Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROFILE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Full wave effects on the lower hybrid wave spectrum and driven current profile in tokamak plasmas

A numerical modeling of current profile modification by lower hybrid current drive (LHCD) using a fullwave/Fokker-Planck simulation code is presented. A MHD stable LHCD discharge on Alcator C-Mod was analyzed, and the current profile from full wave simulations was found to show better agreement with the experiment than a ray-tracing code. Comparison of full wave and ray-tracing simulation shows that, although ray-tracing can reproduce the stochastic wave spectrum broadening, the full wave calculation predicts even wider spectrum broadening, and the wave spectrum fills all of the kinematically allowed domain. This is the first demonstration of LHCD current profile modeling using a full wave simulation code in a multi-pass absorption regime, showing the clear impact of full wave effects on the LHCD driven current profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study on plasma edge boundary in ergodic layer of LHD based on radial profile measurement of impurity line emissions

Vertical profiles of edge impurity emissions have been measured in upper half region of elliptical plasmas at horizontally elongated plasma cross section in large helical device (LHD). The vertical profiles near upper O-point located just below helical coil are analyzed to study the plasma edge boundary of the ergodic layer consisting of stochastic magnetic field lines with connection lengths of 30 {<=} L{sub c} {<=} 2000 m. As a result, C{sup 3+} ion emitting CIV spectrum is identified as the ion existing in the farthest edge of the ergodic layer. The peak position of CIV (312.4 A: 1s{sup 2}3p {sup 2}P{sub 1/2,3/2}-1s{sup 2}2s {sup 2}S{sub 1/2}) vertical profile does not change at all in a wide temperature range of 150 {<=} T{sub e}({rho} = 1) {<=} 400 eV, whereas it moves inside the ergodic layer when T{sub e}({rho} = 1) is reduced below a threshold temperature, e.g., 130 eV at R{sub ax} = 3.75 m configuration. It is found that the C{sup 3+} ion exists at the boundary between ergodic layer and open magnetic filed layer at which the L{sub c} distributes in lengths of 5 to 30 m. The result indicates that the edge boundary near the O-point in LHD is determined by a starting point of the open filed layer, where a tokamak-like steeper edge temperature gradient is formed, although the edge boundary is quite obscure at the X-point region. Any plasma does not exist between the edge boundary and the vacuum vessel. The CIV profile at the O-point is simulated using a three-dimensional edge transport code of EMC3-EIRENE in which the magnetic field structure in vacuum is used for the ergodic layer. A clear discrepancy of 8 mm is found in the peak positions of CIV between measurement and simulation for magnetic configurations with thick ergodic layer, i.e., R{sub ax}=3.90 m, while only a small discrepancy of 3 mm is observed for those with relatively thin ergodic layer, i.e., R{sub ax} = 3.75 m. It suggests that the discrepancy is caused by a modification of the magnetic filed due to the presence of plasma pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compton Profile Study of Intermetallic Ti{sub 3}Al

The Compton scattering measurement on intermetallic alloy Ti{sub 3}Al is reported in this work. The measurement is made using 59.54 keV gamma-rays from Am{sup 241} source. Theoretical calculation of Compton profile is also performed employing CRYSTAL code within the framework of density functional theory to compare with the measurement. The theoretical profile of the alloy is also synthesized following the superposition model taking the published Compton profiles of elemental solids from the APW method. The experimental study of charge transfer in the alloys has also been done by performing the experimental Compton profile measurements on Ti and Al following the superposition model and charge transfer from Al to Ti is clearly seen on the alloy formation.

36 MATERIALS SCIENCE↗

Calibrated nanoscale dopant profiling using a scanning microwave microscope

The scanning microwave microscope is used for calibrated capacitance spectroscopy and spatially resolved dopant profiling measurements. It consists of an atomic force microscope combined with a vector network analyzer operating between 1-20 GHz. On silicon semiconductor calibration samples with doping concentrations ranging from 10{sup 15} to 10{sup 20} atoms/cm{sup 3}, calibrated capacitance-voltage curves as well as derivative dC/dV curves were acquired. The change of the capacitance and the dC/dV signal is directly related to the dopant concentration allowing for quantitative dopant profiling. The method was tested on various samples with known dopant concentration and the resolution of dopant profiling determined to 20% while the absolute accuracy is within an order of magnitude. Using a modeling approach the dopant profiling calibration curves were analyzed with respect to varying tip diameter and oxide thickness allowing for improvements of the calibration accuracy. Bipolar samples were investigated and nano-scale defect structures and p-n junction interfaces imaged showing potential applications for the study of semiconductor device performance and failure analysis.

36 MATERIALS SCIENCE↗

Comparison of collisional radiative models for edge electron density reconstruction from Li I (2s-2p) emission profiles

Four collisional radiative models (CRMs) for reconstruction of the edge electron density profile from the measured Li I (2s-2p) emission profile of an accelerated lithium beam are compared using experimental data from DIII-D. It is shown for both L- and H-mode plasmas that edge density profiles reconstructed with the CRMs DDD2, ABSOLUT, [Sasaki et al. Rev. Sci. Instrum. 64, 1699 (1993)] and a new model developed at DIII-D agree in a density scan from n{sub e}{sup ped}= (2.0-6.5) Multiplication-Sign 10{sup 19} m{sup -3} within 20%, 20%, <5%, and 40%, respectively, of the pedestal density measured with Thomson scattering. Profile shape and absolute density vary in a scan of the effective ion charge Z{sub eff}= 1-6 up to a factor of two but agree with Thomson data for Z{sub eff}= 1-2 within the error bars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The q-profile effect on high-order harmonic q = 1 tearing mode generation during sawtooth crashes

The effect of q-profiles on the excitation of high-order harmonic q=1 tearing modes during sawtooth crashes is investigated by a collisionless fluid model with the electron inertia term in Ohm's law. It is found that for a flat q-profile in the core region, the high-order harmonics, such as m/n=2/2 and/or m/n=3/3 modes, comparable to or stronger than the m/n=1/1 component, can be excited during tokamak sawteeth. The stronger the magnetic shear on the q=1 surface is, the more unstable the higher-m modes are. For smoothly monotonously increased q-profiles, a lower q value on the plasma edge tends to easily excite higher-m harmonics at the same level as the m = 1 mode simultaneously. The spatial characteristics of the eigenmodes in the cases with the typical q-profiles are also discussed. In addition, the basic feature of the magnetic island structures in the nonlinear evolution is numerically obtained, which is consistent qualitatively with the experimentally reconstructed phenomenon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radial profile measurement of electron temperature in edge stochastic magnetic field layer of LHD using intensity ratio of extreme ultraviolet line emissions

Vertical profile of neon line emissions in 30-650 A wavelength range has been observed in horizontally elongated plasma cross section of Large Helical Device (LHD). Intensity ratio between the neon line emissions is studied to measure the radial profile of electron temperature in the edge stochastic magnetic field layer of LHD. The edge temperature profile successfully obtained from the line ratio of NeVIII 2s-3p to 2p-3s transitions is compared with the simulation based on three-dimensional edge transport code. The result shows a reasonably good agreement with the edge temperature profile analyzed from atomic data and analysis structure code. The electron temperature at last closed flux surface measured from the intensity ratio is also in good agreement with that measured from Thomson scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of ionization and electron drift velocity profile to Rayleigh instability in a Hall thruster plasma

Role of ionization to Rayleigh instability is clarified in a Hall thruster plasma under the variety of profiles of electron drift velocity, namely, step-like profile (SLP) and two different super-Gaussian profiles (SGP1 and SGP2). For this, a relevant Rayleigh equation is derived and solved numerically using fourth-order Runge-Kutta method. Interestingly, an upper cutoff frequency of oscillations {omega}{sub max} is realized for the occurrence of the instability that shows dependence on the ionization rate {alpha}, electron drift velocity u{sub 0}, electron cyclotron frequency {Omega}, azimuthal wave number k{sub y}, plasma density n{sub 0}, density gradient {partial_derivative}n{sub 0}/{partial_derivative}x, ion (electron) thermal speed V{sub thI}(V{sub thE}), and ion (electron) plasma frequency {omega}{sub pi}({omega}{sub pe}). The frequency {omega}{sub max} follows the trend {omega}{sub max} (for SGP2) >{omega}{sub max} (for SLP) >{omega}{sub max} (for SGP1) and shows a similar behaviour with ionization for all types of the velocity profiles. The instability is found to grow faster for the higher {alpha} and the ion temperature but it acquires lower rate under the effect of the higher electron temperature; the perturbed potential also varies in accordance with the growth rate. The electron temperature influences the growth rate and cutoff frequency less significantly in comparison with the ion temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of neutral density profiles using a deuterium Balmer-alpha diagnostic in the C-2 FRC plasma

In C-2 field-reversed configuration (FRC) device, low neutral density outside the FRC separatrix is required to minimize the charge exchange loss of fast particles. Titanium gettering is used in C-2 to reduce the wall recycling and keep the neutral density low in plasma edge. The measurements of neutral density radial profile are desirable to understand the plasma recycling and the effects of titanium gettering. These measurements are also needed to study the interaction of neutral beams with FRC plasma and confinement of fast ions. Diagnostic based on absolute deuterium Balmer-alpha (D-alpha) radiation measurements is developed and deployed on C-2 device to measure the radial profile of neutral density. Simultaneous measurements of electron density and temperature are done using CO{sub 2} interferometer, Thomson scattering, and triple probes diagnostics along with absolute D-alpha radiation. Abel inversion was performed to get the time dependent radial profile of the local D-alpha emission density. Neutral density profiles are obtained under different machine conditions of titanium deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stationary self-focusing of intense laser beam in cold quantum plasma using ramp density profile

By using a transient density profile, we have demonstrated stationary self-focusing of an electromagnetic Gaussian beam in cold quantum plasma. The paper is devoted to the prospects of using upward increasing ramp density profile of an inhomogeneous nonlinear medium with quantum effects in self-focusing mechanism of high intense laser beam. We have found that the upward ramp density profile in addition to quantum effects causes much higher oscillation and better focusing of laser beam in cold quantum plasma in comparison to that in the classical relativistic case. Our computational results reveal the importance and influence of formation of electron density profiles in enhancing laser self-focusing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of the effect of bilayer membrane structures and fluctuation amplitudes on SANS/SAXS profile for short membrane wavelength

The effect of bilayer membrane structures and fluctuation amplitudes on small angle neutron scattering (SANS) and small angle X-ray scattering (SAXS) profile is investigated based on harmonic motions of the surfactant bilayers with bending as well as thickness fluctuation motions. In this study we consider the case in which the wavelength of the bilayer membrane is shorter than the thickness of the membrane. We find that the thickness of the surfactant bilayer membrane, d{sub m}, affects both q{sub dip} and q{sub peak} of I(q,0) profile, and that the fluctuation amplitude, a, of the membrane changes the peak of I(q,0). A simple formula is derived to estimate the thickness of the bilayer based on the q{sub dip} of the profile obtained from the simulation. The resulting estimates of the thickness of the bilayer with harmonic motion showed accuracy within 1%. Moreover, the bilayer thicknesses estimated from the proposed formula show an excellent agreement with the SANS and SAXS experimental results available in the literatures. We also propose a curve fit model, which describes the relationship between the fluctuation amplitude and the normalized q{sub peak} ratio. The present results show the feasibility of the simple formula to estimate the fluctuation amplitude based on the SANS and SAXS profiles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of frequency modulated continuous wave reflectometer for electron density profile measurement on the HL-2A tokamak

The frequency modulated continuous wave reflectometer was developed for the first time on the HL-2A tokamak. The system utilizes a voltage controlled oscillator and an active multiplier for broadband coverage and detects as heterodyne mode. Three reflectometers have been installed and operated in extraordinary mode polarization on HL-2A to measure density profiles at low field side, covering the Q-band (33–50 GHz), V-band (50–75 GHz), and W-band (75–110 GHz). For density profile reconstruction from the phase shift of the probing wave, a corrected phase unwrapping method is introduced in this article. The effectiveness of the method is demonstrated. The density profile behavior of a fast plasma event is presented and it demonstrates the capability of the reflectometer. These diagnostics will be contributed to the routine density profile measurements and the plasma physics study on HL-2A.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron-beam induced variation of surface profile in amorphous As{sub 20}Se{sub 80} films

Unusual profile variation of holographic surface relief gratings is detected in thin (2 μm) As{sub 20}Se{sub 80} chalcogenide films under e-beam irradiation: gratings of small periods were smoothed, whereas the gratings of larger periods increased their amplitudes. Irradiation was carried out in SEM, with 20 kV voltage and 8 nA current; the profiles of the irradiated areas were analyzed both by AFM and SEM. It is found that the kinetics of both flattening and growth followed by exponential law and took place due to lateral mass transport accelerated by e-irradiation. It is shown that the profile variation is mainly caused by competition between capillary forces and “chemical” forces induced by broken and deformed atomic bonds under e-beam irradiation. The kinetics of profile variation was calculated assuming that the mechanism of e-beam induced mass transfer is volume diffusion. The diffusion coefficients were estimated from the experimental data using theoretical expressions derived.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observed damage during Argon gas cluster depth profiles of compound semiconductors

Argon Gas Cluster Ion Beam (GCIB) sources have become very popular in XPS and SIMS in recent years, due to the minimal chemical damage they introduce in the depth-profiling of polymer and other organic materials. These GCIB sources are therefore particularly useful for depth-profiling polymer and organic materials, but also (though more slowly) the surfaces of inorganic materials such as semiconductors, due to the lower roughness expected in cluster ion sputtering compared to that introduced by monatomic ions. We have examined experimentally a set of five compound semiconductors, cadmium telluride (CdTe), gallium arsenide (GaAs), gallium phosphide (GaP), indium arsenide (InAs), and zinc selenide (ZnSe) and a high-κ dielectric material, hafnium oxide (HfO), in their response to argon cluster profiling. An experimentally determined HfO etch rate of 0.025 nm/min (3.95 × 10{sup −2} amu/atom in ion) for 6 keV Ar gas clusters is used in the depth scale conversion for the profiles of the semiconductor materials. The assumption has been that, since the damage introduced into polymer materials is low, even though sputter yields are high, then there is little likelihood of damaging inorganic materials at all with cluster ions. This seems true in most cases; however, in this work, we report for the first time that this damage can in fact be very significant in the case of InAs, causing the formation of metallic indium that is readily visible even to the naked eye.

36 MATERIALS SCIENCE↗

Measuring the depth profiles of strain/composition in AlGaN-graded layer by high-resolution x-ray diffraction

Here, we demonstrate X-ray fitting through kinematical simulations of the intensity profiles of symmetric reflections for epitaxial compositionally graded layers of AlGaN grown by molecular beam epitaxy pseudomorphically on [0001]-oriented GaN substrates. These detailed simulations depict obvious differences between changes in thickness, maximum concentration, and concentration profile of the graded layers. Through comparison of these simulations with as-grown samples, we can reliably determine these parameters, most important of which are the profiles of the concentration and strain which determine much of the electrical properties of the film. In addition to learning about these parameters for the characterization of thin film properties, these fitting techniques create opportunities to calibrate growth rates and control composition profiles of AlGaN layers with a single growth rather than multiple growths as has been done traditionally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of Compton profiles of molecular methane and ethane

The Compton profiles of methane and ethane molecules have been determined at an incident photon energy of 20 keV based on the third generation synchrotron radiation, and the statistical accuracy of 0.2% is achieved near p{sub z} = 0. The density functional theory with aug-cc-pVTZ basis set was used to calculate the Compton profiles of methane and ethane. The present experimental Compton profiles are in better agreement with the theoretical calculations in the whole p{sub z} region than the previous experimental results, which indicates that the present experimental Compton profiles are accurate enough to serve as the benchmark data for methane and ethane molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Profile measurements in the plasma edge of mega amp spherical tokamak using a ball pen probe

The ball pen probe (BPP) technique is used successfully to make profile measurements of plasma potential, electron temperature, and radial electric field on the Mega Amp Spherical Tokamak. The potential profile measured by the BPP is shown to significantly differ from the floating potential both in polarity and profile shape. By combining the BPP potential and the floating potential, the electron temperature can be measured, which is compared with the Thomson scattering (TS) diagnostic. Excellent agreement between the two diagnostics is obtained when secondary electron emission is accounted for in the floating potential. From the BPP profile, an estimate of the radial electric field is extracted which is shown to be of the order ∼1 kV/m and increases with plasma current. Corrections to the BPP measurement, constrained by the TS comparison, introduce uncertainty into the E{sub R} measurements. The uncertainty is most significant in the electric field well inside the separatrix. The electric field is used to estimate toroidal and poloidal rotation velocities from E × B motion. This paper further demonstrates the ability of the ball pen probe to make valuable and important measurements in the boundary plasma of a tokamak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bootstrap performance profiles in stochastic algorithms assessment

Optimization with stochastic algorithms has become a relevant research field. Due to its stochastic nature, its assessment is not straightforward and involves integrating accuracy and precision. Performance profiles for the mean do not show the trade-off between accuracy and precision, and parametric stochastic profiles require strong distributional assumptions and are limited to the mean performance for a large number of runs. In this work, bootstrap performance profiles are used to compare stochastic algorithms for different statistics. This technique allows the estimation of the sampling distribution of almost any statistic even with small samples. Multiple comparison profiles are presented for more than two algorithms. The advantages and drawbacks of each assessment methodology are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗