Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Co-Simulation for Advanced Process Design and Optimization

Meeting the increasing demand for clean, affordable, and secure energy is arguably the most important challenge facing the world today. Fossil fuels can play a central role in a portfolio of carbon-neutral energy options provided CO{sub 2} emissions can be dramatically reduced by capturing CO{sub 2} and storing it safely and effectively. Fossil energy industry faces the challenge of meeting aggressive design goals for next-generation power plants with CCS. Process designs will involve large, highly-integrated, and multipurpose systems with advanced equipment items with complex geometries and multiphysics. APECS is enabling software to facilitate effective integration, solution, and analysis of high-fidelity process/equipment (CFD) co-simulations. APECS helps to optimize fluid flow and related phenomena that impact overall power plant performance. APECS offers many advanced capabilities including ROMs, design optimization, parallel execution, stochastic analysis, and virtual plant co-simulations. NETL and its collaborative R&D partners are using APECS to reduce the time, cost, and technical risk of developing high-efficiency, zero-emission power plants with CCS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

FLEXO: A Portably Performant Code for Pulsed Power Target Physics

FLEXO (Flux-Limited Extended-MHD Ohm's Law) is a production-line multiphysics code developed at Sandia to enable more predictive modeling of target physics on pulsed-power devices. FLEXO uses an extended magnetohydrodynamics (XMHD) model which includes a generalized Ohm's law (GOL), an electron inertia term, and Hall physics. This report describes the code's numerical methods, its computational performance, and test problems of interest.

42 ENGINEERING↗

Mid-Lift-to-Drag Ratio Rigid Vehicle 6-DOF EDL Performance Using Tunable Apollo Powered Guidance

The Mid-Lift-to-Drag ratio Rigid Vehicle (MRV) is a candidate in the NASA multi-center effort to determine the most cost effective vehicle to deliver a large-mass payload to the surface of Mars for a human mission. Products of this effort include six-degree-of-freedom (6DoF) entry-to-descent trajectory performance studies for each candidate vehicle. These high fidelity analyses help determine the best guidance and control (G&C) strategies for a feasible, robust trajectory. This paper presents an analysis of the MRV's G&C design by applying common entry and descent associated uncertainties using a Fully Numerical Predictor-corrector Entry Guidance (FNPEG) and tunable Apollo powered descent guidance.

human↗

Mid-Lift-To-Drag Ratio Rigid Vehicle 6-DOF EDL Performance Using Tunable Apollo Powered Guidance

The Mid-Lift-to-Drag ratio Rigid Vehicle (MRV) is a candidate in the NASA multi-center effort to determine the most cost effective vehicle to deliver a large-mass payload to the surface of Mars for a human mission. Products of this effort include six-degree-of-freedom (6DoF) entry-to-landing trajectory performance studies for each candidate vehicle. These high fidelity analyses help determine the best guidance and control (G&C) strategies for a feasible, robust trajectory. This paper presents an analysis of the MRV's G&C design by applying common entry and descent associated uncertainties using a Fully Numerical Predictor-corrector Entry Guidance (FNPEG) and tunable Apollo powered descent guidance.

Johnson, Breanna J.↗

Method to improve reliability of a fuel cell system using low performance cell detection at low power operation

A system and method for detecting a low performing cell in a fuel cell stack using measured cell voltages. The method includes determining that the fuel cell stack is running, the stack coolant temperature is above a certain temperature and the stack current density is within a relatively low power range. The method further includes calculating the average cell voltage, and determining whether the difference between the average cell voltage and the minimum cell voltage is greater than a predetermined threshold. If the difference between the average cell voltage and the minimum cell voltage is greater than the predetermined threshold and the minimum cell voltage is less than another predetermined threshold, then the method increments a low performing cell timer. A ratio of the low performing cell timer and a system run timer is calculated to identify a low performing cell.

30 DIRECT ENERGY CONVERSION↗

Wind Turbine Generator System Power Quality Test Report for the Gaia Wind 11-kW Wind Turbine

This report details the power quality test on the Gaia Wind 11-kW Wind Turbine as part of the U.S. Department of Energy's Independent Testing Project. In total five turbines are being tested as part of the project. Power quality testing is one of up to five test that may be performed on the turbines including power performance, safety and function, noise, and duration tests. The results of thetesting provide manufacturers with reports that may be used for small wind turbine certification.

17 WIND ENERGY↗

Tuning of Nacelle Feedback Gains for Floating Wind Turbine Controllers Using a Two-DOF Model

Designing a collective blade pitch controller for floating offshore wind turbines (FOWTs) poses unique challenges due to the interaction of the controller with the dynamics of the platform. The controller must also handle the competing objectives of power production performance and fatigue load management. Existing solutions either detune the controller with the result of slowed response, make use of complicated tuning methods, or incorporate a nacelle velocity feedback gain. With the goal of developing a simple control tuning method for the general FOWT researcher that is easily extensible to a wide array of turbine and hull configurations, this last idea is built upon by proposing a simple tuning strategy for the feedback gain. This strategy uses a two degree-of-freedom (DoF) turbine model that considers tower-top fore-aft and rotor angular displacements. For evaluation, the nacelle velocity term is added to an existing gain scheduled proportional-integral controller as a proportional gain. The modified controller is then compared to baseline land-based and detuned controllers on an example system for several load cases. First-pass results are favorable, demonstrating how researchers can use the proposed tuning method to efficiently schedule gains for adequate controller performance as they investigate new FOWT configurations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Neutron and gamma irradiation effects on power semiconductor switches

The performance characteristics of high power semiconductor switches subjected to high levels of neutron fluence and gamma dose must be known by the designer of the power conditioning, control and transmission subsystem of space nuclear power systems. Location and the allowable shielding mass budget will determine the level of radiation tolerance required by the switches to meet performance and reliability requirements. Neutron and gamma ray interactions with semiconductor materials and how these interactions affect the electrical and switching characteristics of solid state power switches is discussed. The experimental measurement system and radiation facilities are described. Experimental data showing the effects of neutron and gamma irradiation on the performance characteristics are given for power-type NPN Bipolar Junction Transistors (BJTs), and Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs). BJTs show a rapid decrease in gain, blocking voltage, and storage time for neutron irradiation, and MOSFETs show a rapid decrease in the gate threshold voltage for gamma irradiation.

Schwarze, G. E.↗

Spokane Eco-District Campus Performance Under Alternative Electricity Rates: Benefits for virtual power plant participants and suppliers

Here, the respective benefits for virtual power plant participants and suppliers are revealed and compared under alternative electricity rate structures, including conventional large commercial electricity rates, large commercial electricity rates with special rates for demand-side generation, and dynamic hourly transactive prices. These three scenarios were explored using the capabilities of the Eco-District campus, a virtual power plant in Spokane, Washington, that is supplied electricity by Avista Utilities. The Eco-District Campus was modeled to host solar power generation, battery energy storage, and thermal energy resources that must be coordinated with building heating and cooling needs. First, the electricity supplier’s costs for energy, infrastructure, and energy losses were modeled. Then, the virtual power plant’s performance was modeled while presuming that its manager would minimize its costs under its electricity rate structure. The demand charges of conventional commercial electricity rates managed monthly peak, as would be expected, but hourly dynamic transactive pricing resulted in a striking alignment between the costs incurred by the supplier and the virtual power plant’s energy costs.

Electricity rates↗

Design Assessment of Brayton Cycles for Combined Heat and Power from Nuclear Power Plants

Brayton cycles (BCs) are gaining renewed interest for use in high-temperature nuclear reactors for power production. This study explores the potential of nuclear Brayton systems in industrial combined heat and power (CHP) production. After a review of the historical deployment and technical development of BC systems for nuclear and cogeneration applications several BCs in CHP configurations are assessed when applied to representative high-temperature reactor types. The analysis emphasizes process heat delivery options, electrical efficiency, and component performance for the case of a direct cycle—Helium BC in a high temperature gas reactor, and an open-air Brayton cycle with a high temperature gas reactor. The results highlight thermodynamic trade-offs in cogeneration operation, particularly in recuperated configurations, and compare BC-based CHP with conventional Rankine cycle (RC) performance. Key findings suggest Helium BCs offer viable CHP performance primarily at lower process heat temperatures, with open air cycles being less efficient. The work also demonstrates trade-off between CHP performance and power production performance with a detailed comparison to where steam RC has better performance. The work is designed to be used as a reference work when cogeneration is proposed from high temperature reactors alongside the use of BCs.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

GridPACK Toolkit for Developing Power Grid Simulations on High Performance Computing Platforms

This paper describes the GridPACK™ framework, which is designed to help power grid engineers develop modeling software capable of running on todays high performance computers. The framework contains modules for setting up distributed power grid networks, assigning buses and branches with arbitrary behaviors to the network, creating distributed matrices and vectors, using parallel linear and non-linear solvers to solve algebraic equations, and mapping functionality to create matrices and vectors based on properties of the network. In addition, the framework contains additional functionality to support IO and to manage errors.

Palmer, Bruce J.↗

Pyranometers and Reference Cells, What's the Difference?: Preprint

As the photovoltaic industry has grown exponentially in the past decade, large photovoltaic (PV) fields have become more common. The investors for these projects calculate the expected return on investment based on expected electricity generation and adjust the interest rates and other financial terms according to the perceived risk. These calculations usually assume worst case according to thelisted warranty and any uncertainty in the measurement is translated directly into a reduced predicted performance. Because a 1% difference in predicted output could represent a large fraction of the expected return on investment, a small reduction in uncertainty translates into a much larger value to the entity making investment decisions. To reduce perceived risk in large-scale solarinvestments power plant performance (or production) guarantees have become increasingly common. This two part article explores some subtleties of accurately measuring PV efficiency in the field.

14 SOLAR ENERGY↗

Identification and Assessment of Material Models for Age-Related Degradation of Structures and Passive Components in Nuclear Power Plants

When performing seismic safety assessments of nuclear power plants (NPPs), the potential effects of age-related degradation on structures, systems, and components (SSCs) should be considered. To address the issue of aging degradation, the Korea Atomic Energy Research Institute (KAERI) has embarked on a five-year research project to develop a realistic seismic risk evaluation system which will include the consideration of aging of structures and components in NPPs. Three specific areas that are included in the KAERI research project, related to seismic probabilistic risk assessment (PRA), are probabilistic seismic hazard analysis, seismic fragility analysis including the effects of aging, and a plant seismic risk analysis. To support the development of seismic capability evaluation technology for degraded structures and components, KAERI entered into a collaboration agreement with Brookhaven National Laboratory (BNL) in 2007. The collaborative research effort is intended to continue over a five year period with the goal of developing seismic fragility analysis methods that consider the potential effects of age-related degradation of SSCs, and using these results as input to seismic PRAs. In the Year 1 scope of work BNL collected and reviewed degradation occurrences in US NPPs and identified important aging characteristics needed for the seismic capability evaluations that will be performed in the subsequent evaluations in the years that follow. This information is presented in the Annual Report for the Year 1 Task, identified as BNL Report-81741-2008 and also designated as KAERI/RR-2931/2008. The report presents results of the statistical and trending analysis of this data and compares the results to prior aging studies. In addition, the report provides a description of U.S. current regulatory requirements, regulatory guidance documents, generic communications, industry standards and guidance, and past research related to aging degradation of SSCs. This report describes the research effort performed by BNL for the Year 2 scope of work. This research focused on methods that could be used to represent the long-term behavior of materials used at NPPs. To achieve this BNL reviewed time-dependent models which can approximate the degradation effects of the key materials used in the construction of structures and passive components determined to be of interest in the Year 1 effort. The intent was to review the degradation models that would cover the most common time-dependent changes in material properties for concrete and steel components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementing Inertial Control for PMSG-WTG in Region 2 Using Virtual Synchronous Generator with Multiple Virtual Rotating Masses

With the increasing integration of renewable energy, the problems associated with a deteriorating grid frequency profile and potential power system instability have become more significant. In this paper, the inertial control algorithm using a virtual synchronous generator (VSG) is implemented on a Type 4 permanent magnet synchronous generator (PMSG) wind turbine generator (WTG). The overall nonlinear dynamic model and its small-signal linearization of the PMSG-WTG using a VSG is established and comprehensively analyzed. Inevitably, the direct application of the VSG introduces a large inertia, which causes conflict between the fast variance of available wind power and inverter control with slow dynamics, particularly in Region 2 of the wind turbine. Aiming to address such issues, a VSG with multiple virtual rotating masses is proposed to improve the active power tracking performance as well as to boost the inertial control of a VSG. The inertial responses are verified in a modified 10-MVA IEEE 14-bus microgrid system. The assessment of the simulation results demonstrates the applicability of the VSG on renewable energy generation units.

17 WIND ENERGY↗

A Systems Model for Power Technology Assessment

A computer model is under continuing development at NASA Glenn Research Center that enables first-order assessments of space power technology. The model, an evolution of NASA Glenn's Array Design Assessment Model (ADAM), is an Excel workbook that consists of numerous spreadsheets containing power technology performance data and sizing algorithms. Underlying the model is a number of databases that contain default values for various power generation, energy storage and power management and distribution component parameters. These databases are actively maintained by a team of systems analysts so that they contain state-of-art data as well as the most recent technology performance projections. Sizing of the power subsystems can be accomplished either by using an assumed mass specific power (W/kg) or energy (Wh/kg) or by a bottoms-up calculation that accounts for individual component performance and masses. The power generation, energy storage and power management and distribution subsystems are sized for given mission requirements for a baseline case and up to three alternatives. This allows four different power systems to be sized and compared using consistent assumptions and sizing algorithms. The component sizing models contained in the workbook are modular so that they can be easily maintained and updated. All significant input values have default values loaded from the databases that can be over-written by the user. The default data and sizing algorithms for each of the power subsystems are described in some detail. The user interface and workbook navigational features are also discussed. Finally, an example study case that illustrates the model's capability is presented.

Hoffman, David J.↗

What Is the Value of Alternative Methods for Estimating Ramping Needs?

Power system operators procure and deploy flexibility reserves or ramping products to address balancing needs caused by uncertainty and variability of load and generation. Existing methods estimate ramping needs using calendar information and historical forecast errors. Novel methods investigate if real-time weather information could inform ramping and other balancing requirements. This paper compares estimation methods for ramping requirements in theory and practice. The theoretical framework indicates when an alternative method could yield improved economic or reliability performance than existing methods by requiring lower or higher levels of ramping products. Preliminary simulations on a 118-bus test system for 4 days in May 2019 illustrate how system performance improves or deteriorates when ramping requirements are weather-informed (alternative) instead of calendar-based (baseline). Preliminary results suggest high variability in change of performance and underline the impact of additional factors, such as system conditions, on the realized performance change.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Automated Antenna Design with Evolutionary Algorithms

Current methods of designing and optimizing antennas by hand are time and labor intensive, and limit complexity. Evolutionary design techniques can overcome these limitations by searching the design space and automatically finding effective solutions. In recent years, evolutionary algorithms have shown great promise in finding practical solutions in large, poorly understood design spaces. In particular, spacecraft antenna design has proven tractable to evolutionary design techniques. Researchers have been investigating evolutionary antenna design and optimization since the early 1990s, and the field has grown in recent years as computer speed has increased and electromagnetic simulators have improved. Two requirements-compliant antennas, one for ST5 and another for TDRS-C, have been automatically designed by evolutionary algorithms. The ST5 antenna is slated to fly this year, and a TDRS-C phased array element has been fabricated and tested. Such automated evolutionary design is enabled by medium-to-high quality simulators and fast modern computers to evaluate computer-generated designs. Evolutionary algorithms automate cut-and-try engineering, substituting automated search though millions of potential designs for intelligent search by engineers through a much smaller number of designs. For evolutionary design, the engineer chooses the evolutionary technique, parameters and the basic form of the antenna, e.g., single wire for ST5 and crossed-element Yagi for TDRS-C. Evolutionary algorithms then search for optimal configurations in the space defined by the engineer. NASA's Space Technology 5 (ST5) mission will launch three small spacecraft to test innovative concepts and technologies. Advanced evolutionary algorithms were used to automatically design antennas for ST5. The combination of wide beamwidth for a circularly-polarized wave and wide impedance bandwidth made for a challenging antenna design problem. From past experience in designing wire antennas, we chose to constrain the evolutionary design to a monopole wire antenna. The results of the runs produced requirements-compliant antennas that were subsequently fabricated and tested. The evolved antenna has a number of advantages with regard to power consumption, fabrication time and complexity, and performance. Lower power requirements result from achieving high gain across a wider range of elevation angles, thus allowing a broader range of angles over which maximum data throughput can be achieved. Since the evolved antenna does not require a phasing circuit, less design and fabrication work is required. In terms of overall work, the evolved antenna required approximately three person-months to design and fabricate whereas the conventional antenna required about five. Furthermore, when the mission was modified and new orbital parameters selected, a redesign of the antenna to new requirements was required. The evolutionary system was rapidly modified and a new antenna evolved in a few weeks. The evolved antenna was shown to be compliant to the ST5 mission requirements. It has an unusual organic looking structure, one that expert antenna designers would not likely produce. This antenna has been tested, baselined and is scheduled to fly this year. In addition to the ST5 antenna, our laboratory has evolved an S-band phased array antenna element design that meets the requirements for NASA's TDRS-C communications satellite scheduled for launch early next decade. A combination of fairly broad bandwidth, high efficiency and circular polarization at high gain made for another challenging design problem. We chose to constrain the evolutionary design to a crossed-element Yagi antenna. The specification called for two types of elements, one for receive only and one for transmit/receive. We were able to evolve a single element design that meets both specifications thereby simplifying the antenna and reducing testing and integration costs. The highest performance antenna found using a getic algorithm and stochastic hill-climbing has been fabricated and tested. Laboratory results correspond well with simulation. Aerospace component design is an expensive and important step in space development. Evolutionary design can make a significant contribution wherever sufficiently fast, accurate and capable software simulators are available. We have demonstrated successful real-world design in the spacecraft antenna domain; and there is good reason to believe that these results could be replicated in other design spaces.

Hornby, Gregory S.↗