at Risk Contour Delineation Agreement Among NRG Sarcoma Radiation Oncologists

Purpose: The purpose of this study was to evaluate the variability in target volume and organ at risk (OAR) contour delineation for retroperitoneal sarcoma (RPS) among 12 sarcoma radiation oncologists. Methods and Materials: Radiation planning computed tomography (CT) scans for 2 cases of RPS were distributed among 12 sarcoma radiation oncologists with instructions for contouring gross tumor volume (GTV), clinical target volume (CTV), high-risk CTV (HR CTV: area judged to be at high risk of resulting in positive margins after resection), and OARs: bowel bag, small bowel, colon, stomach, and duodenum. Analysis of contour agreement was performed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. Results: Ten radiation oncologists contoured both RPS cases, 1 contoured only RPS1, and 1 contoured only RPS2 such that each case was contoured by 11 radiation oncologists. The first case (RPS 1) was a patient with a de-differentiated (DD) liposarcoma (LPS) with a predominant well-differentiated (WD) component, and the second case (RPS 2) was a patient with DD LPS made up almost entirely of a DD component. Contouring agreement for GTV and CTV contours was high. However, the agreement for HR CTVs was only moderate. For OARs, agreement for stomach, bowel bag, small bowel, and colon was high, but agreement for duodenum (distorted by tumor in one of these cases) was fair to moderate. Conclusions: For preoperative treatment of RPS, sarcoma radiation oncologists contoured GTV, CTV, and most OARs with a high level of agreement. HR CTV contours were more variable. Further clarification of this volume with the help of sarcoma surgical oncologists is necessary to reach consensus. More attention to delineation of the duodenum is also needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planck 2013 results. XXI. Power spectrum and high-order statistics of the Planck all-sky Compton parameter map

We have constructed the first all-sky map of the thermal Sunyaev-Zeldovich (tSZ) effect by applying specifically tailored component separation algorithms to the 100 to 857 GHz frequency channel maps from the Planck survey. This map shows an obvious galaxy cluster tSZ signal that is well matched with blindly detected clusters in the Planck SZ catalogue. To characterize the signal in the tSZ map we have computed its angular power spectrum. At large angular scales (&ell; < 60), the major foreground contaminant is the diffuse thermal dust emission. At small angular scales (&ell; > 500) the clustered cosmic infrared background and residual point sources are the major contaminants. These foregrounds are carefully modelled and subtracted. We thus measure the tSZ power spectrum over angular scales 0.17° ≲ θ ≲ 3.0° that were previously unexplored. The measured tSZ power spectrum is consistent with that expected from the Planck catalogue of SZ sources, with clear evidence of additional signal from unresolved clusters and, potentially, diffuse warm baryons. Marginalized band-powers of the Planck tSZ power spectrum and the best-fit model are given. The non-Gaussianity of the Compton parameter map is further characterized by computing its 1D probability distribution function and its bispectrum. The measured tSZ power spectrum and high order statistics are used to place constraints on σ 8 .

79 ASTRONOMY AND ASTROPHYSICS↗

Nonlinear dynamics of toroidal Alfvén eigenmodes driven by energetic particles

A kinetic simulation code based on a reduced model is developed to study dynamic evolutions of a single toroidicity-induced shear Alfvén eigenmode driven by energetic particles. For zero background damping, it is found that the wave amplitude in nonlinear phase can either saturate for weak energetic particle drives or slowly increase for strong drives. This slow nonlinear growth in strong drive cases is found to be associated with broadening and overlapping of resonances between the wave and trapped particles. For the near-marginal-stability case with a large background damping, the mode nonlinear evolution exhibits strong upward and downward frequency chirping in multiple branches. A hole/clump formation is observed clearly in the corresponding evolution of energetic particle distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing Storage Operation for a Probabilistic Locational Marginal Pricing Forecast: Preprint

This paper explores the applicability of using dynamic programing (DP) and approximate dynamic programming (ADP) based methods for optimal dispatch of utility scale energy storage systems (ESS). In this study, the effectiveness of these approaches have been tested using the IEEE 13 node test feeder with distributed photovoltaics (PVs) and a utility scale storage system. In this work, a co-simulation based approach has been used to setup the experiment to be able to implement detailed ESS and network models. The results obtained from DP/ADP runs have been compared with three other control strategies both myopic and intelligent. Simulations results show that DP/ADP algorithms are a good candidate for optimal EES dispatch in terms of both solution quality and execution time.

25 ENERGY STORAGE↗

Smart Meters Enabling Voltage Monitoring and Control Functionalities: The Last-Mile Voltage Stability Issue

It is a demanding yet challenging task to design the next generation of smart meters. This work investigates the new voltage monitoring and control function for the next-generation smart meters, and identifies its added values for power system voltage stability issues. In terms of voltage monitoring, the risk benefit analysis for adding voltage magnitudes to smart meter measurements is presented, and the risk mitigation strategies along with the co-simulation validation via GridLAB-D and NS-3 are proposed, all providing insight into the new function evaluation. In terms of voltage control, a new voltage stability control scheme is developed, which uses voltage measurements from smart meters and utilizes the observability and controllability of distributed energy resources and controllable loads. Different from traditional voltage control schemes focusing on voltage regulation and power quality monitoring from the utility perspective, the proposed control scheme can achieve the maximum real power transfer margin at the end user side, enabling the voltage stability issues being solved at the grid edge, i.e. the last-mile segment. It is the first work that considers voltage monitoring and control collectively for smart meter investment. It can help power engineering community supplement smart meter applications and shape the next-generation smart meters.

42 ENGINEERING↗

DEM simulation of the compression of crushable sand: does the initial particle shape matter?

Advances in DEM modeling, combined with high-resolution X-ray tomography, opened the way for computer models based on virtual replicas of the particles which preserve nearly all facets of their geometry. This leads to simulation advantages, but also high computational costs. Here we tackle a question stemming from this trend: how accurate should particle models be to ensure accuracy? We address this question for the case of the compression of crushable sand. LS-DEM was used to generate three models of Ottawa sand (exact replicas, ellipsoids, and spheres) from digital images of its grains. Compression-induced crushing was simulated for all sets by tracking evolving size and shape distribution. The results confirm that exact replicas provide the closest match of the measurements. However, intermediate degrees of rendering (e.g. ellipsoids preserving volume and aspect ratio of the real grains) led to satisfactory results only marginally different from those of exact replicas. In conclusion, these findings provide an example of the protocols that may be followed to identify the optimal degree of particle approximation which should be regarded as mandatory to achieve a conscious, sustainable use of computational resources.

58 GEOSCIENCES↗

Time-varying value of electric energy efficiency

Electric energy efficiency resources save energy and may reduce peak demand. Historically, quantification of energy efficiency benefits has largely focused on the economic value of energy savings during the first year and lifetime of the installed measures. Due in part to the lack of publicly available research on end-use load shapes (i.e., the hourly or seasonal timing of electricity savings) and energy savings shapes, consideration of the impact of energy efficiency on peak demand reduction (i.e., capacity savings) has been more limited. End-use load research and the hourly valuation of efficiency savings are used for a variety of electricity planning functions, including load forecasting, demand-side management and evaluation, capacity and demand response planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service. This study reviews existing literature on the time-varying value of energy efficiency savings, provides examples in four geographically diverse locations of how consideration of the time-varying value of efficiency savings impacts the calculation of power system benefits, and identifies future research needs to enhance the consideration of the time-varying value of energy efficiency in cost-effectiveness screening analysis. Findings from this study include: -The time-varying value of individual energy efficiency measures varies across the locations studied because of the physical and operational characteristics of the individual utility system (e.g., summer or winter peaking, load factor, reserve margin) as well as the time periods during which savings from measures occur. -Across the four locations studied, some of the largest capacity benefits from energy efficiency are derived from the deferral of transmission and distribution system infrastructure upgrades. However, the deferred cost of such upgrades also exhibited the greatest range in value of all the components of avoided costs across the locations studied. -Of the five energy efficiency measures studied, those targeting residential air conditioning in summer-peaking electric systems have the most significant added value when the total time-varying value is considered. -The increased use of rooftop solar systems, storage, and demand response, and the addition of electric vehicles and other major new electricity-consuming end uses are anticipated to significantly alter the load shape of many utility systems in the future. Data used to estimate the impact of energy efficiency measures on electric system peak demands will need to be updated periodically to accurately reflect the value of savings as system load shapes change. -Publicly available components of electric system costs avoided through energy efficiency are not uniform across states and utilities. Inclusion or exclusion of these components and differences in their value affect estimates of the time-varying value of energy efficiency. -Publicly available data on end-use load and energy savings shapes are limited, are concentrated regionally, and should be expanded.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geometric Tail Approximation for Reliability and Survivability

A common problem in developing high-reliability systems is estimating the reliability for a population of components that cannot be 100% tested. The radiation survivability of a population of components is often estimated by testing a very small sample to some multiple of the required specification level, known as an overtest. Given a successful test with a sufficient overtest margin, the population of components is assumed to have the required survivability or radiation reliability. However, no mathematical justification for such claims has been crafted without making aggressive assumptions regarding the statistics of the unknown distribution. Here we illustrate a new approach that leverages geometric bounding arguments founded on relatively modest distribution assumptions to produce conservative estimates of component reliability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flattening the Radial Temperature Profile across the Transformational Challenge Reactor Core

The Transformational Challenge Reactor (TCR) program is demonstrating an agile development approach to advanced nuclear reactor design, which has traditionally utilized a linear design process. In leveraging artificial intelligence, additive manufacturing, advanced materials, and cutting-edge modeling and simulation, the TCR program aims to minimize the high cost and lengthy deployment timelines now standard in the nuclear industry. Within a relatively short period of time, a robust and mature advanced gas-cooled reactor was iteratively designed under the TCR program, using these cutting-edge technologies. The TCR is a 3 MWt gas-cooled microreactor fueled with uranium nitride (UN) tristructural isotropic (TRISO) fuel particles. Though manufactured via traditional means, these UN TRISO particles are loaded into additively manufactured silicon carbide (SiC) cans [4]. Once loaded with TRISO particles, the SiC cans are densified using a chemical vapor infiltration process. The additively manufactured SiC enables significantly more freedom in the design of the fuel form than could ever be achieved using traditionally manufactured SiC. The helium coolant, pressurized to 5 MPa, enters the core at 300°C and nominally exits it at 500°C. Typically, the most thermally limiting components in any reactor design are the fuel assemblies in the core center. To provide a wide thermal margin in these central fuel assemblies, the flow may be biased toward the center of the core to more effectively cool these fuel assemblies with more power deposition and flatten the core’s radial temperature distribution. An analytical fluid model of the TCR core was developed to explore methods for biasing the flow away from the cooler outer fuel assemblies and towards the hotter inner ones. Higher-fidelity models developed in STAR-CCM+ 2020.3.1, a computational fluid dynamics code, were then utilized to verify the analytical model’s findings.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tax Credits for Clean Electricity: The Distributional Impacts of Supply-Push Policies in the Power Sector

We evaluate distributional and efficiency consequences of the bulk power clean electricity tax credits authorized by the 2022 Inflation Reduction Act. To do so, we link detailed electricity capacity expansion, computable general equilibrium, microsimulation, and air pollution models to estimate economic welfare and health incidence across demographic groups. We evaluate trade-offs between policy efficiency and income progressivity by comparing the tax credits to cap-and-trade policies. The tax credits encourage increased clean electricity investment, resulting in a reallocation of capital from elsewhere in the economy, higher prices for capital and other goods, lower power prices, and lower emissions. The tax credits yield progressive outcomes for economic welfare at the expense of efficiency while all modeled policies demonstrate progressivity in health impacts. The health benefits, absent climate benefits, exceed total policy costs and provide greater benefits for low-income and historically marginalized households given coincidence of household locations and emissions exposure intensity.

distributional impacts↗

Full core LOCA analysis for BWR/6 - Methodology and first results

As part of collaboration between the Paul Scherrer Institute (PSI) and the Swiss regulator ENSI, a study aimed at core-wide estimates of the fuel rod behaviour during large-break loss-of-coolant-accidents (LB-LOCA) in BWR/6 plants was recently conducted on the basis of a Swiss reactor. To perform such full core LOCA analysis, a methodology consisting of a multi-physics sequence of interfaced best-estimate models and codes was established: CASMO-4E/SIMULATE-3 (C4/S3) for the core modelling, TRACE for the plant system analysis and FALCON for the fuel thermomechanical calculations during base irradiation (BI) as well as for the transient analyses (TA). As starting point, reference C4/S3 models validated for all operated cycles of the given plant were used to select as situation target, a recent cycle representative of modern BWR core loadings and fuel assembly designs. Based on the selected C4/S3 cycle model, PSI in-house computational modules were developed or updated in order to set up the TRACE full core model with regards to assembly geometries, fuel rods thermophysical properties and initial 3-D power distributions. Also, an interface to FALCON BI models was established for the transfer of the irradiation history, including primarily linear heat generation rates (LHGR), for an equivalent fuel pin. For each assembly, the power of the equivalent pin is defined with the maximum power of all pins at each axial position. However, in order to reduce the computational time of the fuel performance analyses, the whole core was subdivided into groups of assemblies, each represented by the most powerful assembly within the group. On this basis, the FALCON BI analyses were conducted with coupling to the PSI advanced model for gas release and swelling (GRWS-A) and an interface was developed to transfer the calculated fuel rod characteristics at end of irradiation to initialize the core fuel rods heat structures in the TRACE model. Subsequently, double-ended recirculation line rupture scenarios at hot-full-power (HFP) conditions were investigated with TRACE in order to determine a conservative transient case as function of cycle burnup, single failure criterion and availability of safety systems. For the most conservative case of this study, an interface was set-up to transfer the TRACE results as boundary conditions to the FALCON TA models, including thus primarily time and axial distributions of the clad outer temperatures. As final step, the FALCON TA were conducted for the representative assemblies in order to infer core-wide estimates of the fuel rod behaviour with specific focus on equivalent cladding reacted levels, hoop strains as well as margins to failure criteria. The objective of this paper is to present this methodology along with the obtained first results. Regarding the latter, it is found that principally, even for the most conservative LOCA scenario of this study, the clad temperature excursion remains mild enough at all core locations such that no significant rod ballooning and no cladding failure is predicted, something in line with corresponding analyses conducted earlier for BWR/4 plants. (authors)

42 ENGINEERING↗