Search NASA⌕ Search

SEARCH · Search NASA

Results for “PENETRATION DEPTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Free Electron Laser Measurement of Liquid Carbon Reflectivity in the Extreme Ultraviolet

Ultrafast time-resolved extreme ultraviolet (EUV) reflectivity measurements of optically pumped amorphous carbon (a-C) have been performed with the FERMI free electron laser (FEL). This work extends the energy range used in previous reflectivity studies and adds polarization dependence. The EUV probe is known to be sensitive to lattice dynamics, since in this range the reflectivity is essentially unaffected by the photo-excited surface plasma. The exploitation of both s- and p-polarized EUV radiation permits variation of the penetration depth of the probe; a significant increase in the characteristic time is observed upon increasing the probing depth (1 vs. 5 ps) due to hydrodynamic expansion and consequent destruction of the excited region, implying that there is only a short window during which the probed region is in the isochoric regime. A weak wavelength dependence of the reflectivity is found, consistent with previous measurements and implying a maximum electronic temperature of 0.8 eV ± 0.4.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure and Interdigitation of Chain-Asymmetric Phosphatidylcholines and Milk Sphingomyelin in the Fluid Phase

We addressed the frequent occurrence of mixed-chain lipids in biological membranes and their impact on membrane structure by studying several chain-asymmetric phosphatidylcholines and the highly asymmetric milk sphingomyelin. Specifically, we report trans-membrane structures of the corresponding fluid lamellar phases using small-angle X-ray and neutron scattering, which were jointly analyzed in terms of a membrane composition-specific model, including a headgroup hydration shell. Focusing on terminal methyl groups at the bilayer center, we found a linear relation between hydrocarbon chain length mismatch and the methyl-overlap for phosphatidylcholines, and a non-negligible impact of the glycerol backbone-tilting, letting the sn1-chain penetrate deeper into the opposing leaflet by half a CH 2 group. That is, penetration-depth differences due to the ester-linked hydrocarbons at the glycerol backbone, previously reported for gel phase structures, also extend to the more relevant physiological fluid phase, but are significantly reduced. Moreover, milk sphingomyelin was found to follow the same linear relationship suggesting a similar tilt of the sphingosine backbone. Complementarily performed molecular dynamics simulations revealed that there is always a part of the lipid tails bending back, even if there is a high interdigitation with the opposing chains. The extent of this back-bending was similar to that in chain symmetric bilayers. For both cases of adaptation to chain length mismatch, chain-asymmetry has a large impact on hydrocarbon chain ordering, inducing disorder in the longer of the two hydrocarbons.

59 BASIC BIOLOGICAL SCIENCES↗

High-Frequency 3D Photoacoustic Computed Tomography Using an Optical Microring Resonator

3D photoacoustic computed tomography (3D-PACT) has made great advances in volumetric imaging of biological tissues, with high spatial-temporal resolutions and large penetration depth. The development of 3D-PACT requires high-performance acoustic sensors with a small size, large detection bandwidth, and high sensitivity. In this work, we present a new high-frequency 3D-PACT system that uses a microring resonator (MRR) as the acoustic sensor. The MRR sensor has a size of 80 μ m in diameter and was fabricated using the nanoimprint lithography technology. Using the MRR sensor, we have developed a transmission-mode 3D-PACT system that has achieved a detection bandwidth of ~23 MHz, an imaging depth of ~8 mm, a lateral resolution of 114 μ m, and an axial resolution of 57 μ m. We have demonstrated the 3D PACT’s performance on in vitro phantoms, ex vivo mouse brain, and in vivo mouse ear and tadpole. The MRR-based 3D-PACT system can be a promising tool for structural, functional, and molecular imaging of biological tissues at depths.

47 OTHER INSTRUMENTATION↗

Nondestructive Measurement of Residual Strain in Connecting Rods Using Neutrons

Increasing the strength of materials is effective in reducing weight and boosting structural part performance, but there are cases where the residual strain generated during the process of manufacturing of high-strength materials results in a decline of durability. It is therefore important to understand how the residual strain in a manufactured component changes due to processing conditions. In the case of a connecting rod, because the strain load on the connecting rod rib sections is high, it is necessary to clearly understand the distribution of strain in the ribs. However, because residual strain is generally measured by using X-ray diffractometers or strain gauges, measurements are limited to the surface layer of the parts. Neutron beams, however, have a higher penetration depth than X-rays, allowing for strain measurement in the bulk material. The research discussed within this article consists of nondestructive residual strain measurements in the interior of connecting rods using the Second Generation Neutron Residual Stress Mapping Facility (NRSF2) at Oak Ridge National Laboratory (ORNL), measuring the Fe (211) diffraction peak position of the ferrite phase. The interior strain distribution of the connecting rod, which was prepared under different manufacturing processes, was revealed. By the visualization of interior strains, clear understandings of differences in various processing conditions were obtained. In addition, it is known that the peak width, which is also obtained during measurement, is suggestive of the size of crystallites in the structure; however, the peak width can additionally be caused by microstresses and material dislocations.

36 MATERIALS SCIENCE↗

Non-Destructive Measurement of Residual Strain in Connecting Rods Using Neutrons

Increasing the strength of materials is effective in reducing weight and boosting structural part performance, but there are cases in where the residual strain generated during the process of manufacturing of high-strength materials results in a decline of durability. It is therefore important to understand how the residual strain in a manufactured component changes due to processing conditions. In the case of a connecting rod, because the strain load on the connecting rod rib sections is high, it is necessary to clearly understand the distribution of strain in the ribs. However, because residual strain is generally measured by using X-ray diffractometers or strain gauges, measurements are limited to the surface layer of the parts. Neutron beams, however, have a higher penetration depth than X-rays, allowing for strain measurement in the bulk material. The research discussed within this paper consists of non-destructive residual strain measurements in the interior of connecting rods using the 2nd Generation Neutron Residual Stress Mapping Facility (NRSF2) at Oak Ridge National Laboratory, measuring the Fe (211) diffraction peak position of the ferrite phase. The interior strain distribution of connecting rod, which prepared under different manufacturing processes, was revealed. By the visualization of interior strains, clear understandings of differences in various processing conditions were obtained. In addition, it is known that the peak width, which is also obtained during measurement, is suggestive of the size of crystallites in the structure; however the peak width can additionally be caused by microstresses and material dislocations.

Ikeda, Tomohiro↗

Correcting for filter-based aerosol light absorption biases at the Atmospheric Radiation Measurement program's Southern Great Plains site using photoacoustic measurements and machine learning

Abstract. Measurement of light absorption of solar radiation by aerosols is vital for assessing direct aerosol radiative forcing, which affects local and global climate. Low-cost and easy-to-operate filter-based instruments, such as the Particle Soot Absorption Photometer (PSAP), that collect aerosols on a filter and measure light attenuation through the filter are widely used to infer aerosol light absorption. However, filter-based absorption measurements are subject to artifacts that are difficult to quantify. These artifacts are associated with the presence of the filter medium and the complex interactions between the filter fibers and accumulated aerosols. Various correction algorithms have been introduced to correct for the filter-based absorption coefficient measurements toward predicting the particle-phase absorption coefficient (Babs). However, the inability of these algorithms to incorporate into their formulations the complex matrix of influencing parameters such as particle asymmetry parameter, particle size, and particle penetration depth results in prediction of particle-phase absorption coefficients with relatively low accuracy. The analytical forms of corrections also suffer from a lack of universal applicability: different corrections are required for rural and urban sites across the world. In this study, we analyzed and compared 3 months of high-time-resolution ambient aerosol absorption data collected synchronously using a three-wavelength photoacoustic absorption spectrometer (PASS) and PSAP. Both instruments were operated on the same sampling inlet at the Department of Energy's Atmospheric Radiation Measurement program's Southern Great Plains (SGP) user facility in Oklahoma. We implemented the two most commonly used analytical correction algorithms, namely, Virkkula (2010) and the average of Virkkula (2010) and Ogren (2010)–Bond et al. (1999) as well as a random forest regression (RFR) machine learning algorithm to predict Babs values from the PSAP's filter-based measurements. The predicted Babs was compared against the reference Babs measured by the PASS. The RFR algorithm performed the best by yielding the lowest root mean square error of prediction. The algorithm was trained using input datasets from the PSAP (transmission and uncorrected absorption coefficient), a co-located nephelometer (scattering coefficients), and the Aerosol Chemical Speciation Monitor (mass concentration of non-refractory aerosol particles). A revised form of the Virkkula (2010) algorithm suitable for the SGP site has been proposed; however, its performance yields approximately 2-fold errors when compared to the RFR algorithm. To generalize the accuracy and applicability of our proposed RFR algorithm, we trained and tested it on a dataset of laboratory measurements of combustion aerosols. Input variables to the algorithm included the aerosol number size distribution from the Scanning Mobility Particle Sizer, absorption coefficients from the filter-based Tricolor Absorption Photometer, and scattering coefficients from a multiwavelength nephelometer. The RFR algorithm predicted Babs values within 5 % of the reference Babs measured by the multiwavelength PASS during the laboratory experiments. Thus, we show that machine learning approaches offer a promising path to correct for biases in long-term filter-based absorption datasets and accurately quantify their variability and trends needed for robust radiative forcing determination.

54 ENVIRONMENTAL SCIENCES↗

Modified algesimeter provides accurate depth measurements

Algesimeter which incorporates a standard sensory needle with a sensitive micrometer, measures needle point depth penetration in pain tolerance research. This algesimeter provides an inexpensive, precise instrument with assured validity of recordings in those biomedical areas with a requirement for repeated pain detection or ascertaining pain sensitivity.

Turner, D. P.↗

Response of mouse epidermal cells to single doses of heavy-particles

The survival of mouse epidermal cells to heavy-particles has been studied In Vivo by the Withers clone technique. Experiments with accelerated helium, lithium and carbon ions were performed. The survival curve for the helium ion irradiations used a modified Bragg curve method with a maximum tissue penetration of 465 microns, and indicated that the dose needed to reduce the original cell number to 1 surviving cell/square centimeters was 1525 rads with a D sub o of 95 rads. The LET at the basal cell layer was 28.6 keV per micron. Preliminary experiments with lithium and carbon used treatment doses of 1250 rads with LET's at the surface of the skin of 56 and 193 keV per micron respectively. Penetration depths in skin were 350 and 530 microns for the carbon and lithium ions whose Bragg curves were unmodified. Results indicate a maximum RBE for skin of about 2 using the skin cloning technique. An attempt has been made to relate the epidermal cell survival curve to mortality of the whole animal for helium ions.

Leith, J. T.↗

Lunar surface mechanical properties from Surveyor data.

During the Surveyor program spacecraft were successfully landed at five widely separated lunar locations. Recent computer simulations of each landing have provided more comprehensive data on the mechanical properties of the lunar surface than have been obtained previously by this method of analysis. Results show that the variations in surface bearing pressure observed at the various lunar sites are probably due to surface slope effects and do not necessarily indicate differences in soil properties at these sites. Estimates of cohesion at two sites give almost identical results and further support the conclusion that the soil properties at all sites are probably very similar. Surface pressures that resist horizontal (plowing) motion are largely due to cohesion, and density and gravitational contributions are small. It is concluded that the lunar surface bearing strength is essentially zero at the surface and, for zero surface slope, increases with penetration depth at a rate of 1.87 (plus or minus 0.33) N/cu cm. The cohesion of the lunar soil is estimated to be between 0.11 and 0.17 N/sq cm.

Jones, R. H.↗

Microwave emission from geological materials - Observations of interference effects.

Microwave radiometric field observations were conducted at wavelengths of 21, 2.8, and 0.95 cm to determine the microwave penetration depth of a number of sands and gravels as a function of particle size and moisture content. Observations of a reflecting plate covered with varying thicknesses of test material exhibit a pronounced oscillatory behavior that is consistent with established electromagnetic theory for plane-parallel layered mediums. Utilization of this interference effect is proposed as a microwave radiometric technique for determining the bulk electrical properties of geologic materials, snow, ice, and other materials readily adapted to layering experiments.

Blinn, J. C., III↗

Magnetic flux penetration into superconducting thin films.

The quantum-interference technique developed by Meservey (1965) is used to measure directly the absolute value of the penetration depth in lead in tin superconducting thin films. The technique assumes that the change in phase of the superconducting wave function around any contour within the superconductor must be 2 pi n, where n is a nonnegative integer. Results show that the critical current of a superconducting interferometer with two parallel junctions is not strictly periodic in the applied magnetic flux with a period equal to the flux quantum because of the magnetic field dependence of the critical currents of the junctions.

Peabody, G. E.↗

Self-recording portable soil penetrometer

A lightweight portable penetrometer for testing soil characteristics is described. The penetrometer is composed of a handle, data recording, and probe components detachably joined together. The data recording component has an easily removed recording drum which rotates according to the downward force applied on the handle, and a stylus means for marking the drum along its height according to the penetration depth of probe into the soil.

Costes, N. C.↗

Aircraft and satellite monitoring of water quality in Lake Superior near Duluth

Satellite images and low altitude aerial photographs often show vivid discolorations in water bodies. Extensive laboratory analysis shows that water reflectance, which causes brightness on aerial images, positively correlates to the water quality parameter of turbidity, which on a particular day correlates to suspended solids. Work with low altitude photography on three overcast days and with ERTS images on five clear days provides positive correlation of image brightness to the high turbidity and solids which are present in Lake Superior near Duluth over 50% of the time. Proper use of aerial images would have shown that an $8,000,000 drinking water intake constructed in the midst of this unpotable, turbid water should have been located 6 miles north in clear, usable water. Noise effects such as skylight reflection, atmospheric effects, and depth penetration also must be understood for operational use of remote sensing for water quality monitoring and are considered in the paper.

Scherz, J. P.↗

The role of horizontal transport as evaluated from the Apollo 15 and 16 orbital experiments

Despite the large amount of accumulated data there is still considerable debate about the role of various processes in the formation of the lunar surface. One of the processes frequently discussed is that of horizontal transport and how it affected surface chemistry and surface features. The orbital experiments flown on Apollo 15 and 16 enable us to consider the extent of horizontal transport. In particular, the X-ray experiment because of its low penetration depth permits us to make at least crude estimates of the extent of horizontal transport.

Adler, I.↗

Surface recombination velocity and diffusion length of minority carriers in heavily doped silicon layers

Quantitative analysis of the electron beam-induced current and the dependence of the effective diffusion length of the minority carriers on the penetration depth of the electron beam were employed for the analysis of the carrier recombination characteristics in heavily doped silicon layers. The analysis is based on the concept of the effective excitation strength of the carriers which takes into consideration all possible recombination sources. Two dimensional mapping of the surface recombination velocity of P-diffused Si layers will be presented together with a three dimensional mapping of minority carrier lifetime in ion implanted Si. Layers heavily doped with As exhibit improved recombination characteristics as compared to those of the layers doped with P.

Gatos, H. C.↗

Interpretation of scanning electron microscope measurements of minority carrier diffusion lengths in semiconductors

In scanning electron microscope (SEM) injection measurements of minority carrier diffusion lengths some uncertainties of interpretation exist when the response current is nonlinear with distance. This is significant in epitaxial layers where the layer thickness is not large in relation to the diffusion length, and where there are large surface recombination velocities on the incident and contact surfaces. An image method of analysis is presented for such specimens. A method of using the results to correct the observed response in a simple convenient way is presented. The technique is illustrated with reference to measurements in epitaxial layers of GaAs. Average beam penetration depth may also be estimated from the curve shape.

Flat, A.↗

Verifying root fusion in electron-beam welds

Ultrasonic equipment and x-y recorder indicate where back side of joint is properly welded. Wire waveguide placed in groove at root of joint to be welded is fused when joint is adequately penetrated. Ultransonic signal moving down waveguide is reflected where guide is melted. Change in reflected-signal arrival time with change in weld-head position is nearly constant unless joint is incompletely penetrated. Method permits determination of penetration depth in preweld samples without opening vacuum chamber and sectioning weld. Technique is particularly valuable when back side of joint is inaccessible.

Becker, F. L.↗