Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

ON SPECTROPOLARIMETRIC MEASUREMENTS WITH VISIBLE LINES

The ability of new instruments for providing accurate inferences of vector magnetic fields and line-of-sight velocities of the solar plasma depends a great deal on the sensitivity to these physical quantities of the spectral lines chosen to be measured. Recently, doubts have been raised about visible Stokes profiles to provide a clear distinction between weak fields and strong ones filling a small fraction of the observed area. The goal of this paper is to give qualitative and quantitative arguments that help in settling the debate since several instruments that employ visible lines are either operating or planned for the near future. The sensitivity of the Stokes profiles is calculated through the response functions (RFs), for e.g., by Ruiz Cobo and Del Toro Iniesta. Both theoretical and empirical evidences are gathered in favor of the reliability of visible Stokes profiles. The RFs are also used for estimating the uncertainties in the physical quantities due to noise in observations. A useful formula has been derived that takes into account the measurement technique (number of polarization measurements, polarimetric efficiencies, and number of wavelength samples), the model assumptions (number of free parameters and the filling factor), and the radiative transfer (RFs). We conclude that a scenario with a weak magnetic field can reasonably be distinguished with visible lines from another with a strong field but a similar Stokes V amplitude, provided that the Milne-Eddington approximation is good enough to describe the solar atmosphere and the polarization signal is at least 3 or 4 times larger than the typical rms noise of 10{sup -3} I{sub c} reached in the observations.

79 ASTRONOMY AND ASTROPHYSICS↗

CLASH-X: A comparison of lensing and X-ray techniques for measuring the mass profiles of galaxy clusters

We present profiles of temperature, gas mass, and hydrostatic mass estimated from new and archival X-ray observations of CLASH clusters. We compare measurements derived from XMM and Chandra observations with one another and compare both to gravitational lensing mass profiles derived with CLASH Hubble Space Telescope and Subaru Telescope lensing data. Radial profiles of Chandra and XMM measurements of electron density and enclosed gas mass are nearly identical, indicating that differences in hydrostatic masses inferred from X-ray observations arise from differences in gas-temperature measurements. Encouragingly, gas temperatures measured in clusters by XMM and Chandra are consistent with one another at ∼100-200 kpc radii, but XMM temperatures systematically decline relative to Chandra temperatures at larger radii. The angular dependence of the discrepancy suggests that additional investigation on systematics such as the XMM point-spread function correction, vignetting, and off-axis responses is yet required. We present the CLASH-X mass-profile comparisons in the form of cosmology-independent and redshift-independent circular-velocity profiles. We argue that comparisons of circular-velocity profiles are the most robust way to assess mass bias. Ratios of Chandra hydrostatic equilibrium (HSE) mass profiles to CLASH lensing profiles show no obvious radial dependence in the 0.3-0.8 Mpc range. However, the mean mass biases inferred from the weak-lensing (WL) and SaWLens data are different. As an example, the weighted-mean value at 0.5 Mpc is (b) = 0.12 for the WL comparison and (b) = –0.11 for the SaWLens comparison. The ratios of XMM HSE mass profiles to CLASH lensing profiles show a pronounced radial dependence in the 0.3-1.0 Mpc range, with a weighted mean mass bias value rising to (b) ≳ 0.3 at ∼1 Mpc for the WL comparison and (b) ≈ 0.25 for the SaWLens comparison. The enclosed gas mass profiles from both Chandra and XMM rise to a value ≈1/8 times the total-mass profiles inferred from lensing at ≈0.5 Mpc and remain constant outside of that radius, suggesting that M {sub gas} × 8 profiles may be an excellent proxy for total-mass profiles at ≳ 0.5 Mpc in massive galaxy clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory

The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18)eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Cross checks between the two methods demonstrate that results from both analyses are compatible, and that the uncertainties are well understood. The measurements of the aerosol attenuation provided by the two procedures are currently used at the Pierre Auger Observatory to reconstruct air shower data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques to measure quantum criticality in cold atoms

We describe how rescaling experimental data obtained from cold atom density profiles can reveal signatures of quantum criticality. We identify a number of important questions which can be answered by analyzing experimental data in this manner. We show that such experiments can distinguish different universality classes and that the signatures are robust against temperature, noise, and finite system size.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relativistic cyclotron radiation detection of tritium decay electrons as a new technique for measuring the neutrino mass

The shape of the beta-decay energy distribution is sensitive to the mass of the electron neutrino. Attempts to measure the endpoint shape of tritium decay have so far seen no distortion from the zero-mass form, thus placing an upper limit of m{sub {nu}}{sub {beta}}<2.3 eV. Here, we show that a new type of electron energy spectroscopy could improve future measurements of this spectrum and therefore of the neutrino mass. We propose to detect the coherent cyclotron radiation emitted by an energetic electron in a magnetic field. For mildly relativistic electrons, like those in tritium decay, the relativistic shift of the cyclotron frequency allows us to extract the electron energy from the emitted radiation. We present calculations for the energy resolution, noise limits, high-rate measurement capability, and systematic errors expected in such an experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anisotropic thermal transport in bulk hexagonal boron nitride

Hexagonal boron nitride (h-BN) has received great interest in recent years as a wide band-gap analog of graphene-derived systems along with its potential in a wide range of applications, for example, as the dielectric layer for graphene devices. However, the thermal transport properties of h-BN, which can be critical for device reliability and functionality, are little studied both experimentally and theoretically. The primary challenge in the experimental measurements of the anisotropic thermal conductivity of h-BN is that typically the sample size of h-BN single crystals is too small for conventional measurement techniques, as state-of-the-art technologies synthesize h-BN single crystals with lateral sizes only up to 2.5 mm and thicknesses up to 200 μm. Recently developed time-domain thermoreflectance (TDTR) techniques are suitable to measure the anisotropic thermal conductivity of such small samples, as it only requires a small area of 50 × 50 μm 2 for the measurements. Accurate atomistic modeling of thermal transport in bulk h-BN is also challenging due to the highly anisotropic layered structure. Here we conduct an integrated experimental and theoretical study on the anisotropic thermal conductivity of bulk h-BN single crystals over the temperature range of 100–500 K using TDTR measurements with multiple modulation frequencies and a full-scale numerical calculation of the phonon Boltzmann transport equation starting from first principles. Our experimental and numerical results compare favorably for both the in-plane and the through-plane thermal conductivities. We observe unusual temperature dependence and phonon-isotope scattering in the through-plane thermal conductivity of h-BN and elucidate their origins. Here, this article not only provides an important benchmark of the anisotropic thermal conductivity of h-BN, but also develops fundamental insight into the nature of phonon transport in this highly anisotropic layered material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Results From the 6D Diagnostics Test Bench at SNS

This paper presents the method and results for measuring the full six-dimensional phase space of a low energy, high intensity hadron beam. This was done by combining four-dimensional emittance measurement techniques along with dispersion measurement and a beam shape monitor to provide the energy and arrival time components. The measurements were performed on the new Beam Test Facility (BTF) at the Spallation Neutron Source (SNS), a 2.5 MeV functional duplicate of the SNS accelerator front end. The results include a correlation the had not previously been observed.

Cathey, Brandon↗

Progress Summary: 12-Month Compression Set and Load Retention of Thermally Accelerated Aged Siloxane Specimens (Additively Manufactured by the Direct-Ink-Write (DIW) 3D Printing Technique) Was Measured

Motivation: Accelerated aging of polymeric materials is needed to predict their long-term mechanical functionality. Two key metrics used to evaluate their performance are compression set and load retention. A baseline(time=0)mechanical assessment was done prior to initiating the accelerated aging process to acquire initial thickness and load values for future calculation of compression set and load retention.Specimens are beingaged under compressive strain (13%for the current studies) at four different temperatures (25, 40, 55, and 70°C) for at least 1 year; compression set and load retention will be measured at various timepoints. Time-temperature superposition (TTS) will be applied to the isothermal data to obtain long-term predictions. Significance: Compression set is increasing with time and temperature, as expected. The increasing compression set is accompanied by decreasing load retention.The relativelylow compression set indicates the material is performing well.In a previous aging study, the legacy S5370 RTV foam exhibited 40% relative compression set after 12 months at 70°C, which is more than twice that of the DIW material. Progress:Data has been acquired out to the 12-month timepoint. Relative compression set and load retention versus time are shown in Fig. 1.A technical issue with the method of measuring load retention was discovered and previously reported load retention values have been adjusted; the current load retention values are estimates. TTS predictions are shown in Fig. 2.

36 MATERIALS SCIENCE↗

Progress Summary: 17-Month Compression Set and Load Retention of Thermally Accelerated Aged Siloxane Specimens (Additively Manufactured by the Direct-Ink-Write (DIW) 3D Printing Technique) was Measured

Accelerated aging of polymeric materials is needed to predict their long-term mechanical functionality. Two key metrics used to evaluate their performance are compression set and load retention. A baseline (time = 0) mechanical assessment was done prior to initiating the accelerated aging process to acquire initial thickness and load values for future calculation of compression set and load retention.

36 MATERIALS SCIENCE↗

Development of a Novel Electrical Characterization Technique for Measuring Hidden Joint Contacts in Weapons Cavities (LDRD Final Report 218470)

This report summarizes research performed in the context of a REHEDS LDRD project that explores methods for measuring electrical properties of vessel joints. These properties, which include contact points and associated contact resistance, are “hidden” in the sense that they are not apparent from a computer-assisted design (CAD) description or visual inspection. As is demonstrated herein, the impact of this project is the development of electromagnetic near-field scanning capabilities that allow weapon cavity joints to be characterized with high spatial and/or temporal resolution. Such scans provide insight on the hidden electrical properties of the joint, allowing more detailed and accurate models of joints to be developed, and ultimately providing higher fidelity shielding effectiveness (SE) predictions. The capability to perform high-resolution temporal scanning of joints under vibration is also explored, using a multitone probing concept, allowing time-varying properties of joints to be characterized and the associated modulation to SE to be quantified.

42 ENGINEERING↗

A differential emissivity imaging technique for measuring hydrometeor mass and type

Abstract. The Differential Emissivity Imaging Disdrometer (DEID) is a new evaporation-based optical and thermal instrument designed to measure the mass, size, density and type of individual hydrometeors as well as their bulk properties. Hydrometeor spatial dimensions are measured on a heated metal plate using an infrared camera by exploiting the much higher thermal emissivity of water compared with metal. As a melted hydrometeor evaporates, its mass can be directly related to the loss of heat from the hotplate assuming energy conservation across the hydrometeor. The heat loss required to evaporate a hydrometeor is found to be independent of environmental conditions including ambient wind velocity, moisture level and temperature. The difference in heat loss for snow vs. rain for a given mass offers a method for discriminating precipitation phase. The DEID measures hydrometeors at sampling frequencies of up to 1 Hz with masses and effective diameters greater than 1 µg and 200 µm, respectively, determined by the size of the hotplate and the thermal camera specifications. Measurable snow water equivalent (SWE) precipitation rates range from 0.001 to 200 mm h−1, as validated against a standard weighing bucket. Preliminary field experiment measurements of snow and rain from the winters of 2019 and 2020 provided continuous automated measurements of precipitation rate, snow density and visibility. Measured hydrometeor size distributions agree well with canonical results described in the literature.

47 OTHER INSTRUMENTATION↗