Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

High-Pressure Neutron Diffraction Study on H-D Isotope Effects in Brucite

A neutron powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 GPa, using a Paris-Edinburgh high-pressure cell at the WAND instrument of ORNL High Flux Isotope Reactor. The two materials were synthesized by the same method and companion measurements of neutron diffraction were conducted under the same conditions. Our refinement results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decreases only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg(OD)2 is shorter and decreases more rapidly than that of Mg(OH)2 with increasing pressure. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of normal brucite, which were fitted to third-order Birch-Murnaghan equation: K0=41.46 0.52 and 39.04 0.30 GPa for Mg(OH)2 and Mg(OD)2, respectively with a fixed K0 value of 10. Our results suggest that H-D substitution of brucite and other hydrous minerals with H-bonding likely influences their structural and dynamic properties under pressure, including the position of hydrogen atoms. The measured effect of H-D substitution on the unit-cell volume also demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

08 HYDROGEN↗

Scalable quantum processor noise characterization

Measurement fidelity matrices (MFMs) (also called error kernels) are a natural way to characterize state preparation and measurement errors in near-term quantum hardware. They can be employed in post processing to mitigate errors and substantially increase the effective accuracy of quantum hardware. However, the feasibility of using MFMs is currently limited as the experimental cost of determining the MFM for a device grows exponentially with the number of qubits. In this work we present a scalable way to construct approximate MFMs for many-qubit devices based on cumulant expansions. Our method can also be used to characterize various types of correlation error.

Hamilton, Kathleen↗

Two-dimensional stitching interferometry for self-calibration of high-order additive systematic errors

Stitching interferometry is performed by collecting interferometric data from overlapped sub-apertures and stitching these data together to provide a full surface map. The propagation of the systematic error in the measured subset data is one of the main error sources in stitching interferometry for accurate reconstruction of the surface topography. In this work, we propose, using the redundancy of the captured subset data, two types of two-dimensional (2D) self-calibration stitching algorithms to overcome this issue by in situ estimating the repeatable high-order additive systematic errors, especially for the application of measuring X-ray mirrors. The first algorithm, called CS short for “Calibrate, and then Stitch”, calibrates the high-order terms of the reference by minimizing the de-tilted discrepancies of the overlapped subsets and then stitches the reference-subtracted subsets. The second algorithm, called SC short for “Stitch, and then Calibrate”, stitches a temporarily result and then calibrates the reference from the de-tilted discrepancies of the measured subsets and the temporarily stitched result. In the implementation of 2D scans in $x$- and y -directions, step randomization is introduced to generate nonuniformly spaced subsets which can diminish the periodic stitching errors commonly observed in evenly spaced subsets. The regularization on low-order terms enables a highly flexible option to add the curvature and twist acquired by another system. Both numerical simulations and experiments are carried out to verify the proposed method. All the results indicate that 2D high-order repeatable additive systematic errors can be retrieved from the 2D redundant overlapped data in stitching interferometry.

42 ENGINEERING↗

Absolute energy calibration for relativistic electron beams with pointing instability from a laser-plasma accelerator

The pointing instability of energetic electron beams generated from a laser-driven accelerator can cause a serious error in measuring the electron spectrum with a magnetic spectrometer. In order to determine a correct electron spectrum, the pointing angle of an electron beam incident on the spectrometer should be exactly defined. Here, we present a method for absolutely calibrating the electron spectrum by monitoring the pointing angle using a scintillating screen installed in front of a permanent dipole magnet. The ambiguous electron energy due to the pointing instability is corrected by the numerical and analytical calculations based on the relativistic equation of electron motion. It is also possible to estimate the energy spread of the electron beam and determine the energy resolution of the spectrometer using the beam divergence angle that is simultaneously measured on the screen. The calibration method with direct measurement of the spatial profile of an incident electron beam has a simple experimental layout and presents the full range of spatial and spectral information of the electron beams with energies of multi-hundred MeV level, despite the limited energy resolution of the simple electron spectrometer.

43 PARTICLE ACCELERATORS↗

Ab initio wavenumber accurate spectroscopy : {sup 1}CH{sub 2} and HCN vibrational levels on automatically generated IMLS potential energy surfaces.

We report here calculated J = 0 vibrational frequencies for {sup 1}CH{sub 2} and HCN with root-mean-square error relative to available measurements of 2.0 cm{sup -1} and 3.2 cm{sup -1}, respectively. These results are obtained with DVR calculations with a dense grid on ab initio potential energy surfaces (PESs). The ab initio electronic structure calculations employed are Davidson-corrected MRCI calculations with double-, triple-, and quadruple-{zeta} basis sets extrapolated to the complete basis set (CBS) limit. In the {sup 1}CH{sub 2} case, Full CI tests of the Davidson correction at small basis set levels lead to a scaling of the correction with the bend angle that can be profitably applied at the CBS limit. Core-valence corrections are added derived from CCSD(T) calculations with and without frozen cores. Relativistic and non-Born-Oppenheimer corrections are available for HCN and were applied. CBS limit CCSD(T) and CASPT2 calculations with the same basis sets were also tried for HCN. The CCSD(T) results are noticeably less accurate than the MRCI results while the CASPT2 results are much poorer. The PESs were generated automatically using the local interpolative moving least-squares method (L-IMLS). A general triatomic code is described where the L-IMLS method is interfaced with several common electronic structure packages. All PESs were computed with this code running in parallel on eight processors. The L-IMLS method provides global and local fitting error measures important in automatically growing the PES from initial ab initio seed points. The reliability of this approach was tested for {sup 1}CH{sub 2} by comparing DVR-calculated vibrational levels on an L-IMLS ab initio surface with levels generated by an explicit ab initio calculation at each DVR grid point. For all levels ({approx}200) below 20000 cm{sup -1}, the mean unsigned difference between the levels of these two calculations was 0.1 cm{sup -1}, consistent with the L-IMLS estimated mean unsigned fitting error of 0.3 cm{sup -1}. All L-IMLS PESs used in this work have comparable mean unsigned fitting errors, implying that fitting errors have a negligible role in the final errors of the computed vibrational levels with experiment. Less than 500 ab initio calculations of the energy and gradients are required to achieve this level of accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Home Mobility Frequency and Stability in Older Adults Living Alone With or Without MCI: Introduction of New Metrics

Background: Older adults spend a considerable amount of time inside their residences; however, most research investigates out-of-home mobility and its health correlates. We measured indoor mobility using room-to-room transitions, tested their psychometric properties, and correlated indoor mobility with cognitive and functional status. Materials and Methods: Community-dwelling older adults living alone ( n = 139; age = 78.1 ± 8.6 years) from the Oregon Center for Aging & Technology (ORCATECH) and Minority Aging Research Study (MARS) were included in the study. Two indoor mobility features were developed using non-parametric parameters (frequency; stability): Indoor mobility frequency (room-to-room transitions/day) was detected using passive infrared (PIR) motion sensors fixed on the walls in four geographic locations (bathroom; bedroom; kitchen; living room) and using door contact sensors attached to the egress door in the entrance. Indoor mobility stability was estimated by variances of number of room-to-room transitions over a week. Test-retest reliability (Intra-class coefficient, ICC) and the minimal clinically important difference (MCID) defined as the standard error of measurement (SEM) were generated. Generalized estimating equations models related mobility features with mild cognitive impairment (MCI) and functional status (gait speed). Results: An average of 206 days (±127) of sensor data were analyzed per individual. Indoor mobility frequency and stability showed good to excellent test-retest reliability (ICCs = 0.91[0.88–0.94]; 0.59[0.48–0.70]). The MCIDs of mobility frequency and mobility stability were 18 and 0.09, respectively. On average, a higher indoor mobility frequency was associated with faster gait speed (β = 0.53, p = 0.04), suggesting an increase of 5.3 room-to-room transitions per day was associated with an increase of 10 cm/s gait speed. A decrease in mobility stability was associated with MCI (β = −0.04, p = 0.03). Discussion: Mobility frequency and stability in the home are clinically meaningful and reliable features. Pervasive-sensing systems deployed in homes can objectively reveal cognitive and functional status in older adults who live alone.

Wu, Chao-Yi↗

Chirped-probe-pulse femtosecond CARS thermometry in turbulent spray flames

This paper presents temperature measurements in turbulent dilute and dense spray flames using single-laser-shot chirped-probe-pulse femtosecond coherent anti-Stokes Raman spectroscopy (CPP-fs-CARS). This ultrafast technique, with a repetition rate of 5 kHz, is applied to the piloted Sydney Needle Spray Burner (SYNSBURN TM ). The burner system features air-blast atomization of liquid injected from a needle that can be translated within a co-flowing air stream. The pilot-stabilized spray flames can range between the two extremes of dense and dilute by physically translating the needle tip relative to the burner's exit plane. The CPP-fs-CARS set-up has achieved integration times of 3 picoseconds (ps) as well as spatial resolution of approximately 800 µm along beam propagation and 60 µm in the transverse dimension. Brief details of the technique, calibration, correction of interferences, and spectral fitting processes are presented along with estimates of the associated error. The measurements are compared against well-established, line Raman–Rayleigh data for temperature collected in a turbulent CH 4 /air jet diffusion flame, which is largely non-sooting. At peak gaseous flame temperatures of up to 2512 K, the relative accuracy and precision were 2.8% and ±3.4%, respectively. Measurements in turbulent spray flames are shown after applying the relevant corrections based on non-resonant background (NRB) behavior and camera saturation effects on the shape of the CARS signal spectrum. Preliminary mapping of the temperature fields demonstrates the wealth of information available in this dataset which will provide insights into the spatio-temporal structure of spray flames once relevant statistical analysis is applied.

42 ENGINEERING↗

DESI DR2 Galaxy luminosity functions

We present galaxy luminosity functions (LFs) for the Dark Energy Spectroscopic Instrument (DESI) DR2 Bright Galaxy Survey (BGS) in the g, r, z, and $w1$ bands over $0.002\lt z\lt 0.6$. Our analysis uses updated k-corrections and evolutionary corrections, including new polynomial kcorrection fits derived from BGS Year 1 data that supersede earlier GAMA-based prescriptions. Exploiting the statistical power of DESI, we measure LFs to very faint magnitudes, reaching $^{0.1}M_r-5\log h\sim -10$. Independent measurements from the North and South survey regions show excellent agreement around the LF knee, but the very small statistical uncertainties reveal that simple analytic forms fail to capture the full LF shape. The bright end departs from a pure exponential decline, while the faint end exhibits complex, non-powerlaw behaviour, including a pronounced upturn at $^{0.1}M_r-5\log h\gtrsim -15$, which is stronger for red galaxies than for blue. We show that our LFs are largely complete for galaxies with surface brightness $\mu _{50}\lt 25$, and that an apparent steepening fainter than $-13$ is driven primarily by local overdensity and fragmentation of large galaxies. A systematic North–South offset at the brightest magnitudes is traced to red galaxies and may reflect shallower North photometry underestimating extended earlytype profiles, although this remains inconclusive. We therefore also provide LFs based on model Petrosian magnitudes. Redshift splitting reveals small but significant residuals, indicating limitations of a simple global evolutionary model. Using the redshift limits of J. Loveday et al. (2012), we find excellent agreement with GAMA, with substantially reduced statistical errors. These measurements provide a precise reference for studies of environmental and population-dependent LFs and for testing galaxy formation models.

79 ASTRONOMY AND ASTROPHYSICS↗

LCLS X-ray mirror measurements using a large aperture visible light interferometer

Synchrotron or FEL X-ray mirrors are required to deliver an X-ray beam from its source to an experiment location, without contributing significantly to wave front distortion. Accurate mirror figure measurements are required prior to installation to meet this intent. This paper describes how a 300 mm aperture phasing interferometer was calibrated to <1 nm absolute accuracy and used to mount and measure 450 mm long flats for the Linear Coherent Light Source (LCLS) at Stanford Linear Accelerator Center. Measuring focus mirrors with an interferometer requires additional calibration, because high fringe density introduces systematic errors from the interferometer's imaging optics. This paper describes how these errors can be measured and corrected. The calibration approaches described here apply equally well to interferometers larger than 300 mm aperture, which are becoming more common in optics laboratories. The objective of this effort was to install LCLS flats with < 10 nm of spherical curvature, and < 2 nm rms a-sphere. The objective was met by measuring the mirrors after fabrication, coating and mounting, using a 300 mm aperture phasing interferometer calibrated to an accuracy < 1 nm. The key to calibrating the interferometer accurately was to sample the error using independent geometries that are available. The results of those measurements helped identify and reduce calibration error sources. The approach used to measure flats applies equally well to focus mirrors, provided an additional calibration is performed to measure the error introduced by fringe density. This calibration has been performed on the 300 mm aperture interferometer, and the measurement correction was evaluated for a typical focus mirror. The 300 mm aperture limitation requires stitching figure measurements together for many X-ray mirrors of interest, introducing another possible error source. Stitching is eliminated by applying the calibrations described above to larger aperture instruments. The authors are presently extending this work to a 600 mm instrument. Instruments with 900 mm aperture are now becoming available, which would accommodate the largest mirrors of interest.

43 PARTICLE ACCELERATORS↗

Battery state of health monitoring by estimation of the number of cyclable Li-ions

Herein this paper introduces a method to monitor battery state of health (SOH) by estimating the number of cyclable Li-ions, a health-relevant electrochemical variable. SOH monitoring is critical to battery management in balancing the trade-off between maximizing system performance and minimizing battery degradation. The decrease of cyclable Li-ions indicates the effect on the SOH of degradation mechanisms that consume cyclable Li-ions. The unavailability of the number of cyclable Li-ions through non-invasive measurements makes its estimation necessary for in-situ SOH monitoring. In this paper, the extended Kalman filter (EKF) is used to estimate the number of cyclable Li-ions as an unknown battery parameter. The single particle model (SPM), a simplified battery electrochemical model, is used as the model in the EKF to achieve a computational complexity suitable for on-line estimation. Simulations are performed under typical electric vehicle current trajectories using an example parameter set for a hybrid-electric-vehicle battery. In the simulations, the battery is represented by the Doyle–Fuller–Newman (DFN) model, an electrochemical model with higher fidelity than the SPM. To comply with the practice, instead of using the same parameters as the DFN model in the SPM, parameterization of the SPM is performed before estimation of the number of cyclable Li-ions. The simulations show high estimation accuracy of the number of cyclable Li-ions using the EKF, even with the structural and parametric differences between the DFN model and the SPM, under both the ideal conditions and various non-ideal conditions (i.e., SOC estimation error, additional modeling error, and measurement noise).

25 ENERGY STORAGE↗

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pseudospectral calculation of the wave function of helium and the negative hydrogen ion

We study the numerical solution of the nonrelativistic Schroedinger equation for two-electron atoms in ground and excited S states using pseudospectral (PS) methods of calculation. The calculation achieves convergence rates for the energy, Cauchy error in the wave function, and variance in local energy that are exponentially fast for all practical purposes. The method requires three separate subdomains to handle the wave function's cusplike behavior near the two-particle coalescences. The use of three subdomains is essential to maintaining exponential convergence and is more computationally efficient than a single subdomain. A comparison of several different treatments of the cusps suggests that the simplest prescription is sufficient. We investigate two alternate methods for handling the semi-infinite domain, one which involves a sequence of truncated versions of the domain and the other which employs an algebraic mapping of the semi-infinite domain to a finite one and imposes no explicit cutoffs on the wave function. The latter prescription proves superior. For many purposes it proves unnecessary to handle the three-particle coalescence in a special way. The presence of logarithmic terms in the exact solution is expected to limit the convergence to being nonexponential but the only clear evidence of that is the rate of convergence of derivatives near the three-particle coalescence point. Higher resolution than achieved in this work will ultimately be needed to see its limiting effect on other measures of error. As developed and applied here the PS method has many virtues: no explicit assumptions need be made about the asymptotic behavior of the wave function near cusps or at large distances, the local energy (H{psi}/{psi}) is exactly equal to the calculated global energy at all collocation points, local errors go down everywhere with increasing resolution, the effective basis using Chebyshev polynomials is complete and simple, and the method is easily extensible to other bound states. As the number of collocation points grows, the method achieves exponential convergence up to the resolution tested. This study serves as a proof-of-principle of the method for more general two- and possibly three-electron applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the rate constants for the radical-radical reactions NH{sub 2}(X{sup 2}B{sub 1}) + NH(X{sup 3}{Sigma}{sup -}) and NH{sub 2}(X{sup 2}B{sub 1}) + H({sup 2}S{sub u}) at 293 K.

The rate constant for the reactions NH{sub 2}({sub x}{sup 2}B{sub 1}) + NH(X{sup 3}{Sigma}{sup -}) and NH{sub 2}({sub x}{sup 2}B{sub 1}) + H({sup 2}S) were measured over a pressure range from 2 to 10 Torr in CF{sub 4}, or Ar gases at 293 {+-} 2 K. The radicals were produced by the 193 nm photolysis of NH{sub 3} dilute in the carrier gas. Both radicals were monitored simultaneously following the photolysis laser pulse using high-resolution time-resolved absorption spectroscopy. The NH{sub 2} radical was monitored using the {sup 1}2{sub 21} {l_arrow} {sup 1}3{sub 31} rotational transition of the (0,7,0){sub A}{sup 2}A{sub 1} {l_arrow} (0,0,0) {sub x}{sup 2}B{sub 1} vibronic band near 675 nm, and the NH radical was monitored using the {sup 1}R{sub 3}(4) rotational transition on the 1?0 vibrational transition near 3084 nm. The data was analyzed using model simulations of the NH{sub 2} and NH temporal concentration profiles. The rate constants for the NH{sub 2} + NH and NH{sub 2} + H reactions were found to be (9.6 {+-} 3.2) x 10{sup -11} and (7.7 {+-} 14) x 10{sup -15} cm{sup 3} molecule{sup -1} s{sup -1}, respectively, where the uncertainty includes an estimate of both systematic and random errors. The measurements were independent of the nature of the diluents, CF{sub 4} or Ar, and total pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

Sizing of irregular particles using a near backscattered laser Doppler system

A near backscattered laser Doppler system was presented to carry out velocity and size distribution measurements for irregular particles in two-phase flows. The technique uses amplitudes of particles Doppler signals to estimate the particle size distribution in a statistical manner. Holve's numerical inversion scheme is employed to unfold the dependence of the scattered signals on both particle trajectory and orientation through the measurement volume. The performance and error level of the technique were simulated, and several parameters including the number of particle samples, the fluctuation of irregular particle response function, inversion algorithms, and types of particle size distribution were extensively investigated. The results show that the size distributions for those irregular particles even with strong fluctuations in response function can be successfully reconstructed with an acceptable error level using a Phillips-Twomey-non-negative least-squares algorithm instead of a non-negative least-squares one. The measurement system was then further experimentally verified with irregular quartz sands. Using inversion matrix obtained from the calibration experiment, the average measurement error for the mixing quartz sands with a size range of 200-560 {mu}m are found to be about 23.3%, which shows the reliability of the technique and the potential for it to be applied to industrial measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Aggregation of Leslie matrix models with application to ten diverse animal species

Some grouping is necessary when constructing a Leslie matrix model because it involves discretizing a continuous process of births and deaths. Here, the level of grouping is determined by the number of age classes and frequency of sampling. It is largely unknown what is lost or gained by using fewer age classes, and I address this question using aggregation theory. I derive an aggregator for a Leslie matrix model using weighted least squares, determine what properties an aggregated matrix inherits from the original matrix, evaluate aggregation error, and measure the influence of aggregation on asymptotic and transient behaviors. To gauge transient dynamics, I employ reactivity of the standardized Leslie matrix. I apply the aggregator to 10 Leslie models developed for animal populations drawn from a diverse set of species. Several properties are inherited by the aggregated matrix: (a) it is a Leslie matrix; (b) it is irreducible whenever the original matrix is irreducible; (c) it is primitive whenever the original matrix is primitive; and (d) its stable population growth rate and stable age distribution are consistent with those of the original matrix if the least squares weights are equal to the original stable age distribution. In the application, depending on the population modeled, when the least squares weights do not follow the stable age distribution, the stable population growth rate of the aggregated matrix may or may not be approximately consistent with that of the original matrix. Transient behavior is lost with high aggregation.

54 ENVIRONMENTAL SCIENCES↗

Electroweak observables in neutrino-electron scattering from a muon storage ring

We investigate the sensitivity of a companion neutrino detector situated in the plane of a high-energy, high-intensity muon storage ring to elastic ν μ and ν e scattering on electrons (EνES). Assuming a muon collider with center-of-mass energies of up to 10 TeV, we report sensitivity to the weak couplings g V and g A up to around 0.05% relative error, and sensitivity to the weak mixing angle in the momentum transfer Q ∈ [10 −2 , 2] GeV range up to around 0.03% relative error. EνES measurements with high-energy muon storage rings allow one to directly interrogate the momentum-transfer regime associated with the NuTeV anomaly. This level of precision allows unique sensitivity to the momentum-dependence of sin 2 θ W . We estimate that with the neutrinos from a E μ = 1.5 TeV (or higher) muon collider, the hypothesis that sin 2 θ W does not “run” can be safely ruled out.

electroweak precision physics↗

Determination of the Thermodynamic Properties of the Cyclohexane + n-Octane + n-Hexadecane Liquid Mixture by the Acoustic Method

The propagation of sound in the ternary cyclohexane + n-octane + n-hexadecane mixture at temperatures of 298–433 K and pressures of 0.1–100.1 MPa was investigated experimentally. The maximum error in measuring the velocity of sound in this mixture was 0.1%. Experimental data on the velocity of sound in such a mixture were obtained for the first time. On the basis of these data, the density, the isobaric expansion coefficient, the isobaric and isochoric heat capacities, and the isothermal compressibility of the indicated ternary mixture of three compositions at a temperature of 298–348 K and a pressure of 0.1–100 MPa and the deviation of the velocity of sound in it from the ideal one were determined. With the use of a number of semiempirical equations, the deviation of the velocity of sound in this mixture from the ideal one was estimated on the basis of the data on the velocity of sound in its pure components and in their binary compounds. A good agreement between the calculation and experimental data has been obtained. A table of the thermodynamic properties of the cyclohexane + n-octane + n-hexadecane mixture is presented.

42 ENGINEERING↗