Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pointing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

An Assessment of the Drag Models in the Case of a Shock Interacting With a Fixed Bed of Point Particles

Abstract In this work, three-dimensional Euler–Lagrange (EL) point-particle simulations of a shock wave interacting with a fixed bed of particles are carried out. The results from the particle-resolved (PR) simulations are used to assess the performance of the point-particle drag models during short time scales. We demonstrate that in a one-way coupled regime, the point-particle simulations recover the dominant gas dynamic features of the flow and are in a good agreement with the exact Riemann solution of a shock traveling through a sudden area contraction. Although the PR simulations are inviscid, we show that a dissipative drag is necessary to predict the mean behavior of the gas. As a model for the inviscid shock-induced (SI) drag two different models are presented in lieu of the quasi-steady drag. Finally, two-way coupled simulations are performed at four different particle volume fractions {0.10, 0.15, 0.20, 0.25} and three different incident shock Mach numbers {1.22, 1.66, 3.0} and compared against the data from PR inviscid simulations. At a lower Mach number (1.22), averaged flow quantities from the two-way coupled simulations agree well with the PR simulations. As the Mach number increases, we observe that the discrepancies between the point-particle and the PR simulations grow. A sensitivity analysis of the drag models involved reveals a strong influence of the inviscid-unsteady force on the gas quantities especially in the case of a strong shock interacting with a dense bed of particles. The use of Mach correlation beyond the subcritical regime coupled with the model for volume fraction correction is identified as a probable cause for the additional drag.

Engineering↗

Investigation of an implantable dosimeter for single-point water equivalent path length verification in proton therapy

Purpose: In vivo range verification in proton therapy is highly desirable. A recent study suggested that it was feasible to use point dose measurement for in vivo beam range verification in proton therapy, provided that the spread-out Bragg peak dose distribution is delivered in a different and rather unconventional manner. In this work, the authors investigate the possibility of using a commercial implantable dosimeter with wireless reading for this particular application. Methods: The traditional proton treatment technique delivers all the Bragg peaks required for a SOBP field in a single sequence, producing a constant dose plateau across the target volume. As a result, a point dose measurement anywhere in the target volume will produce the same value, thus providing no information regarding the water equivalent path length to the point of measurement. However, the same constant dose distribution can be achieved by splitting the field into a complementary pair of subfields, producing two oppositely ''sloped'' depth-dose distributions, respectively. The ratio between the two distributions can be a sensitive function of depth and measuring this ratio at a point inside the target volume can provide the water equivalent path length to the dosimeter location. Two types of field splits were used in the experiment, one achieved by the technique of beam current modulation and the other by manipulating the location and width of the beam pulse relative to the range modulator track. Eight MOSFET-based implantable dosimeters at four different depths in a water tank were used to measure the dose ratios for these field pairs. A method was developed to correct the effect of the well-known LET dependence of the MOSFET detectors on the depth-dose distributions using the columnar recombination model. The LET-corrected dose ratios were used to derive the water equivalent path lengths to the dosimeter locations to be compared to physical measurements. Results: The implantable dosimeters measured the dose ratios with a reasonable relative uncertainty of 1%-3% at all depths, except when the ratio itself becomes very small. In total, 55% of the individual measurements reproduced the water equivalent path lengths to the dosimeters within 1 mm. For three dosimeters, the difference was consistently less than 1 mm. Half of the standard deviations over the repeated measurements were equal or less than 1 mm. Conclusions: With a single fitting parameter, the LET-correction method worked remarkably well for the MOSFET detectors. The overall results were very encouraging for a potential method of in vivo beam range verification with millimeter accuracy. This is sufficient accuracy to expand range of clinical applications in which the authors could use the distal fall off of the proton depth dose for tight margins.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-QI-15: Single Point Dosimetry by Means of Cerenkov Radiation Energy Transfer (CRET)

Purpose: Cerenkov light is generated when a charged particles with energy greater then 250 keV, moves faster than the speed of light in a given medium. Both x-ray photons and electrons produce optical Cerenkov photons during the static megavoltage linear accelerator (LINAC) operational mode. Recently, Cerenkov radiation gained considerable interest as possible candidate as a new imaging modality. Optical signals generated by Cerenkov radiation may act as a surrogate for the absorbed superficial radiation dose. We demonstrated a novel single point dosimetry method for megavoltage photon and electron therapy utilizing down conversion of Cerenkov photons. Methods: The custom build signal characterization system was used: a sample holder (probe) with adjacent light tight compartments was connected via fiber-optic cables to a photon counting photomultiplier tube (PMT). One compartment contains a medium only while the other contains medium and red-shifting nano-particles (Q-dots, nanoclusters). By taking the difference between the two signals (Cerenkov photons and CRET photons) we obtain a measure of the down-converted light, which we expect to be proportional to dose as measured with an adjacent ion chamber. Experimental results are compared to Monte Carlo simulations performed using the GEANT4 code. Results: The signal correlation between CR signal, CRET readings and dose produced by LINAC at a single point were investigated. The experimental results were compared with simulations. The dose linearity, signal to noise ratio and dose rate dependence were tested with custom build CRET based probe. Conclusion: Performance characteristics of the proposed single point CRET based probe were evaluated. The direct use of the induced Cerenkov emission and CRET in an irradiated single point volume as an indirect surrogate for the imparted dose was investigated. We conclude that CRET is a promising optical based dosimetry method that offers advantages over those already proposed.

60 APPLIED LIFE SCIENCES↗

Sci—Thur AM: YIS - 11: Estimation of Bladder-Wall Cumulative Dose in Multi-Fraction Image-Based Gynaecological Brachytherapy Using Deformable Point Set Registration

Dosimetric parameters based on dose-volume histograms (DVH) of contoured structures are routinely used to evaluate dose delivered to target structures and organs at risk. However, the DVH provides no information on the spatial distribution of the dose in situations of repeated fractions with changes in organ shape or size. The aim of this research was to develop methods to more accurately determine geometrically localized, cumulative dose to the bladder wall in intracavitary brachytherapy for cervical cancer. The CT scans and treatment plans of 20 cervical cancer patients were used. Each patient was treated with five high-dose-rate (HDR) brachytherapy fractions of 600cGy prescribed dose. The bladder inner and outer surfaces were delineated using MIM Maestro software (MIM Software Inc.) and were imported into MATLAB (MathWorks) as 3-dimensional point clouds constituting the “bladder wall”. A point-set registration toolbox for MATLAB, Coherent Point Drift (CPD), was used to non-rigidly transform the bladder-wall points from four of the fractions to the coordinate system of the remaining (reference) fraction, which was chosen to be the emptiest bladder for each patient. The doses were accumulated on the reference fraction and new cumulative dosimetric parameters were calculated. The LENT-SOMA toxicity scores of these patients were studied against the cumulative dose parameters. Based on this study, there was no significant correlation between the toxicity scores and the determined cumulative dose parameters.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-04: Comparison of Shallow Fluence to Deep Point Dose Measurements for Spine VMAT SBRT Patient-Specific QA

Purpose: To investigate the sensitivity of traditional gamma-index-based fluence measurements for patient-specific measurements in VMAT delivered spine SBRT. Methods: The ten most recent cases for spine SBRT were selected. All cases were planned with Eclipse RapidArc for a TrueBeam STx. The delivery was verified using a point dose measurement with a Pinpoint 3D micro-ion chamber in a Standard Imaging Stereotactic Dose Verification Phantom. Two points were selected for each case, one within the target in a low dose-gradient region and one in the spinal cord. Measurements were localized using on-board CBCT. Cumulative and separate arc measurements were acquired with the ArcCheck and assessed using the SNC patient software with a 3%/3mm and 2%/2mm gamma analysis with global normalization and a 10% dose threshold. Correlations between data were determined using the Pearson Product-Moment Correlation. Results: For our cohort of patients, the measured doses were higher than calculated ranging from 2.2%–9.7% for the target and 1.0%–8.2% for the spinal cord. There was strong correlation between 3%/3mm and 2%/2mm passing rates (r=0.91). Moderate correlation was found between target and cord dose with a weak fit (r=0.67, R-Square=0.45). The cumulative ArcCheck measurements showed poor correlation with the measured point doses for both the target and cord (r=0.20, r=0.35). If the arcs are assessed separately with an acceptance criteria applied to the minimum passing rate between all arcs, a moderate negative correlation was found for the target and cord (r=−0.48, r= −0.71). The case with the highest dose difference (9.7%) received a passing rate of 97.2% for the cumulative arcs and 87.8% for the minimum with separate arcs. Conclusion: Our data suggest that traditional passing criteria using ArcCheck with cumulative measurements do not correlate well with dose errors. Separate arc analysis shows better correlation but may still miss large dose errors. Point dose verifications are recommended.

60 APPLIED LIFE SCIENCES↗

SU-E-T-56: A Novel Approach to Computing Expected Value and Variance of Point Dose From Non-Gated Radiotherapy Delivery

Purpose: Randomness in patient internal organ motion phase at the beginning of non-gated radiotherapy delivery may introduce uncertainty to dose received by the patient. Concerns of this dose deviation from the planned one has motivated many researchers to study this phenomenon although unified theoretical framework for computing it is still missing. This study was conducted to develop such framework for analyzing the effect. Methods: Two reasonable assumptions were made: a) patient internal organ motion is stationary and periodic; b) no special arrangement is made to start a non -gated radiotherapy delivery at any specific phase of patient internal organ motion. A statistical ensemble was formed consisting of patient’s non-gated radiotherapy deliveries at all equally possible initial organ motion phases. To characterize the patient received dose, statistical ensemble average method is employed to derive formulae for two variables: expected value and variance of dose received by a patient internal point from a non-gated radiotherapy delivery. Fourier Series was utilized to facilitate our analysis. Results: According to our formulae, the two variables can be computed from non-gated radiotherapy generated dose rate time sequences at the point’s corresponding locations on fixed phase 3D CT images sampled evenly in time over one patient internal organ motion period. The expected value of point dose is simply the average of the doses to the point’s corresponding locations on the fixed phase CT images. The variance can be determined by time integration in terms of Fourier Series coefficients of the dose rate time sequences on the same fixed phase 3D CT images. Conclusion: Given a non-gated radiotherapy delivery plan and patient’s 4D CT study, our novel approach can predict the expected value and variance of patient radiation dose. We expect it to play a significant role in determining both quality and robustness of patient non-gated radiotherapy plan.

60 APPLIED LIFE SCIENCES↗

Critical points of metal vapors

A new method is proposed for calculating the parameters of critical points and binodals for the vapor–liquid (insulator–metal) phase transition in vapors of metals with multielectron valence shells. The method is based on a model developed earlier for the vapors of alkali metals, atomic hydrogen, and exciton gas, proceeding from the assumption that the cohesion determining the basic characteristics of metals under normal conditions is also responsible for their properties in the vicinity of the critical point. It is proposed to calculate the cohesion of multielectron atoms using well-known scaling relations for the binding energy, which are constructed for most metals in the periodic table by processing the results of many numerical calculations. The adopted model allows the parameters of critical points and binodals for the vapor–liquid phase transition in metal vapors to be calculated using published data on the properties of metals under normal conditions. The parameters of critical points have been calculated for a large number of metals and show satisfactory agreement with experimental data for alkali metals and with available estimates for all other metals. Binodals of metals have been calculated for the first time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Algorithms for Efficient Reproducible Floating Point Summation

We define “reproducibility” as getting bitwise identical results from multiple runs of the same program, perhaps with different hardware resources or other changes that should not affect the answer. Many users depend on reproducibility for debugging or correctness. However, dynamic scheduling of parallel computing resources, combined with nonassociative floating point addition, makes reproducibility challenging even for summation, or operations like the BLAS. We describe a “reproducible accumulator” data structure (the “binned number”) and associated algorithms to reproducibly sum binary floating point numbers, independent of summation order. We use a subset of the IEEE Floating Point Standard 754-2008 and bitwise operations on the standard representations in memory. Our approach requires only one read-only pass over the data, and one reduction in parallel, using a 6-word reproducible accumulator (more words can be used for higher accuracy), enabling standard tiling optimization techniques. Summing n words with a 6-word reproducible accumulator requires approximately 9 n floating point operations (arithmetic, comparison, and absolute value) and approximately 3 n bitwise operations. The final error bound with a 6-word reproducible accumulator and our default settings can be up to 2 29 times smaller than the error bound for conventional (recursive) summation on ill-conditioned double-precision inputs.

Computer Science↗

Point Source Likelihood Framework (psl) v1.0

PSL is a software framework for localizing radiation point sources in a 3D environment using a freely moving radiation detector system. The framework assumes a single point source of radiation is in the environment and uses known detector positions and orientations along with their radiation measurements to find the most likely location of the point source. This approach to the problem enables analyses that improve upon the capability of a standard Maximum Likelihood Expectation Maximization (MLEM) approach, such as setting a source detection threshold, finding a likelihood interval for the position of the source, finding a likelihood interval for the activity (intensity) of the source, determining whether more than one point source may be present, and generating a map of Minimum Detectable Activity (MDA) for a given source type. Applications include radiological and nuclear security, consequence management, decontamination and decommissioning of nuclear facilities, and radiological emergency response.

Joshi, Tenzing↗

An Updated Synthesis of the Projectile Point Typology and Chronology of Eastern Idaho

The eastern Idaho archaeological record is a unique confluence of the Great Basin, Columbia Plateau, and Great Plains, resulting in a diverse and complex projectile point sequence. This study presents a revised typology and chronology of projectile points in the region, grounded in a comprehensive review of over 750 diagnostic examples from 16 stratified sites and 110 associated radiocarbon dates. We reevaluate existing classifications and propose a revised chronological framework with regionally appropriate types. This study provides a thorough background to eastern Idaho projectile points and contributes to broader discussions of projectile point typology and chronology in the Desert West, offering a robust tool for future archaeological research in the region.

99 - GENERAL AND MISCELLANEOUS↗

Leiomodin creates a leaky cap at the pointed end of actin-thin filaments

Improper lengths of actin-thin filaments are associated with altered contractile activity and lethal myopathies. Leiomodin, a member of the tropomodulin family of proteins, is critical in thin filament assembly and maintenance; however, its role is under dispute. Using nuclear magnetic resonance data and molecular dynamics simulations, we generated the first atomic structural model of the binding interface between the tropomyosin-binding site of cardiac leiomodin and the N-terminus of striated muscle tropomyosin. Our structural data indicate that the leiomodin/tropomyosin complex only forms at the pointed end of thin filaments, where the tropomyosin N-terminus is not blocked by an adjacent tropomyosin protomer. This discovery provides evidence supporting the debated mechanism where leiomodin and tropomodulin regulate thin filament lengths by competing for thin filament binding. Data from experiments performed in cardiomyocytes provide additional support for the competition model; specifically, expression of a leiomodin mutant that is unable to interact with tropomyosin fails to displace tropomodulin at thin filament pointed ends and fails to elongate thin filaments. Together with previous structural and biochemical data, we now propose a molecular mechanism of actin polymerization at the pointed end in the presence of bound leiomodin. In the proposed model, the N-terminal actin-binding site of leiomodin can act as a “swinging gate” allowing limited actin polymerization, thus making leiomodin a leaky pointed-end cap. Results presented in this work answer long-standing questions about the role of leiomodin in thin filament length regulation and maintenance.

2D-NMR↗

Draft report on melt point as a function of composition for urania-based systems

This report documents the testing of a urania (UO 2.00 ) sample as a baseline and the attempt to determine the melt point associated with 4 compositions of urania-ceria and urania-neodymia pseudo binaries provided by ORNL, with compositions of 95/5, and 80/20 and of (U/Ce)O 2.00 and (U/Nd)O 2.00 in the newly developed ceramic melt point determination system. A redesign of the system using parts fabricated from tungsten was undertaken in order to help prevent contamination and tungsten carbide formation in the crucibles. The previously developed system employed mostly graphite parts that were shown to react with the sample containment black-body crucible leading to unstable temperature readings and crucible failure, thus the redesign. Measured melt point values of UO 2.00 and U 0.95 Ce 0.05 O 2.00 , U 0.80 Ce 0.20 O 2.00 , U 0.95 Nd 0.05 O 2.00 and U 0.80 Nd 0.20 O 2.00 were measured using a 2-color pyrometer. The value measured for UO 2.00 was consistent with the published accepted value 2845°C±25°C, although a wide range of values has been published by researchers and will be discussed later in the text. For comparison, values obtained from a published binary phase diagram of UO 2 -Nd 2 O 3 were used for comparison with our measure values. No literature melt point values for comparison with the measurements performed in this study were found for (U/Ce)O 2.00 in our stoichiometry range.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mapping Correlation of a Simulated Dark Matter Source and a Point Source in the Gamma-Ray Sky - Oral Presentation [Slides]

In my research, I analyzed how two gamma-ray source models interact with one another when optimizing to fit data. This is important because it becomes hard to distinguish between the two point sources when they are close together or looking at low energy photons. The reason for the first is obvious, the reason why they become harder to distinguish at lower photon energies is the resolving power of the Fermi Gamma-Ray Space Telescope gets worse at lower energies. When the two point sources are highly correlated (hard to distinguish between), we need to change our method of statistical analysis. What I did was show that highly correlated sources have larger uncertainties associated with them, caused by an optimizer not knowing which point source’s parameters to optimize. I also mapped out where their is high correlation for 2 different theoretical mass dark matter point sources so that people analyzing them in the future knew where they had to use more sophisticated statistical analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Critical point calculations of BSE and SiO 2

Included in this memo are the final values for the BSE and SiO 2 critical points. VASP 5.3.3 was used to calculate the values in each table. Standard methodology is to continue equilibrating the simulation until the block averaged standard deviation is less than 1%. However, due to the simulation sizes in these simulations, the average standard deviation of the BSE pressure is 5% (ranging between 2% and 7%, which is much higher than the usual under 1% considered acceptable) and the SiO 2 pressure is 6% with the lower density error bars being significantly larger than the highest density. The critical point is chosen where the dP/dρ >= 0 for an entire isotherm but is often difficult to distinguish because of the noise along each isotherm. As such, the actual values of the critical points are found by “best guess”. Further computer simulations creating a more pressure values along each isotherm would help but time constraints preclude this. Similarly, the ability to calculate pressures at lower densities that are currently feasible with VASP would also make determination of the critical point easier.

36 MATERIALS SCIENCE↗

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle—Pacific Northwest Division operates numerous research and development laboratories in Richland, Washington, including those associated with the Pacific Northwest National Laboratory (PNNL) on the Department of Energy’s Hanford Site that have the potential for radionuclide air emissions. The National Emission Standard for Hazardous Air Pollutants (NESHAP 40 CFR 61, Subparts H and I) requires an assessment of all effluent release points that have the potential for radionuclide emissions. Potential emissions are assessed annually. Sampling, monitoring, and other regulatory compliance requirements are designated based upon the potential-to-emit dose criteria found in the regulations. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission point system performance, operation, and design information. A description of the buildings, exhaust points, control technologies, and sample extraction details is provided for each registered or deregistered facility emission point. Additionally, applicable stack sampler configuration drawings, figures, and photographs are provided.

radionuclide air emission↗

Magnetic Field Reconstruction for a Realistic Multi-Point, Multi-Scale Spacecraft Observatory

Future in situ space plasma investigations will likely involve spatially distributed observatories comprised of multiple spacecraft, beyond the four and five spacecraft configurations currently in operation. Inferring the magnetic field structure across the observatory, and not simply at the observation points, is a necessary step towards characterizing fundamental plasma processes using these unique multi-point, multi-scale data sets. We propose improvements upon the classic first-order reconstruction method, as well as a second-order method, utilizing magnetometer measurements from a realistic nine-spacecraft observatory. The improved first-order method, which averages over select ensembles of four spacecraft, reconstructs the magnetic field associated with simple current sheets and numerical simulations of turbulence accurately over larger volumes compared to second-order methods or first-order methods using a single regular tetrahedron. Using this averaging method on data sets with fewer than nine measurement points, the volume of accurate reconstruction compared to a known magnetic vector field improves approximately linearly with the number of measurement points.

79 ASTRONOMY AND ASTROPHYSICS↗

3D Measurement Simulation and Relative Pointing Error Verification of the Telescope Mount Assembly Subsystem for the Large Synoptic Survey Telescope

An engineering validation of a large optical telescope consists of executing major performing tests at the subsystem level to verify the overall engineering performance of the observatory. Thus, the relative pointing error verification of the telescope mount assembly subsystem is of special interest to guarantee the absolute pointing performance of the large synoptic survey telescope. This paper presents a new verification method for the relative pointing error assessment of the telescope mount assembly, based on laser tracker technology and several fiducial points fixed to the floor. Monte-Carlo-based simulation results show that the presented methodology is fit for purpose, even if floor movement occurs due to temperature variation during the measurement acquisition process. A further research about laser tracker technology integration into the telescope structure may suggest that such laser tracker technology could be permanently installed in the telescope in order to provide an active alignment system that aims to detect and correct possible misalignment between mirrors or to provide the required mirror positioning verification accuracy after maintenance activities. The obtained results show that two on-board laser tracker systems combined with eight measurement targets could result in measurement uncertainties that are better than 1 arcsec, which would provide a reliable built-in metrology tool for large telescopes.

47 OTHER INSTRUMENTATION↗

Application of Sapphire-Fiber-Bragg-Grating-Based Multi-Point Temperature Sensor in Boilers at a Commercial Power Plant

Readily available temperature sensing in boilers is necessary to improve efficiencies, minimize downtime, and reduce toxic emissions for a power plant. The current techniques are typically deployed as a single-point measurement and are primarily used for detection and prevention of catastrophic events due to the harsh environment. In this work, a multi-point temperature sensor based on wavelength-multiplexed sapphire fiber Bragg gratings (SFBGs) were fabricated via the point-by-point method with a femtosecond laser. The sensor was packaged and calibrated in the lab, including thermally equilibrating at 1200 °C, followed by a 110-h, 1000 °C stability test. After laboratory testing, the sensor system was deployed in both a commercial coal-fired and a gas-fired boiler for 42 days and 48 days, respectively. The performance of the sensor was consistent during the entire test duration, over the course of which it measured temperatures up to 950 °C (with some excursions over 1000 °C), showing the survivability of the sensor in a field environment. The sensor has a demonstrated measurement range from room temperature to 1200 °C, but the maximum temperature limit is expected to be up to 1900 °C, based on previous work with other sapphire based temperature sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗