Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Fabrication and test of a variable conductance heat pipe

A variable conductance heat pipe (VCHP) with feedback control was fabricated with a reservoir-condenser volume ratio of 10 and an axially grooved action section. Tests of the heat transport capability were greater than or equal to the analytical predictions for the no gas case. When gas was added, the pipe performance degraded by 18% at zero tilt as was expected. The placement of the reservoir heater and the test fixture cooling fins are believed to have caused a superheated vapor condition in the reservoir. Erroneously high reservoir temperature indications resulted from this condition. The observed temperature gradients in the reservoir lend support to this theory. The net result was higher than predicted reservoir temperatures. Also, significant increases in minimum heat load resulted for controller set point temperatures higher than 0 C. At 30 C, control within the tolerance band was maintained, but high reservoir heater power was required. Analyses showed that control is not possible for reasonably low reservoir heater power. This is supported by the observation of a significant reservoir heat leak through the condenser.

Lehtinen, A. M.↗

Performance of a thermionic converter module utilizing emitter and collector heat pipes

A thermionic converter module simulating a configuration for an out-of-core thermionic nuclear reactor was designed, fabricated, and tested. The module consists of three cylindrical thermionic converters. The tungsten emitter of the converter is heated by a tungsten, lithium heat pipe. The emitter heat pipes are immersed in a furnace, insulated by MULTI-FOIL thermal insulation, and heated by tungsten radiation filaments. The performance of each thermionic converter was characterized before assembly into the module. Dynamic voltage, current curves were taken using a 60 Hz sweep and computerized data acquisition over a range of emitter, collector, and cesium-reservoir temperatures. An output power of 215 W was observed at an emitter temperature of 1750 K and a collector temperature of 855 K for a two diode module. With a three diode module, an output power of 270 W was observed at an average emitter temperature of 1800 K and a Collector temperature of 875 K.

Kroeger, E. W.↗

CTS TEP thermal anomalies: Heat pipe system performance

A part of the investigation is summarized of the thermal anomalies of the transmitter experiment package (TEP) on the Communications Technology Satellite (CTS) which were observed on four occasions in 1977. Specifically, the possible failure modes of the variable conductance heat pipe system (VCHPS) used for principal thermal control of the high-power traveling wave tube in the TEP are considered. Further, the investigation examines how those malfunctions may have given rise to the TEP thermal anomalies. Using CTS flight data information, ground test results, analysis conclusions, and other relevant information, the investigation concentrated on artery depriming as the most likely VCHPS failure mode. Included in the study as possible depriming mechanisms were freezing of the working fluid, Marangoni flow, and gas evolution within the arteries. The report concludes that while depriming of the heat pipe arteries is consistent with the bulk of the observed data, the factors which cause the arteries to deprime have yet to be identified.

Marcus, B. D.↗

Condensation heat transfer in rotating heat pipes in the presence of a non-condensable gas

An analysis of condensation problems in rotating heat pipes containing vapors with different concentrations of non-condensable gases is given. In situations such as this, temperature and concentration gradients are set up in the vapor-gas mixture. There is a transport of mass due to temperature gradients accompanied by an energy transport phenomena due to a concentration gradient. A Nusselt type analysis is not suited to this type of problem; however, a boundary layer type approach has successfully been used to analyze stationary condensation systems with non-condensable gases present. The present boundary layer analysis is presented for condensation processes on the inside of a rotating heat pipe in the presence of non-condensable gases.

Daniels, T. C.↗

Experimental temperature distribution and heat load characteristics of rotating heat pipes

Experimental results show conclusively that the presence of a small quantity of a noncondensable gas (NCG) mixed with the working fluid has a considerable effect on the condensation process in a rotating heat pipe. The temperature distribution in the condenser shows the blanketing effect of the NCG and the ratio of the molecular weight of the working fluid to that of the NCG has a very definite effect on the shape of this distribution. Some of the effects are quite similar to the well-established data on stationary heat pipes.

Daniels, T. C.↗

Heat pipe technology. A bibliography with abstracts

This bibliography cites 55 publications on the theory, design, development, fabrication, and testing of heat pipes. Applications covered include solar, nuclear, and thermoelectric energy conversion. A book (in Russian) on low temperature heat pipes is included as well as abstracts when available. Indexes provided list authors, titles/keywords (permuted) and patents.

Source record↗

Cryogenic thermal diode heat pipes

The development of spiral artery cryogenic thermal diode heat pipes was continued. Ethane was the working fluid and stainless steel the heat pipe material in all cases. The major tasks included: (1) building a liquid blockage (blocking orifice) thermal diode suitable for the HEPP space flight experiment; (2) building a liquid trap thermal diode engineering model; (3) retesting the original liquid blockage engineering model, and (4) investigating the startup dynamics of artery cryogenic thermal diodes. An experimental investigation was also conducted into the wetting characteristics of ethane/stainless steel systems using a specially constructed chamber that permitted in situ observations.

Alario, J.↗

Shuttle Ku-band bent-pipe implementation considerations

This paper describes an approach for relay of data-modulated subcarriers from Shuttle payloads through the Shuttle Ku-band communications subsystem (and subsequently through a tracking and data relay satellite system to a ground terminal). The novelty is that a channel originally provided for baseband digital data is shown to be suitable for this purpose; the resulting transmission scheme is referred to as a narrowband bent-pipe scheme. Test results demonstrating the validity of the narrowband bent-pipe mode are presented, and limitations on system performance are described.

Batson, B. H.↗

Heat-pipe sensor for remote leveling

System gives level readings in inaccessible areas. Level sensor is equipped with three thermocouples used to measure temperature differences that arise when pipe is tilted. When platform on which pipe is resting is level, three thermocouple recordings are identical. When readings are unequal, platform is leveled by remote control. System can replace expensive optical equipment and can function in cold, vacuum, and hot humid environments that produce nonlinear expansion and contraction in conventional equipment. Other advantages include low cost, no moving parts, and operation in toxic environments.

Marshburn, J. P.↗

Meteoroid Protection Methods for Spacecraft Radiators Using Heat Pipes

Various aspects of achieving a low mass heat pipe radiator for the nuclear electric propulsion spacecraft were studied. Specific emphasis was placed on a concept applicable to a closed Brayton cycle power sub-system. Three aspects of inter-related problems were examined: (1) the armor for meteoroid protection, (2) emissivity of the radiator surface, and (3) the heat pipe itself. The study revealed several alternatives for the achievement of the stated goal, but a final recommendation for the best design requires further investigation.

Ernst, D. M.↗

Feasibility and cost study on VOIR SAR data transfer via a bent pipe link

An INTELSAT/DOMSAT double hop bent pipe link for the Venus orbiting imaging radar synthetic aperture radar imaging data transfer from deep space stations 43 and 63 to the Jet Propulsion Laboratory was investigated. The cost for the bent pipe transfer was estimated and compared to that for the planned tape record/airfreight-the-tape transfer method.

Park, Y. H.↗

Heat pipe cooling of power processing magnetics

The constant demand for increased power and reduced mass has raised the internal temperature of conventionally cooled power magnetics toward the upper limit of acceptability. The conflicting demands of electrical isolation, mechanical integrity, and thermal conductivity preclude significant further advancements using conventional approaches. However, the size and mass of multikilowatt power processing systems may be further reduced by the incorporation of heat pipe cooling directly into the power magnetics. Additionally, by maintaining lower more constant temperatures, the life and reliability of the magnetic devices will be improved. A heat pipe cooled transformer and input filter have been developed for the 2.4 kW beam supply of a 30-cm ion thruster system. This development yielded a mass reduction of 40% (1.76 kg) and lower mean winding temperature (20 C lower). While these improvements are significant, preliminary designs predict even greater benefits to be realized at higher power. This paper presents the design details along with the results of thermal vacuum operation and the component performance in a 3 kW breadboard power processor.

Hansen, I. G.↗

Heat Pipe Blocks Return Flow

Metal-foil reed valve in conventional slab-wick heat pipe limits heat flow to one direction only. With sink warmer than source, reed is forced closed and fluid returns to source side through annular transfer wick. When this occurs, wick slab on sink side of valve dries out and heat pipe ceases to conduct heat.

Eninger, J. E.↗

Modal content of noise generated by a coaxial jet in a pipe

Measurements of the hydrodynamic pressure fluctuation levels showed that, for circular obstructions with a flow passage diameter less than one-half of the pipe diameter, hydrodynamic pressure fluctuations were small compared with the acoustic pressure, at locations greater than ten pipe diameters downstream of the restrictions. Thus, in the study currently reported, which was concentrated on measurement of the modal characteristics of the sound field downstream of the restrictions, special techniques to avoid contamination by hydrodynamic 'noise' were not necessary. The major results obtained in the study are scaling laws for the shape of the modal pressure spectrum and for the overall efficiency of noise generation. The characteristics of the modal pressure spectra are discussed. It is shown that the primary parameter controlling the spectrum shape is the frequency ratio (Helmholtz number/Strouhal number). The efficiency levels when plotted as a function of Mach number show a strong dependence on restriction size

Kerschen, E. J.↗

Vibrations of three-dimensional pipe systems with acoustic coupling

A general algorithm is developed to calculate the beam-type dynamic response of three dimensional multiplane finite length pipe systems, consisting of elbow and straight ducts with continuous interfaces. Emphasis is on secondary acoustic wave effects giving rise to coupling mechanisms; and the simulation accounts for one-dimensional elastoacoustic coupling from a plane acoustic wave and secondary loads resulting from wave asymmetries. The transfer matrix approach is adopted in modeling the elastodynamics of each duct, with allowance for distribution loads. Secondary loads from plane wave distortion are considered with a solution of the Helmholtz equation in an equivalent rigid waveguide, and effects of path imperfection are introduced as a perturbation from the hypothetical perfectly straight pipe. Computations indicate that the one-dimensional acoustic assumption is valid for frequencies below one-half the first cut-off frequency, and the three-dimensional acoustic effects produce an increase in response levels near and above cut-off.

El-Raheb, M.↗

Heat Pipe Design Handbook: Volume II

This volume consists of a discussion of Fluid Properties (Chapter 1) and a description of the available Heat Pipe Computer Codes (Chapter 2). Appendix A contains appropriate International Scientific Units (SI) and Conversion Factors. The Users Manual for the Heat Pipe Fluid Properties Program (HPF) which is used to generate the fluid property data is presented in Appendix B. Tabulated fluid property data are listed in Appendix C.

Brennan, Patrick J.↗

Pipe-Thread Vacuum Seal

Lead/tin solder coating on pipe threads serves as seal in non-critical vacuum systems. Pipe-thread seal is less expensive than weld or knife-edge flanges. Can also be used in place of sealing tape.

Chandler, J. A.↗