Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Lidar system analysis for measurement of atmospheric species

Several important aspects of lidar are discussed, which pertain to a system analysis of the applicability of certain types of lidar to specific measurement objectives. The differential absorption lidar (DIAL) technique is emphasized. A brief treatment of the DIAL technique is followed by a discussion of the comparison of DIAL with other lidar measurement techniques. Sensitivity expressions are presented for DIAL with either direct or coherent (heterodyne) detection systems. A treatment of the fundamental similarities and differences in using the UV and IR spectral regions for species measurements, such as backscattering properties, spectral characteristics of the absorbing species, and factors relevant to the optimization of the DIAL measurement accuracy, is also included. Finally, results obtained from an existing ground-based DIAL system used to measure water vapor profiles are briefly discussed.

Menzies, R. T.↗

Comparisons of Impedance Prediction Models for Perforate-over-Honeycomb Liners

A large dataset is used to evaluate the efficacy of multiple impedance prediction models for perforate-over-honeycomb liners. Two-factorial analysis is used to explore the relative importance of the key parameters used in these models. Tests are conducted in the NASALangley Normal Incidence Tube and Grazing Flow Impedance Tube with over eighty perforate facesheets at multiple source sound pressure levels, Mach numbers and frequencies. Each prediction model is then compared with this dataset to determine how well each method predicts the measured data. Finally, an optimizer is used to further improve the ability of one of these models to reproduce the measured results.

acoustic↗

Comparisons of Impedance Prediction Models for Perforate-over-Honeycomb Liners

A large dataset is used to evaluate the efficacy of multiple impedance prediction models for perforate-over-honeycomb liners. Two-factorial analysis is used to explore the relative importance of the key parameters used in these models. Tests are conducted in the NASALangley Normal Incidence Tube and Grazing Flow Impedance Tube with over eighty perforate facesheets at multiple source sound pressure levels, Mach numbers and frequencies. Each prediction model is then compared with this dataset to determine how well each method predicts the measured data. Finally, an optimizer is used to further improve the ability of one of these models to reproduce the measured results.

acoustic↗

Data-Driven Optimization for the Design and Control of Large-Scale Systems (LDRD Final Report)

Engineering decisions are often formulated as optimization problems such as the optimal design or control of physical systems. In these applications, the resulting optimization problems are constrained by large-scale simulations involving systems of partial differential equations (PDEs), ordinary differential equations (ODEs), and differential algebraic equations (DAEs). In addition, critical components of these systems are fraught with uncertainty, including unverifiable modeling assumptions, unknown boundary and initial conditions, and uncertain coefficients. Typically, these components are estimated using noisy and incomplete data from a variety of sources (e.g., physical experiments). The lack of knowledge of the true underlying probabilistic characterization of model inputs motivates the need for optimal solutions that are robust to this uncertainty. In this report, we introduce a framework for handling "distributional" uncertainties in the context of simulation-based optimization. This includes a novel measure discretization technique that will lead to an adaptive optimization algorithm tailored to exploit the structures inherent to simulation- based optimization.

42 ENGINEERING↗

SHIVA: Spaceflight Holography Investigation in a Virtual Apparatus

SHIVA, a NASA spaceflight program, will exploit a unique, holography-based, diagnostics tool to test and apply a new, more general analytical solution to a fundamental equation of motion. The equation describes particle dynamics in fluids in a microgravity environment, and our solution represents the first analytical solution of it. When gravity is removed the equation becomes much more complex and had been solved previously only by numerical means. After our analytical solution has been validated it will be used as a tool for making additional measurements of the gravity environment. Our experiment will be optimized for testing the model, measuring g, g-jitter, and other microgravity phenomena. We will also collect data for which no current theory exists, This paper describes ground experiments and analysis that have been conducted by the investigator team to support the flight experiment.

Trolinger, James D.↗

Solar Array (Radiated/Non-Radiated): Materials Characterization and Cryogenic Thermal Cycling Qualification for the Planned Europa Clipper Mission (ECM)

Two special instruments were custom built for our critical study and manufactured and employed to test the SA materials of interest to cryogenic temperature conditions. We have procured custom manufactured two independent systems such as Thermo -Mechanical Analyzer (TMA) with Three Point Bend Probe (TPBP) module and Dilatometer. TMA can be used to measure Young’ s modulus or elastic modulus (e -modulus). Dilatometer can be used to measure Co -efficient of Thermal Expansion (CTE). We have optimized the materials configuration to measure physical properties of radiated and non -radiated materials for CTE and e -modulus, which will be useful to assess materials and processes reliability for cryogenic temperature applications. We have successfully implemented for some materials that are of interest to solar panels for the planned ECM project to measure CTE and Young's modulus. Also a separate study was undertaken to thermal cycle qualify SAs for ECM project. One can do thermal cycling to temperatures of 50 K and 133 K using liquid Helium (Lq He). This is in reality exorbitantly too expensive and is also inefficient. Furthermore, this is not technically controllable test to 133 K and 50 K temperatures. This is also too expensive to accomplish. Therefore, a vacuum set -up was made along with a cryostat successfully. This is a closed loop system where we do not lose the Helium gas. We were able to get to 35 K for a given test coupon size. These temperatures are lower than what we would intend to qualify the solar array technologies. This will allow to have some margin at cold temperatures. We successfully completed the qualification of solar array technologies down to 50 K temperatures. This is the first time we are reporting this accomplishment. In this paper, we will present the solar array materials properties for cryogenic temperatures down to 20 K temperatures and the thermal cycling qualification test results from 133 K to 50 K for three times the mission life of 120 thermal cycles to meet JPL Design.

Ramesham, Rajeshuni↗

Assumed non-persistent environmental chemicals in human adipose tissue; matrix stability and correlation with levels measured in urine and serum

The aim of this study was to (1) optimize a method for the measurement of parabens and phenols in adipose tissue, (2) evaluate the stability of chemical residues in adipose tissue samples, and (3) study correlations of these compounds in urine, serum, and adipose tissue. Samples were obtained from adults undergoing trauma surgery. Nine phenols and seven parabens were determined by isotope diluted TurboFlow-LC-MS/MS. The analytical method showed good accuracy and precision. Limits of detection (LOD) for parabens and phenols ranged from 0.05 to 1.83 ng/g tissue. Good recovery rates were found, even when biological samples remained defrosted up to 24 h. Benzophenone-3 (BP-3; range of values: 70% of adipose tissue samples, while bisphenol-A (BPA; 40% of adipose tissue samples. In general, levels were similar between adipose tissue and serum, while a correlation between adipose tissue and urine was only found for BP-3. In conclusion, adipose tissue samples in this study were found to contain environmental chemicals considered to be non-persistent, whose levels were weakly or not at all correlated with the urine burden. Therefore, adipose tissue may potentially provide additional information to that obtained from other biological matrices. Further investigations are warranted to explore whether adipose tissue might be a suitable matrix for assessment of the consequences for human health of mid/long-term exposure to these chemicals. - Highlights: • We analyzed levels of endocrine disruptors in adipose tissue, serum and urine. • We found BPA, TCS, BP-3, 2-PP and MeP in >40% of the adipose tissue samples. • Adipose tissue levels of npEDCs did not correlate with those in urine or serum. • Adipose tissue levels may have a different biological meaning.

54 ENVIRONMENTAL SCIENCES↗

Machine Learning-Based Technique for Automated Sensor Characterization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert s time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Zepeda, Cuevas [Chicago U., KICP]↗

Automating Sensor Characterization with Bayesian Optimization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert's time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Cuevas-Zepeda, Julian [Chicago U., KICP; Chicago U↗