Search NASA⌕ Search

SEARCH · Search NASA

Results for “NET ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Energy Storage Requirements for Achieving 50% Solar Photovoltaic Energy Penetration in California

We estimate the storage required to enable PV penetration up to 50% in California (with renewable penetration over 66%), and we quantify the complex relationships among storage, PV penetration, grid flexibility, and PV costs due to increased curtailment. We find that the storage needed depends strongly on the amount of other flexibility resources deployed. With very low-cost PV (three cents per kilowatt-hour) and a highly flexible electric power system, about 19 gigawatts of energy storage could enable 50% PV penetration with a marginal net PV levelized cost of energy (LCOE) comparable to the variable costs of future combined-cycle gas generators under carbon constraints. This system requires extensive use of flexible generation, transmission, demand response, and electrifying one quarter of the vehicle fleet in California with largely optimized charging. A less flexible system, or more expensive PV would require significantly greater amounts of storage. The amount of storage needed to support very large amounts of PV might fit within a least-cost framework driven by declining storage costs and reduced storage-duration needs due to high PV penetration.

14 SOLAR ENERGY↗

DOE Zero Energy Ready Home Case Study: Clifton View Homes, Coupeville, Washington

Ted Clifton, founder of Clifton View Homes, achieved an impressive Home Energy Rating System (HERS) score of 34 (without solar panels) on a two-story home completed in July 2011 that also earned him his first Challenge Home certification from the U.S. Department of Energy (DOE). This home also garnered a 2013 Housing Innovation Award in the "systems builder" category.

Challenge Home↗

Energy Storage Requirements for Achieving 50% Penetration of Solar Photovoltaic Energy in California

We estimate the storage required to enable PV penetration up to 50% in California (with renewable penetration over 66%), and we quantify the complex relationships among storage, PV penetration, grid flexibility, and PV costs due to increased curtailment. We find that the storage needed depends strongly on the amount of other flexibility resources deployed. With very low-cost PV (three cents per kilowatt-hour) and a highly flexible electric power system, about 19 gigawatts of energy storage could enable 50% PV penetration with a marginal net PV levelized cost of energy (LCOE) comparable to the variable costs of future combined-cycle gas generators under carbon constraints. This system requires extensive use of flexible generation, transmission, demand response, and electrifying one quarter of the vehicle fleet in California with largely optimized charging. A less flexible system, or more expensive PV would require significantly greater amounts of storage. The amount of storage needed to support very large amounts of PV might fit within a least-cost framework driven by declining storage costs and reduced storage-duration needs due to high PV penetration.

14 SOLAR ENERGY↗

Prototyping Energy Efficient Thermo-Magnetic & Induction Hardening for Heat Treat & Net Shape Forming Applications

Within this project, Eaton undertook the task of bringing about significant impact with respect to sustainability. One of the major goals for the Department of Energy is to achieve energy savings with a corresponding reduction in carbon foot print. The use of a coupled induction heat treatment with high magnetic field heat treatment makes possible not only improved performance alloys, but with faster processing times and lower processing energy, as well. With this technology, substitution of lower cost alloys for more exotic alloys became a possibility; microstructure could be tailored for improved magnetic properties or wear resistance or mechanical performance, as needed. A prototype commercial unit has been developed to conduct processing of materials. Testing of this equipment has been conducted and results demonstrate the feasibility for industrial commercialization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating technology upgrades as a complement to traditional bill assistance programs

State programs to improve energy affordability and reduce energy burden (the share of income spent on energy) could mitigate concerns about rising electricity prices. Many states offer bill assistance and rebates for weatherization and rooftop solar to income-qualifying households. Here, we analyse how these approaches may complement one another to improve energy affordability. Results illustrate trade offs between program costs and energy burden reduction, as well as between a program’s upfront and ongoing costs. Generally, the three strategies complement one another to improve energy affordability at lower net present cost than bill assistance alone, with varying effects across regions. Weatherization can reduce the solar installation capacity needed, and both together can reduce or eliminate ongoing reliance on bill assistance. Under full uptake among cost-effective households, fully rebated weatherization and solar rebated at $0.48/Watt, combined with bill assistance, yield the same modelled net present cost as bill assistance alone while reducing the share of low-income owner-occupied households with high energy burdens from 66% to 19%, compared with 34% under bill assistance alone. Absent tax credits, weatherization still reduces energy burden and bill assistance program costs, whereas solar may not be cost-competitive.

Forrester, Sydney P↗

Editorial for Special Issue: Grid-Interactive Efficient Buildings - Part 1

We are pleased to present starting with this volume of ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC), a series of peer-reviewed papers related to some of ongoing research projects and applications of Grid-interactive Efficient Buildings (GEBs). As part of a new program initiated by the Building Technology Office (BTO) with the US Department of Energy (DOE), GEBs are characterized as highly energy-efficient buildings that are equipped with smart technologies and distributed energy resources that can be dynamically controlled to meet grid needs and minimize electricity system costs, while meeting occupants’ comfort and productivity requirements. In simple terms,DOE defines GEBs as efficient, connected, smart, and flexible buildings. The GEB technologies touch on the main topical areas of JESBC aimed at fostering sustainable buildings and cities by providing results of evaluation studies and demonstration projects. Indeed, one of the main goals for JESBC is to disseminate solutions to enhance the built environment energy efficiencies, low carbon services, inter-connectivity services, resilient multi-services, and healthy and comfortable living spaces.

buildings↗

Summary of: Simulating the Value of Concentrating Solar Power with Thermal Energy Storage in a Production Cost Model (Presentation)

Concentrating solar power (CSP) deployed with thermal energy storage (TES) provides a dispatchable source of renewable energy. The value of CSP with TES, as with other potential generation resources, needs to be established using traditional utility planning tools. Production cost models, which simulate the operation of grid, are often used to estimate the operational value of different generation mixes. CSP with TES has historically had limited analysis in commercial production simulations. This document describes the implementation of CSP with TES in a commercial production cost model. It also describes the simulation of grid operations with CSP in a test system consisting of two balancing areas located primarily in Colorado.

14 SOLAR ENERGY↗

Building America Best Practices Series - Volume 15: 40% Whole-House Energy Savings in the Hot-Humid Climate

This best practices guide is the 15th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Building America↗

Building America Best Practices Series - Volume 16: 40% Whole-House Energy Savings in the Mixed-Humid Climate

This best practices guide is the 16th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the mixed-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Building America↗

Retrofittable Thermal Switches for Dynamic Building Envelopes Integrated with Thermal Energy Storage: Preprint

Buildings in the United States consume about 40 quadrillion BTU of primary energy annually, which accounts for the nation's 40% of total energy use, 75% of all electricity use, and 35% of the net carbon emissions. Deploying thermal energy storage in the form of phase change material (PCM) in building envelopes is an effective method to reduce space heating/cooling loads, provide load shedding, and shift demand to periods of lower energy cost. However, the full potential of PCM-integrated envelopes can only be realized if the PCM undergoes complete phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Conventional thermal insulation (with a fixed thermal resistance) limits PCM utilization, particularly with the increasing emphasis on higher R-value in building envelopes, which negatively affects the energy-saving potential of a PCM-integrated envelope. In contrast, dynamic building envelopes integrated with PCMs provide the option of varying the thermal resistance based on the indoor and outdoor conditions, thereby enhancing utilization of free ambient cooling and heating to charge/discharge the PCM thermal storage, reducing the buildings' heating and cooling load, and shifting the peak energy demand. In this study, we demonstrate innovative retrofittable thermal switches in the form of the insertable plugs inside an insulation to provide variable thermal resistance depending on the operating temperature and direction of temperature gradient, thus allowing preferential directional heat flow. Notably, they are passive in nature, requiring no external power, and work solely based on the ambient temperature.

buildings↗

Net-baryon diffusion in fluid-dynamic simulations of relativistic heavy-ion collisions

A hybrid (hydrodynamics + hadronic transport) theoretical framework is assembled to model the bulk dynamics of relativistic heavy-ion collisions at energies accessible in the Beam Energy Scan (BES) program at the Relativistic Heavy-Ion Collider (RHIC) and the NA61/SHINE experiment at CERN. The system's energy-momentum tensor and net baryon current are evolved according to relativistic hydrodynamics with finite shear viscosity and non-zero net baryon diffusion. Our hydrodynamic description is matched to a hadronic transport model in the dilute region. With this fully integrated theoretical framework, we present a pilot study of the hadronic chemistry, particle spectra, and anisotropic flow. Phenomenological effects of a non-zero net-baryon current and its diffusion on hadronic observables are presented for the first time. Furthermore, the importance of the hadronic transport phase is also investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Hybrid Biophysical‐Machine Learning Framework for Diurnal Surface Energy Flux Estimation Using Proximal Sensing

Thermal infrared-based remote sensing of surface energy fluxes has traditionally relied on high spatial resolution satellite data with revisit frequencies on the order of weeks. In this study, we evaluate a biophysics-based analytical surface energy balance model for predicting latent energy ( LE ) and sensible heat ( H ) fluxes using proximal sensing observations. The Surface Temperature Initiated Closure (STIC1.2) model has been extensively validated across a wide range of spatial and temporal scales using various satellite-derived thermal infrared data sets. Here we extend this validation by applying STIC at sub-hourly temporal resolution over multiple growing seasons for four distinct agricultural systems. We further develop and evaluate novel STIC variants that incorporate machine learning (ML) techniques to eliminate the need for surface energy balance observations, specifically net radiation and soil heat flux, thereby enhancing model applicability in data-sparse settings. The integration of a ML component to estimate surface available energy is shown to have strong predictive performance for both LE (R 2 = 0.81–0.94) and H (R 2 = 0.46–0.72) across all agricultural systems examined here, demonstrating the potential of hybrid biophysical-machine learning approaches for surface energy balance modeling with minimal data requirements. This study concludes with a novel application of explainable machine learning (exML) to diagnose sources of model error. This exML framework attributes residual prediction errors to both model input variables and environmental drivers not explicitly included in the simulation experiments. This approach provides a new pathway for improving model design and integrating previously overlooked yet influential variables into future model iterations.

evapotranspiration↗

Data for: A hybrid biophysical-machine learning framework for diurnal surface energy flux estimation using proximal sensing

Thermal-based remote sensing of surface energy fluxes has traditionally relied on high spatial resolution satellite data with revisit frequencies on the order of weeks. In this study, we evaluate a biophysics-based analytical surface energy balance model for predicting latent energy (LE) and sensible heat (H) fluxes using proximal sensing observations. The Surface Temperature Initiated Closure (STIC1.2) model has been extensively validated across a wide range of spatial and temporal scales using various satellite-derived thermal datasets. Here we extend this validation by applying STIC at sub-hourly temporal resolution over multiple growing seasons for four distinct agricultural systems. We further develop and evaluate novel STIC variants that incorporate machine learning (ML) techniques to eliminate the need for specific surface energy balance observations, specifically net radiation and soil heat flux, thereby enhancing model applicability in data-sparse settings. The integration of an ML component to estimate surface available energy is shown to have strong predictive performance for both LE (R2 = 0.81-0.94) and H (R2 = 0.46-0.72) across all agricultural systems examined here, demonstrating the potential of hybrid biophysical – machine learning approaches for surface energy balance modeling with minimal data requirements. This study concludes with a novel application of explainable machine learning (exML) to diagnose sources of model error. This exML framework attributes residual prediction errors to both model input variables and environmental drivers not explicitly included in the simulation experiments. This approach provides a new pathway for improving model design and integrating previously overlooked yet influential variables into future model iterations.

Agricultural Sciences↗

( NuSTAR NuSTAR) discovery of a cyclotron line in the accreting X-ray pulsar IGR J16393-4643

The high-mass X-ray binary and accreting X-ray pulsar IGR J16393-4643 was observed by the Nuclear Spectroscope Telescope Array in the 3–79 keV energy band for a net exposure time of 50 ks. We present the results of this observation which enabled the discovery of a cyclotron resonant scattering feature with a centroid energy of 29.3{sub −1.3}{sup +1.1} keV. This allowed us to measure the magnetic field strength of the neutron star for the first time: B = (2.5 ± 0.1) × 10{sup 12} G. The known pulsation period is now observed at 904.0 ± 0.1 s. Since 2006, the neutron star has undergone a long-term spin-up trend at a rate of P-dot =−2×10{sup −8} s s{sup −1} (−0.6 s per year, or a frequency derivative of ν-dot =3×10{sup −14} Hz s{sup −1}). In the power density spectrum, a break appears at the pulse frequency which separates the zero slope at low frequency from the steeper slope at high frequency. This addition of angular momentum to the neutron star could be due to the accretion of a quasi-spherical wind, or it could be caused by the transient appearance of a prograde accretion disk that is nearly in corotation with the neutron star whose magnetospheric radius is around 2 × 10{sup 8} cm.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

Rooftop Solar Deployment, Potential Electricity Rate Impacts, and the Timing of Revisions to State Net Metering Policy

Most U.S. states require utilities to credit residential solar photovoltaic (PV) output at the retail electricity rate, a structure known as net metering. However, 12 states have replaced net metering with alternative rate structures that reduce PV adopter bill savings. The share of households living in states that require net metering fell from around 84% in 2014 to around 57% by the end of 2023. Proponents of net metering revisions have argued that net metering can affect the electricity rates of customers without PV. This report analyzes the relationships between state PV deployment levels, potential electricity rate impacts on PV nonadopters, and the timing of revisions to net metering policy.

14 SOLAR ENERGY↗

The Net Zero World Initiative

The U.S. is committed to working with countries all over the globe to accelerate clean climate goals from ambition to action, and the Net Zero World Initiative is the latest example of our dedication. The Net Zero World Initiative is uniquely positioned to achieve rapid global energy decarbonization. It will partner with countries to help them implement climate ambition pledges and accelerate global transitions to net zero, resilient, and inclusive energy systems. The Net Zero World Initiative Will Harness Unique USG and Lab Assets in Partnership with Philanthropies. Scale-up and goals listed.

accelerate↗