At least 775 records · Page 43

Operational impacts of high penetration solar power on a real-world distribution feeder

Higher penetration of solar photovoltaic (PV), with their uncontrollable generation variability, imposes various grid stability challenges on distribution system operation. The primary problem is significant voltage rise in the distribution feeder that forces existing voltage control devices such as on-load tap-changers and line voltage regulators to operate more frequently. The consequence is the deterioration of the operating life of the voltage control mechanism. The objective of this paper is to investigate the voltage impact of increased penetration of PV systems on distribution load tap changer operations. Both steady-state and quasi-static power flow analyses have been conducted to assess the impact on load tap changes under different solar PV penetration levels. Two real-world distribution feeder circuits are used as a test system in this study. Simulations are carried out for up to one-year period with 1-minute time step using OpenDSS. A comparison study was performed to investigate potential voltage rise issues in the network by increasing total PV penetration from 0 to 100% in the feeder. Results show significant increase in the total number of tap operations as solar PV penetration increases. Impacts on nodal voltages and feeder net power are also presented.

Dong, Jin↗

Recovery of Natural Gas Equipment Emissions into Gas Compression Engines for the Reduction of Potential Greenhouse Gas Emissions

Since the turn of the millennium, the United States (U.S.) oil and natural gas (ONG) industry has nearly doubled its natural gas production rate. As a result, the ONG industry has recently come under increasing scrutiny for its contributions to greenhouse gas (GHG) emissions. Consequently, various solutions to this problem have been proposed and formulated to reduce the impacts of GHG emissions on the environment. West Virginia University (WVU) have found it important to research the impacts of recovering vented gas streams into prime-mover engines. The U.S. Department of Energy (DOE) and National Energy Technology Laboratory (NETL) have granted WVU funding to research and develop a “Methane Mitigator” (M2) - a “Scalable Vent Mitigation Strategy to Simultaneously Reduce Methane Emissions and Fuel Consumption from the Compression Industry.” One of the main areas of interest for this research was the collection of emissions from natural gas equipment into a Caterpillar G3508J natural gas compression engine. The parameters being analyzed from the engine were brake-specific emissions and power output. The emissions sources considered for this research were pneumatic controllers (PCs), reciprocating compressor vents, and the engine’s open crankcase breather. The compressor vent and PC emissions were simulated using a mass flow controller (MFC) and flowed into the engine using two separate methods: (1) directly into the air intake, and (2) through a retrofitted closed crankcase ventilation system (CCV), serving as a buffer volume. The crankcase emissions were quantified without the CCV, and the impact on exhaust emissions from circulating the crankcase gases into the intake was measured. The simulated compressor vent and PC flows from the MFC had limited effect on the steady state operation of the engine and resulting performance. When the simulated flows were fed directly into the engine’s air intake, the changes within the engine’s continuous performance and emission parameters were larger but lasted for shorter durations. Conversely, when the simulated flows were fed into the CCV before entering the air intake, the changes in the engine’s performance and emission parameters were less pronounced for continuous analysis but lasted for longer durations. In either case, the continuous emission changes in both emissions and performance varied in size depending on the test scenario being run, but the cycle average changes in emissions and performance showed little impact overall compared to the engine’s baseline operation. As a result, the inclusion of a CCV shows a decrease in baseline carbon dioxide equivalent (CO2-eq.) engine emissions (from combined exhaust and open crankcase) of almost 4%. Likewise, the CCV inclusion reduced baseline total methane (CH4) from combined exhaust and open crankcase by upwards of 16%. These atmospheric emissions only decreased further with the inclusions of collected PC and compressor vent flows. The resulting changes in time-averaged rated exhaust behavior (or lack thereof) prove that the proposed M2 system could likely be deployed at sites with modern lean-burn natural gas engines as a viable option for reducing and eliminating potential GHG sources that would have otherwise been unutilized as energy sources.

03 NATURAL GAS↗

Mechanisms of Dynamic Near-Wake Modulation of a Utility-Scale Wind Turbine

The current study uses large eddy simulations to investigate the transient response of a utility-scale wind turbine wake to dynamic changes in atmospheric and operational conditions, as observed in previous field-scale measurements. Most wind turbine wake investigations assume quasi-steady conditions, but real wind turbines operate in a highly stochastic atmosphere, and their operation (e.g. blade pitch, yaw angle) changes constantly in response. Furthermore, dynamic control strategies have been recently proposed to optimize wind farm power generation and longevity. Therefore, improved understanding of dynamic wake behaviours is essential. First, changes in blade pitch are investigated and the wake expansion response is found to display hysteresis as a result of flow inertia. The time scales of the wake response to different pitch rates are quantified. Next, changes in wind direction with different time scales are explored. Under short time scales, the wake deflection is in the opposite direction of that observed under quasi-steady conditions. Finally, yaw changes are implemented at different rates, and the maximum inverse wake deflection and time scale are quantified, showing a clear dependence on yaw rate. To gain further physical understanding of the mechanism behind the inverse wake deflection, the streamwise vorticity in different parts of the wake is quantified. The results of this study provide guidance for the design of advanced wake flow control algorithms. The lag in wake response observed for both blade pitch and yaw changes shows that proposed dynamic control strategies must implement turbine operational changes with a time scale of the order of the rotor time scale or slower.

flow-structure interactions↗

The Transactive Network Template Metamodel

While transactive energy—an allocation of electricity based on dynamically discovered values or prices—has been extensively studied, its uptake and use has been slow. This report describes a tool, the transactive network template, which should hasten the creation and uptake of transactive energy networks. The transactive network template is a metamodel meant to guide implementers as they configure their own transactive agent within a network of such agents. The transactive network template’s object–oriented design approach provides implementers basic code object types, which may be used and extended to represent each of the assets in the implementer’s circuit region. These objects further facilitate the transactive agent’s necessary computations, which are divided among responsibilities to schedule assets’ power usage, to balance electric supply and demand, and to coordinate the exchange of electricity with the other transactive agents. This report addresses the conceptual transactive network template design. Implementers are directed to more formal design documents and reference implementations. A Python™-based [Python 2018] reference implementation of the transactive network template has been coded, and three implementations have been configured to represent a national laboratory and two university campuses. In the future, the author wishes to make the transactive network template more generally applicable to networks that require more accurate power flow and those employing alternative transactive coordination mechanisms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Electronics Thermal Control (Presentation)

Thermal management plays an important part in the cost of electric drives in terms of power electronics packaging. Very promising results have been obtained by using microporous coatings and skived surfaces in conjunction with single-phase and two-phase flows. Sintered materials and thermoplastics with embedded fibers show significant promise as thermal interface materials, or TIMs. Appropriatecooling technologies depend on the power electronics package application and reliability.

33 ADVANCED PROPULSION SYSTEMS↗

Multiphase Optimal and Non-Singular Power Flow by Successive Linear Approximations: Preprint

We propose an optimal power flow method for multiphase power systems. The method works for both radial and meshed networks, and is able to accommodate different types of load/source connections such as wye, delta, etc. Moreover, the method generates a sequence of non-singular points in the electrical state space and a corresponding sequence of power injections, which can be used in real-time control settings. Under certain conditions, the sequences attain the local minimum. The method has been tested using several typical networks, including the IEEE 37-bus and 123-bus test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrokinetic energy conversion using flow induced oscillations of single-cylinder with large passive turbulence control

Various types of flow-induced oscillations (FIOs) have been implemented in development of marine hydrokinetic (MHK) energy converters. With passive turbulence control (PTC), energy harvesting starts at a flow speed of about 0.5 m/s. However, there is worldwide MHK energy available in even slower currents. In the present study, the effect of damping on FIO and power extraction is investigated for a converter with large turbulence stimulation (PTC) consisting of straight strips with a height of 15% of the cylinder diameter and placed symmetrically on the cylinder surface. The oscillating amplitude decreases, as the damping ratio increases, with unchanged sinusoidal pattern of the displacement time-history. The frequency ratio is also affected by damping especially in the VIV initial branch and transition region between VIV and galloping. An important flow characteristic of the large-PTC cylinder is that a recirculation region is formed behind the PTC, causing appreciable disturbance to the flow past the cylinder. Power can be harvested in the whole FIO range and the harnessed power maximum appears at the largest inflow velocity tested. However, the optimum of harnessing efficiency is located at the beginning of the VIV upper branch. The gap between VIV and galloping is bridged when large PTC is used, eliminating the drop in power and efficiency even at higher damping, which would be a weakness of regular-PTC cylinder for energy harvesting. Finally, the mechanism behind the variation of harnessing efficiency with inflow velocity and damping ratio is revealed, and the optimality criterion for the converter design is discussed.

16 TIDAL AND WAVE POWER↗

Status Report for Development of Advanced Process Monitoring Concepts for IAEA Safeguards Sponsored by the Next Generation Safeguards Initiative (NGSI)

Process monitoring (PM) is used in international safeguards as an additional measure to nuclear material accountancy (NMA). For large throughput nuclear facilities such as commercial spent fuel reprocessing plants, it is difficult to satisfy the lAEA's goal for detection probability using NMA alone. And, for an facilities, regardless of their throughput, PM can provide redundant verification for both NMA and containment and surveillance and can be used to detect abnormal plant operation through the use of IAEA's instrumentation and selected operator's process control instrumentation. Examples of PM include (1) continuity of knowledge of nuclear material flows and inventories by monitoring of tank solution levels in reprocessing plants, (2) load cell monitoring of cylinders in GCEPs, (3) thermal power monitoring of large research reactors to detect undeclared operation, and (4) providing data to enable frequent NMA-like evaluation (near-real-time-accounting), which involves a hybrid of NMA and PM, for many facility types. Sensors required for PM include for example sensors for measuring flow, volume, density, level, temperature, and other diverse sensors such as portal monitors, video cameras, motion detectors, and gamma and neutron detectors. Additionally, PM lends itself to remote and/or unattended monitoring which has the potential to reduce the IAEA inspection burden and intrusiveness to the operator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploration Drilling and Technology Demonstration At Fort Bliss

The Tularosa-Hueco basin in south-central New Mexico has long been known as an extensional area of high heat flow. Much of the basin is within the Fort Bliss military reservation, which is an exceptionally high value customer for power independent of the regional electric grid and for direct use energy in building climate control. A series of slim holes drilled in the 1990s established the existence of a thermal anomaly but not its practical value. This study began in 2009 with a demonstration of new exploration drilling technology. The subsequent phases reported here delivered a useful well, comparative exploration data sets and encouragement for further development. A production-size well, RMI56-5, was sited after extensive study of archival and newly collected data in 2010-2011. Most of 2012 was taken up with getting state and Federal authorities to agree on a lead agency for permitting purposes, getting a drilling permit and redesigning the drilling program to suit available equipment. In 2013 we drilled, logged and tested a 924 m well on the McGregor Range at Fort Bliss using a reverse circulation rig. Rig tests demonstrated commercial permeability and the well has a 7-inch slotted liner for use either in production or injection. An August 2013 survey of the completed well showed a temperature of 90 C with no reversal, the highest such temperature in the vicinity. The well’s proximity to demand suggests a potentially valuable resource for direct use heat and emergency power generation. The drilling produced cuttings of excellent size and quality. These were subjected to traditional analyses (thin sections, XRD) and to the QEMScan™ for comparison. QEMScan™ technology includes algorithms for determining such properties of rocks as density, mineralogy, heavy/light atoms, and porosity to be compared with direct measurements of the cuttings. In addition to a complete cuttings set, conventional and resistivity image logs were obtained in the open hole before the well was cased.

15 GEOTHERMAL ENERGY↗

Summary on the depressurization from supercritical pressure conditions

When a fluid discharges from a high pressure and temperature system, a 'choking' or critical condition occurs, and the flow rate becomes independent of the downstream pressure. During a postulated loss of coolant accident (LOCA) of a water reactor the break flow will be subject to this condition. An accurate estimation of the critical flow rate is important for the evaluation of the reactor safety, because this flow rate controls the loss of coolant inventory and energy from the system, and thus has a significant effect on the accident consequences[1]. In the design of safety systems for a super critical water reactor (SCWR), postulated LOCA transients are particularly important due to the lower coolant inventory compared to a typical PWR for the same power output. This lower coolant inventory would result in a faster transient response of the SCWR, and hence accurate prediction of the critical discharge is mandatory. Under potential two-phase conditions critical flow is dominated by the vapor content or quality of the vapor, which is closely related with the onset of vaporization and the interfacial interaction between phases [2]. This presents a major challenge for the estimation of the flow rate due to the lack of the knowledge of those processes, especially under the conditions of interest for the SCWR. According to the limited data of supercritical fluids, the critical flows at conditions above the pseudo-critical point seem to be fairly stable and consistent with the subcritical homogeneous equilibrium model (HEM) model predictions, while having a lower flow rate than those in the two-phase region. Thus the major difficulty in the prediction of the depressurization flow rates remains in the region where two phases co-exist at the top of the vapor dome. In this region, the flow rate is strongly affected by the nozzle geometry and tends to be unstable. Various models for this region have been developed with different assumptions, e.g. the HEM and Moody model [3], and the Henry-Fauske non-equilibrium model [4], and are currently used in subcritical pressure reactor safety design[5]. It appears that some of these models could be reasonably extended to above the thermodynamic pseudo-critical point. The more stable and lower discharge flow rates observed in conditions above the pseudo-critical point suggests that even though SCWR's have a smaller coolant inventory, the safety implications of a LOCA and the subsequent depressurization may not be as severe as expected, this however needs to be confirmed by a rigorous evaluation of the particular event and further evaluation of the critical flow rate. This paper will summarize activities on critical flow models, experimental data and numerical modeling during blowdown from supercritical pressure conditions under the International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP) on 'Heat Transfer Behaviour and Thermo-hydraulics Code testing for SCWRs'. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A hybrid numerical and machine learning framework for evaluating the performance of a 780 cm 2 aqueous organic redox flow battery

Aqueous organic redox flow battery (AORFB) is a promising cost-competitive technology for large-scale energy storage. Among existing work, the dihydroxyphenazine (DHP)-based AORFB has demonstrated high energy density and low capacity degradation in 10 cm2 cells during lab tests. However, its commercial-scale performance in more complex environments remains unknown, posing a barrier for commercialization. To address this gap, this work presents a comprehensive performance evaluation of a 780 cm 2 DHP-based AORFB by combining physics-based numerical model, machine learning (ML)-based surrogate models, and ML-derived sensitivity quantification. Specifically, we first select 12 key battery parameters that include 10 physicochemical quantities and 2 operation quantities, then select 6 performance metrics that include energy efficiency (EE), discharging capacity, charging energy, and power losses due to concentration, activation, and ohmic over-potentials. With such selection, 12800 combinations of the 12 parameters are subsequently generated using the Latin Hypercube Sampling method. These combinations, together with 38 pre-defined State of Charge, are then integrated to a validated AORFB model developed in COMSOL to compute the performance metrics. With both input parameters and performance metrics, 60 deep neural network (DNN) surrogate models are then trained to approximate the relationship between the 10 physicochemical quantities and 6 performance metrics at each flow rate and current density. Sensitivity scores are then calculated based on the DNN models. Two additional sensitivity analysis tools, i.e., MARS, and SHAP, are also used to cross-validate the sensitivity scores from the DNN. The results demonstrate that 1) the standard potential ranks the first in controlling EE and charging energy, 2) the membrane conductivity is most critical for power loss and EE, and 3) specific area and reaction rate control activation power loss.

25 ENERGY STORAGE↗

Real time computations of cryogenic He properties

The Fermilab PIP-II (proton improvement plan - II) project is being constructed at Fermilab to deliver $800\,MeV$ protons of $>1\,MW$ beam power to replace the present LINAC and provide protons to the remainder of the existing accelerator complex. The new LINAC consists of a warm front end, 23 superconducting RF cryomodules, and a beam transfer line to the existing complex. The cryomodules (CMs) are to be tested at Fermilab's CryoModule Test Facility (CMTF).An important measurement in cryogenic testing is the heat load of each CM. Traditionally, at Fermilab, these measurements were made collecting archived data offline and analyzing it. The new control system for PIP-II is being developed with the EPICS (Experimental Physics and Industrial Control System) framework, which allows us to compute the heat load in real time using the HePak library.We are exploring other $He$ properties, such as flow, where flow meters are not available, which can also be calculated in real time and fed back to the cryogenics engineers.This paper details the real time heat load calculation and $He$ flow software developed for CM testing at CMTF, as well as the first results from the prototype HB650 CM. Future plans for 2-phase $LHe$ flow will also be outlined.

Hanlet, Pierrick [Fermilab]↗

Quantification of energy and cost reduction from decreasing dissolved oxygen levels in full‐scale water resource recovery facilities

Abstract Aeration systems often lack the efficiency to maintain a desired residual dissolved oxygen (DO) concentration in the tank in part because little consideration is given to the dynamic daily and seasonal loading conditions. Although advanced aeration controllers exist, the majority of plants have DO set points typically based on common practice and literature values rather than site‐specific conditions, which can result in DO set points higher than those necessary to meet treatment objectives. DO set point reduction strategies have primarily been proposed through either static or dynamic simulations. In this study, the substantial improvements associated with DO set point reduction are demonstrated at full scale. A yearlong characterization of full‐scale aeration dynamics captured the effect of diurnal and seasonal fluctuations on oxygen transfer and energy demand and so facilitated the estimation of the potential savings of DO reduction strategies. Full‐scale validation provided direct evidence of DO reduction strategies inducing an overall enhancement of oxygen transfer efficiency along the different bioreactors, while confirming that energy savings as high as 20% were feasible. This study quantifies the influence of oxygen transfer efficiency on operating choices and site‐specific conditions (control strategy, loading conditions, and influent flow variability). Practitioner points We quantified the energy reduction and cost savings associated with a DO reduction in an aeration tank. For each 0.2 mg/L of DO decreased, the average power demand reduction per unit water treated exceeded 17%. Field measurements of dynamic alpha values eliminate the uncertainty in estimating aeration energy and cost savings from DO variations.

Pasini, Federico↗

Temporal Decompostion of a Distribution System Quasi-Static Time-Series Simulation

This paper documents the first phase of an investigation into reducing runtimes of complex OpenDSS models through parallelization. As the method seems promising, future work will quantify - and further mitigate - errors arising from this process. In this initial report, we demonstrate how, through the use of temporal decomposition, the run times of a complex distribution-system-level quasi-static time series simulation can be reduced roughly proportional to the level of parallelization. Using this method, the monolithic model runtime of 51 hours was reduced to a minimum of about 90 minutes. As expected, this comes at the expense of control- and voltage-errors at the time-slice boundaries. All evaluations were performed using a real distribution circuit model with the addition of 50 PV systems - representing a mock complex PV impact study. We are able to reduce induced transition errors through the addition of controls initialization, though small errors persist. The time savings with parallelization are so significant that we feel additional investigation to reduce control errors is warranted.

14 SOLAR ENERGY↗

Modeling Single and Two-Phase Transport in Thin Porous Layers Using a Composite Continuum-Pore Network Formulation

In this work, a composite continuum-pore network formulation is presented to model single and two-phase transport thin porous layers, such as gas diffusion layers in polymer electrolyte fuel cells (PEFCs) and active electrodes in redox flow batteries (RFBs). The formulation can be integrated into CFD codes, thus combining the ease of implementation of continuum-based modeling and the computational power of pore-network modeling. The composite model includes a control volume (CV) mesh at the layer scale, which embeds a cubic pore network [1,2]. The pore-network model is used to determine analytically local anisotropic effective transport properties (local effective diffusivity and permeability), which are mapped onto the CV mesh to simulate transport in the porous transport layer [3,4]. Good agreement is found between the predicted global effective transport properties (global effective diffusivity and permeability) under dry and wet conditions and previous experimental data reported in the literature for Toray TGP-H series carbon paper. Water saturation distributions are also compared with results obtained using X-ray computed tomography [4]. [1] P.A. García-Salaberri, I.V. Zenyuk, J.T. Gostick, A.Z. Weber, Modeling Gas Diffusion Layer in Polymer Electrolyte Fuel Cells Using a Continuum-Based Pore-Network Formulation, ECS Trans. 97 (2020) 615. [2] P.A. García-Salaberri, Modeling diffusion and convection in thin porous transport layers using a composite continuum-network model: Application to gas diffusion layers in polymer electrolyte fuel cells, Int J. Heat Mass Transf. (2020), submitted. [3] P.A. García-Salaberri, J.T. Gostick, G. Hwang, A.Z. Weber, M. Vera, Effective diffusivity in partially-saturated carbon-fiber gas diffusion layers: Effect of local saturation and application to macroscopic continuum models, J. Power Sources 296 (2015) 440–453. [4] P.A. García-Salaberri, G. Hwang, M. Vera, A.Z. Weber, J.T. Gostick, Effective diffusivity in partially-saturated carbon-fiber gas diffusion layers: Effect of through-plane saturation distribution, Int. J. Heat Mass Transf. 86 (2015) 319–333.

Garcia-Salaberri, Pablo↗

Modular Hybrid Solid State Transformer (H-SST) for Next Generation Flexible and Adaptable Large Power Transformer (LPT) (Final Technical Report)

A 500 kVA HSST, the world first of such system, has been successfully developed. The HSST has the capability to regulate the power flow of the transmission or distribution power lines, or provide voltage regulation. The HSST design is modular therefore it has the ability to be connected in series of parallel to form a large power transformer with smart controllability. The project has enabled a high TRL level prototype be demonstrated at University of Texas at Austin which can lead to additional commercialization and demonstration opportunities. A large number of students were trained under this program that will benefit the power grid industry. A number of publications are published at well known international conferences and journals, further accomplish the mission of knowledge development and dissemination.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A DATA EFFICIENT SPARSE MODELING FRAMEWORK FOR POWER ESTIMATION IN WATER TREATMENT SENSING OPERATIONS

With increasing freshwater scarcity, advanced process design mechanisms such as Closed-Circuit Reverse Osmosis (CCRO) and Digital/Physical Twin systems are gaining traction in water treatment and reuse operations. While digital and physical twin models enable improved system insight and control, their development is often expensive and computationally intensive, requiring large volumes of synthetic or experimental data to characterize underlying process dynamics. This work introduces a sparse surrogate modeling framework to estimate power consumption from measured flow and pressure variables, along with their nonlinear polynomial and interaction expansions. To ensure model reliability and reduce overfitting, a two-stage pipeline is proposed. First, a dynamic data filtering algorithm is employed to remove uninformative observations and transient operational states. Second, a sparse penalized regression technique is applied to select a minimal set of parsimonious features. The proposed model achieves high sparsity, retaining only 7 out of 34 candidate features (≈79.41% sparsity) while delivering a root mean square error (RMSE) of 0.072 on the test dataset.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Kiloampere, Variable-Temperature, Critical-Current Measurements of High-Field Superconductors

We review variable-temperature, transport critical-current ($I_\text{c}$) measurements made on commercial superconductors over a range of critical currents from less than 0.1 A to about 1 kA. We have developed and used a number of systems to make these measurements over the last 15 years. Two exemplary variable-temperature systems with coil sample geometries will be described: a probe that is only variable-temperature and a probe that is variable-temperature and variable-strain. The most significant challenge for these measurements is temperature stability, since large amounts of heat can be generated by the flow of high current through the resistive sample fixture. Therefore, a significant portion of this review is focused on the reduction of temperature errors to less than ±0.05 K in such measurements. A key feature of our system is a pre-regulator that converts a flow of liquid helium to gas and heats the gas to a temperature close to the target sample temperature. The pre-regulator is not in close proximity to the sample and it is controlled independently of the sample temperature. This allows us to independently control the total cooling power, and thereby fine tune the sample cooling power at any sample temperature. The same general temperature-control philosophy is used in all of our variable temperature systems, but the addition of another variable, such as strain, forces compromises in design and results in some differences in operation and protocol. These aspects are analyzed to assess the extent to which the protocols for our systems might be generalized to other systems at other laboratories. Our approach to variable-temperature measurements is also placed in the general context of measurement-system design, and the perceived advantages and disadvantages of design choices are presented. To verify the accuracy of the variable-temperature measurements, we compared critical-current values obtained on a specimen immersed in liquid helium (“liquid” or $I_{\text{c}}$ $_{\text{liq}}$) at 5 K to those measured on the same specimen in flowing helium gas (“gas” or Ic gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb 3 Sn, and MgB 2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the “correct” critical current, which was assumed to be the $I_{\text{c}}$ $_{\text{liq}}$. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases.

47 OTHER INSTRUMENTATION↗