Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

High-throughput full-automatic synchrotron-based tomographic microscopy

At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 {micro}m to 7.4 {micro}m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 {micro}m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

43 PARTICLE ACCELERATORS↗

A CATALOG OF METHANOL MASERS IN MASSIVE STAR-FORMING REGIONS. III. THE MOLECULAR OUTFLOW SAMPLE

We present an interferometric survey of the 44 GHz class I methanol maser transition toward a sample of 69 sources consisting of high-mass protostellar object (HMPO) candidates and ultracompact (UC) H ii regions. We found a 38% detection rate (16 of 42) in the HMPO candidates and a 54% detection rate (13 of 24) for the regions with ionized gas. This result indicates that class I methanol maser emission is more common toward the more evolved young stellar objects of our sample. Comparing with similar interferometric data sets, our observations show narrower linewidths, likely due to our higher spatial resolution. Based on a comparison between molecular outflow tracers and the maser positions, we find several cases where the masers appear to be located at the outflow interface with the surrounding core. Unlike previous surveys, we also find several cases where the masers appear to be located close to the base of the molecular outflow, although we cannot discard projection effects. This and other surveys of class I methanol masers not only suggest that these masers may trace shocks at different stages, but also that they may even trace shocks arising from a number of different phenomena occurring in star-forming regions: young/old outflows, cloud–cloud collisions, expanding H ii regions, among others.

79 ASTRONOMY AND ASTROPHYSICS↗

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

43 PARTICLE ACCELERATORS↗

High-resolution reflecting time-of-flight momentum and energy mapping system

A new system to map electron momentum and energy is proposed. A reflecting electrode is introduced into a time-of-flight (TOF) system whose decelerating electric field sends all the electrons back to a position-sensitive detector close to but behind the source of the electrons. The longer flying distance that results makes it possible to significantly improve the energy-resolved performance, especially in the higher energy region. The dependence of the new TOF system on its characteristic parameters is analyzed, along with its application to attosecond streak cameras. Experimental results verified a relative energy resolution better than 0.2 eV for 22 eV electrons and also revealed the availability of the improved relative energy resolution smaller than 1.0% for electron energy ranging from 30 to 40 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE ARIZONA RADIO OBSERVATORY CO MAPPING SURVEY OF GALACTIC MOLECULAR CLOUDS. IV. THE NGC 1333 CLOUD IN PERSEUS IN CO J = 2-1 AND {sup 13}CO J = 2-1

We mapped the NGC 1333 section of the Perseus Molecular Cloud in the J = 2-1 emission lines of {sup 12}CO and {sup 13}CO over a 50' × 60' region (3.4 × 4.1 pc at the cloud distance of 235 pc), using the Arizona Radio Observatory Heinrich Hertz Submillimeter Telescope. The angular resolution is 38'' (0.04 pc) and velocity resolution is 0.3 km s{sup –1}. We compare our velocity moment maps with known positions of young stellar objects (YSOs) and (sub)millimeter dust continuum emission. The CO emission is brightest at the center of the cluster of YSOs, but is detected over the full extent of the mapped region at ≥10 × rms. The morphology of the CO channel maps shows a kinematically complex structure, with many elongated features extending from the YSO cluster outward by ∼1 pc. One notable feature appears as a narrow serpentine structure that curves and doubles back, with a total length of ∼3 pc. The {sup 13}CO velocity channel maps show evidence for many low-density cavities surrounded by partial shell-like structures, consistent with previous studies. Maps of the velocity moments show localized effects of bipolar outflows from embedded YSOs, as well as a large-scale velocity gradient around the central core of YSOs, suggestive of large-scale turbulent cloud motions determining the location of current star formation. The CO/{sup 13}CO intensity ratios show the distribution of the CO opacity, which exhibits a complex kinematic structure. Identified YSOs are located mainly at the positions of greatest CO opacity. The maps are available for download as FITS files.

79 ASTRONOMY AND ASTROPHYSICS↗

A multichannel magnetic probe system for analysing magnetic fluctuations in helical axis plasmas

The need to understand the structure of magnetic fluctuations in H-1NF heliac [S. Hamberger et al., Fusion Technol. 17, 123 (1990)] plasmas has motivated the installation of a sixteen former, tri-axis helical magnetic probe Mirnov array (HMA). The new array complements two existing poloidal Mirnov arrays by providing polarisation information, higher frequency response, and improved toroidal resolution. The helical placement is ideal for helical axis plasmas because it positions the array as close as possible to the plasma in regions of varying degrees of favourable curvature in the magnetohydrodynamic sense, but almost constant magnetic angle. This makes phase variation with probe position near linear, greatly simplifying the analysis of the data. Several of the issues involved in the design, installation, data analysis, and calibration of this unique array are presented including probe coil design, frequency response measurements, mode number identification, orientation calculations, and mapping probe coil positions to magnetic coordinates. Details of specially designed digitally programmable pre-amplifiers, which allow gains and filters to be changed as part of the data acquisition initialisation sequence and stored with the probe signals, are also presented. The low shear heliac geometry [R. Jiménez-Gómez et al., Nucl. Fusion 51, 033001 (2011)], flexibility of the H-1NF heliac, and wealth of information provided by the HMA create a unique opportunity for detailed study of Alfvén eigenmodes, which could be a serious issue for future fusion reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RADIO PULSATION SEARCH AND IMAGING STUDY OF SGR J1935+2154

We present the results obtained from imaging observations and a search for radio pulsations toward the magnetar SGR J1935+2154 made using the Giant Metrewave Radio Telescope and the Ooty Radio Telescope. We present the high-resolution radio image of the supernova remnant (SNR) G57.2+0.8, which is positionally associated with SGR J1935+2154. We did not detect significant periodic radio pulsations from the magnetar, with 8 σ upper limits on its flux density of 0.4 and 0.2 mJy at 326.5 and 610 MHz, respectively, for an assumed duty cycle of 10%. The corresponding 6 σ upper limits at the two frequencies for any burst emission with an assumed width of 10 ms are 0.5 Jy and 63 mJy, respectively. No continuum radio point source was detected at the position of SGR J1935+2154 with a 3 σ upper limit of 1.2 mJy. We also did not detect significant diffuse radio emission in a radius of 70 arc s coinciding with the recently reported diffuse X-ray emission, with a 3 σ upper limit of 4.5 mJy. Using the archival HI spectra, we estimate the distance of SNR G57.2+0.8 to be 11.7 ± 2.8 kpc. Based on the measured HI column density ( N {sub H} ) along this line of sight, we argue that the magnetar could be physically associated with SNR G57.2+0.8. Based on the present data, we cannot rule out either a pulsar wind nebula or a dust-scattering halo origin for the diffuse X-ray emission seen around the magnetar.

79 ASTRONOMY AND ASTROPHYSICS↗

Celestial amplitudes from UV to IR

Celestial amplitudes represent 4D scattering of particles in boost, rather than the usual energy-momentum, eigenstates and hence are sensitive to both UV and IR physics. We show that known UV and IR properties of quantum gravity translate into powerful constraints on the analytic structure of celestial amplitudes. For example the soft UV behavior of quantum gravity is shown to imply that the exact four-particle scattering amplitude is meromorphic in the complex boost weight plane with poles confined to even integers on the negative real axis. Would-be poles on the positive real axis from UV asymptotics are shown to be erased by a flat space analog of the AdS resolution of the bulk point singularity. The residues of the poles on the negative axis are identified with operator coefficients in the IR effective action. Far along the real positive axis, the scattering is argued to grow exponentially according to the black hole area law. Exclusive amplitudes are shown to simply factorize into conformally hard and conformally soft factors. The soft factor contains all IR divergences and is given by a celestial current algebra correlator of Goldstone bosons from spontaneously broken asymptotic symmetries. The hard factor describes the scattering of hard particles together with the boost-eigenstate clouds of soft photons or gravitons required by asymptotic symmetries. These provide an IR safe S-matrix for the scattering of hard particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Poster – 02: Positron Emission Tomography (PET) Imaging Reconstruction using higher order Scattered Photon Coincidences

PET images are affected by the presence of scattered photons. Incorrect scatter-correction may cause artifacts, particularly in 3D PET systems. Current scatter reconstruction methods do not distinguish between single and higher order scattered photons. A dual-scattered reconstruction method (GDS-MLEM) that is independent of the number of Compton scattering interactions and less sensitive to the need for high energy resolution detectors, is proposed. To avoid overcorrecting for scattered coincidences, the attenuation coefficient was calculated by integrating the differential Klein-Nishina cross-section over a restricted energy range, accounting only for scattered photons that were not detected. The optimum image can be selected by choosing an energy threshold which is the upper energy limit for the calculation of the cross-section and the lower limit for scattered photons in the reconstruction. Data was simulated using the GATE platform. 500,000 multiple scattered photon coincidences with perfect energy resolution were reconstructed using various methods. The GDS-MLEM algorithm had the highest confidence (98%) in locating the annihilation position and was capable of reconstructing the two largest hot regions. 100,000 photon coincidences, with a scatter fraction of 40%, were used to test the energy resolution dependence of different algorithms. With a 350–650 keV energy window and the restricted attenuation correction model, the GDS-MLEM algorithm was able to improve contrast recovery and reduce the noise by 7.56%–13.24% and 12.4%–24.03%, respectively. This approach is less sensitive to the energy resolution and shows promise if detector energy resolutions of 12% can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: High temporal resolution characterization of gating response time

Purpose: Low temporal latency between a gating ON/OFF signal and the LINAC beam ON/OFF during respiratory gating is critical for patient safety. Here the authors describe a novel method to precisely measure gating lag times at high temporal resolutions. Methods: A respiratory gating simulator with an oscillating platform was modified to include a linear potentiometer for position measurement. A photon diode was placed at linear accelerator isocenter for beam output measurement. The output signals of the potentiometer and diode were recorded simultaneously at 2500 Hz with an analog to digital converter for four different commercial respiratory gating systems. The ON and OFF of the beam signal were located and compared to the expected gating window for both phase and position based gating and the temporal lag times extracted. Results: For phase based gating, a real-time position management (RPM) infrared marker tracking system with a single camera and a RPM system with a stereoscopic camera were measured to have mean gate ON/OFF lag times of 98/90 and 86/44 ms, respectively. For position based gating, an AlignRT 3D surface system and a Calypso magnetic fiducial tracking system were measured to have mean gate ON/OFF lag times of 356/529 and 209/60 ms, respectively. Conclusions: Temporal resolution of the method was high enough to allow characterization of individual gate cycles and was primary limited by the sampling speed of the data recording device. Significant variation of mean gate ON/OFF lag time was found between different gating systems. For certain gating devices, individual gating cycle lag times can vary significantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gold nanocrystal labels provide a sequence–to–3D structure map in SAXS reconstructions

Small-angle x-ray scattering (SAXS) is a powerful technique to probe the structure of biological macromolecules and their complexes under virtually arbitrary solution conditions, without the need for crystallization. While it is possible to reconstruct molecular shapes from SAXS data ab initio, the resulting electron density maps have a resolution of ~1 nm and are often insufficient to reliably assign secondary structure elements or domains. We show that SAXS data of gold-labeled samples significantly enhance the information content of SAXS measurements, allowing the unambiguous assignment of macromolecular sequence motifs to specific locations within a SAXS structure. We first demonstrate our approach for site-specifically internally and end-labeled DNA and an RNA motif. In addition, we present a protocol for highly uniform and site-specific labeling of proteins with small (~1.4 nm diameter) gold particles and apply our method to the signaling protein calmodulin. In all cases, the position of the small gold probes can be reliably identified in low-resolution electron density maps. Enhancing low-resolution measurements by site-selective gold labeling provides an attractive approach to aid modeling of a large range of macromolecular systems.

Science & Technology - Other Topics↗

SU-F-J-30: Application of Intra-Fractional Imaging for Pretreatment CBCT of Breath-Hold Lung SBRT

Purpose: Clinical implementation of gated lung SBRT requires tools to verify the accuracy of the target positioning on a daily basis. This is a particular challenge on Elekta linacs where the XVI imaging system does not interface directly to any commercial gating solution. In this study, we used the Elekta’s intra-fractional imaging functionality to perform the pretreatment CBCT verifications and evaluated both the image quality and gating accuracy. Methods: To use intrafraction imaging tools for pretreatment verifications, we planned a 360-degree arc with 1mmx5mm MLC opening. This beam was designed to drive the gantry during the gated CBCT data collection. A Catphan phantom was used to evaluate the image quality for the intra-fractional CBCT. A CIRS lung phantom with a 3cm sphereinsert and a moving chest plate were programmed with a simulated breathhold breathing pattern was used to check the gating accuracy. A C-Rad CatalystHD surface mapping system was used to provide the gating signal. Results: The total delivery time of the arc was 90 seconds. The uniformity and low contrast resolution for the intra-fractional CBCT was 1.5% and 3.6%, respectively. The values for the regular CBCT were 1.7% and 2.5%, respectively. The spatial resolution was 7 line-pairs/cm and the 3D spatial integrity was less than 1mm for the intra-fractional CBCT. The gated CBCT clearly demonstrated the accuracy of the gating image acquisition. Conclusion: The intra-fraction CBCT capabilities on an Elekta linac can be used to acquire pre-treatment gated images to verify the accuracy patient positioning. This imaging capability should provide for accurate patient alignments for the delivery of lung SBRT. This research was partially supported by Elekta.

60 APPLIED LIFE SCIENCES↗

HOW DO STAR-FORMING GALAXIES AT z > 3 ASSEMBLE THEIR MASSES?

We investigate how star-forming galaxies typically assemble their masses at high redshift. Taking advantage of the deep multi-wavelength coverage of the GOODS data set, we select two of the largest samples of high-redshift star-forming galaxies based on their UV colors and measure stellar mass of individual galaxies. We use template-fitting photometry to obtain optimal estimates of the fluxes in lower-resolution ground-based and Spitzer images using prior information about galaxy positions, shapes, and orientations. By combining the data and realistic simulations to understand measurement errors and biases, we make a statistically robust determination of stellar mass function (SMF) of the UV-selected star-forming galaxies at z {approx} 4 and 5. We report a broad correlation between stellar mass and UV luminosity, such that more UV-luminous galaxies are, on average, also more massive. However, we show that the correlation has a substantial intrinsic scatter, particularly for UV-faint galaxies, evidenced by the fact there is a non-negligible number of UV faint but massive galaxies. Furthermore, we find that the low-mass end of the SMF does not rise as steeply as the UV luminosity function ({alpha}{sub UVLF} Almost-Equal-To - (1.7-1.8) while {alpha}{sub SMF} Almost-Equal-To - (1.3-1.4)) of the same galaxies. In a smooth and continuous formation scenario where star formation rates (SFRs) are sustained at the observed rates for a long time, these galaxies would have accumulated more stellar mass (by a factor of Almost-Equal-To 3) than observed and therefore the SMF would mirror more closely that of the UV luminosity function. The relatively shallow slope of the SMF is due to the fact that many of the UV-selected galaxies are not massive enough, and therefore are too faint in their rest-frame optical bands, to be detected in the current observations. Our results favor a more episodic formation history in which SFRs of low-mass galaxies vary significantly over cosmic time, a scenario currently favored by galaxy clustering. Our findings for the UV-faint galaxies at high redshift are in contrast with previous studies on more UV-luminous galaxies, which exhibit a tighter SFR-M{sub star} correlation. The discrepancy may suggest that galaxies at different luminosities may have different evolutionary paths. Such a scenario presents a nontrivial test to theoretical models of galaxy formation.

79 ASTRONOMY AND ASTROPHYSICS↗

SISGR: Atom chip microscopy: A novel probe for strongly correlated materials

Microscopy techniques co-opted from nonlinear optics and high energy physics have complemented solid-state probes in elucidating the order manifest in condensed matter materials. Up until now, however, no attempts have been made to use modern techniques of ultracold atomic physics to directly explore properties of strongly correlated or topologically protected materials. Our current program is focused on introducing a novel magnetic field microscopy technique into the toolbox of imaging probes. Our prior DOE ESPM program funded the development of a novel instrument using a dilute gas Bose-Einstein condensate (BEC) as a scanning probe capable of measuring tiny magnetic (and electric) DC and AC fields above materials. We successfully built the world's first “scanning cryogenic atom chip microscope”, and we now are in the process of characterizing its performance before using the instrument to take the first wide-area images of transport flow within unconventional superconductors, pnictides and oxide interfaces (LAO/STO), topological insulators, and colossal magnetoresistive manganites. We will do so at temperatures outside the capability of scanning SQUIDs, with ~10x better resolution and without 1/f-noise. A notable goal will be to measure the surface-to-bulk conductivity ratio in topological insulators in a relatively model-independent fashion. We have completed the construction of this magnetic microscope. The instrument uses atom chips—substrates supporting micron-sized current-carrying wires that create magnetic microtraps near surfaces for ultracold thermal gases and BECs—to enable single-shot and raster-scanned large-field-of-view detection of magnetic fields. The fields emanating from electronic transport may be detected at the 10 -7 flux quantum (Φ0) level and below; that is, few to sub-micron resolution of sub-nanotesla fields over single-shot, millimeter-long detection lengths. By harnessing the extreme sensitivity of atomic clocks and BECs to external perturbations, we are now in a position to use atom chips for imaging transport in new regimes. Scanning quantum gas atom chip microscopy introduces three very important features to the toolbox of high-resolution scanning microscopy of strongly correlated or topological materials: simultaneous detection of magnetic and electric fields (down to the sub-single electron charge level; no invasive large magnetic fields or gradients; simultaneous micro- and macroscopic spatial resolution; DC to MHz detection bandwidth; freedom from 1/ƒ flicker noise at low frequencies; and, perhaps most importantly, the complete decoupling of probe and sample temperatures. The atom chip microscope can operate at maximum sensitivity and resolution without regard to the substrate temperature. While the BEC is among the coldest objects realizable (100 nK temperatures are typical), the atom chip substrate can be positioned 1 μm away from the BEC and be as hot as 400 K or as cold as the cryostat can cool. This is because unlike superconducting probes, whose temperature is closely coupled to nearby materials, quantum gases are immune to radiative heating. The energy gap between a Rb atom’s ground state and first excited state far exceeds the typical energy of room-temperature blackbody radiation; such atoms are therefore transparent to radiation heating by materials at room temperature or below. We experimentally demonstrated a new atom chip trapping system that allows the placement and high-resolution imaging of ultracold atoms within microns from any ≤100 μm-thin, UHV-compatible material, while also allowing sample exchange with minimal experimental downtime. The sample is not connected to the atom chip, allowing rapid exchange without perturbing the atom chip or laser cooling apparatus. Exchange of the sample and retrapping of atoms has been performed within a week turnaround, limited only by chamber baking. Moreover, the decoupling of sample and atom chip provides the ability to independently tune the sample temperature and its position with respect to the trapped ultracold gas, which itself may remain in the focus of a high-resolution imaging system. We confine 100-nK BECs of 104 87Rb atoms near a gold-mirrored 100-μm-thick silicon substrate. The substrate can be cooled to 35 K without use of a heat shield, while the atom chip, 120-μm away, remains at room temperature. Atoms may be imaged with 1-μm resolution and retrapped every 16 s, allowing rapid data collection. Straightforward improvements will allow us to push sample temperatures close to 4 K, and improve imaging resolution from 1 μm down to a few-100 nm, thereby providing 10 -9 Φ0 detection sensitivity. We will test the utility of this technique by imaging the magnetic fields emanating from electronic transport and domain percolation in several interesting examples of strongly correlated or topologically protected materials. STM, transport, and x-ray scattering experiments have, among others, revealed the existence of a quantum liquid crystal state in iron (pnictide) and cuprate superconductors. This strongly correlated state of matter could also be detected by imaging the fluctuating transport (spatially and in time) of electrons as the phase/regime boundary is crossed between the pnictide non-Fermi liquid (cuprate strange metal) and the pnictide magnetic phase (cuprate pseudogap regime). Our ability to image wide-area inhomogeneous current flow from room-temperature to <10 K will allow us to study the developing domain structure and transport near twin boundary interfaces through the T N ≈50–150 K nematic transition recently identified in bulk transport experiments by Ian Fisher's group in underdoped Fe-arsinide superconductors. Again, this highlights a main feature of our cryogenic atom chip microscope: the ability to image transport regardless of the sample temperature since the BEC, at nK temperatures, is transparent to blackbody radiation, even when held a microns from the surface.

36 MATERIALS SCIENCE↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Laser-induced electron diffraction of the ultrafast umbrella motion in ammonia

Visualizing molecular transformations in real-time requires a structural retrieval method with Ångström spatial and femtosecond temporal atomic resolution. Imaging of hydrogen-containing molecules additionally requires an imaging method sensitive to the atomic positions of hydrogen nuclei, with most methods possessing relatively low sensitivity to hydrogen scattering. Laser-induced electron diffraction (LIED) is a table-top technique that can image ultrafast structural changes of gas-phase polyatomic molecules with sub-Ångström and femtosecond spatiotemporal resolution together with relatively high sensitivity to hydrogen scattering. Here, we image the umbrella motion of an isolated ammonia molecule (NH3) following its strong-field ionization. Upon ionization of a neutral ammonia molecule, the ammonia cation (NH3+) undergoes an ultrafast geometrical transformation from a pyramidal (ΦHNH=107°) to planar (ΦHNH=120°) structure in approximately 8 femtoseconds. Using LIED, we retrieve a near-planar (ΦHNH=117 ± 5°) field-dressed NH3+ molecular structure 7.8−9.8 femtoseconds after ionization. Our measured field-dressed NH3+ structure is in excellent agreement with our calculated equilibrium field-dressed structure using quantum chemical ab initio calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Energy 3D Calorimeter based on position-sensitive virtual Frisch-grid CdZnTe detectors for use in Gamma-ray Astronomy

We present a concept for a calorimeter based on a novel approach of 3D position-sensitive virtual Frischgrid CZT detectors. This calorimeter aims to measure photons with energies from ~100 keV to 10 (goal 50) MeV. The expected energy resolution at 662 keV is ~1% FWHM, and the photon interaction positionmeasurement accuracy is ~1 mm in all 3 dimensions. Each CZT bar is a rectangular prism with typical cross-section of 6x6 mm 2 and length of 2-4 cm. The bars are arranged in modules of 4 x 4 bars, and the modules themselves can be assembled into a larger array. The 3D virtual voxel approach solves a long-standing problem with CZT detectors associated with material imperfections that limit the performance and usefulness of relatively thick detectors (i.e., > 1 cm). Also, it allows us to relax the requirements on the quality of the crystals, maintaining good energy resolution and significantly reducing the instrument cost. Such a calorimeter can be successfully used in space telescopes that use Compton scattering of γ rays, such as AMEGO, serving as part of its calorimeter and providing the position and energy measurement for Compton-scattered photons. Also, it could provide suitable energy resolution to allow for spectroscopic measurements of γ-ray lines from nuclear decays. Another viable option is to use this calorimeter as a focal plane to conduct spectroscopic measurements of cosmic γ-ray events. In combination with a coded-aperture mask, it potentially could provide mapping of the 511-keV radiation from the Galactic Center region.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗